Page 1: Presenter: Frank Kessler Water and Energy Conservation for the Dallas Metropolitan YMCA.

Presenter:Frank Kessler

Water and Energy Conservation for the Dallas Metropolitan YMCA

Page 2: Presenter: Frank Kessler Water and Energy Conservation for the Dallas Metropolitan YMCA.

Locations

19 OwnedLocations

Page 3: Presenter: Frank Kessler Water and Energy Conservation for the Dallas Metropolitan YMCA.

By encorporating the following recommendations, YMCA Dallas can:

Become an institution committed to sustainability. Operate more efficiently.

• Use these savings for other programs Become a model for other YMCA’s.

The criteria used to prepare this report centered around energy and water conserving measures that:

Can be readily identified. Can provide a reasonably short payback and ROI.

Goals

Page 4: Presenter: Frank Kessler Water and Energy Conservation for the Dallas Metropolitan YMCA.

Water and Energy savings strategies:

Replace plumbing fixtures at 19 facilities. Install swimming pool covers at 8 facilities. Install laundry ozone generators at 8 facilities. Install energy controllers at vending machines. Install a water treatment system at cooling tower.

Strategies

Page 5: Presenter: Frank Kessler Water and Energy Conservation for the Dallas Metropolitan YMCA.

Savings generated

plumbingfixtures

$ 190,568 $ 134,611 1.5 yrs.

pool Covers

$ 96,280 $ 66,192 1.5 yrs.

ozoneGenerator

$ 86,120 $ 22,874 3.8 yrs.

*vendingcontrollers

$ 5,907 $ 3,465 1.7 yrs.

cooling tower $ 22,016 $ 5,286 4.2 yrs

Cost Savings Payback

I

II

III

IV

V

$ 403,931 $ 232,846 1.7 yrs

* ‘Snack Miser’ controllers included

Page 6: Presenter: Frank Kessler Water and Energy Conservation for the Dallas Metropolitan YMCA.

Strategies

Page 7: Presenter: Frank Kessler Water and Energy Conservation for the Dallas Metropolitan YMCA.

Plumbing Fixture - Inventory

Page 8: Presenter: Frank Kessler Water and Energy Conservation for the Dallas Metropolitan YMCA.

Plumbing Fixtures – (7 older facilities)

Page 9: Presenter: Frank Kessler Water and Energy Conservation for the Dallas Metropolitan YMCA.

Plumbing Fixtures – (7 older facilities)

Page 10: Presenter: Frank Kessler Water and Energy Conservation for the Dallas Metropolitan YMCA.

Plumbing Fixtures – (12 newer facilities)

Page 11: Presenter: Frank Kessler Water and Energy Conservation for the Dallas Metropolitan YMCA.

Plumbing Fixtures – (12 newer facilities)

Page 12: Presenter: Frank Kessler Water and Energy Conservation for the Dallas Metropolitan YMCA.

7 OLD facilities -all fixtures replaced

7 OLD facilities -toilets & urinals replaced+aerators & showerheads

12 NEWER Facilities -aerators & showerheads

Plumbing Fixtures – Costs

Page 13: Presenter: Frank Kessler Water and Energy Conservation for the Dallas Metropolitan YMCA.

Swimming Pool Covers

T Boone Pickens – Indoor Pool

Page 14: Presenter: Frank Kessler Water and Energy Conservation for the Dallas Metropolitan YMCA.

Swimming Pool Covers

Outdoor Pool cover

IndoorPool cover

Single reel

Double reel

Triple reel

Page 15: Presenter: Frank Kessler Water and Energy Conservation for the Dallas Metropolitan YMCA.

Swimming Pool Covers – 8 facilities

Page 16: Presenter: Frank Kessler Water and Energy Conservation for the Dallas Metropolitan YMCA.

Pool Cover – savings at Coppell

ROI for Coppell Indoor Pool

Ref.: ‘Pool Energy Use Calculator’ Washington State University

Page 17: Presenter: Frank Kessler Water and Energy Conservation for the Dallas Metropolitan YMCA.

Pool Cover ROI – all 8 facilities

Page 18: Presenter: Frank Kessler Water and Energy Conservation for the Dallas Metropolitan YMCA.

Laundry Ozone System

larger installation

smaller installationT Boone Pickens laundry

Page 19: Presenter: Frank Kessler Water and Energy Conservation for the Dallas Metropolitan YMCA.

Ozone Laundry System

ROI for T Boone Pickens

Yearly savings of $22,874 for 8 facilities

Page 20: Presenter: Frank Kessler Water and Energy Conservation for the Dallas Metropolitan YMCA.

Vending Miser

Vending Machines at all 19 facilities

‘Vending Miser’ controller & sensor

Page 21: Presenter: Frank Kessler Water and Energy Conservation for the Dallas Metropolitan YMCA.

‘Vending Miser’

Manufacturer’s Data

Yearly savings of $3,480 for 33 ‘Vending Misers’

• ‘Snack Miser’ controllers at 19 non-refrigerated snack machines saved $418 per year with a simple payback of 7.3 years

Page 22: Presenter: Frank Kessler Water and Energy Conservation for the Dallas Metropolitan YMCA.

‘Vending Miser’

ROI for one ‘Vending Miser’

Page 23: Presenter: Frank Kessler Water and Energy Conservation for the Dallas Metropolitan YMCA.

Cooling Tower Water Treatment

450 Ton Cooling Tower at T Boone Pickens YMCA

Page 24: Presenter: Frank Kessler Water and Energy Conservation for the Dallas Metropolitan YMCA.

Cooling Tower Water Treatment

Existing system:Dissolved minerals precipitate and deposit themselves on cooling tower surfaces.

‘Dolphin WaterCare’:Electric field strips suspended particles of static charge. The particles then become the preferred surface for minerals to precipitate to.

Page 25: Presenter: Frank Kessler Water and Energy Conservation for the Dallas Metropolitan YMCA.

Cooling Tower Water Treatment

Yearly savings of $ 5,286 ROI at T Boone Pickens

Page 26: Presenter: Frank Kessler Water and Energy Conservation for the Dallas Metropolitan YMCA.

Grant Writing

The Richardson Family YMCA was selected as an individual project and used to develop a Grant Proposal to the (GP) Georgia-Pacific Foundation for water (resource) conservation. GP’s funding limitation is $25,000.

Why was Georgia-Pacific selected as a funding source?

they have a strong interest in the Environment and Resource Conservation.

their grant program fits the goals and objectives of the Project.

our project satisfies their funding requirements.

Page 27: Presenter: Frank Kessler Water and Energy Conservation for the Dallas Metropolitan YMCA.

YMCA Project Review

“This report is detailed, thorough, and comprehensive. We will be reviewing it with Senior Management and we will be implementing some of these items immediately…”

Stanley G. Thomas, AIAVice President of Properties & Facilities

YMCA of Metropolitan Dallas