    ommitmentrchase Prescolite Emer-ncy Systems products withe confidence of receiving theest value in emergency light-ng. This commitment for highality, exceptional service andttention to your needs is sup-orted by over 45 years of dedi-ated service to our customers.

    DependabilityAll Prescolite Emergency Sys-tems products are manufac-tured to exacting specifica-tions. Reliable maintenancefree lead calcium batteries areused throughout and all hous-ings have a precision fit toproperly protect both the bat-tery and circuitry. A variety ofstandard features combine tomake Prescolite products unsur-passed in dependability.

    StandardsEmergency lighting systemsplaya critical role in safety, AllPrescolite emergency productsare manufactured to exactingperformance standards andmeet or exceed all applicableUL, NFPA, NEe, and NEMAcodes.

    Attention To DetailPrescolite has been supplyingthe lighting industry with inno-vative, high quality products fornearly half a century.This expe-rience and extra attent ion todetail is reflected in the supe-rior performance of all productsthai make up our emergencylighting line.

  • 8/3/2019 Prescolite Emergency Systems ES-4 1992

    3/60

    Features and BenefitsThe following are standardfeatures on most PrescoliteEmergency Systems:Dual Voltage:. (120 and 277VAC).Automatic Low Voltage Dis-connect: Prevents battery dam-age by not allowing the batteryto discharge too deeply.Thermal Protection: Preventsthe unit from overheatingRegulated and FilteredCharge Voltage: Allows op-timal battery charging withcontinuously monitored andfiltered voltage.

    Reverse Polarity Protection:Insures proper connection ofbattery to charger.Short Circuit Protection: Allremote lampheads are fused toinsure against short circuits.Brown-out Activation: Whenthe supply voltage drops below80%, the unit will automaticallyswitch to emergency mode.AC Lockout: Prevents batteryfrom discharging unt il AC pow-er is initially applied.

    Prescolits's CVS (ContinuousVerification System) emer-gency lighting line features astate-of-the-art microcontrollerwhich is programmed to contin-uously (every 1.90 seconds)verify all vital funct ions of theemergency unit. Should a prob-lem with a CVS emergency unitoccur, a red external light willflash indicating that the unitmust be serviced. Indicatorl ights within the unit pinpointthe exact problem ... charger,battery or lamp failure.In emergency situat ions it iscritical that the emergencylighting equipment functionsproperly. Prescolite's CV8emergency lighting productscontinuously verify that anysystem failure is immediatelyidentified.

    In addition to identifying wheer a unit has experienced a stem failure, the CVS featurealso indicates the status of thunit. Prescolite's CVS is trulyuser friendly. Anyone presentnot just maintenance person-nel, will be able to instantly recognize that the unit requiresservicing. Once the unit isopened fo r service, the internindicator lights quickly and acurately pinpoint the specificmalfunction (see followingpages for details).

  • 8/3/2019 Prescolite Emergency Systems ES-4 1992

    4/60

    Advanced Emergency

    PRESCOLITE

    2 PrescoliteEmergency Systems

    TESTINTERVALS

    The evs emergency l ighting unitsconduct tests to verify properoperation continuouslyand on 90 minute, monthlyand semi-annual intervals. Manualtests may also be performed atany time. A mal function during anyself test wil l be indicated by theexternal and internal statusindicators,

    For complete informationon Prescolite's evs l ine ofemergency products, referto Prescotite catalognumber eVS-l .

    1Every 1.90 Seconds .... . t he evs circuitry verifies allfunctions that are cri tical foremergency operation, The circuitchecks the charger regulator,battery connections and VOltage,lamp readiness, and Ae supply linecondition. The evs circuitry verifiesthese functions by reading theexisting value of voltages, andcompares them to storedinformation on the microcontroller.The battery connection is verif iedby switching 011the charger toconfirm i fa battery is in the circui t.Units that require service can beidentified by the external flashingred status indicator, and specificservice requirements are identifiedby internal indicators,

    2Every 90 Minutes, . ,, the evs circuitry tests thebattery capacity. The battery'scapacity is diagnosed by applyinga resistive load without illuminatingthe lamps and veri fying that thevoltage of the battery is withinproper limits at the end of the load

    test. This confirms that the batteryhas the capabili ty to performproperly during a power fai lure.

    Every 28 Days. , ., , , t he evs Circuitry conducts af ive minute test. This test activatesthe relay and discharges thebattery, s imulat ing a power fai lure .On all uni ts/systems using lessthan 30 watts, the CVS may be fie ldset for partial or full lamp headillumination. Lamp'heads are fullyi lluminated on units/systems usingover 30 watts, This test furtherensures proper battery capacityand the unit's emergency transfercircuitry.

    4Every Six Months _. _

    . the evs circuitry, as required bythe National ElectriC Code and theNational Fire ProlectionAssociation, tests the system underful l load. The evs conducts a ful l90 minute test with full illuminationof the lamp heads The tests imulates a power fai lure andverif ies the unit's operat ion to code.The instal ler has the option ofchanging the test duration to 30minutes, 60 minutes, or no test.

    5A t A ny Time ...

    . . t he evs ci rcuit ry can test forproper operation. This is accomp-lished by pushing the manual testswitch that triggers a removal of ACcurrent The microcontro ller wil ldiagnose this as an Ae supply fail-ure which will cause the emer-gency lamp heads to i lluminate forfifteen minutes.

  • 8/3/2019 Prescolite Emergency Systems ES-4 1992

    5/60

    Lighting Technology .

    PRESCOLITE. .-: ' ,,. .. . : '. .', .

    TMM a n u a l T e s t

    S t a t u s

    R e a d yA u to T e s tC h a r g i n g= S E R V I C ER EM O VE C OV ER

    VISUALINDICATORS

    External Status IndicatorsEach unit is equipped with anexternal bi-colored light emittingdiode (LED). The color and state ofthe LED signif ies the Unit'scondition.

    Green - Ready:incicates the unit is ready andfunctioning properly.

    Flashing Green - AUTO TEST:The uni t is conducting an auto-matic scheduled self test

    Red - CHARGING:The uni t's battery is charging andis not yet at ful l capacity.

    Flashing Red - SERVICE:Indicates there is a malfunct ion andrequires service. Additional infor-mation is conlainedinside the unit .

    Internal Indicators

    When the external status indicatoris flashing red, the uni t must beopened for service. The circuitboard has three separate clearlylabeled LED'S, each signifying afai lure corresponding to thecharger, battery or lampheads.

    CVS Checks ...

    Battery

    Circuil Board

    III LampsWiring Integrity

    Frequently (1.90 Seco

    PerCodes(NEC,NFPA)

    Presco/ite Emergency Systems

  • 8/3/2019 Prescolite Emergency Systems ES-4 1992

    6/60

    CONTENT

    ET4ET6Lj ET4-12V m I DT6-12V FTET B Exit Lite 24,25 40,41ETlO UPSETl2 18,19 ' T i T 42,43~ EDS2 ETl4 C-UPSEDS4 6, ? ET16 EDX4 26 44,45ET20 PR-232!! ET22 iI 46,47ELB2 ~ EST4 EmergencyELB4 8 EST:i 27EST7 20E : j ESB?

    ESTl-12V

    m r nSB7-12V 9 tl EDP2 Edge-lit 28.29ESB11 EDP3 21EDP4 ~@ ERC2 10 8~ Thinline 30.31EXP3 22~

    DERT4 StandardERTS 11 Profile 30,31CFR8EM0CFR813EM 12.13 m RecessedCFR818EM 30,31CFR826EM ELH Head 50m T I)f;::, ECH Diecast ESH HeadECl-3EC2-2 14 Emergency 32,33 50EC2-5

    Exit EDH Heade 50ESI ~ EL EMC Head 50ES2 15 Exit 34,35 Square 51~

    EFPlDouble Recessed

    EFP1-S00

    51

    EFP3Gimbal

    EFP4 1651

    EFP5Recessed Rectangle 51Weatherproof 51Aisle Light 51

    4 Prescome Em e rg en cy S ys te m s

    51

  • 8/3/2019 Prescolite Emergency Systems ES-4 1992

    7/60

  • 8/3/2019 Prescolite Emergency Systems ES-4 1992

    8/60

    DESIGNER SERIES

    E X I T

    The EDS4 can supply emergencypower to a remote mounted exit.

    6 Presco/ile Emergency Systems

    The Designer is available inwhite or black and with a factorya tta ch ed e xit (s ee p ag e 2 6).

  • 8/3/2019 Prescolite Emergency Systems ES-4 1992

    9/60

    Featuring a contemporary appearance, the Designerseries adds style to a reliable and technologicallyadvanced unit. AvaiIable with remate ca pabi Iity or with afactory attached exit, the designerfamily is ideally suited

    DESIGNER SERIEfor commercial or institutional facilities where economappearance and ease of installation are overridinconcerns.

    Features 6 volt, maintenance free leadcalcium battery

    Dual voltage (120/277) Automatic low voltagedisconnect Injection molded high Impactthermoplastic Labor saving snap togetherhousing

    Standard white housing,optional black available Thermally protected Regulated charge voltage Reverse polarity protection Filtered charger output Universal mounting plate forultimate flexibility Short circuit protection Brownout protection

    AC lockout Labor saving exit -emergencylight combination available.See page 26.

    _-------. TMs

    Option Suffixes ElectricalBase Output Watts AC Input StandardCatalog Output 1 .5 2 3 4 Lamp RemoteNumber BL EV1 ECS CVS Volts hrs. hrs. hrs. hrs. Volts Amps Watts Wattage CapabilityEDS2 6 15 11 8 6 120 .070 8. 4 7.2 No277 .032 8. 8EDS4 6 30 22 15 12 120 ,070 8, 4 7,2 Yes277 ,032 8, 8

    Vandal resistant shield, wire-guard, remote heads and fixturesshould be ordered as separateline items, For details on addi-t ionallampheads and acces-sories see pages 50 and 51,

    OPTION DESCRIPTIONBL: Black housingECS: 3 foot cordsetEWG4: WireguardEV1: VoltmeterEVRS1: Vandal resistantshieldCVS: Continuous VerificationSystem

    TO ORDER:Order EDS2 or EDS4. For options,suff ix base catalog number withdesired option.Example: EDS4-BL.

    DIMENSIONS:

    P re sc o/ite Em e rge nc y S ys te m s

  • 8/3/2019 Prescolite Emergency Systems ES-4 1992

    10/60

    ELB SERIESAttractive and conventional, the ELB series is designedto be aesthetically pleasing and unobtrusive in itssurroundings. Available in two sizes, the ELB genies is

    ideal for applications where economy, appearance andthe use of a conventionally designed unit is a primeconcern.

    Features 6 volt, maintenance free leadcalcium battery Dual voltage (120/ 277) Automatic low voltagedisconnect Injection molded high impactIh.ermoplastic

    Standard white housing,optional black available Thermally protected Regulated charge voltage Reverse polarity protection Filtered charger output Universal mounting plate lorultimate flexibility Short circuit protection Brownout proteclion AC lockout Capable of powering fromtwo to four lampheads

    Option Suffixes ElectricalBase Output Watts AC Input StandardCatalog Output 1.5 2 3 4 Lamp RemoteNumber EV2 ' EAM2' ECS Vol,ts hrs. hrs. hrs, hrs. Volts Amps Watts Wattag.e CapabilityElB2 6 15 11 8 6 120 .070 8.4 7.2 No 277 .032 8.8ElB4 6 30 22 15 12 120 .070 8,4 7.2 YesI 277 .032 8.8 II

    C h 0 ic e o f EV 2 01 E AM 2. N OI aval lab le wilh bOlh .

    DIMENSIONS:

    1----10"----1Side Mount Heads:length 211'.", Height 5\-,,' and Depth 4%"

    8 Presco/ite Emergency Systems

    Wireguards, remole heads andfixtures should be ordered asseparate line items. For detailson additional lampheads and ac-cessories see pages 50 and 51 .

    OPTION DESCRIPTIONEV2: VoltmeterEAM2: AmmeterECS: 3 foot cordselEWG2: Wireguard

    (Iampheads on side)EWG3: Wireguard

    (Iampheads on top)BL: Black housing

    TO ORDER:Order base catalog numberELB2 or ELB4. For options,suff ix base catalog number withdesired option.Example: ELB4-ECS.

  • 8/3/2019 Prescolite Emergency Systems ES-4 1992

    11/60

    The ESB series provides up to 100 output watts with thecapability of powering up to eleven heads. The unobtru-sive housing features softly rounded corners and isconstructed of rugged high impact thermoplastic. Referbelow to numerous quality features and accessories.

    Features Maintenance free leadcalcium battery Dual voltage (120/277) Automatic low voltagedisconnect Injection molded high impactthermoplastic

    Standard white housing,optional black available Thermally protected Regulated charge voltage

    Reverse polar ity protection Filtered charger output Universal mounting plate forultimate flexibility Short circuit protection Brownout protection AC lockout Capable of powering fromtwo to eleven heads A wide range of sealed beamlamps available

    ESB SERIE

    ./

    Option SuffiJ.'6S ElectricalBase j . . . . . . Output Watts AC lnput'I StandardCatalog ~ o . , .$ rJ " " _ : : . , < J : J e Output 1.5 2 3 4 Lamp RemoteNumber t{} tl f li; ~ Q Volts hrs. hrs. hrs. hrs. Volts Amps Watts Wattage Capabili

    ESB7 6 50 38 25 20 120 .170 20.4 7.2 Yes277 .073 20.4ESB7-12V 12 50 38 25 20 120 .112{.322) 13.4{38.6) 9.0 Yes277 .052(.138) 14.4(38.2)ESB11 12 100 76 54 44 120 .322 38.6 90 Yes 277 .138 38.2 Cho ice of EV2. EA M2 or EA M3. O n Iy a v ai la b le w i th o n e.t A C in put ra tin gs w ith p are nth es es I ) are t or N i c ad u n it s.:I : Choice of NB or CVS. not both.

    Wireguard, remote heads andfixtures should be ordered asseparate l ine items. For detai lson additional lampheads and ac-cessories see pages 50 and 51 .OPTION DESCRIPTIONEV2: VoltmeterEAM2: Ammeter for ESB7

    and ESB7 -12VEAM3: Ammeter for ESB11ECS: 3 foot cord setEWG2: WireguardETD: Time delayBL: Black housingNB: Nicad batteryCVS: Continuous Verification

    System

    TO ORDER:Order base catalog number ESB7,ESB7-12V or ESe 11. For options,suffix base catalog number withdesired option.Example: ESB7-EAM2.

    DIMENSIONS:

    PrescoliteEmergency Systems

  • 8/3/2019 Prescolite Emergency Systems ES-4 1992

    12/60

    ERCSERIESRecessed into the wall o r ceiling, the ERC2 is a true lowprofile emergency lighting unit. Unobtrusive and easy toinstall, the ERC2 is ideal for applications where an

    attractive unit is desired and no remote capability isneeded.

    Features 6 volt, maintenance free leadcalcium battery Dual voltage (120/277) Automatic low voltagedisconnect Injection molded thermo-plastic heads and mountingplate

    Standard white faceplate,optional black available Thermally protected Regulated charge voltage Reverse polarity protect ion Filtered charger output Short circuit protection Brownout protection AClockout Mounting kit available for usewith suspended ceilings

    Mini cylinder heads with highoutput halogen lampsavailable

    Option Suffixes EleotricalBase Output Watts AC Input StandardCatalog Output 1.5 2 3 4 Lamp RemoteNumber ERCMK EMC-H0607 Volts hrs, hrs, hrs, hrs. Volts Amps Watts Wattage Capability

    ERC2 6 15 11 8 6 120 .070 8.4 7.2 No277 .032 8.8DIMENSIONS:

    1%"1I10 Prescolile Emergency Systems

    Wireguard, remote heads andfixtures should be ordered asseparate line items. For detailson additional lampheads and ac-cessories see pages 50 and 51,

    OPTION DESCRIPTIONERCMK: T-Bar mounting ki tEMC-H0607: Mini cylinder

    heads with 7 watthalogen lamps

    EWG3: WireguardTO ORDER:Order ERC2. For options, suffixbase catalog number withdesired option.Example: ERC2-EMC-H0607.

  • 8/3/2019 Prescolite Emergency Systems ES-4 1992

    13/60

    Easy to install and unobtrusive the ERT series is theultimate recessed unit Designed for use in T-Bar gridceilings, the ERT series blends in with the ceiling tile tomake it appropriate for commercial applications.

    . . .Features 6 volt, maintenance free leadcalcium battery Dual voltage (120/277)

    Automatic low voltagedisconnect

    Heavy 20 gauge steelhousing construction Standard white housing Thermally protected Regulated charge voltage

    ERT SER

    Reverse polarity protection Filtered charger output Easy to install T -Bar lay-indesign Short circuit protect ion Brownout protection AC lockout Housing can accommodatup to three heads

    Option Suffixes ElectricalBase Output Watts AC Inputt StandardCatalog Output 1.5 2 3 4 lamp RemoteNumber EV2* EAM2 NB ECS Volts hrs. hrs. hrs. hrs, Volts Amps Watts Wattage CapabilitERT4 6 30 22 15 12 120 ,070(.118) 8.4(14.2} 7.2 Yes277 ,032(.053) 8,8(14.7)ERT5 12 50 38 25 20 120 112 13,4 so Yes 277 ,052 14,4

    Choice a t EV2 or EAM2 , Not ava. il able wi th both,t A C in pu t r atin gs w it h p are nth es es ( ) a r e 1 0' N i c ad u nits ,

    Remote heads and fixturesshould be ordered as separateline items, For details on ad-ditional lampheads and acces-sories see pages 50 and 51.OPTION DESCRIPTIONEV2: VoltmeterEAM2: AmmeterECS: 3 foot cordsetNB: Nicad battery

    TO ORDER:Order base catalog numberERT4 or ERTS For options, sulf ixbase catalog number withdesired option.Example: ERT4-ECS.

    ---23%"--.'-------...,r r r - - - - - - - - - - - - f ~7W'f~~DIMENSIONS:

    5\4"LPresco/ite Emergency Systems

  • 8/3/2019 Prescolite Emergency Systems ES-4 1992

    14/60

    RECESSED EMERGENCY DOWNLIGHTS

    Prescolite continues its role asa leader in the development ofcompact fluorescent fixtures.Our current line of 9 and 13watt emergency compact f luo-rescent down lights has beenexpanded to include 18 and 26watllamps. Incorporating theemergency lighting into thedownlights enhances thearch itecture.During normat power, thefixtures operate as standarddownlighls. Should a powerinterruption occur, the systemwill allow one lamp to remain12 Prescome Emergency Systems

    illuminated for a minimum of 90minutes. The emergency down-lights are UL approved andmeet all emergency lightingrequirements.All Prescolite emergency down-l ights incorporate high tem-perature resistant nickel cad-mium batteries to ensure a longand reliable life for the system.To test the status of the sys-tem, an indicator light and testswitch are inconspicuouslymounted between the lamps. Thelamps. test switch and indicatorlight are outside the normal

    Test switch and indicator l ight are discreetly mounted on the top of thereflector.

    viewing angle but are clearlyvisible from directly below thefixture. Competitive emergencydownlights require a separatemounting plate for the testswitch and indicator l ight.All fixtures have die cast alu-minum plaster flanges and areavailable in 120 or 277 volt.Reflectors are available in clearor champagne gold Alzak orwith a baffle. Self trim optionavailable with Alzak reflectors.Iridescence suppressed clearreflector available.

    For complete information onPrescolite's comprehensive line ofcompact fluorescent fixtures referto Prescolile catalog number CF-5,"Com pact Fluorescent Catalog,"

  • 8/3/2019 Prescolite Emergency Systems ES-4 1992

    15/60

    RECESSED EMERGENCY DOWNLIGHTS

    Clear Trim Gold Trim Baffled TrimHefiect ars

    Base Standard Self TrimCatalog LampNumber Clear Gold Baffle Clear Gold DescriptionCFH8EM 472EM 473EM B472EM ST472EM ST473EM (2) 9 WaltCFR813EM 572EM 573EM B572EM ST572EM ST573EM (2 ) 13 WallCFR816EM 482EM 483EM B482EM ST482EM ST483EM (2) 18 WaltCFR826EM 492EM 493EM B492EM ST492EM ST493EM (2)26 Wall

    ELECTRICALPower Total OperatingCatalog Number Factor Watts Amps

    CFR8EM (120V) .57 24 .36CFR8EM (277V) 31 26 .36CFR813EM (120V) ,47 34 .60CFR813EM (277V) .23 39 .60CFR818EM (120Vj .51 48 .78CFR818EM (277V) .96 44 .17CFR826EM (120V) ,41 64 1.30CFR826EM (277V) .94 60 .23

    N ote : 1 8W a no 2 6W 2 77V j~ s ta n da rd H P f

    DIMENSIONS:t - 1 - - - - - - 19W'-----------JI T713116"L ~ . ~.; --===-~

    Ceiling Cutout !l511~"MaXimum Widlh: 12"For 9W and 13W units

    Features Premium high temperatureresistant nickel cadmiumbattery

    120 or 277 volt; specify Quick disconnect insidehousing prevents dischargduring installation

    Clear and champagne gospecular Alzak or baffledreflector available

    White polypropylene trimring standard Self trimmed Alzak ref lectoavailable

    Diecasl aluminum plasterflange Suitable for switched orunswitched circuits High power factor availabl- contact factory ULlisted for through wirin Meets all emergency lightstandardsTO ORDER:1. Suffix base catalog numbewith desired trim.

    2. Suffix entire catalog numbwith (120V) or (277V).Example:CFR813EM-ST572EM (120

    DIMENSIONS:

    Cei ling Cutout : 85/,6"Maximum Wldlh: 149/82"For 18W and 26W units

    Prescot /Ie Emergency Systems

  • 8/3/2019 Prescolite Emergency Systems ES-4 1992

    16/60

    EC SERIESAvailable with either single or twin cylinders and inmattewhite, black, orOSHAyeliowthe EC series is decorative as well as functional. Units are available in output wattsup to 50 and with remote capability.

    ECt Single Head ECMK ReC

  • 8/3/2019 Prescolite Emergency Systems ES-4 1992

    17/60

    ES SERIEInstalled as a recessed, semi recessed, or surfacemounted emergency fixture, the ES series offers theuser ultimate flexibility with a very attractive and conven-

    tionallooking unit. Resembling a standard luminaire, tESseries is attractive, dependable, and rugged. Ideasuited for stairwell and corridor applications.

    Features 6 volt, maintenance free leadcalcium battery Dual voltage (120/277) Automatic low voltagedisconnect Injection molded high impactthermoplastic

    Standard white housing Thermally protected Regulated charge voltage Reverse polarity protection Filtered charger output Universal mounting plate forultimate flexibility

    Short circuit protection Brownout protection AC lockout Recessed and semi recessedmounting kits available High output halogen lampstandard Test switch and pilot lightstrategically located to beunobtrusive S em i R e c es s e d Fu ll y Reoessed

    Option Suffixes ElectricalBase Output Watts AC Input StandardCatalog Output 1.5 2 3 4 Lamp RemoteNumber EV1'EAM" ESSMK ESRMK Volts hrs, hrs. hrs. hrs. Volts Amps Watts Wattage CapabilitESl 6 15 11 8 6 120 .070 8.4 10.0 No 277 .032 8.8ES2 6 30 22 15 12 120 .070 8.4 10.0 Yes 277 .032 8.8

    ChQ ice 01E \l1 or EAM1. NOI aval la cla wi th both.

    DIMENSIONS:Wireguard, remote heads andfixtures should be ordered as sep-arate line items. For details onadditional lampheads and acces-sories see pages 50 and 51.

    ' " " ' I - r - - - - - 9W ' sq. - - - - . - I I. . . - - t ~I I3W' ' - - 1 ' ' ' ' ' - - - - - - - - . . . . . . . ,~L. ~

    . .. . . .. .. . . - -- 1OW' sq.----I

    OPTION DESCRIPTIONEV1: VoltmeterEAM1: AmmeterESSMK': Semi recessed

    mounting kitESRMK*: Recessed mount ing kitEWG3: Wireguard'can be ordered separately

    TO ORDER:Order base catalog number ES1or ES2. For options, suff ix basecatalog number with desiredoption.Example: ES2-EV1.

    Prescolile Emergency Systems

  • 8/3/2019 Prescolite Emergency Systems ES-4 1992

    18/60

    EFP SERIESCompact and easy to install, the EFP series is a veryefficient and reliable fluorescent battery pack. Utilizingthe most advanced electronics available, the EFPis

    ideal for applications where cost and reliability arekey issues.

    Provides emergency powerfor any instant or rapid startballast

    Premium sealed nickelcadmium battery Dual voltage (120/277) Batlery case made of heavygauge steel Provides a full 90 minutes ofemergency illumination

    Test switch and indicator lightstandard: Compatible with standard TB,T12, U-Shaped, Circline,Energy Saving, Biaxial orOctronlamps

    Easy installat ion with versatilemounting capability Operates up to two lamps Ful13 year warranty EFP3 can power one 2' to 4'lamp lor 120 minutes

    Option Suffixes ElectricalBase NumberCatalog Output Initial of Lamps Lamp InputNumber EWB Wattage Lumens Operated Sizes Wattage

    EFPl 9.6 350-450 1 2'-4' 3.5I

    EFPI-500 14.4 500-600 1 2'-4' 3.5EFP3 14.4 600-700 1 2'-8' 3. 5EFP4 14.4 600-700 2 2'-8' 3.5EFP5 24.0 1100-1200 2 2'-8' 4.0DIMENSIONS:

    Unit A B CEfPl 9% " IV!' 2W "EFPl-500. 9% " lW' 2W 'EFP3 9W' 1 Y/' 2% "EFP4 9% " ' IW ' 2%"'EFP5 13% " 1 ' \ 1 , " 2%"'

    16 Presco/i te Emergf; incy Systems

    OPTION DESCRIPTIONEWB: Wire bundle cover lor

    installation on top offixture.

    TO ORDEROrder EFPl , EFPI-500, EFP3,EFP4 or EFP5. For wire bundlecover, suffix b a se cat alo q num-ber with EWB.Example: EFP3-EWB.

  • 8/3/2019 Prescolite Emergency Systems ES-4 1992

    19/60

  • 8/3/2019 Prescolite Emergency Systems ES-4 1992

    20/60

    ET SERIESThe ET series is ideal for industrial applications whereruggedness and reliability are prime concerns. With avariety of wattages available the ET series can be usedas a stand alone fixture or in conjunction with remote

    High ca pacily wei cell(ET ' 4) uni l ava ilab le .

    DIMENSIONS;

    18" D

    Features Maintenance free leadcalcium batteries (wet leadacid on ET14)

    Dual voltage (120/277) Automatic low voltagedisconnect High impact steel housingand lampheads Sealed beam Par-36lamps standard Thermally protected Regulated charge voltage Reverse polarity protection Filtered charger output

    OPTION DESCRIPTIONEV2: VoltmeterEAM2: Ammeter for ET4

    and ET4-12VEAM3: Ammeter for ET6,

    ET6-12V, ET8, ET10,ET12 and ET14EAM4: Ammeter for ET16,

    ET20,ET22ECS: 3 foot cordsetESHLF: Support shelfEWG1: WireguardETD: Time delayCVS: Continuous Verification

    SystemNB: Nicad battery

    18 Presco/ ite Emergency Systems

    Short circuit protection Brownout protection AC lockout Knockout provided on top foroptional third lighting head Bracket for ease of instal-lat ion and added support isstandard

    Use bracket or shelf to mountdirectly to wall

    Bronze polyester powdercoated housing and lamp-heads standard; resistant tocorrosion

    Wireguard, shelf, remote headsand fixtures should be orderedas separate line items. Fordetails on additionallampheadsand accessories see pages 50and 51.

    TO ORDEROrder base catalog number.For options, suffix base catalognumber with desired option.Example: ETa-ECS.

  • 8/3/2019 Prescolite Emergency Systems ES-4 1992

    21/60

    ET SERIEheads to form an integrated system. All units arestandard with dual voltage (120/277V) and sealedbeam lamps.

    Option Suffixes ElectricalBase $$$ . . . . . Output Watts AC Inputt StandardCatalog ~rv ~ . : : , . 0 . . . . . ~ Output 1.5 2 3 4 Lamp RemoteNumber 4J i l J i l J i l J l.ij CJ $J fq Volts hrs. hrs. hrs. hrs. Volts Amps Watts Wattage Capabili

    ET4 6 50 38 25 20 120 .170 20.4 12 Yes 277 .073 20.4ETS 6 75 57 38 30 120 .170 20.4 12 Yes277 .073 20.4ET4-12V 12 50 38 25 20

    120 .112(.322) 13.4(38.6) 12 Yes 277 .052(.138) 14.4(38.2)ETS-12V 12 75 57 38 30 120 .322 38.6 12 Yes 277 .138 38.2ET8 12 100 76 54 44 120 .322 38.6 12 Yes 277 .138 38.2ET10 12 125 95 65 50 120 .322 38.6 12 Yes277 .138 38.2ET12 12 150 115 75 60 120 .649 77.8 12 Yes277 .284 78.6ET14 12 180 136 95 70 120 .649 77.8 12 Yes 277 .284 78.6ET16 12 200 150 100 80 120 .649 77.8 12 Yes 277 .284 78.6ET20 12 250 180 125 100 120 .649 77.8 12 Yes 277 .284 78.6ET22' 12 275 200 150 120 120 .649 77.8 12 Yes 277 .284 78.6t AC ,npul r~l ,ngs with pare ntheses ( I are for Nieaa unns.* Chorea 01NB o r CVS, nOI both . Con tact fa clary 10 (avai labi li ly 01uni ts up to 420 watts,

    P re sc ofite E me rge nc y S ys te m s

  • 8/3/2019 Prescolite Emergency Systems ES-4 1992

    22/60

    EST SERIES

    Choice of EV2 01 EAM2. NOI ava l lable with both.t AC input r ati ngs with parent heses ( I ar e for Ni cad units.

    DIMENSIONS:

    L-9W,_JSide Mounl heads: Length 20W'

    20 Presco/ile Emergency Systems

    Reverse polarity protection. Filtered charger output Universal mounting plate forultimate flexibility Short circuit protection Brownout protection AC lockout A wide range of sealed beamlamps available Optional 20 gauge steellampheads available

    The EST series is especially suited for lower wattageindustrial and demanding commercial applications.Heavy duty steel housing and optional steellampheadscreate a durable unit.

    Features Maintenance free leadcalcium battery Dual voltage (120/277) Automatic low voltagedisconnect Injection molded high impactthermoplastic lampheads Heavy 18 gauge steelhousing construction Standard while housing Thermally protected Regulated charge voltage

    Wireguard, remote heads andfixtures should be ordered asseparate line items. Fo r detailson additionallampheads and ac-cessories see pages 50 and 51.

    OPTION DESCRIPTIONEV2: VoltmeterEAM2: AmmeterEGS: 3 foot cord setEWG 1: WireguardETD: Time delayNB: Nicad batteryBAZ: Bronze housing

    Option Suffixes ElectricalBase Output Watts AC Inputt StandardCatalog Output 1.5 2 3 4 Lamp RemoteNumber EV2' EAM2* ECS NB ETD Volts hrs. hrs. hrs. hrs. Volts Amps Watts Wattage Capability

    EST4 6 30 22 15 12 120 .010(.118) 8.4(14.2) 7.2 Yes277 .032(.053) 8.8(14.7)EST5 6 36 27 18 15 120 .170 20.4 7.2 Yes 277 .073 2004EST? 6 50 38 25 20 120 .170 20.4 7.2 Yes 277 .073 20.4EST7-12V 12 50 38 25 20 120 .112(.322) 13.4(38.6) 9.0 Yes277 .052(.138) 14.4(38.2)

    TO ORDER:Order base catalog number ESTE8T5.EST7 or EST7-12V. Foroptions. suffix base catalog numwith desired option.Example: EST4-EtD.

  • 8/3/2019 Prescolite Emergency Systems ES-4 1992

    23/60

    Features M ain tenance free leadc a lc ium ba tt er y Dual vo ltage (120/277) A utom atic low vo ltagedisconnec t In je ctio n m olde d h ig h im pa ctVa lo x hou si ng Sealed and gaske tedconstruct ion T he rm ally p ro te cte d R egu la ted cha rg e vo lta ge R ev er se p ola rity p ro te ctio n F ilte re d ch arge r o utp ut

    Se ale d a nd g as ke te d, th e N EM A s erie s is d es ig ne d to b estrong , rugged and technolog ica lly re liab le . M ade o fh ig h imp a ct V alo x , t he NEMA se rie s is d es ig n ed fo r h ars ho r c orro siv e e nv iro nmen ts w he re o il, w ate r a nd d us t tig htc on s tru ctio n is re q uir ed .

    Option Suffixes ElectricalBase Output Watts AC Inputt StandardCatalog Cyst NB* Output 1.5 2 3 4 lamp RemotNumber ETD Volts hrs. hrs. hrs. hrs. Volts Amps Watts Wattage CapabilEDP2 6 15 11 8 6 120 .070(.118) 8.4(14.2) 7.2 No277 .032(.053) 8.8(14.7}EDP3 6 30 22 15 12 120 .070 8.4 7.2 Yes277 .032 8.8EDP4' 12 50 38 25 20 120 .112(.322) 13.4(38.6) 8.0 Yes 277 .052( .138) 14.0(38.2)

    t A C in put ra tin gs w ith p are nth es es ( ) a re fo r N ie ad units.t C ho ic e o f N B o r C VS . n ot b oth . Conlac l factory lor avei la bi li ly 01uni ts up 10 I 25 wa tts.

    W ire gu ard , re mo te h ea ds a ndfix tu re s s ho uld b e o rd ere d a ss e pa ra te lin e item s. F o r d e ta ilso n a dd itio na l la mp he ad s a nd a c-cessorie s see pages 5 0 and 51 ,

    O P TIO N DESCR IP TIO NE TD : T im e d ela yEWG 1 : W ir eg ua rdN B : N ic ad b atte ryCVS : Con ti nu ous Ve rif ic a tio nSystem

    Comp lies w ith NEMA 4X andNEMA 12 rat ings S ta nd ard p re -d rille d m ou ntin gf langes T op co nd uit e ntry p ro vid ed Sealed and gaske ted tes ts witc h a nd in dic ato r lig ht Pa r-36 s ea le d b ea m la mp sstandard Powe rs two to s ix heads B ro wno ut p ro te ctio n A C lockout Halogen lamp standa rd on

    12 v o lt u n it

    T O O RD ER :O rd er E DP2 , E DP3 or E DP4 .F or o p tio n s, s uffix b a se c ata lo gn um b er w ith d e sir ed o p tio n.E x amp le : EDP4-ETD .

    NEMA SERIE

    DIMENSIONS:

    Prescolite Emergency Systems

  • 8/3/2019 Prescolite Emergency Systems ES-4 1992

    24/60

    EXPLOSION PROOFThe Prescolite EXP3 is designed specifically for Class I,Division I,Group C and 0 areas. The EXP3 is completely

    Features 120V input standard; 277V and240V available 6 volt maintenance free leadcalclurn battery standard; nickelcadmium and lead acid batteriesavailable: consult factory

    Automatic low voltage disconne High strength, copper free castaluminum housing Charger and battery compartmenhoused separately Vented battery compartment Lighl emitting pilot light that willburn out Protective explosion proof sealbetween battery and charger

    Plug in electronic card fo r easyreplacement

    Stainless steel on-of f test switch Sealed 25 watt lamps standard Fused protection Proportional charge rate

    self contained and provides continuous safe operationin the presence of volatile gases, vapors and dust.

    Options ElectricalBase EXPWG EXPDREF Output Watts AC Input StandardCatalog Output 1.5 2 3 4 lamp RemoteNumber REMEXP EXPEX Valls hrs. hrs. hrs. hrs. Volts Amps Watts Wattage Capability

    EXP3 6 75 57 38 30 120 ..5 30 25 YesCon su i t f a c io ry f or a v a il a b i l i ly 0 1 o t h er w a tl a ge sa nd o pt i on s.

    DIMENSIONS:

    Depth: 8"

    22 Prescolite Emergency Systems

    OPTION DESCRIPTIONEXPWQ: Wireguard.EXPDREF: Directional reflector.REMEXP: Remote explosion

    proof lamp and:lamphead.

    EXPEX: Unbreakable threesided exit to lit overlamphead.

    TO ORDER:Order base catalog numberEXP3. Order options as separateline itemExample: REMEXP.

  • 8/3/2019 Prescolite Emergency Systems ES-4 1992

    25/60

  • 8/3/2019 Prescolite Emergency Systems ES-4 1992

    26/60

    EXIT LITEsacrificing ruggedness. A variety of mounting and face-plate configurations are available, along with anExit Lite, a complete family of attractive injection moldedexits, features a clean, uncluttered appearance without

    Standard Sign Features High impact injection moldedhousing Steel faceplate standardwith knockouts for direc-tional arrows

    Tamper-proofing screwssupplied with housing One piece integra! down light 120V standard operation;277V available with module

    Two 140V 15T6 incan-descent. one 7W "PL" type ortwo 5W "PL" type lampsavailable; lamps supplied Exit Lite meets all emergencylighting and exit standards

    Available with factory assem-bled emergency light; seepage 26

    2% "3 1 , 4 ' , 1 - 1 --11"---11 IT[ ' - - - 1 - - - - - - - - - - . 1 DLEM,.------, Dr . - _E XO , E X1 , E X2 , E X3

    Stencil Style

    Emergency Features 6 volt, maintenance free leadcalcium battery High impact injection moldedhousing Dual voltage (120/277) ;separate module not requiredfor 277V operation

    Automatic low voltagedisconnect Two 3.7W DC lamps provideeven illumination inemergency mode

    Unit available in white orblack to match exit sign

    AC lockoutOpen Frame Style

    Open frame style exit is available withwhite fettars on a red or green back-ground. For other color requirements orspecial lettering, contact factory.

    Exit Lite avauable in au while or blackhousing with b lack or brushed a luminumfaceplate.

    EX3PL supplied with long life compactfI 1,10esce nl lamps,

    Transformer module for 277V application,spare faceplates and auxiliary socketsare just a few ofthe accessories availablein the Ex~ Lite family.

    24 Prescolite Emergency Systems

  • 8/3/2019 Prescolite Emergency Systems ES-4 1992

    27/60

    EXIT LITEemergency module and other accessories. Lampssupplied with all units.

    IncandescentSupplied with two 15W T6 incandescent lamps.Letter Stencil Open FrameDescription Colors Style Style CVS

    m I D Single Face R EXO-R N/ A No(back mount only) G EXO-G.[~ingle Face- Universal Mount R EX1-R EX1-WLR No(ceiling, back or end) G EX1-G EX1-WLGwin Face - Universal Mount R EX2-R N/A No(ceiling or end) G EX2-G.~ingle or Twin Face - Universal Mount R EX3-R EX3-WlR No(ceiling, back or end)' G EX3-G EX3-WlGl l f i i i t l Single or Twin Face- Universal Mount' R EX3-R EMFA EX3EMFA-WLR Yes(supplied with factory installed emergency modulet ) G EX3-G EMFA EX3EMFA-WLG~.

    U n il supp lied w ith two fac ep la ts s a n d back pjale. t EM (Emergency Module I i s avai la ble inCVS .

    FluorescentLetter CatalogDescription Colors Number

    Single or Twin Face - Universal Mount R EX3PLl-R.~ceiling, back o r end) 1 - 7W PL type lamp supplied' G EX3PL1-G, For 277V: Suffix TMFA. Unit will tie supp lied wi th factory at tached TMmodu le. Fo r emergency ope rat ion. su ff ix EMFA. Un it w il l be suppl ied w ith"120 /277V lac tory at ta ched EM moduleSingle or Twin Face- Universal Mount R EX3PL2-RQj (ceiling, back o r end) 2 - 5 W PL type lamps supplied' G EX3P~2-G, For 271V: Suf fix TMFA. Unit will be supplied wit h factor y attached TMmodule. For emergency operat ion , sul li x EMFA. Unit wil l be suppl iedwith 120V EM module factory auached, Contact tactory for ava ilab i l ily01 277V EM modute.

    Accessories (field installed)Catalog Catalog Catalog_D_es_c_rip_t_io_n N_u_m_be_r _Dffi_c_rip~t_io_n N_u_m_be_r _D~_c~riP_I_io_n N_um_be_rEmergency Module'For 120V or 277V operation EM90 minute ral ingTransformer Module'(For 277V supply)Converts s la nd a rd 1 1 OV Exil Litelor operation on 277V Circuits.Suffix TMFA for factory assembled.(Example: EX'-R-TMFA).

    TO " Stem and Canopy Kit Pl0Spare Faceplate - Red Letters SFRSpare Faceplate - Green Letters SF-GFlasher and Buzzer'Converts standard EM toftasher and buzzer. EM-'"2 DC Bayonet Sockets DCB Kit2 6V Wedge Base Sockets DCS Kit(Lamps included)

    2 12V Wedge Base Sockets DC12 Kit(Lamps included)Optional FinishesFo r black houSing wi th black tacepiate. suffixcaia log number wit h BLK. Ex . r np le 5 : EXO- RBlK, EM BLK. For bl ack housing with brushedaluminum taceptate, su lf i. c alalog number wi thBlK/SA . Example: EX1 -G BlKfBA .

    WireguardTM

    EWG3. For mcanoescem ana EX3Pl I exi lS . Refer above lor EX3P l2 order ing lntor rna tion .

    P re sc olite E me rge nc y S ys te m s

  • 8/3/2019 Prescolite Emergency Systems ES-4 1992

    28/60

    EMERGENCY LIGHT/EXIT COMBINA TIONThe EDX4 presents a unique labor saving opportunity.Install one fixture to perform the function of two. Unitpowers two auxiliary lamps in the exit and two erner-

    gency lampheads during an emergency. Standard unitis EX3 with factory installed EDS4. White unit standard.

    FeaturesExit Sign Supplied with two faceplatesand backplate Injection molded housing,steel faceplate Knockouts for directionalarrows standard

    Tamper-proofing screwssupplied One piece integral downlight Two 140V 15T61ampsstandard. Two 3.7W DClamps for emergency mode

    Choice of red or green lellers

    FeaturesEmergency Pack 6 volt, maintenance free leadcalcium battery Dual voltage (120/277) Automatic low voltagedisconnect Injection molded housing Labor saving snap togetherhousing Thermally protected Regulated charge voltage Reverse polarity protect ion Filtered charger output Shorl circuit protection Brownout protection AC lockout Ceiling mounting bracket

    Option Suffixes ElectricalBase Output Watts AC Input StandardCatalog Output 1 .5 2 3 4 Lamp RemoteNumber ECS EVl CVS EBC Volts hrs. hrs, hrs. hrs. Volts Amps Watts Wattage Capability

    EDX4 6 22 17 11 9 120 .200 24.0 7.2 No(R or G)' 277 _140 38.8'Choice 01Rea or Green leit ers. Specify EDX4R for Red l ett ers Or EDX4G l or Green teners,Con ta c t f a cto ry IO f ava i lab imy with compac l l1uo rescent l ar n pi s) . A l s o r emo te capab i li ty .

    Wireguard, remote heads andfixtures should be ordered asseparate line items. For detailson addit ional lampheads and ac-cessories see pages 50 and 51

    DIMENSIONS:

    16"--------,OPTION DESCRIPTIONECS: 3 foot cord setBlK: Black housing with black

    faceplate on exitBlK/SA: Black housing with

    brushed aluminumfaceplate on exit

    EWG 2: WireguardESC: Back cover (vinyl).Spec-

    ify color (white or black)CVS: Continuous Verification

    SystemEV1: Voltmeter

    12%"

    26 Prescolite Emergency Systems

    TO ORDER:Order base catalog numberEDX4(R or G). For options,suffix base catalog number withdesired option.Example: EOX4R-BLK.

  • 8/3/2019 Prescolite Emergency Systems ES-4 1992

    29/60

    Completely self contained, the Prescolite specificationgrade emergency exit features a stylish and unclutteredappearance. Rugged housing contains both the exit and-emergency system, giving the exit a clean appearance.6 volt maintenance free lead calcium battery and dualvoltage (120/277) transformer are standard.

    EMERGENCY EXIT

    Features 6 volt, maintenance free leadcalcium battery Dual voltage (120/277) Automatic low voltagedisconnect 22 gauge steel housing Two 20T6-1 /2 standardlamps Two 3.7V DC lamps providebroad, even illumination inemergency mode.

    Thermally protected Regulated charge voltage Reverse polarity protection Filtered charger output Short circuit protection Brownout protect ion AC lockoutOrdering Information

    Universal mount - Completeexit fixture includes hardwarefor ceiling mount, end mountor back mount

    Downlight standard Diecast aluminum trim andfaceplate

    Faceplate secured by twoinvisible torsion springs Universal arrows and tamper-proof knockouts

    Black housing and trim, whitefaceplate. Black and brushedaluminum faceplate available,contact factory Meets all emergency lightingand exit standards

    Stencil Style Open FrameFaceplates Red l e tt e rs Green Latter. White t.etters While leite"IithWhil~ withWhite w f 1hRed wllhGleRed L e ne rs Green Lellers Background Background Backgroond {l.ckgHlun

    Single FaceNo Arrow 87211 87212 87231 87232 87233 87234Universal Arrow 87221 87222 - - - -Arrow Left - - 87241 87242 87243 87244Arrow Right - - 87251 87252 87253 87254Double Arrow - - 87261 87262 87263 87264Twin FaceNo Arrow 87311 87312 87331 87332 87333 87334Universal Arrow 87321 87322 - - - -Double Arrow - - 87361 87362 87363 87364Arrow Left, Arrow Right - - 87371 87372 87373 87374

    AccessoriesCatalog

    De$!; r]pI ion NumberTrim Frame OnlyConverts Single Face to Twin 79115BLBackplate OnlyConverts Twin Face to Single 79123Pendant Stem AssemblyCanopy with Twin Stems 79124Replacement Lamp20T6-1/~/DC/IF Long Life 79117Replacement Emergency Lamp3.7W 6V Wedge Based Lamp ERLFlasher - BuzzerFlasher and/or Buzzer 79128

    DIMENSIONS:

    ~ r - - - - - - - - - r - - - - - - - ~ ~ ~ ~ - - - - - - - - , - 11W'lr_-----:J

    _J 3" LP re sc olite Em erge ncy Sys te ms

  • 8/3/2019 Prescolite Emergency Systems ES-4 1992

    30/60

    EDGE-LITThe EDGE-LIT Exit series util izes the light conductingproperties of thin, engraved Plexiglas@ panels and

    ,presents a clean, modern appearance. The light sourceis enclosed in a rugged diecast aluminum housing.

    Recessed units have diecaslaluminum Irims. Red, green orwhite engraved letters, 6" highx %" stroke on whirte or coloredbackground, conform to build-ing cedes, Clear panel with redor green letters on transparentbackground available for singleface units only. Unit uti lizespreheat ballasts for use withF8TS fluorescent lamps. Unitsavailable with one or twolamps, 120V or 277V. Singlelamp, 120V is standard. Singlelamp units operate on one cir-cuit, two lamps on two circuits.

    ER or ERT Ceiling Mount with Recessed Housing

    The EMERGENCY EDGE-LITseries incorporates the samefeatures as the standardEDGE-LIT, and suppliesemergency power to one lampduring a power interruption. Ahigh temperature resistantnickel cadmium battery is used

    I - 1 2% " rr - - - - - - - - - - - - - - - - - - - - ,DIMENSIONS:

    to ensure reliable performance.Test switch and indicator lightare easily accessible frombelow housing. Only availablefrom stock in recessed (catalogER, EAT) versions.

    1 4% "

    X IT 4 " - 1ER/ERT

    '6W' for emergency operat ion (ER/ERT -EME)

    28 Presco/ile Emergency Systems

    TO ORDER:To order complete units: Orderbase catalog number andsuffix with desired voltagedescription.Examples: ER6 (120/120),ERT-8D-EME (277).Clear panels with red or greenletters are available with allsingle faced units except endmount. Specify "clear" afterpanel number to order.Contact factory for availabilityof other voltages and specialpanels,

    The fol lowing lamps and voltages are available:

    LSuffix Dee crlptlon

    (120)' One 120V lamp (one olrcult)

    (120/120) Two 120V lamps (two circuits)

    (277) One 277V lamp (one circuit )

    (277/277) Two 277V lamps (two circuits)'120V sta ndard .

  • 8/3/2019 Prescolite Emergency Systems ES-4 1992

    31/60

    EDGE-.LIORDERING INFORMATION

    RedS" GreenS" WhileS" While 6"Letters Letters Letters Letterson While on White on Red on Green8/Ground B/Ground B/Ground B/Ground

    Ceiling Mount with Recessed Housing HOUSing OnJy ER or ERT1 I I T ~ Sing le FaceNo Arrow EA-S ER-7 ER-8 ER-9Complete Arrow Lett ER-SL ER-7L ER-8L ER-9LUnits Arrow Right ER-6R ER-7R ER-8R ER-SRDouble Arrow ER-60 ER-70 ER-SO ER-9D~ Twin Face

    Complete No Arrows ERT-S ERT-7 ERT-8 ERT-9Panel: l' 3" l onll x 7 y;" high Units Arrow left, Arrow Right ERT-alR ERT-7lR ERT-8LR ERT-9LRFin ish Opening Size: 141>" x 2%" Double Arrows ERT-SD ERT-7D ERT-80 ERT-90Housing Size: 2%" x 14~ x 3""" deep

    3'14"or 4" O.B. Mountingl i iU Sing le FaceNo Arrow EC-6 EC-7 EC.8 EG-9Complete Arrow Left EC-6L EC-7L EC-8L EC-9LUnits Arrow Right EC-6R EC-7R EC-SR EC.9RDouble Arrow EG-60 EC-70 EC-80 EC-90Twin FaceComplete No Arrows ECT-S ECT-7 ECT-8 ECT-9Units Arrow left, Arrow Right ECT-8lR ECT-7lR ECT-8LR ECT-9LRcanopy: 4 y , x 6" Double Arrows ECT-60 ECT-70 ECT-80 ECT-90OA Dimensions: 4\\" wide x 14" l ong

    Extends: 1t Y e" below ceiling

    Wall, End Mount for 3W' or'"OB~ Sing le FaceNo Arrow EW-6 EW-7 EW-8 EW-SComplete Arrow Left EW-6L EW-7L EW-8l EW-SL

    Units Arrow Right EW-6R EW-7R EW-SR EW-9R

    ~Double Arrow EW-60 EW-70 EW-SO EWSOTwin Face

    Complete No Arrows EWT-S EWT-7 EWT-B EWT-9Units Arrow Len, Arrow Right EWT-6LA EWT-7LR EWT-8LR EWT-SLRcanopy: 6" x 4Y, Double Arrows EWT-60 EWT-70 EWT-80 EWT-90OA Dimensions: 4~" wide x 11 Y a " high

    Extends: 14%" Iro m wal l

    Wall. Back Mount for 3\'

  • 8/3/2019 Prescolite Emergency Systems ES-4 1992

    32/60

    STANDARD PROFILE andTHINLINE EXIT

    , StenclIStyle Faceplate, UnlversaI A"ows

    Thinline Profile SeriesThe Thinline series exit featuresa 1)/2" ultra-slim sturdy diecaslaluminum housing. Each unit in-cludes two 20T6-1!2DC/IF incan-descent or two 7 Watt compact ilu-crescent long-li le lamps. Incan-descent version (120V) may bewired lor single or two circuit appli-cations. Housing are aile red in twostyles, a back-mount only ver-

    LOpen Style Faceplate, No Arrows

    '-----_Stencil Style Faceplate, No Arrows

    30 Ptescome Em e rg en cy S ys tem s

    sion and a universal mount withcanopy kit to create top, end orback mount as required. Downlightstandard. Invisibly - hinged diecastaluminum faceplates are standardwith tamper proof knockout. Stan-dard finish is white, also availablein all black or black housing with abrushed aluminum faceplate.

    Housing Single, face SlngltF8 Cll t....n-FaceBlick Muunt Universal MOLlnt Un iveraal Mount

    ,tncandescent 120V 76100 75200 75300277V 76200 76300Compact 120V 66100 65200 65300Fluores""nt 277V 66200 66300

    Standard Profile SeriesIncorporating the same mountingand construction features as theThinline series, the Standard Profi leoffers a choice of light sourcesfrom the 25 wall medium base in-candescent lamp, the eff icient,F6TS fluorescent lamp to the longli fe 5W compact fluorescent lamp.All housings accommodate two

    lamps for single or two circuitapplicat ions, 120V or 277V, and allhave integral wide downlighl 277Vuni ts incorporate two step downtransformers. Standard finish iswhi te, also available in all blackor black housing with brushedaluminum faceplate.

    Housing Single-Face Sinllia-Face Twln-FecaBack Mount Univ8rsal MOLlnt Unh.ersal Mount

    Incandescent 120V 71100 71200 71300277V 72100 72200 72300ftuore&eent 120V 73100 73200 73300277V 74100 74200 74300Compact 120V 81100 81200 81300Fluures""nt 277V 82100 82200 82300

    Recessed Profile SeriesThe Recessed Profi le exit featuresa recessed housing with a diecastt rim frame (flush mount ing trim op-lional). Each uni t includes two 15watt incandescent or two 7 wattcompact Iluorescenilamps.Housing Singl e-FDC8

    Rece5 ... dIncandescent 120V 71400

    277V 72400Compact 120V 66400flLlore&eent 277V 66400

    277V incandescent unit incorpo-rates a step-down transformer.Standard finish is white, alsoavailable in all black or black trimframe with a brushed aluminumfaceplate.

  • 8/3/2019 Prescolite Emergency Systems ES-4 1992

    33/60

    STANDARD PROFILE anTHINLINE EXIT

    Ordering GuideNumbers shown are face-plates only - combine withhousing number for completeunit Three styles of faceplatesavailable: Stencil without

    request, contact factory. Un-breakable polymer diffusers forminimum maintenance. No visi-ble fasteners, unique torsionbars provide positive spring-

    tension closure and hingedopening screws. Standardfinish is white. Also avail-able in black and brushedaluminum.

    arrows, stencil with snap-inuniversal arrows, and openframe, Standard 6" high x 3/4"stroke letters to meet O.S,H.A .codes. Special lettering onFaceplates Stencil Style Open Frame Style

    Red Letters Green Letters Red Letters! Green Letters/ White Letters/ White LettersWhite Bkgrnd. White Bkgrnd. Red Bkgrnd. Green BkgrndNo Arrow 70011 70012 70031 70032 70033 70034Universal Arrow 70021 70022Arrow Left 70041 70042 70043 70044Arrow Right 70051 70052 70053 70054Double Arrow 70061 70062 70063 70064Arrow Left, Arrow Right ' 70071 70072 70073 70074

    T win -F ac e o nly : C ata lo g n um be r to o rd er fa ce pla te s w /A rro w L e ft a nd w /A rro w Right.F or u se w /T w in -F ac e U niv er sa l M o un t.Accessories Catalog Description(Customer Applied) NumberPendent Stem Assembly 7911' ForUniversal MountStandard ProfileHousings. Also Availablewith 120VIncandescent12" Std. Universal MountThinline Housing.Emergency Light Socket 79112 For 120V Incandescent Thinline Unitsor Incandescent StandardProfileUnits. FactoryDouble Contact Bayonet InstallationRecommended.Contact Factory for Field Installation.Downlight Mask' 79114 ForThinline.79113 For Standard ProfileOuter Trim Frame only' 79115 For RecessedBackplate only" 79116 ForSingle-Face Universal Mount, ConvertsTwin-Face Housing,Flush Rough-in Kit 79122 Adapts Back Mount 120VThinline Exitto 277VContains TwoStep DownTransformers(277Vto 120V)Suitablefor Two Circuit Applications.Converter' 79129-1 Reduces Single277Supply to 120Vfor Surface Mount Thinline Exits.Increases UniverCanopy Depth to 1~a".Wireguard EWG3 For Standard ProfileWireguard EWG5 ForThinlineWireguard EWG6 ForRecessedTrim Frame-Flush Mount' TF1 ForRecessed

    . Spec i ty Colo r F or a dd ilio na l a cc es so rie s - C o nta ct F ac tHow to Specify Complete Units1. Select required housing catalognumber (opposite page).Example:Incandescent, 120V,Twin-face Universal Mount -71300

    2. Select desired faceplate catalognumber (above).Example:Open faceplate, redonwhile, noarrows - 70031

    3. Combine housing and faceplatecatalog numbers.Example:Completecatalog number -71331Note: Housingsor faceplates canbe specified separately byindividualnumbers indicated,

    To Specify Finish:W- All WhiteB - All BlackB/BA - Black housing withBrushedAluminumfaceplatePrescolite Emergency Systems

  • 8/3/2019 Prescolite Emergency Systems ES-4 1992

    34/60

  • 8/3/2019 Prescolite Emergency Systems ES-4 1992

    35/60

    DIECAST EMERGENCYEXIT SERIESOrdering Information: 9 wEC21

    I EmergencylRemoteCapability

    BaseNumber

    LampTypelVoltage Housing Faceplate Finish

    7-Singte faceuniversal mount8Twinfaceuniversal mount '-1\1-SlngI9face 11thru 74back mount.:I2.Slngl8faceceiling mountA3-Singlefaceend mountA4-Twinfaceceiling mount

    A5-Twinfaceend mount 6-Recessed

    W-AllwhrteB-All blackBlBABlack hsg.with brushedaluminum facplate

    -~EC-Emergency w~hlead calciumbatteryEN-Emergencywith NicadbatteryRC-Remotewithlead calc!urnbatteryRN-Remote withNicad battery

    , I-Incandesce nt 120V 2-'lncandescentZl7V3-PL 120V (2-7W)4-PL 277V (2-7W)

    Furnished with two (2) 20T6'12DCIIF long life lamps(surface mount) or two (2) 15T6'f2 lamps (recessed).a FactoryAssembled... For completely flush design, order tlim frame separatelyas (TF1), specify color.Note: Canopy is not field installable on non emergency extts

    Faceplate Codes Faceplates Stencil Style Open Frame StyleRed Gree!1 Red lillIe"" GreooLett"rSI Whn" Le1tersl Wh l te L a t te r s!Le i te rs Le t te rs WMe Bkgmd. Wh il e B kgm d. Red Bkgmd GteM Bkgmd.Threestyles of faceplates available: Stencilwrthout arrows, stencil with snap-Inuniversa.! No Arrow 11 12 31 32 33 34arrows, and openframe. Standard 6" highx

    3 /. " stroke letters to meet O.S.H.A. codes. Universal Arrow 21 22Special lettering on request, oontact factory.Unbreakable polymer diffusers for minimum Arrow Left 41 42 43 44maintenance. No visible fasteners, uniquetorsion bars provide positive sprlng-tension Arrow Right 51 52 53 54closure and hinged opening.Stencil Styleis available in a white, black orbrushed aluminum faceplate. Double Arrow 61 62 63 64Arrow Left, Arrow Right' 71 72 73 74' "T w in - F ac e On l y

    To order a faceplate only. prefix "700"to the two digit faceplate code shown above. Example: 70011 - a stencil style faceplate with red lettersand no arrows. Must specify if a faceplate is to be used on a recessed emergency unit, suffix RE (Example: 70011-RE).Remote CapacityAll incandescent exits ordered with remote capability have 7.5 watts of remote capacity. Surface mount compact fluorescent exits have 15 wattof remote capacity (Double Canopy required). If more remote capacity is required, contact factory.

    Accessories Catalog Description(Customer Applied) NumberDownllght Mask 7 9 1 1 4 For ThinlineOuter Trim Frame OnlY" 7 9 1 1 5 For RecessedBackplate Only 7 9 1 1 6 For Single-Face Universal Mount, Converts Twin-Face HousingWireguard EWG6 For RecessedTrim Frame - Flush Mount" TFI For Recessed

    , Specify colorContact factory if addit ional accessories are required

    Presco/ite Emergency Systems 3

  • 8/3/2019 Prescolite Emergency Systems ES-4 1992

    36/60

    ELECTROLUMINESCENTEXIT SERIES

    Dimensions:Surface Mounting Exit: Thinline hous-ing may be back, top or end mounted.Available in AC Of with fully integratedemergency system (sa.me dimensions).

    Surface Mounted Exit1"

  • 8/3/2019 Prescolite Emergency Systems ES-4 1992

    37/60

    ELECTROLUMINESCENTyears and provide unequaled uniformity. Exits are avail- EXIT SERIESable for standard or emergency operation for surface orrecessed installation. Emergency exits are completelyself contained.Ordering Information

    EL 1 2 1 EN BI

    HousingI

    VoltageI I I

    l_Finish

    1-120V2-277V4-i20/i.20V5-277/277V

    1-5ingle faceback mount2-Single faceuniversal mount3-Twin faceuniversal mount4-Recessed

    EmergencylRemoteCapability"LetterColor Arrows

    5-Multi-mount Back mount('/8" depth) Semi-recessed(5/e" depth) Fully recessed

    l_ l_ l_ l_I-Red2-Green

    I-No arrow2-Arrow left3-Arrow rightt4-Arrow left,arrow right5-Doublearrows6-Universalarrows

    W-AII whiteB-AII blackBIBA-Black hsg.with brushedaluminum face-plate

    Blank-No emergencyor remote,."EN-EmergencyNicad battery,."RN-Remote withNicad batte ry

    , Available as a non-emergency exit or as a 'slave' unit in emergency situations wilenused witha 'master' exit with remote capability.Available in 120V and 120/120V only.Fully recessed version (flush), order trim frame separately as (TF1), specify color.t For!win face only.i'l COntactfactory for availabifity in twin circuit.

    Universal arrowso arrow Arrow left Arrow right Double arrows

    To Order Faceplate Only:1

    1 c + t s 1I-Singlecircuit

    z-Twlncircuit

    ELSF - 1 1E=:r-~IHQUSing I I Letter IType I Color1- For uslith l - R Lhoosingtypes 2-Green1.2. and 3 ( fromlistabove)

    2- For use w~hhousingtypes4 and 5 (f romlistabove)

    3 B

    I A r ~ l l + h ll-N 0 arrow W-A11 wI 1 ite2-Arrow left BAII Bfack3-Arrow right BA-Brusl'led5-Double arrows Aluminum6-Univsrsal arrows

    Accessories Catalog(Customer Applied) Number DescriptionDownlight Mask' 79114 For Thinline - surface mountOuter Trim Frame Only' 79115 For RecessedBackplate Only' 79116 For single-Face Universal Mount, converts twin face housingWireguard EWG5 For Thinline - surface mountWireguard EWG6 For RecessedTrim Frame - Flush Mount' TF1 For Recessed and Multi-Mount Specify color (white or black)Note: See page 52 tor vandal resistant shield information.

    Prescollte Emergenoy Systems 3

  • 8/3/2019 Prescolite Emergency Systems ES-4 1992

    38/60

    FLOOR PROXIMITYDIECAST EXITIn addition to electroluminescent exits, a remotecapable diecast emergency exit (incandescent orcompact fluorescent) can be used with a recesseddiecast emergency exit at floor proximity

    Am0

    B, E X I T

    36 Presco/iteEmergencySystems

    Life SafetyWhen smoke rises during afire, the density of the smokemay block the visibility of theexit above the door. Floorproximity exit signs greatlyincrease the ease of egress inemergency situations.ApplicationRemote capable electrolumi-nescent exit above the doorpowers and controls theelectroluminescent at floorproximity in both AC andemergency mode. Therecessed or highly flexiblemulti-mount exit can be usedat floor proximity. The multi-

    A). Electroluminescent exitwith remote capability.(Example: EL1211-RN-W) Diecast emergency exilwith remote capability.(Example: 92712-RC-B/BA

    B). Electroluminescent exit- Surface mount(Example: EL1211-W)- Recessed(Example: EL1411-W)- Multi-mount(Example: EL1511-W)

    Diecast emergency exit- Recessed only (can beflush mounted)(Example: 72412-B/BA)

    mount exit is available as asurface mount exit ( 7 /8' thin),semi-recessed (W' thin) orfully recessed (flush). Optionalvandal resistant shield isavailable on recessed ver-sions (see page 52 fordetails).

  • 8/3/2019 Prescolite Emergency Systems ES-4 1992

    39/60

  • 8/3/2019 Prescolite Emergency Systems ES-4 1992

    40/60

    IPS SERIESOff Line Interruptible Power System for Incandescent, Fluorescent,LED and Electroluminescent Emergency Lighting Systems

    DIMENSIONS:Meter Panel

    Door Locks

    INVERTER CABINET BATTERY CABINET

    38 Prescolite Emergency Systems

    Features Maintenance free lead cal-cium batteries Sine wave output

    97% eHiciency 30 min. MTTR Internal component redun-dancy Only front access requiredfor service

    Ferroresonant technology re-duces circuit complexity. Theinverter uti lizes internal tran-sistor redundancy which willallow up to 20% of the powerswitching transistors to failand still provide full load out-put power. This combinationachieves a rel iability recordand is envied within the indus-try. These are floor and/or wallmounted convection-cooledinverter units mounted inheavy gauge sheet metal cab-inets with front-opening, key

    90 minute battery run time Single phase:500VA - 16.7kVA Three phase:7200VA - 50kVA New York City approved UL Listed 924 Electronic warranty - 2 years

    locked doors. The cabinetscontain air louvers and knock-outs for interwiring with BX ,Romex, or conduit. The inter-nal construction of each cabi-net consists of battery char-ge r, D C to AC inverter, andbatteries. Above 4kVA, a sep-arate battery cabinet is re-quired. 4kVA and below hascharger, inverter, and batter-ies all self contained within thecabinet for up to 1 1 / 2 hours ofemergency run time.

    ORDERING INFORMATION1. Specify type of system: IPS, FT, UPS, or CoUPS2. Specify VA rating3. Specify battery type: SLC - Sealed lead calcium

    LA - Wet lead antimonyLC - Wet lead calciumNC - Wet nickel cadmium4. Specify input voltage

    5. Specify output voltage6. Specify options, if any(see page 48)

  • 8/3/2019 Prescolite Emergency Systems ES-4 1992

    41/60

    "

    IPS SERIES

    CATALOG NUMBER IRATING/MECHANICAL SPECIFICATIONSIPS Cabinet Dimensions IPS WI. Battery' Cabinets Each

    Net WI. oCatalog VA Mu.UUI. System Hea.t Including B~ery Battery Battery No. o f Ea. Add'iNumber Rating Input Effie. loss (A) (8) (Cl Batteries Voltage CUrrent RunTime (0) (E) (F) Battery CablnellCurrenllO % BTU's Width Height Depth IbsJkg VD C Ampera MilL Width Height Depth Cabinet Batt"riesIn/em In/em In/em in/em In/em In/em IbsJkg

    IPS500-SlC-1' 20-120 500 6 97 150 421107 36,5/93 12130 3511160 24 32 90IPS 750SLC-120-120 750 8 97 150 421107 36.5/93 12130 4421200 24 48 90IPS-1000-SLC-120-120 1000 11 97 150 421107 48,5/30 12130 4851220 36 40 90 -IPS-1250-SLC-120-120 1250 13 97 150 421107 60. 5/153 12/ 30 5781263 36 50 90IPS-1500SLC120120 1500 15 97 150 421107 48.51123 12130 6841311 48 42 90IPS-2000SLC120120 2000 20 97 150 421107 66.51174 19146 1'000/455 54 50 90IPS-2400SLC120-120 2400 24 97 150 421107 68.51174 19/48 11461455 36 97 90IPS3000SLC120-120 3000 30 97 150 421107 66.51174 19146 11561526 48 85 90IPS-3600-SLC-120120 3600 35 97 150 421107 66.51174 19146 12751580 54 90 90IPS-4000-SLC-120120 4000 39 97 150 421107 66. 5/174 19146 14151643 54 100 90IPS-4500SLC120-120 4500 45 97 300 42.1107 621156 19/48 550/250 48 128 90 42.1107 61:.51156 19/48 1 14551661IPS-5000-SLC120120 5000 50 97 300 421107 621156 19148 5801264 54 125 90 421107 61.51156 19148 1 1429/650IPS-SOOO-SLC120120 6000 58 97 300 421107 621156 19/48 5901269 54 150 90 421107 61.51156 19148 1 1429/650IPS-7500SLC-120-120 7500 80 97 500 421107 621158 19148 6101277 54 188 90 42.1107 61.51156 19/48 2 1429/650IPS10000SLC-120-120 10000 100 97 500 421107 62115S 19148 7501341 60 228 90 421107 61.51156 19148 2 1555/707IPS12500-S LC-120-120 12500 125 97 500 .421107 821158 19148 6751398 72 240 90 421107 69.51177 19148 2 1687/767IPS16700-S LC-277 -277 16700 "76 97 500 421101 82/158 19148 9981454 120 180 90 4:21107 49.51128 19148 2 1320160

    Three Phase available upto 50kVA by using 3 each of any single phase part number shown above phase locked together.NOTE: Uni ls 4.SkVA-16.7kVA batteries are external, SOOVA- 12.5kVA 120VAC inloutis standard. "16.7kVA 277VAC in/out is standard.

    ELECTRICAL SPECIFICATIONSINPUT

    Input voltage: 120 VAC + 1015%.Other voltages available onrequest.

    Input power walk-in: 2 cycles,which limits the inrush current fromthe ut ility to 125% maximum.

    Input frequency: 60Hz 3%(50Hz available on request). Input transfer voltage: Brownout,transfer to inverter @ 85% uti li tyinput. Transfer back to utility @90% input vol tage.

    OUTPUT Output voltage: 120 VAC. Othervol tages avai lable upon request. Output regulation (statio): Loadcurrent changes. 4%, batterydischarge 4%.

    SYSTEM OPERATION1. An input high isolat ion ferroresonanttransformer provides power to asolid state rectifier/charger which inturn creates a regulated DC supply.This supply charges the bat tery.

    2. A battery is provided to maintainpower to the inverter. The battery isfitted with a suitably rated fuse toprovide over-load and short circuitprotection.

    OUTPUT Output regulation during emer-gency (dynamic): 3% for a 25% load step change. 6% fora 50% load step change, recoverywithin 3 cyc les.

    Load power factor: ,75 lag to ,9lead. Output frequency: Normally, syn-chronized to uti li ty, 1% duringemergency (50Hz available uponrequest),

    Output distortion: 10% THO linearload. Time to transfer to Inverter aftera utility power failure: 50MS_

    Line 10 line vol1age unbalance(a-pnase units only): 4% for a30% line to line load balance.

    3. A ferroresonant t ransis tor ized sta ticinverter transforms the battery en-ergy into a regulated sine wave ACvoltage to supply the critical loac.

    4. An e lectro/mechanica l t ransfe rswitch connects the load to eitherthe u ti li ty dur ing normal operat ionor the inver te r during emergencyoperation.

    BATTERY Standard baHery: Sealed leadcalcium.

    CHM baHery charger: Automaticboost charge (equal ize) is appl iedwith a SOl id -s tate t imer approx i-mately every 3 months. Tricklecharge app lied constant ly , Internalgreen, yellOW, and dual red LEDmode indicators supplied on eachcharger. Automatic low bat tery volt-age d isconnect . Automat ic restar tupon ut i l ity return,

    Recharge time: 24 hours, PerUL 924. Optional: Extended run timesavailable, consult factory.

    PHYSICAL Operating temperature: O'C to40'C (32"F to 104F). Cont inuousoperat ion at high ambient tern-peratures shortens battery lif e.

    Relative humidity: 95% non con-densing, Front panel controls group:Battery DC voltmeter. Output ACvoltmeter. Green utility power OKindicator . Amber h i-charge ind i-cator . Bat te ry charge ammeter .System test swi tch,

    Options: See page 48.

    A CPowerOutpu

    UtilityPower Line

    Presco/ite Emergency Systems

  • 8/3/2019 Prescolite Emergency Systems ES-4 1992

    42/60

    FT SERIESOn Line Uninterruptible Power System for Incandescent,Fluorescent and H.I.D. Emergency Lighting Systems

    DIMENSIONS:Meter Panel

    Door Locks

    TE

    , _ _ , _ _ _ _ _ , P 1b

    FTCABINET BATIERY CABINET

    40 Prescolite Emergency Systems

    Features Maintenance free lead cal-cium batteries

    Sine wave output Internal component redun-dancy Only front access requiredfor service 80 DB transverse modenoise reduction 120 DB common modenoise reduction Low input current distortion

    Be ready for virtually anyemergency ... with this unin-terrupt ible power system. Thispulse width modulated inverterut ilizes internal transistor re-dundancy which will allow upto 20% of the power switchingtransistors to fall and "still pro-vides full load output power".

    Input power factor - 85 tounity 90 minute battery run time

    Low input current distort ion6%

    90% eff iciency 50% overload capacity 30 min. MTTR 3kVA-16.7kVA Digital metering UL Listed 924 Electronic warranty - 1 yearThe AC in to AC out operatingefficiency is 90%, well abovethe average UPS. The internalconstruction of each cabinetconsists of an AC to DC bat-tery charger, DC to AC inverterand energy storage trans-former, and sealed lead cal-cium batteries.

    ORDERING INFORMATION1. Specify type of system: IPS, FT, UPS, or C-UPS2. Specify VA rating3. Specify battery type: SLC - Sealed lead calcium

    LA - Wet lead antimonyLC - Wet lead calciumNC - Wet nickel cadmium

    4. Specify input voltage5. Specify output voltage6. Specify options, if any(see page 48)

  • 8/3/2019 Prescolite Emergency Systems ES-4 1992

    43/60

    FT SERIE

    CATALOG NUMBER IRATING/MECHANICAL SPECIFICATIONSFr cabinet DIraensfcna Battery Cabinets Each Nel WI.

    Catalog VA Max. Util. System Heat Net BBtler y Ballery Battery No. 01 Ea. AddNumber Rating Input Effie. Loss (A) (B) IC) Weight Voltage Currenl RunTime (D) (E) (F) Bane

  • 8/3/2019 Prescolite Emergency Systems ES-4 1992

    44/60

    UPS SERIESTrue On Line, No Break Uninterruptible Power Systemfor Incandescent, Fluorescent and H.I.D. EmergencyLighting Systems

    DIMENSIONS:MeterPanel

    Door Locks

    TE

    !,---......L-P _ _ _ . 1I--D-l -iFf-o:

    UPS CABINET BATTERY CABINET

    42 Prescoiite Emergency Systems

    Features Maintenance free lead cal-dum batteries Sine wave output Internal component redun-dancy Only front access requiredfor service Lew input current dlstortlon6% Input power factor - 85 tounity

    Ferroresonant technology re~duces circuit complexity. Theinverter utilizes internal tran-sistor redundancy which willallow up to 20% of the powerswitching transistors to fail,and still provide full lead out-put power, This combinationachieves a rellablllty recordsuperior to that of any etherUPS manufacturer. These arefloor-mounted, forced-cealedUPS units which require front

    140 DB transverse modenoise reduction 90 minute battery run time 1000VA to 10kVA.30 min. MTTR Continuous run High lightning immunity UL Listed 924 Electronic warranty ~1 year

    access only for servicing. Cabi-nets contain air filters andknockouts for interwiring withex, Romex, or conduit. Internalmodule construction consists ofbattery charger, AC to DC con-verter, DC to AC inverter, andbatteries. Above 1,5kVA, aseparate battery cabinet is sup-plied. 1.5kVA and below has acharger, inverter, and batteriesall self contained within thecabinet.

    ORDERING INFORMATION1. Specify type of system: IPS, FT, UPS,.or CoUPS2. Specify VA rating3. Specify battery type: SLC - Sealed lead calciumLA - Wet lead antimonyLC - Wet lead calciumNC - Wet nickel:cadmium4. Specify input voltage5. Specify output voltage6. Specify options, if any(see page 48)

  • 8/3/2019 Prescolite Emergency Systems ES-4 1992

    45/60

    UPS SERIES

    CATALOG NUMBER !RATING/MECHANICAL SPECIFICATIONSUPS Cabinet Dime ....lons Bat tery Cab inets Each Net WLo!

    Catalog VA Max.Ut ll. System Heat UPS BaIIery S8IIefy S_ry No.o! Eo. Add"Number Rating Input Ellie. Loss (A) (B) (C) Weight Vollage Current Runnme (D) (E) (F) Battery Cabinet!Current % BTU's Width Height Depth Ibs.lkg VDC Ampers MIn. Wiolh Height Depth Cabinet Batteries

    In/em In/em In/em Inlem In/em in/em Iba.lkgUPS1000-SLC-120120 1000 17 75 900 421107 49.51128 12130 6751307 46 26 90 -UPS1500-SLC-120-120 1500 25 75 1300 421107 61.51156 12130 950/432 46 43 90 - -UPS-3000-SLC-120-120 3000 50 75 2700 421107 61.51156 19/46 775/352 46 85 90 421107 50/127 19/48 1 611f369UPS-4500SLC-120-120 4500 75 75 4000 421107 69.51177 '9148 885/402 46 126 90 421107 62/158 19/46 1 1271/578UPS-6000-SLC-120-120 6000 100 75 5500 42/107 69.51177 19/48 1005/457 46 170 90 421107 62/158 19148 1 1566/710UPS-7500SLC-120-120 7500 125 75 6800 421107 69.51177 19148 1175/534 48 213 90 421107 70/178 19146 1 '820/828UPS-10000-SLC-' 20-120 10000 166 75 9000 421107 69.51177 19148 1225/557 60 227 90 42107 62/'58 19148 2 1260/573

    ELECTRICAL SPECIFICATIONSINPUT

    Input voltage: 120 VAC 20%.Other voltages available onrequest.

    Input power walkin: 2 cycles,which limits t.he inrush current fromthe ut ility to 200% maxirnum.

    Input frequency: 60Hz 5%(50Hz available on request) . Synchronizing slew rate: 1 Hz persecond nominal. Input/output noise reduction:140 DB transverse mode. Input current distortion; 6% atfull load nominal line.

    OUTPUT Output voltage: 120 VAC.Other voltages available uponrequest.

    SYSTEM OPERATION1_ An input h igh isolat ion fer roreso-nant transformer provides power toa solid state rectifier which in turncreates a regulated DC supply.This supply provides the powerrequirements for the continuouslyrunning inverter.

    2. An input isolation ferro resonanttransformer provides power to asolid state reclifier/charger which inturn creates a regulated DC supply.This supply charges the battery.

    3. A sealed maintenance free batteryis provided to maintain power to theinverter during a mains failure. The

    OUTPUT Output regulation (static): Inputvariations 1%, load currentchanges 2%, battery discharge2%.

    Output regulation (dynamic): 6% for a 25% load step change. 12% for a 50% load step change,recovery within 3 cyc les.

    Output distortion: 5% THO linearload. Load power factor: .75 lag to .9lead. Output frequency: Normally, syn-chronized to u ti li ty , .05% duringemergency (50Hz available uponrequest).

    Overload: 130% for 5 min. Time to transfer to inverter aflera utUity power failure: None. Trueon l ine system.

    battery is fitted with a suitably ratedfuse 10 provide overload and shortcircuit protection.4. A ferroresonant transistorized staticInverter t ransforms the DC voltagecoming from either the rectifier orthe battery into regulated AC volt-age to supply the critical load.

    5_ An electro /mechan ical au tomat icbypass switch connects the loadnormally to the inverter. In the caseof Inverter failure or voluntary shut-down, the load is connected to theutility.

    BATTERY Standard battery: Sealed leadcalcium. CHM Battery charger: Automaticboost charge (equa lized) is app liedwi th a SOl id -s tate t imer approxi -mately every 3 months. Trickle LEDmode indicators supplied on eachcharger.

    Recharge time: 24 hours. Per UL924. Battery protection: Automatic lowba t te ry vo Itag e dis con nect, Auto-rna tlc restar t upon ut il ity return. Optional: Extended run timesavailable, consult factory.

    PHYSICAL Operating temperal~re: OC to40'C (32F to 104-F). Continuousoperat ion a t high ambienttempera tu res shortens bat tery l ife

    Relative humidity: 95% non con-densing. Front panel controls group:Battery DC voltmeter. Output ACvoltmeter. Utiljty power OK indi-cator . Inverter bypassed indica tor .Bat tery charge ammeter. Hi-chargeind icator . Systems test swi tch.

    Automatic bypass switch: Uponan inverter failure, the AC utilityautomat ically transfers to the loadwith a mechanical switch within 3seconds. (Fast solid-state 2ms.swi tching avai lable on specia lrequest. Request SBYP option.)

    Options: See page 48.

    UtilityPower L ine\ Emergency By-Pass Line~----~~--~~

    ACPoweOutpu/

    Prescoiite Emergency Systems

  • 8/3/2019 Prescolite Emergency Systems ES-4 1992

    46/60

    C-UPS SERIESTrue On Line, No Break, Uninterruptible Power Sys-tem for Mini Computer Systems

    DIMENSIONS:Meter Panel

    Door Locks

    CUPS CABINET BATTERY CABINET

    44 Prescolite Emergency Systems

    Features Maintenance free lead cal-cium batteries Sine wave output

    Internal component redun-dancy Only front access requiredfor service Low input current distortion6% Input power factor - 85 tounity 140 DB transverse modenoise reduction

    Ferroresonant technology re-duces circuit complexity. Theinverter util izes internal tran-sistor redundancy which willallow up to 20% of the powerswitching transistors to failand still provide full load out-put power. This combinationachieves a reliabili ty recordand is envied within the indus-try. These are floor-mounted,forced-cooled UPS unitswhich require front access

    New York City approved#88A0429 Long emergency run timesavailable

    1000VA to 10kVA 30 min. MTTR Continuous run High lightning immunity Seismic Zone 4 certified CSA Listed (3kVA only) UL Listed 1012 Electronic warranty - 2 years

    only for servicing. Cabinetscontain air filters and knock-outs for interwiring with BX,Romex, or conduit. Internalmodule construct ion consists ofbattery charger, AC to DC con-verter, DC to AC inverter, andbatteries. Above 3kVA, a sepa-rate battery cabinet is supplied.3kVA and below has a charger,inverter, and batteries all selfcontained within the cabinet.

    ORDERING INFORMATION1. Specify type of system: IPS, FT, UPS, or C-UPS2. Specify VA rat ing3. Specify battery type: SLC - Sealed lead calcium

    LA - Wet lead antimonyLC - Wet lead calciumNC - Wet nickel cadmium

    4. Specify input voltage5. Specify output voltage6. Specify options, if any(see page 48)

  • 8/3/2019 Prescolite Emergency Systems ES-4 1992

    47/60

    C-UPS SERIES

    CATALOG NUMBER /RATING/MECHANICAL SPECIFICATIONSx x x C-UPS Cabinet Batte.ry ClIbi nat .. Ese h Net WI . 0Dimens.lons X X Ea. Add'iCatalog VA Max. Utll. System Heal CoUPS Battery Battery No. 01(A) (S ) (C) Weight Batt" 'Y (D) (E) (F) Battery CablneUNumber Rallng Input Ellie. Loss Voltage Cu.... nt RunTimeWidth Height Depth IbsJkg Width Height Depth Cabl",,' BalterlesCurrent % BTU's Infem infem Infem VDC Ampers Min. Inlcm in/em Infem IbsJkg

    CUPS-l000SLC'20-120 1000 17 75 900 421107 621156 12130 5751261 48 23 30 NoneCUPS-1S00SLC120-120 1500 25 75 1300 421107 621158 12/30 6501295 48 34 25 - NoneC-UPS3000-SLC-120-120 3000 50 75 2700 421107 70/178 19/48 875/398 48 68 15 Nonec-u PS450Q-SLC-l 20 120 4500 75 75 4000 421107 701178 19/48 885/402 48 102 15 32181 33184 12130 I 310/141C-UPS-SOOOSLC-120-120 6000 100 75 5500 421107 701178 19148 1005/457 48 136 12 32161 331M 12/30 I 342/156C-UPS-7500SLC I20120 7500 125 75 6000 421107 701178 19148 11751534 48 170 15 32181 33184 12130 1 4501205C-UPS-l0000SLC12Q-120 10000 166 75 9000 421107 70/178 19/48 12251557 60 181 15 421107 501127 12/30 1 5651257

    Note: Units 4.5kVA - 10kVA batter ies are extemal."X @ .8 power factor.All units shown on this page have an Increased output rating of 10% when operat ing at .8 power factor lagging .

    Example: Catalog No. C-UPS-l0oo0-SLC-12O-120 as shown in the above chartwil l supply 11.000VA max.La nger batl"r~ ru n 11mes ava iable:

    1000VA (45, 60 or 120 minutes) IS00VA (SO and 60 minutes) 4500VA (30 minutes)

    ELECTRICAL SPECIFICATIONSINPUT

    Input voltage: 120 VAC 20%.Other voltages available onrequest. Input power walkin: 2 cycles,which limits the inrush current fromthe utility to 200% maximum. Input frequency: 60Hz 5%(501;lzavailable on request). Synchronizing slew rate: 1 Hz persecond nominal. InpuUoutput noise reduction:140 DB t ransversa mode. Input current distortion: 6% atfull load nominal line.

    SYSTEM OPERATION1. An input high isolation ferroreso-nant transformer provides power to8 solid state rectifier which in turncreates a regulated DC supply.This supply provides the powerrequirements of the inverter.

    2. An input isolation ferro resonanttransformer provides power to asolid state rectifier/charger which inturn creates a regulated DC supply.This supply enarpes the battery.3. A sealed maintenance free batteryis provided to maintain power to theinverter dlJring a mains failure. The

    OUTPUT Output voltage: 120 VAC.Other voltages available uponrequest. Output regulation (static): Inputvariations 1%, load currentchanges 2%, battery discharge2%. Output regulat ion (dynamic): 6% for a 25% load step change. 12% for a 50% load step change.recovery within 3cycles. Output distortion: 5% THO linearload. load power factor: .75 lag to .9lead. Output frequency: Normally, syn-Chronized to ut.ility, .05% duringemergency (50Hz available uponrequest]. Overload: 130% for 5min.

    battery is fitted with a suitably ratedtuse to provide overload and shortCircuit protection.4. A ferroresonant transistorized staticinverter transforms the DC voltagecoming from either the rectifier orthe battery into regulated AC volt-age to supply the critical load.5. An electro/mechanical automaticbypass switch connects the loadnormally to the inverter. In the caseof inverter failure or voluntary shut-down, the load is connected to theutility.

    BATTERY Standard battery: Sealed leadcalcium. CHM Battery charger: Automaticboost charge (equalized) is appliedwith a solid-state timer approxi-mately every 3months. Trickle LEDmode indicators supplied on eachcharger. Recharge time: 4 to 8 hours. Battery protection: AutomatiC lowbattery voltage disconnect. Auto-matic restart upon utility return.

    PHYSICAL Operat ing temperature: OCto40'C (32'F t0104-F). Relative humidity: 95% non condensing. Front panel controls group:Battery DC voltmeter. Output ACvoltmeter. Utility power OK indi-cator. Inverter bypassed indicatoBattery charge ammeter. Hi-charindicator. Systems test switch.

    Autometic bypass switch: Upoan inverter failure, the AC utilityautomatically transtsrs to the loawith a mechanical switch within 3seconds. (Fast solid-state 2ms.switching available on specialrequest. Request SBYP option.)SBYP option reduces the AC inpto AC output noise reduction. Options: See page 48.

    UtilityPo_rUne\ Emergency By-Pass Line~-----=;.......;;__::_--~-.

    ACCompuGradePOWef"Output

    Pr8scolite Emergency Systems

  • 8/3/2019 Prescolite Emergency Systems ES-4 1992

    48/60

    PR-232DIAGNOSTIC INTERFACE OPTIONOptional remote or local computerized supervision ofyour Prescolite IPS, FT, UPS or C-UPSinverter system

    Battery

    PR-232

    The foUowing information is supplied to the host computer as aOne Line Status Report:Input Status: Displays "Good" or "Fail", good if utility power is withinacceptable vo.ltage/frequency limits.,Load Volts: Displays system AC output voltage.Load Amps: Displays system ACoutput current.Load Power: Displays product of Load Volts and Load Amps(volt amps).Input Volts: Displays utility ACinput voltage.Input Frequency: Displays utility frequency.Battery Volts: Displays battery buss voltage.Temp ..: Displays internal ambient temperature of UPS cabinet indegrees centigrade.

    # of Util. Fail.: Displays 10ta:1number of utility power failures andbrownouts ..Total Disch. Min.: Displays total time the UPS has operated frombattery backup power.Total Unit 'Hours: Displays tolal operating' hours on syslem.# of Overloads: Displays total number of times load power demandexceeds UPS futl power output rating.Disch. Min. Avail.: Displays an estimation of battery backup time

    a.vailable in normal mode of approximatetv howlong' system will continue to operate if in batterybackup mode.

    455 20 25 30 35 40DISCHARGE TIME (MINUTES)

    60

    SYSTEM SATTERY PERFORMANCE5654

    f.ii 53I- 52-'0G 51L J . l 50(!l-c 49~ 480:: > 47. .II: 4611l1 = 45" '" 44' " 43

    42

    ~\\.\" "\

  • 8/3/2019 Prescolite Emergency Systems ES-4 1992

    49/60

    PR-232DIAGNOSTIC INTERFACE OPTIO

    The PR-232 connects directly to a localcomputer or via modem to any remotecomputer.The PR-232 has an on board rnicrocorn-puter which monitors vital status pointswithin the power system. Important statusinformation of the power system is sent toyour host computer via industry standardRS-232 port connection. Remote auto-matic system battery discharge may beperformed with regular full status reportssent to the host computer every 15 sec-onds; in the event the alarm condition isdetected, the discharge routine is auto-matically terminated. An audible warningin the PR-232 annunciates a fault condi-tion. A ll alarm limits are software adjust-able. Up to s ix branch circuits can bemonitored when using the PR-232 withan Emergency Lighting unit.

    Self DiagnosticsTo receive a system that is more comprehensive than the competition, order the following options:1. VTO . Variable time delay.2. CFA - Charger failure alarm.3. EWA Early warning alarm.4. HTA - High temperature alarm.5. OMP . Digital meter panel.6. ELD . Electrolyte level detector.7. OTA Output trip alarm (use only if output breakers are requested).

    Prescolite Emergency Systems

  • 8/3/2019 Prescolite Emergency Systems ES-4 1992

    50/60

    AC INVERTERSSTANDARD OPTIONS

    BATTERY OPTIONSELD Battery, electrolyte level detector and alarm-audible and visual Indication - AC sense current to prevent deterioration.(Applicable to vented batteries only. Not available on sealed batteries,)

    Same as above ELD except with flashing light.Low or high battery voltage alarm and/or alarm failure.Same as above except with flashing light.Fast recharge to reduce charging time.Early warning alarm sounds and closes a contact for remote use when the battery isapproaching end of charge during aprolonged uti lity power failure.Battery discharge alarm-beeping audible alarm dur ing discharge.Battery exerciser to simulate power fail ure for 10 minutes every 30 days.Specific gravity-hydrometer and thermometer available for vented battery servicing. (Applicable to wetbatteries only.)

    ELD-FLCFACFA-FLFCHEWABOABEXHYK

    OPTIONS AVAILABLE ON CABINETAMP Remote meter panel. Two lamp indicators, two meters (AC output volts and DC battery volts).DMP Digital meter panel, 3 ' 1 2 digit LCD display. Switch selectable, shows: Input volts, battery current , battery vol ts. outputfrequency, output AMPS, output valls.lAM AC input ammeter measures AC input current 10 system. Remote operation up to 50 feet away.IVM AC input VOltmeter-measures AC input voltage to system.FM AC input and/or AC output require frequency meter - specify which or both.DCA DC ammeter-measures battery output DC currenL Remote operation up 10 50 feet away.LCM AC output ammeter-measures output current of system.DL Lighted indicator 10 show battery charger status oj float charge.KSW Key switch-system on/off.PFM Power flow front panel monitor panel wilh up to 30 moving LED display lights. Shows operating status andpower How of system.INPUT OR OUTPUT OPTIONSICB Input circuit breaker for AC protection or service disconnect. Priced tor voltage, current rating and numberof poles. Mounted inside cabinet.

    Output Circuit breaker for load protection. Priced lor voltage. current rating and number of poles,isolation transformer required when line-to-line voltage on multi-phase inputs are different than theoutput vollage,Auto transformer required when Tnput voltage to neutral if different than the output voltage to neutral.Used lor balancing single-phase lighting loads on a three-phase distribution service during the normal operating mode.In the emergency mode all loads receive normal voltage from a single-phase source.Used for powering dual voltage loads In both normal and emergency operation,

    OCBISOAUTOMPH-3

    MPH-2ELECTRONIC OPTIONSOTAOMAHTAADA

    Output fuse and/or breaker alarm with audible indicator. Order one "OTA" per "OCB" (per pole).Audible and visual indication of system failure.Audible and visual indication of high temperature in electronic cabinet.Dual channel diagnostic monitor of system operation, n a problem occurs, wil l automatical ly dial up to 10 numbers perchannel and announce the alarm problem verbally to person who answers the phone. Requires "EWA" alarm option.Automatic transfer swi tch provides unattended switching from a primary input power source (ut ili ty) to a secondarypower source (Ae generator) after the primary source fails or goes below specified minimums.Variable time delay, delays transfer back to utility after a power failure.Emergency power off, provisions on U'le system to remotely shutdown the UPS during anemergency condition.Provides locall remote system diagnostics via an on board microprocessor. External computer or terminal required forlocal connect.

    ATSVTDEPOPR-232

    STARTUP SERVICE: Provide personnel for startup and/or "turn on".

    48 Prescolite Emergency Systems

  • 8/3/2019 Prescolite Emergency Systems ES-4 1992

    51/60

  • 8/3/2019 Prescolite Emergency Systems ES-4 1992

    52/60

    REMOTE LAMPS

    Prescolite Emergency Systems

    EL Hlrqectlon molded thermoplasticlamphead. Standard lamphead formost commercial Emergency f ix-tures (EDS, ELB, ESB,ERG, ERT,EG and EST series). Standard finishis whi te. Also available in black.

    ESHRugged steel' housing. Diecastaluminum swivel. Standard lamp-head for use on the ET series.Standard finish is bronze. Alsoavailable in chrome,black andwhile.

    EDHHigh impact injection moldedlamphead has factory sealed lampcontacts, threaded sealed nippleand' gasketed diecast mounting plateFor use with EDP series. Available inblack only.

    EMGSmall and stylish, this inJectionmolded miniature cylinder usesPAR-18 halogen lamps. Use inconjuction with the ELB, ESB, ERG,ERT and EST series. Standard'lin-ish i,swhite. Also available in black.

    TO ORDER:When ordering for use as a remotehead, order the catalog numberlisted above as a separate lineitem. Example: ELH-N0607W

    Catalog Lamp Lamp Lamp LampNumber Voltage Wattage Type Shape, ELH-N0607W 6 7.2 Incandescent T-5ELH-N0609W 6 9.0 Incandescent T-5ELH-N1209W 12 9.0 Incandescent T-5ELH-N0607 6 7.2 Incandescent PAR-36I::LH-N0612 6 12.0 Incandescent PAR-36ELH-N0625 6 25.0 Incandescent PAR-36ELH-NI212 12 12.0 Incandescent PAR-36ELH.-Nt225 12 25.0 Incandescent PAR-36ELH-H0606 6 6.0 Halogen PAR-36ELH-H0608 6 8.0 Halogen PAR-36ELH-H0612 6 12.0 Halogen PAR-36ELH-HI208 12 8.0 Halogen PAR-36ELH-H1212 t2 12.0 Halogen PAR-36ESH-N0607 6 7.2 Incandescent PAR-36ESH-N0612 6 12.0 Incandescent PAR-36ESH-N0625 6 25.0 Incandescent PAR-36ESH-N1212 12 12.0 Incandescent PAR36ESH-N1225 12 25.0 Incandescent PAR-36ESH-H0606 6 6.0 Halogen PAR-36ESH-H0608 6 8.0 Halogen PAR-36ESH-H0612 6 12.0 Halogen PAR"36ESH~H1208 12 8.0 Halogen PAR"36ESH-HI212 12 1.2.0 Halogen PAR-36EDH~N0607 6 7.2 Incandescent PAR-36EDH-N0612 6 12.0 Incandescent PAR"36EDH-N0625 6 25.0 Incandescent PAR-36EDH~N1212 12 12.0 Incandescent PAR-36IEDH-N1225 12 25.0 Incandescent PAR-36EDH~H0606 6 6,0 Halog.en PAR-36EDH-H0608 6 8.0 Halogen PAR-36 .EDH-H0612 6 12.0 Halogen PAR-36EDH~H1208 12 8.0 Hatogen PAR-36EDH-HI212 12 12.0 Halogen PAR-36EMC~H0607P18 6 7.0 Halogen PAR-18EMC-H0612P18 6 12.0 Halogen PAR-18EMC-H 1212P18 12 12.0 Halogen PAR-18

    When subst ituting standard lampheads of emergency fixtures. suff ix theemergency unit with the desired remote lamp catalog number.Example: ET8 ESH - N1225emergency . : : : : : r - L remote lampunit to be usedon emergency unit

    Contact factory tor availability ottwo remote lampheadson a singlemounting plate.To order. add U to catalog number (Example: ESHD-N0607)

  • 8/3/2019 Prescolite Emergency Systems ES-4 1992

    53/60

    REMOTE FIXTURES

    SquareInjection molded housing. S