Top Banner
Preliminary Studies of PMTs of Modules in Emergency Mode Using the Laser System 30/04/2013 CERN-Oujda 1
14

Preliminary Studies of PMTs of Modules in Emergency Mode Using the Laser System

Feb 23, 2016

Download

Documents

Sanne

Preliminary Studies of PMTs of Modules in Emergency Mode Using the Laser System. 30/04/2013 CERN-Oujda. Outline. General Description Motivation LB Modules in Emergency Mode EB modules in Emergency Mode Conclusion. General Description. Mecanical Structure of Atlas Tile Module : - PowerPoint PPT Presentation
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Preliminary Studies  of  PMTs  of  Modules in Emergency Mode  Using  the Laser System

1

Preliminary Studies of PMTs of Modules in Emergency Mode Using the Laser System

30/04/2013CERN-Oujda

Page 2: Preliminary Studies  of  PMTs  of  Modules in Emergency Mode  Using  the Laser System

2

Outline• General Description• Motivation• LB Modules in Emergency Mode• EB modules in Emergency Mode• Conclusion

Page 3: Preliminary Studies  of  PMTs  of  Modules in Emergency Mode  Using  the Laser System

3

Tile

PMT Fibre WLS

ZRHadrons and Muons (LASER for calibration)

General Description

Doublelecture Module

(64 Modules/Barrel)

3 Barrels

Central

Étendu A

Étendu C

LBEBA

EBC

< 1.7

R ~10 mL ~13 m2500 t

64 modules4~460000 tiles, ~640000 fibers and ~10000 PMTs

Mecanical Structure of Atlas Tile Module :• Sampling calorimeter: iron + Scintillating tiles• Signal transported by Wave Length Shifter optical fibers from

scintillating tiles to the PMT's.

Page 4: Preliminary Studies  of  PMTs  of  Modules in Emergency Mode  Using  the Laser System

4

Motivation• 3 TileCal modules are in EM in

2012;• We don’t know wether the

PMTs in the EM are linear;• Laser light can be used for

such a study; The idea is to compare the

responses of PMTs in EM and of PMTs in normal mode.

• Different runs containing different filters wheel are used, allowing to apply a specific attenuation factor from 3 to 1000 to the laser beam.

• NB: the runs we are using have been taken in period when only 2 modules are in EM.

| attenuation | filter wheel | run number| ----------------------------- | 1 | 5 | 208762 |- | 3 | 6 | 208758 | | 10 | 4 | 208767 | | 32 | 3 | 208770 | | 100 | 2 | 208772 | | 320 | 8 | 208755 | | 1000 | 7 | 208756 | -----------------------------------------------------

Page 5: Preliminary Studies  of  PMTs  of  Modules in Emergency Mode  Using  the Laser System

5

1. LB Module in EMPMTr: PMT belong to Module in normal modePMT (EM): PMT belong to Module in Emergency Mode

1. In this case we will use the property that one fiber can belong to PMTr and to PMT (EM) simultaneously.

Page 6: Preliminary Studies  of  PMTs  of  Modules in Emergency Mode  Using  the Laser System

6

LB: PMT response of Module in Normal Mode Using Filters Attenuations

Page 7: Preliminary Studies  of  PMTs  of  Modules in Emergency Mode  Using  the Laser System

7

LB: PMT response of Module in EM Using Filter Attenuation

Page 8: Preliminary Studies  of  PMTs  of  Modules in Emergency Mode  Using  the Laser System

8

LB: Module in EM

• The mean energy of PMTs (EM) as function of mean eneregy of PMTr for :

• Module 28: -> LBA, PMTr 27

-> LBC, PMT(EM1)26Filter X error Y error X fit value Y fit Value (Yfit-Ymes)/Ymes1 0.034591 0.017935 268.621331 140.210787 0.000315

2 0.008759 0.004701 63.679009 33.137730 -0.002708

3 0.003490 0.001626 21.052682 10.936442 -0.004447

4 0.001416 0.000704 6.760521 3.562413 0.004447

5 0.000368 0.000185 0.656977 0.348858 0.017641

6 0.074510 0.039017 19.367437 10.0774555 -0.003104

Page 9: Preliminary Studies  of  PMTs  of  Modules in Emergency Mode  Using  the Laser System

9

LB: Module in EM

• For comparaison we show also the plots obtained using two PMTs fed by the same fiber both belonging to module in normal mode

• Module 12: -> LBA PMTr 14

-> LBC PMT 15

The latest point on the right is out of the linear shape; for high signal the PMT’s are saturating.

Page 10: Preliminary Studies  of  PMTs  of  Modules in Emergency Mode  Using  the Laser System

10

2. EB: PMTs Responses

In the Extended barrel case, each module is fed by one fiber,• -> since PMT(EM) and PMTr cannot belonging to the same fiber , We use to study

the linearity of PMT(EM) a PMTr of an arbitrary module in a given partition..

Page 11: Preliminary Studies  of  PMTs  of  Modules in Emergency Mode  Using  the Laser System

11

2. EB :PMT response of Module in normal mode

Page 12: Preliminary Studies  of  PMTs  of  Modules in Emergency Mode  Using  the Laser System

12

2. EB :PMT response of Module in EM

Page 13: Preliminary Studies  of  PMTs  of  Modules in Emergency Mode  Using  the Laser System

13

EB: Module in EM• Module 17 : ->EBA,PMTr12• Module01 : ->EBC,

PMT(EM)15

• Module 07 : ->EBA, PMTr 12• Module 02 : ->EBC PMT 15.

Page 14: Preliminary Studies  of  PMTs  of  Modules in Emergency Mode  Using  the Laser System

14

Conclusion• PMTs(26,27) responses at LB module 28 have

maximal variation ~1.7%