Top Banner
Preliminary Results of Magnetic Field Analysis for Specific Items in Step IV Control Racks Behind Nth Shield Wall modelled with Aluminium or Steel frame Mike Courthold 2 nd October 2012
11

Preliminary Results of Magnetic Field Analysis for Specific Items in Step IV

Feb 24, 2016

Download

Documents

whitby

Preliminary Results of Magnetic Field Analysis for Specific Items in Step IV. Control Racks Behind Nth Shield Wall modelled with Aluminium or Steel frame. Mike Courthold 2 nd October 2012. - PowerPoint PPT Presentation
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Preliminary Results of Magnetic Field Analysis for Specific Items in Step IV

Preliminary Results of Magnetic Field Analysis for Specific Items in Step IV

Control Racks Behind Nth Shield Wallmodelled with

Aluminium or Steel frame

Mike Courthold2nd October 2012

Page 2: Preliminary Results of Magnetic Field Analysis for Specific Items in Step IV

Steel racks behind Nth Wall – Field strength on far side of Nth Wall is 0.4T, thus 621G max on rack sides

Page 3: Preliminary Results of Magnetic Field Analysis for Specific Items in Step IV

Steel racks behind Nth Wall – Field strength on far side of Nth Wall is 0.4T, hence effect on rack sides

Page 4: Preliminary Results of Magnetic Field Analysis for Specific Items in Step IV

Steel racks behind Nth Wall – 18G max inside

Page 5: Preliminary Results of Magnetic Field Analysis for Specific Items in Step IV

Steel racks behind Nth Wall – 18G max inside

Page 6: Preliminary Results of Magnetic Field Analysis for Specific Items in Step IV

Steel racks behind Nth Wall – 18G max inside

Page 7: Preliminary Results of Magnetic Field Analysis for Specific Items in Step IV

Aluminium racks behind Nth Wall – Field strength on far side of Nth Wall still 0.4T, but only 5G max on rack sides

Page 8: Preliminary Results of Magnetic Field Analysis for Specific Items in Step IV

Aluminium racks behind Nth Wall – Field strength on far side of Nth Wall is still 0.4T, but now negligible effect on frame

Page 9: Preliminary Results of Magnetic Field Analysis for Specific Items in Step IV

Aluminium racks behind Nth WallField now increased from 18G to 38G max inside

Page 10: Preliminary Results of Magnetic Field Analysis for Specific Items in Step IV

Aluminium racks behind Nth WallField now increased from 18G to 38G max inside

Page 11: Preliminary Results of Magnetic Field Analysis for Specific Items in Step IV

Conclusion

• Changing rack frames from steel to aluminium dramatically reduces the field experienced by the rack frame from 621G to 5G

• But the field experienced by ferrous objects inside the rack has increased, according to this crude model, from 18G to 38G

• The model is as yet to crude to indicate whether the choice of aluminium framed racks would be beneficial, as no attempt has been made to accurately distribute the mass within