GSPublisherEngine 1468.15.18.100 ALL DIMENSIONS SHOWN ON DRAWINGS ,COUNCIL (PUBLIC) DRAIN POSITIONS AND INVERTS SHALL BE CONFIRMED BY CONTRACTOR PRIOR TO ANY WORKS COMMENCING. NOTIFY URBAN DESIGN NZ LTD SHOULD DIMENSIONS OR POSITIONS VARY TO THAT SHOWN IMMEDIATELY . IF GROUND CONDITIONS ARE QUESTIONABLE AND ARE NOT IN ACCORDANCE WITH NZBC OR NZS 3604:2011REQUIREMENTS STOP WORK AND CONTACT DESIGNER IMMEDIATELY . SHOULD THERE BE ANY AMBIGUITY ON THE DRAWINGS AND/OR ACCOMPANYING DOCUMENTATION, OR THE MEANING(S) IS(ARE) UNCLEAR OR IF THERE IS APPARENT CONFLICTING INFORMATION SHOWN, IMMEDIATELY NOTIFY URBAN DESIGN NZ LTD BEFORE COMMENCING THE WORK. NOTES: Z:\Urban Design NZ LTD\Urban Design Plans\ARCHICAD V18\423 - WSP - 466 Hagley Ave\Drawing Files\V18.422 - WSP - 466 Hagley Ave - RC9 - 20180628.pln ROOF TRUSS AND BRACING IS INDICATIVE ONLY AND SHALL BE DESIGNED AND DETAILED BY APPROVED GANGNAIL TRUSS MANUFACTURER IN ACCORDANCE WITH GANG-NAIL NZ LIMITED NZ500 AND NZS 3604 : 2011 FOR WIND BRACING AND TYPE REFER TO ADJOINING SPECS LINTELS TO BE 24% MAX MOISTURE CONTENT .TIMBER SIZES AS PER NZS 3604 : 2011 KITCHEN JOINERY MANUFACTURER SHALL TAKE ' ON SITE ' MEASUREMENTS PRIOR TO FABRICATION. FOR KITCHEN LAYOUT AND JOINERY REFER TO KITCHEN MANUFACTURERS DOCUMENTS. ALL GLASS TO BE AS PER NZS 4223 (PART 3 IN PARTICULAR) ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE NZBC HAND BOOK AND APPROVED DOCUMENTS ,NZS 3604 : 2011 AND LOCAL TERRITORIAL AUTHORITY REQUIREMENTS. WINDOW MANUFACTURERS SHALL CHECK ' ON SITE ' ALL WINDOW OPENING SIZES PRIOR TO FABRICATION. ALL PLUMBING AND DRAINAGE WORK SHALL BE IN ACCORDANCE WITH NZBC REQUIREMENTS AND APPROVED DOCUMENTS. VENTILATION TO FOUNDATION WALLS TO COMPLY TO NZS 3604 SECTION 4.8. Preliminary - Not for Construction Purposes TITLE: Site Plan Client: Address: Williams Corporation 466-468 Hagley Ave Christchurch Central Christchurch Scale: Drawn By: As Shown @ A1 Start Date: Print Date: 27-Apr-18 28-Jun-18 Revision RC CC Sheet 2 Revision Notes: This Drawing remains the property of Urban Design Ltd. It must not be used, copied or handed to any third party without the written permission of Urban Design Ltd. The Contractor shall check and verify all dimensions and levels prior to commencing any work. All construction shall be in accordance with NZS 3604, unless specifically Engineered, and in accordance with the current Building Act. ALL PROPOSED SED CONCRETE WORK TO BE 25 MPa Architectural Designers & Project Management Services 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 N 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 4,360 26,815 4,030 18,810 1,700 2,350 19,218 5,158 10,910 4,050 +16,700 10.65 m 2 8.43 m 2 8.45 m 2 10.65 m 2 8.45 m 2 8.43 m 2 20.61 m 2 20.54 m 2 20.61 m 2 20.54 m 2 68.23 m 2 39.74 m 2 80.95 m 2 25.45 m 2 HRB - J 2.3m @ 54° HRB - A 2.3m @ 60.3° HRB - B 2.3m @ 60.3° HRB - B 2.3m @ 60.3° HRB - C 2.3m @ 65° HRB - D 2.3m @ 65° HRB - E 2.3m @ 65° HRB - F 2.3m @ 50° HRB - G 2.3m @ 50° HRB - H 2.3m @ 50° HRB - I 2.3m @ 50° HRB - K 2.3m @ 54° timber covers to heat pump units NOTE: - all paths to be well lit - LED light to front doors of each unit to light path. - Lights to be on a timer (daylight sensor) for security. F5/AS1 NOTE: contractor to safeguard people from injury, and other property from damage, caused by construction or demolition site hazards, as per F5/AS1. Construction and demolition work on buildings shall be performed in a manner that avoids the likelihood of: (a) objects falling onto people on or off the site, (b) objects falling on property off the site, (c) other hazards arising on the site affecting people off the site and other property, and (d) unauthorised entry of children to hazards on the site. NOTE: - refer to landscaping plan for all planting, fencing, surfaces and site structiures 269°48'30" 205°13'30" 320°39'40" 50°39'40" 50°39'40" 140 ° 39 ' 40 " 89°48'30" 179°48'40" 205°13'30" 320°39'40" 31.12 16.71 37.25 15.09 20.12 20 . 51 21.57 20.12 22.27 30.07 + 16,35 +16,29 +16,22 + 16,18 + 16,12 + 16,07 +16,34 + 16,33 +16,41 +16,16 +16,18 +16,31 +16.09 +16.13 + 16,31 + 16,23 + 16,13 + 16,16 +16,33 +15,94 + 16,02 +16,15 +16,11 +16,09 +15,94 line of deck above line of deck above line of deck above Hagley Block Selwyn Block NOTE: - AC units to have trellis covers. hp hp hp hp hp hp hp hp hp hp 8.65 m 2 8.60 m 2 8.65 m 2 8.60 m 2 8.64 m 2 8.65 m 2 W W W W W W W W W W M N O P Q R S A C B D E F M N O P Q G Bins Bike parks with power points M N O P Q A C D G E B F N - Proposed Site Plan 1:100 1:100 - Location Plan
12

Preliminary - Not for Construction Purposes€¦ · Preliminary - Not for Construction Purposes TITLE: Site Plan Client: Address: Williams Corporation 466-468 Hagley Ave Christchurch

Jun 16, 2020

Download

Documents

dariahiddleston
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Preliminary - Not for Construction Purposes€¦ · Preliminary - Not for Construction Purposes TITLE: Site Plan Client: Address: Williams Corporation 466-468 Hagley Ave Christchurch

GSPublisherEngine 1468.15.18.100

ALL DIMENSIONS SHOWN ON DRAWINGS ,COUNCIL (PUBLIC) DRAIN

POSITIONS AND INVERTS SHALL BE CONFIRMED BY CONTRACTOR

PRIOR TO ANY WORKS COMMENCING. NOTIFY URBAN DESIGN NZ

LTD SHOULD DIMENSIONS OR POSITIONS VARY TO THAT SHOWN

IMMEDIATELY.

IF GROUND CONDITIONS ARE QUESTIONABLE AND ARE NOT IN

ACCORDANCE WITH NZBC OR NZS 3604:2011REQUIREMENTS

STOP WORK AND CONTACT DESIGNER IMMEDIATELY.

SHOULD THERE BE ANY AMBIGUITY ON THE DRAWINGS AND/OR

ACCOMPANYING DOCUMENTATION, OR THE MEANING(S) IS(ARE)

UNCLEAR OR IF THERE IS APPARENT CONFLICTING INFORMATION

SHOWN, IMMEDIATELY NOTIFY URBAN DESIGN NZ LTD BEFORE

COMMENCING THE WORK.

NOTES:

Z:\Urban Design NZ LTD\Urban Design Plans\ARCHICAD V18\423 - WSP - 466 Hagley Ave\Drawing Files\V18.422 - WSP - 466 Hagley Ave - RC9 - 20180628.pln

ROOF TRUSS AND BRACING IS INDICATIVE ONLY AND SHALL BE

DESIGNED AND DETAILED BY APPROVED GANGNAIL TRUSS

MANUFACTURER IN ACCORDANCE WITH GANG-NAIL NZ LIMITED

NZ500 AND NZS 3604 : 2011

FOR WIND BRACING AND TYPE REFER TO ADJOINING SPECS

LINTELS TO BE 24% MAX MOISTURE CONTENT .TIMBER SIZES AS PER

NZS 3604 : 2011

KITCHEN JOINERY MANUFACTURER SHALL TAKE ' ON SITE '

MEASUREMENTS PRIOR TO FABRICATION.

FOR KITCHEN LAYOUT AND JOINERY REFER TO KITCHEN

MANUFACTURERS DOCUMENTS.

ALL GLASS TO BE AS PER NZS 4223 (PART 3 IN PARTICULAR)

ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE NZBC

HAND BOOK AND APPROVED DOCUMENTS ,NZS 3604 : 2011 AND

LOCAL TERRITORIAL AUTHORITY REQUIREMENTS.

WINDOW MANUFACTURERS SHALL CHECK ' ON SITE ' ALL WINDOW

OPENING SIZES PRIOR TO FABRICATION.

ALL PLUMBING AND DRAINAGE WORK SHALL BE IN ACCORDANCE

WITH NZBC REQUIREMENTS AND APPROVED DOCUMENTS.

VENTILATION TO FOUNDATION WALLS TO COMPLY TO NZS 3604

SECTION 4.8.

Preliminary - Notfor Construction

Purposes

TITLE: Site Plan

Client:

Address:

Williams Corporation

466-468 Hagley Ave

Christchurch Central

Christchurch

Scale:

Drawn By:

As Shown @ A1

Start Date:

Print Date:

27-Apr-18

28-Jun-18

Revision RC

CC

Sheet

2

Revision Notes:

This Drawing remains the property of Urban Design Ltd. It

must not be used, copied or handed to any third party without

the written permission of Urban Design Ltd.

The Contractor shall check and verify all dimensions and

levels prior to commencing any work.

All construction shall be in accordance with NZS 3604, unless

specifically Engineered, and in accordance with the current

Building Act.

ALL PROPOSED SED CONCRETE WORK TO BE 25 MPa

Architectural Designers & Project Management Services123456789

10

11

12

13

14

15

16

17

18

N

1 2 3 4 5 6 7 8 9 10

11

12

13

14

15

16

17

18

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

4,360 26,815 4,030

18,8

10

1,7

00

2,350

19,218

5,15

8

10,9

10

4,05

0

+16,700

10.65 m2 8.43 m28.45 m210.65 m28.45 m28.43 m2

20.61 m2

20.54 m2

20.61 m2

20.54 m2

68.23 m2

39.74 m2

80.95 m2

25.45 m2

HRB - J

2.3m @ 54°

HRB - A

2.3m @ 60.3°

HRB - B

2.3m @ 60.3°

HRB - B

2.3m @ 60.3°

HRB - C

2.3m @ 65°

HRB - D

2.3m @ 65°

HRB - E

2.3m @ 65°

HRB - F

2.3m @ 50°

HRB - G

2.3m @ 50°

HRB - H

2.3m @ 50°

HRB - I

2.3m @ 50°

HRB - K

2.3m @ 54°

timber covers to heat pump units

NOTE:

- all paths to be well lit

- LED light to front doors of each unit to light path.

- Lights to be on a timer (daylight sensor) for security.

F5/AS1 NOTE:

contractor to safeguard people from injury, and other

property from damage, caused by construction or demolition

site hazards, as per F5/AS1.

Construction and demolition work on buildings shall be

performed in a manner that avoids the likelihood of:

(a) objects falling onto people on or off the site,

(b) objects falling on property off the site,

(c) other hazards arising on the site affecting people off the

site and other property, and

(d) unauthorised entry of children to hazards on the site.

NOTE:

- refer to landscaping plan for all planting,

fencing, surfaces and site structiures

269°48'30"

205°13'30"

32

0°3

9'4

0"

50°39'40" 50°39'40"

14

0°3

9'4

0"

89°48'30"179°48'40"

205°13'30"

32

0°3

9'4

0"

31.12

16.71

37

.25

15.09 20.12

20

.51

21.57

20.12

22.27

30

.07

+

16,35

+16,29

+16,22

+

16,18

+

16,12

+

16,07

+16,34

+

16,33

+16,41

+16,16

+16,18

+16,31

+16.09

+16.13

+

16,31

+

16,23

+

16,13

+

16,16

+16,33

+15,94

+

16,02

+16,15

+16,11

+16,09

+15,94

line

of d

eck

abov

e

line

of d

eck

abov

e

line of deck

above

Hagley

Block

Selwyn

Block

NOTE:

- AC units to have trellis covers.

hp

hp

hp

hp

hp

hp

hp hp hp

hp

8.65 m2

8.60 m2

8.65 m2

8.60 m2

8.64 m2 8.65 m2

W W W W

W

W

W

W

W

W

M N O P Q R S

A

C

B

D

E

F

M N O P Q

G

Bins

Bike parkswith power

points

M

N

O

P

Q

A

C

D

G

E

B

F

N

-

Proposed Site Plan 1:100 1:100

-

Location Plan

Page 2: Preliminary - Not for Construction Purposes€¦ · Preliminary - Not for Construction Purposes TITLE: Site Plan Client: Address: Williams Corporation 466-468 Hagley Ave Christchurch

GSPublisherEngine 1468.15.18.100

Architectural Designers & Project Management Services

Revision Notes: TITLE: Hagley Block - Ground Floor Plan

Client:

Address:

Williams Corporation

466-468 Hagley Ave

Christchurch Central

Christchurch

Scale:

Drawn By:

As Shown @ A1

Start Date:

Print Date:

27-Apr-18

28-Jun-18

SheetRevision RC8

3CC

ALL DIMENSIONS SHOWN ON DRAWINGS ,COUNCIL (PUBLIC) DRAIN

POSITIONS AND INVERTS SHALL BE CONFIRMED BY CONTRACTOR PRIOR

TO ANY WORKS COMMENCING. NOTIFY URBAN DESIGN NZ LTD SHOULD

DIMENSIONS OR POSITIONS VARY TO THAT SHOWN IMMEDIATELY.

IF GROUND CONDITIONS ARE QUESTIONABLE AND ARE NOT IN

ACCORDANCE WITH NZBC OR NZS 3604:2011REQUIREMENTS STOP

WORK AND CONTACT DESIGNER IMMEDIATELY.

NOTES:

ROOF TRUSS AND BRACING IS INDICATIVE ONLY AND SHALL BE

DESIGNED AND DETAILED BY APPROVED GANGNAIL TRUSS

MANUFACTURER IN ACCORDANCE WITH GANG-NAIL NZ LIMITED

NZ500 AND NZS 3604 : 2011

FOR WIND BRACING AND TYPE REFER TO ADJOINING SPECS

LINTELS TO BE 24% MAX MOISTURE CONTENT .TIMBER SIZES AS

PER NZS 3604 : 2011

KITCHEN JOINERY MANUFACTURER SHALL TAKE ' ON SITE '

MEASUREMENTS PRIOR TO FABRICATION.

FOR KITCHEN LAYOUT AND JOINERY REFER TO KITCHEN

MANUFACTURERS DOCUMENTS.

ALL GLASS TO BE AS PER NZS 4223 (PART 3 IN PARTICULAR)

ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE NZBC HAND

BOOK AND APPROVED DOCUMENTS ,NZS 3604 : 2011 AND LOCAL

TERRITORIAL AUTHORITY REQUIREMENTS.

WINDOW MANUFACTURERS SHALL CHECK ' ON SITE ' ALL WINDOW

OPENING SIZES PRIOR TO FABRICATION.

ALL PLUMBING AND DRAINAGE WORK SHALL BE IN ACCORDANCE

WITH NZBC REQUIREMENTS AND APPROVED DOCUMENTS.

VENTILATION TO FOUNDATION WALLS TO COMPLY TO NZS 3604

SECTION 4.8.

SHOULD THERE BE ANY AMBIGUITY ON THE DRAWINGS AND/OR

ACCOMPANYING DOCUMENTATION, OR THE MEANING(S) IS(ARE)

UNCLEAR OR IF THERE IS APPARENT CONFLICTING INFORMATION

SHOWN, IMMEDIATELY NOTIFY URBAN DESIGN NZ LTD BEFORE

COMMENCING THE WORK.

Z:\Urban Design NZ LTD\Urban Design Plans\ARCHICAD V18\423 - WSP - 466 Hagley Ave\Drawing Files\V18.422 - WSP - 466 Hagley Ave - RC9 - 20180628.pln

This Drawing remains the property of Urban Design Ltd.

It must not be used, copied or handed to any third party

without the written permission of Urban Design Ltd

The Contractor shall check and verify all dimensions and

levels prior to commencing any work.

All construction shall be in accordance with NZS 3604,

unless specifically Engineered, and in accordance with

the current Building Act.

Preliminary - Not for Construction Purposes

ALL PROPOSED SED CONCRETE WORK TO BE 25 MPa

860x2,1

75

860x2,1

75

860x2,1

75

860x2,1

75

760x1,980

760x1,980

550x1,980

2/660x1,980 660x1,980

760x1,980

550x1,980

760x1,980

2/660x1,980 660x1,980

760x1,980

550x1,980

760x1,980

2/660x1,980 660x1,980

760x1,980

760x1,980

550x1,980

2/660x1,980660x1,980

760x1,980

760x1,980

2/660x1,9

80

760x1,980

550x1,980

2/660x1,980 660x1,980

860x2,175 860x2,175

760x1,980

760x1,980

2/660x1,9

80

760x1,980

550x1,980

2/660x1,980660x1,980

123456789

10

11

12

13

14

15

16

17

18

1 2 3 4 5 6 7 8 9 10

11

12

13

14

15

16

17

18

26,815

220 4,388 4,400 4,400 4,400 4,400 4,388 220

600 3,608 800 3,600 800 3,600 800 3,600 800 3,600 800 3,608 600

17,2

60

500

3,0

00

3,8

30

1,7

80

5,2

40

2,1

40

770

410

4,8

90

410

5,3

60

410

5,3

70

410

140

3,1

00

140

1,5

00

140

600

90

3,0

00

90

5,9

00

140

2,0

10

140

180

90

90

230

90

4,8

90

90

230

90

5,3

60

90

230

90

5,3

70

90

230

90

90 420 90 3,608 90 620 90 3,600 90 620 90 3,600 90 620 90 3,600 90 620 90 3,600 90 620 90 3,608 90 420 90

140 4,090 315 4,085 315 4,085 315 4,085 315 4,085 315 4,090 140 220

140 4,090 315 3,000 90 995 315 995 90 3,000 315 3,000 90 995 315 995 90 3,000 315 900 90 3,100 140 220

140

3,0

00

90

600

140

1,5

00

140

5,5

90

140

2,0

10

140

16,7

60

3,0

00

3,8

30

1,7

80

5,2

40

2,1

40

770

90

230

90

4,8

90

90

230

90

4,8

60

90

230

90

5,3

70

90

230

90

140

3,1

00

140

1,5

00

140

600

90

3,0

00

90

5,4

00

140

2,0

10

140

90

200

90

1,2

60

90

1,2

70

90

150

140

90

200

90

220 4,380 220 2,565 380 2,485 380 5,555 380 2,485 380 2,565 220 4,380 220

140 4,100 140 17,615 140 910 90 3,100 140

140 4,090 315 3,000 90 995 315 995 90 3,000 315 3,000 90 995 315 995 90 3,000 315 900 90 3,100 140

140 4,090 315 2,210 90 700 90 995 315 995 90 700 90 2,210 315 2,210 90 700 90 995 315 995 90 700 90 2,210 315 900 90 700 90 2,310 140

410

4,8

90

410

4,8

60

410

5,3

70

410

140

1,5

00

90

7,7

70

5,2

00

140

2,0

10

140

180

90

+16,700

A

13

A

13

45.40 m259.70 m243.39 m2 43.39 m2 45.40 m2

57.65 m2

timber covers to heat pump units

dining/lounge

bathroom

hwc &

store

bathroom bathroom bathroom

bathroom

dining/lounge

dining/lounge

dining/lounge

dining/lounge

kitchen kitchenkitchen kitchen

kitchen

built

in c

abin

et

built

in c

abin

et

built

in c

abin

et

built

in c

abin

et

wr wr wr wr

wr

bedroom bedroom bedroom bedroom

bedroom 2

bedroom 1

wr

entry

entry entry entry entry

entryhp hp hp hp

hp

hp hphp

hp hp

bathroom

wr

bedroom 2

bedroom 1

wr

dining/lounge

kitchen

hp

built

in c

abin

et

built

in c

abin

et

hp

hwc &

store

hwc &

store

hwc &

store

hwc &

store

hwc &

store

8.22 m28.22 m2

8.17 m2 8.17 m2

8.21 m2 8.22 m2

WF W F WF W F

WF

W F

D062,200 x 3,090

D042,200 x 3,090

D042,200 x 3,090

D042,200 x 3,090

D022,200 x 3,090

D032,200 x 3,090

D052,200 x 3,090

D052,200 x 3,090

D042,200 x 3,090

D042,200 x 3,090

D022,200 x 3,090

D022,200 x 3,090

M N O P Q R S

A

C

B

D

E

F

deckdeck

deckdeck

deckdeck

UNIT 1

UNIT 2UNIT 3UNIT 4UNIT 5UNIT 6

G

Deck Net

Area

Unit Area

Total

Net Area

Total

UNIT 1

UNIT 2

UNIT 3

UNIT 4

UNIT 5

UNIT 6

Total Over

Framing

hobrangeover

hobrangeover

hobrangeover

hobrangeover

hobrangeover

hobrangeover

10.50 57.65 68.15

8.21 45.40 53.61

10.50 59.70 70.20

72.98

75.17

8.17 43.39 51.56

8.17 43.39 51.56

8.21 45.40 53.61

59.66

57.76

57.76

59.66

-

Hagley Block - Ground Floor Plan 1:50

Page 3: Preliminary - Not for Construction Purposes€¦ · Preliminary - Not for Construction Purposes TITLE: Site Plan Client: Address: Williams Corporation 466-468 Hagley Ave Christchurch

GSPublisherEngine 1468.15.18.100

Architectural Designers & Project Management Services

Revision Notes: TITLE: Hagley Block - First Floor Plan

Client:

Address:

Williams Corporation

466-468 Hagley Ave

Christchurch Central

Christchurch

Scale:

Drawn By:

As Shown @ A1

Start Date:

Print Date:

27-Apr-18

28-Jun-18

SheetRevision RC8

4CC

ALL DIMENSIONS SHOWN ON DRAWINGS ,COUNCIL (PUBLIC) DRAIN

POSITIONS AND INVERTS SHALL BE CONFIRMED BY CONTRACTOR PRIOR

TO ANY WORKS COMMENCING. NOTIFY URBAN DESIGN NZ LTD SHOULD

DIMENSIONS OR POSITIONS VARY TO THAT SHOWN IMMEDIATELY.

IF GROUND CONDITIONS ARE QUESTIONABLE AND ARE NOT IN

ACCORDANCE WITH NZBC OR NZS 3604:2011REQUIREMENTS STOP

WORK AND CONTACT DESIGNER IMMEDIATELY.

NOTES:

ROOF TRUSS AND BRACING IS INDICATIVE ONLY AND SHALL BE

DESIGNED AND DETAILED BY APPROVED GANGNAIL TRUSS

MANUFACTURER IN ACCORDANCE WITH GANG-NAIL NZ LIMITED

NZ500 AND NZS 3604 : 2011

FOR WIND BRACING AND TYPE REFER TO ADJOINING SPECS

LINTELS TO BE 24% MAX MOISTURE CONTENT .TIMBER SIZES AS

PER NZS 3604 : 2011

KITCHEN JOINERY MANUFACTURER SHALL TAKE ' ON SITE '

MEASUREMENTS PRIOR TO FABRICATION.

FOR KITCHEN LAYOUT AND JOINERY REFER TO KITCHEN

MANUFACTURERS DOCUMENTS.

ALL GLASS TO BE AS PER NZS 4223 (PART 3 IN PARTICULAR)

ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE NZBC HAND

BOOK AND APPROVED DOCUMENTS ,NZS 3604 : 2011 AND LOCAL

TERRITORIAL AUTHORITY REQUIREMENTS.

WINDOW MANUFACTURERS SHALL CHECK ' ON SITE ' ALL WINDOW

OPENING SIZES PRIOR TO FABRICATION.

ALL PLUMBING AND DRAINAGE WORK SHALL BE IN ACCORDANCE

WITH NZBC REQUIREMENTS AND APPROVED DOCUMENTS.

VENTILATION TO FOUNDATION WALLS TO COMPLY TO NZS 3604

SECTION 4.8.

SHOULD THERE BE ANY AMBIGUITY ON THE DRAWINGS AND/OR

ACCOMPANYING DOCUMENTATION, OR THE MEANING(S) IS(ARE)

UNCLEAR OR IF THERE IS APPARENT CONFLICTING INFORMATION

SHOWN, IMMEDIATELY NOTIFY URBAN DESIGN NZ LTD BEFORE

COMMENCING THE WORK.

Z:\Urban Design NZ LTD\Urban Design Plans\ARCHICAD V18\423 - WSP - 466 Hagley Ave\Drawing Files\V18.422 - WSP - 466 Hagley Ave - RC9 - 20180628.pln

This Drawing remains the property of Urban Design Ltd.

It must not be used, copied or handed to any third party

without the written permission of Urban Design Ltd

The Contractor shall check and verify all dimensions and

levels prior to commencing any work.

All construction shall be in accordance with NZS 3604,

unless specifically Engineered, and in accordance with

the current Building Act.

Preliminary - Not for Construction Purposes

ALL PROPOSED SED CONCRETE WORK TO BE 25 MPa

860x2,1

75

860x2,1

75

860x2,1

75

860x2,1

75

760x1,980

760x1,980

550x1,980

2/660x1,980 660x1,980

760x1,980

550x1,980

760x1,980

2/660x1,980 660x1,980

760x1,980

550x1,980

760x1,980

2/660x1,980 660x1,980

760x1,980

760x1,980

550x1,980

2/660x1,980660x1,980

760x1,980

760x1,980

2/660x1

,980

760x1,980

550x1,980

2/660x1,980 660x1,980

860x2,175 860x2,175

760x1,980

760x1,980

2/660x1

,980

760x1,980

550x1,980

2/660x1,980660x1,980

12345678

9

10

11

12

13

14

15

16

1 2 3 4 5 6 7 8

910

11

12

13

14

15

16

A

13

A

13

26,815

220 4,388 4,400 4,400 4,400 4,400 4,388 220

600 3,608 800 3,600 800 3,600 800 3,600 800 3,600 800 3,608 600

17,2

60

500

3,0

00

3,8

30

1,7

80

5,2

40

2,1

40

770

410

4,8

90

410

5,3

60

410

5,3

70

410

140

14,5

60

140

2,0

10

140

180

90

140

14,5

60

140

2,0

10

140

90

230

90

16,4

40

90

230

90

90 420 90 3,608 90 620 90 3,600 90 620 90 3,600 90 620 90 3,600 90 620 90 3,600 90 620 90 3,608 90 420 90

140 4,090 315 4,085 315 4,085 315 4,085 315 4,085 315 4,090 140 220

140 3,100 90 900 315 3,000 90 995 315 995 90 3,000 315 3,000 90 995 315 995 90 3,000 315 900 90 3,100 140 220

140

3,0

00

90

600

140

1,5

00

140

5,5

90

140

2,0

10

140

16,7

60

3,0

00

3,8

30

1,7

80

5,2

40

2,1

40

770

410

4,8

90

410

4,8

60

410

5,3

70

410

90

230

90

4,8

90

90

230

90

4,8

60

90

230

90

5,3

70

90

230

90

140

3,1

00

140

1,5

00

140

600

90

3,0

00

90

5,4

00

140

2,0

10

140

90

200

90

1,2

60

90

1,2

70

26,815

220 4,388 4,400 4,400 4,400 4,400 4,608

90

150

140

90

200

90

220 4,380 310 2,475 380 2,485 380 2,378 800 2,378 380 2,485 380 2,565 220 4,380 220

90130

140 4,100 140 17,615 140 910 90 3,100 140130

90

90130

140 3,100 90 900 315 3,000 90 995 315 995 90 3,000 315 3,000 90 995 315 995 90 3,000 315 900 90 3,100 140130

90

140 3,100 90 900 315 2,210 90 700 90 995 315 995 90 700 90 2,210 315 2,210 90 700 90 995 315 995 90 700 90 2,210 315 900 90 700 90 2,310 140

3,0

00

45.40 m2

59.70 m2

43.39 m2 43.39 m2 45.40 m2

57.65 m2

timber covers to heat pump units

dining/lounge

bathroom bathroom bathroom bathroom

bathroom

dining/lounge

dining/lounge

dining/lounge

dining/lounge

kitchen kitchenkitchen kitchenkitchen

built

in c

abin

et

built

in c

abin

et

built

in c

abin

et

built

in c

abin

et

wr wr wr wr

wr

bedroom bedroom bedroom bedroom

bedroom 2

bedroom 1

wr

walkwaywalkway

entry entry entry entry

entry

hp

hp

hp hp

hp

hp

hp hp hphp hp

bedroom 2

wr

bathroom

dining/lounge

wr

entry

hp

built

in c

abin

et

built

in c

abin

et

kitchen

hwc &

store

hwc &

store

hwc &

store

hwc &

store

hwc &

store

hwc &

store

8.21 m2

8.22 m2

8.17 m28.17 m2

8.21 m28.22 m2

WF W F WF W FW F

WF

D062,200 x 3,090

D042,200 x 3,090

D042,200 x 3,090

D042,200 x 3,090

D022,200 x 3,090

D032,200 x 3,090

3/610x2,1

75

D052,050 x 3,090

D052,050 x 3,090

D042,050 x 3,090

D042,050 x 3,090

D022,050 x 3,090

D022,050 x 3,090

3/610x2,1

75

2.28 m2

2.28 m2

M N O P Q R S

A

C

B

D

E

F

deckdeckdeckdeck

deckdeck

UNIT 7

UNIT 8UNIT 9UNIT 10UNIT 11

UNIT 12

UNIT 7

UNIT 8

UNIT 9

UNIT 10

UNIT 11

UNIT 12

deck

Gdeck

Deck NetArea

Unit AreaTotal

Net AreaTotal

Total OverFraming

hobrangeover

hobrangeover

hobrangeover

hobrangeover

hobrangeover

10.50 57.65 68.15

8.21 45.40 53.61

10.50 59.70 70.20

72.98

75.17

8.17 43.39 51.56

8.17 43.39 51.56

8.21 45.40 53.61

59.66

57.76

57.76

59.66

-

Hagley Block - First Floor Plan 1:50

Page 4: Preliminary - Not for Construction Purposes€¦ · Preliminary - Not for Construction Purposes TITLE: Site Plan Client: Address: Williams Corporation 466-468 Hagley Ave Christchurch

GSPublisherEngine 1468.15.18.100

Architectural Designers & Project Management Services

Revision Notes: TITLE: Hagley Block - Second Floor Plan

Client:

Address:

Williams Corporation

466-468 Hagley Ave

Christchurch Central

Christchurch

Scale:

Drawn By:

As Shown @ A1

Start Date:

Print Date:

27-Apr-18

28-Jun-18

SheetRevision RC8

5CC

ALL DIMENSIONS SHOWN ON DRAWINGS ,COUNCIL (PUBLIC) DRAIN

POSITIONS AND INVERTS SHALL BE CONFIRMED BY CONTRACTOR PRIOR

TO ANY WORKS COMMENCING. NOTIFY URBAN DESIGN NZ LTD SHOULD

DIMENSIONS OR POSITIONS VARY TO THAT SHOWN IMMEDIATELY.

IF GROUND CONDITIONS ARE QUESTIONABLE AND ARE NOT IN

ACCORDANCE WITH NZBC OR NZS 3604:2011REQUIREMENTS STOP

WORK AND CONTACT DESIGNER IMMEDIATELY.

NOTES:

ROOF TRUSS AND BRACING IS INDICATIVE ONLY AND SHALL BE

DESIGNED AND DETAILED BY APPROVED GANGNAIL TRUSS

MANUFACTURER IN ACCORDANCE WITH GANG-NAIL NZ LIMITED

NZ500 AND NZS 3604 : 2011

FOR WIND BRACING AND TYPE REFER TO ADJOINING SPECS

LINTELS TO BE 24% MAX MOISTURE CONTENT .TIMBER SIZES AS

PER NZS 3604 : 2011

KITCHEN JOINERY MANUFACTURER SHALL TAKE ' ON SITE '

MEASUREMENTS PRIOR TO FABRICATION.

FOR KITCHEN LAYOUT AND JOINERY REFER TO KITCHEN

MANUFACTURERS DOCUMENTS.

ALL GLASS TO BE AS PER NZS 4223 (PART 3 IN PARTICULAR)

ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE NZBC HAND

BOOK AND APPROVED DOCUMENTS ,NZS 3604 : 2011 AND LOCAL

TERRITORIAL AUTHORITY REQUIREMENTS.

WINDOW MANUFACTURERS SHALL CHECK ' ON SITE ' ALL WINDOW

OPENING SIZES PRIOR TO FABRICATION.

ALL PLUMBING AND DRAINAGE WORK SHALL BE IN ACCORDANCE

WITH NZBC REQUIREMENTS AND APPROVED DOCUMENTS.

VENTILATION TO FOUNDATION WALLS TO COMPLY TO NZS 3604

SECTION 4.8.

SHOULD THERE BE ANY AMBIGUITY ON THE DRAWINGS AND/OR

ACCOMPANYING DOCUMENTATION, OR THE MEANING(S) IS(ARE)

UNCLEAR OR IF THERE IS APPARENT CONFLICTING INFORMATION

SHOWN, IMMEDIATELY NOTIFY URBAN DESIGN NZ LTD BEFORE

COMMENCING THE WORK.

Z:\Urban Design NZ LTD\Urban Design Plans\ARCHICAD V18\423 - WSP - 466 Hagley Ave\Drawing Files\V18.422 - WSP - 466 Hagley Ave - RC9 - 20180628.pln

This Drawing remains the property of Urban Design Ltd.

It must not be used, copied or handed to any third party

without the written permission of Urban Design Ltd

The Contractor shall check and verify all dimensions and

levels prior to commencing any work.

All construction shall be in accordance with NZS 3604,

unless specifically Engineered, and in accordance with

the current Building Act.

Preliminary - Not for Construction Purposes

ALL PROPOSED SED CONCRETE WORK TO BE 25 MPa

860x2,1

75

860x2,1

75

860x2,1

75

860x2,1

75

760x1,980

760x1,980

550x1,980

2/660x1,980 660x1,980

760x1,980

550x1,980

760x1,980

2/660x1,980 660x1,980

760x1,980

550x1,980

760x1,980

2/660x1,980 660x1,980

760x1,980

760x1,980

550x1,980

2/660x1,980660x1,980

760x1,980

760x1,980

2/660x1,9

80

760x1,980

550x1,980

2/660x1,980 660x1,980

860x2,175 860x2,175

760x1,980

760x1,980

2/660x1

,980

760x1,980

550x1,980

2/660x1,980660x1,980

12345678

9

10

11

12

13

14

15

16

1 2 3 4 5 6 7 8

910

11

12

13

14

15

16

26,815

220 4,388 4,400 4,400 4,400 4,400 4,388 220

600 3,608 800 3,600 800 3,600 800 3,600 800 3,600 800 3,608 600

17,2

60

500

3,0

00

3,8

30

1,7

80

5,2

40

2,1

40

770

410

4,8

90

410

5,3

60

410

5,3

70

410

140

3,1

00

140

1,5

00

140

600

90

3,0

00

90

5,9

00

140

2,0

10

140

180

90

140

1,5

00

90

7,7

70

5,2

00

140

2,0

10

140

90

230

90

4,8

90

90

230

90

5,3

60

90

230

90

5,3

70

90

230

90

90 420 90 3,608 90 620 90 3,600 90 620 90 3,600 90 620 90 3,600 90 620 90 3,600 90 620 90 3,608 90 420 90

220 140 4,090 315 4,085 315 4,085 315 4,085 315 4,085 315 4,090 140 220

220 140 3,100 90 900 315 3,000 90 995 315 995 90 3,000 315 3,000 90 995 315 995 90 3,000 315 900 90 3,100 140 220

140

3,0

00

90

600

140

1,5

00

140

5,5

90

140

2,0

10

140

16,7

60

3,0

00

3,8

30

1,7

80

5,2

40

2,1

40

770

410

4,8

90

410

4,8

60

410

5,3

70

410

90

230

90

4,8

90

90

230

90

4,8

60

90

230

90

5,3

70

90

230

90

140

3,1

00

140

1,5

00

140

600

90

3,0

00

90

5,4

00

140

2,0

10

140

90

150

140

90

200

90

220 4,380 220 2,565 380 2,485 380 5,555 380 2,485 380 2,565 220 4,380 220

220 140 4,100 140 17,615 140 910 90 3,100 140

140 4,090 315 3,000 90 995 315 995 90 3,000 315 3,000 90 995 315 995 90 3,000 315 900 90 3,100 140

140 4,090 315 2,210 90 700 90 995 315 995 90 700 90 2,210 315 2,210 90 700 90 995 315 995 90 700 90 2,210 315 900 90 700 90 2,310 140100

1,0

00

3,0

00

1,600 2,760 1,550

1,0

00

100

1,0

00

3,0

00

1,550 2,760 1,600

140

1,5

00

90

1,5

10

140

1,5

00

140

600

90

3,0

00

90

700

4,7

00

140

2,0

10

140

45.40 m259.70 m2 43.39 m2 43.39 m2 45.40 m2 57.65 m2

timber covers to heat pump units

dining/lounge

bathroom bathroom bathroom bathroom

bathroom

dining/lounge

dining/lounge

dining/lounge

dining/lounge

kitchen kitchenkitchen kitchenkitchen

built

in c

abin

et

built

in c

abin

et

built

in c

abin

et

built

in c

abin

et

wr wr wr wr

wr

bedroom bedroom bedroom bedroom

bedroom 2

bedroom 1

walkwaywalkway

wr

entry entry entry entry

entry

hp

hp

hp hp

hp

hp

hp hp hphp hp

dining/lounge

bathroom

wr

kitchen

wr

entry

hp

built

in c

abin

et

built

in c

abin

et

hwc &

store

hwc &

store

hwc &

store

hwc &

store

hwc &

store

hwc &

store

bedroom 2

bedroom 1

8.22 m2 8.21 m2

8.17 m2 8.17 m2

8.21 m2 8.22 m2

WF W F WF W FF W

FW

D062,200 x 3,090

D042,200 x 3,090

D042,200 x 3,090

D042,200 x 3,090

D022,200 x 3,090

D032,200 x 3,090

3/610x2,1

75

D052,050 x 3,090

D052,050 x 3,090

D042,050 x 3,090

D042,050 x 3,090

D022,050 x 3,090

D022,050 x 3,090

3/610x2,1

75

2.28 m2

2.28 m2

M N O P Q R S

A

C

B

D

E

F

deckdeck

deckdeck

deckdeck

UNIT 13UNIT 14UNIT 15UNIT 16UNIT 17UNIT 18

deck

Deck NetArea

Unit AreaTotal

Net AreaTotal

10.50UNIT 13 57.65 68.15

8.21UNIT 14 45.40 53.61

UNIT 15

UNIT 16

UNIT 17

10.50UNIT 18 59.70 70.20

Total OverFraming

72.98

75.17

8.17 43.39 51.56

8.17 43.39 51.56

8.21 45.40 53.61

59.66

57.76

57.76

59.66

Gdeck

hobrangeover

hobrangeover

hobrangeover

hobrangeover

hobrangeover

-

Hagley Block - Second Floor Plan 1:50

Page 5: Preliminary - Not for Construction Purposes€¦ · Preliminary - Not for Construction Purposes TITLE: Site Plan Client: Address: Williams Corporation 466-468 Hagley Ave Christchurch

GSPublisherEngine 1468.15.18.100

Architectural Designers & Project Management Services

Revision Notes: TITLE: Selwyn Block - Ground Floor Plan

Client:

Address:

Williams Corporation

466-468 Hagley Ave

Christchurch Central

Christchurch

Scale:

Drawn By:

As Shown @ A1

Start Date:

Print Date:

27-Apr-18

28-Jun-18

SheetRevision RC8

6CC

ALL DIMENSIONS SHOWN ON DRAWINGS ,COUNCIL (PUBLIC) DRAIN

POSITIONS AND INVERTS SHALL BE CONFIRMED BY CONTRACTOR PRIOR

TO ANY WORKS COMMENCING. NOTIFY URBAN DESIGN NZ LTD SHOULD

DIMENSIONS OR POSITIONS VARY TO THAT SHOWN IMMEDIATELY.

IF GROUND CONDITIONS ARE QUESTIONABLE AND ARE NOT IN

ACCORDANCE WITH NZBC OR NZS 3604:2011REQUIREMENTS STOP

WORK AND CONTACT DESIGNER IMMEDIATELY.

NOTES:

ROOF TRUSS AND BRACING IS INDICATIVE ONLY AND SHALL BE

DESIGNED AND DETAILED BY APPROVED GANGNAIL TRUSS

MANUFACTURER IN ACCORDANCE WITH GANG-NAIL NZ LIMITED

NZ500 AND NZS 3604 : 2011

FOR WIND BRACING AND TYPE REFER TO ADJOINING SPECS

LINTELS TO BE 24% MAX MOISTURE CONTENT .TIMBER SIZES AS

PER NZS 3604 : 2011

KITCHEN JOINERY MANUFACTURER SHALL TAKE ' ON SITE '

MEASUREMENTS PRIOR TO FABRICATION.

FOR KITCHEN LAYOUT AND JOINERY REFER TO KITCHEN

MANUFACTURERS DOCUMENTS.

ALL GLASS TO BE AS PER NZS 4223 (PART 3 IN PARTICULAR)

ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE NZBC HAND

BOOK AND APPROVED DOCUMENTS ,NZS 3604 : 2011 AND LOCAL

TERRITORIAL AUTHORITY REQUIREMENTS.

WINDOW MANUFACTURERS SHALL CHECK ' ON SITE ' ALL WINDOW

OPENING SIZES PRIOR TO FABRICATION.

ALL PLUMBING AND DRAINAGE WORK SHALL BE IN ACCORDANCE

WITH NZBC REQUIREMENTS AND APPROVED DOCUMENTS.

VENTILATION TO FOUNDATION WALLS TO COMPLY TO NZS 3604

SECTION 4.8.

SHOULD THERE BE ANY AMBIGUITY ON THE DRAWINGS AND/OR

ACCOMPANYING DOCUMENTATION, OR THE MEANING(S) IS(ARE)

UNCLEAR OR IF THERE IS APPARENT CONFLICTING INFORMATION

SHOWN, IMMEDIATELY NOTIFY URBAN DESIGN NZ LTD BEFORE

COMMENCING THE WORK.

Z:\Urban Design NZ LTD\Urban Design Plans\ARCHICAD V18\423 - WSP - 466 Hagley Ave\Drawing Files\V18.422 - WSP - 466 Hagley Ave - RC9 - 20180628.pln

This Drawing remains the property of Urban Design Ltd.

It must not be used, copied or handed to any third party

without the written permission of Urban Design Ltd

The Contractor shall check and verify all dimensions and

levels prior to commencing any work.

All construction shall be in accordance with NZS 3604,

unless specifically Engineered, and in accordance with

the current Building Act.

Preliminary - Not for Construction Purposes

ALL PROPOSED SED CONCRETE WORK TO BE 25 MPa

51.48 m251.40 m2 51.50 m2 51.40 m2

123456789

10

11

12

13

14

15

16

17

18

270 5,123 5,140 5,140 5,123 270

140 4,825 315 4,825 315 4,825 315 4,825 140

1,5

00

2,0

00

3,8

30

1,0

90

4,5

50

1,4

40

270

11,4

50

1,5

00

2,0

00

3,8

30

1,7

80

3,8

60

1,4

40

270

410

2,8

20

410

4,3

10

410

2,6

80

410

21,065

670 20,395

650 4,343 800 4,378 725 4,378 800 4,343 650

140

3,0

00

140

1,5

00

140

4,4

10

140

1,3

00

140

11,4

50

410

2,8

20

410

4,3

10

410

2,6

80

410

270

140

3,0

00

140

1,5

00

140

4,4

10

140

1,3

00

140

270

270

140

3,0

00

140

1,5

00

140

620

70

3,7

20

140

1,3

00

140

270

270 5,123 5,140 5,140 5,123 270

135 515 3,080 410 6,030 725 6,030 410 3,080 380 270

140 1,095 70 590 70 3,000 315 1,095 70 590 70 3,000 315 3,000 70 590 70 1,095 315 3,000 70 590 70 1,095 140

270

10,9

10

270

140

3,0

00

140

1,5

00

140

620

70

3,7

20

140

1,3

00

140

270 140 4,825 315 4,825 315 4,825 315 4,825 140 270

270 140 4,135 90 600 315 1,755 70 3,000 315 3,000 70 1,755 315 600 90 4,135 140 270

270 140 1,095 90 3,640 315 1,095 90 3,640 315 3,640 90 1,095 315 3,640 90 1,095 140 270

+16,700 B

13

B

13

timber covers to heat pump units

dining / lounge

built

in c

abin

et

dining / lounge

bathroom

kitchen

bedroom

built

in c

abin

et

hp hp hphp

hphp

bathroom

bedroomwr

built

in c

abin

et

hp

bathroom

kitchen

bedroom

built

in c

abin

et

hp dining / lounge dining / lounge

hwc &

store

wr

hwc &

store

wr

hwc &

store

entry

entry entry

bathroom

kitchen

bedroom

wr

hwc &

store

entry

FWF W F W FW

UNIT 19UNIT 20

M N O P Q

A

C

D

G

E

B

UNIT 21UNIT 22

F

Deck NetArea

Unit AreaTotal

Net AreaTotal

6.29UNIT 19 44.43 50.72

6.30UNIT 20 44.53 50.83

UNIT 21

UNIT 22

Total OverFraming

56.75

6.29 44.43 50.72

6.30 44.53 50.83

56.38

56.38

56.75

hobrangeover

hobrangeover

hobrangeover

hobrangeover

-

Selwyn Block - Ground Floor Plan 1:50

Page 6: Preliminary - Not for Construction Purposes€¦ · Preliminary - Not for Construction Purposes TITLE: Site Plan Client: Address: Williams Corporation 466-468 Hagley Ave Christchurch

GSPublisherEngine 1468.15.18.100

Architectural Designers & Project Management Services

Revision Notes: TITLE: Selwyn Block - First Floor Plan

Client:

Address:

Williams Corporation

466-468 Hagley Ave

Christchurch Central

Christchurch

Scale:

Drawn By:

As Shown @ A1

Start Date:

Print Date:

27-Apr-18

28-Jun-18

SheetRevision RC8

7CC

ALL DIMENSIONS SHOWN ON DRAWINGS ,COUNCIL (PUBLIC) DRAIN

POSITIONS AND INVERTS SHALL BE CONFIRMED BY CONTRACTOR PRIOR

TO ANY WORKS COMMENCING. NOTIFY URBAN DESIGN NZ LTD SHOULD

DIMENSIONS OR POSITIONS VARY TO THAT SHOWN IMMEDIATELY.

IF GROUND CONDITIONS ARE QUESTIONABLE AND ARE NOT IN

ACCORDANCE WITH NZBC OR NZS 3604:2011REQUIREMENTS STOP

WORK AND CONTACT DESIGNER IMMEDIATELY.

NOTES:

ROOF TRUSS AND BRACING IS INDICATIVE ONLY AND SHALL BE

DESIGNED AND DETAILED BY APPROVED GANGNAIL TRUSS

MANUFACTURER IN ACCORDANCE WITH GANG-NAIL NZ LIMITED

NZ500 AND NZS 3604 : 2011

FOR WIND BRACING AND TYPE REFER TO ADJOINING SPECS

LINTELS TO BE 24% MAX MOISTURE CONTENT .TIMBER SIZES AS

PER NZS 3604 : 2011

KITCHEN JOINERY MANUFACTURER SHALL TAKE ' ON SITE '

MEASUREMENTS PRIOR TO FABRICATION.

FOR KITCHEN LAYOUT AND JOINERY REFER TO KITCHEN

MANUFACTURERS DOCUMENTS.

ALL GLASS TO BE AS PER NZS 4223 (PART 3 IN PARTICULAR)

ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE NZBC HAND

BOOK AND APPROVED DOCUMENTS ,NZS 3604 : 2011 AND LOCAL

TERRITORIAL AUTHORITY REQUIREMENTS.

WINDOW MANUFACTURERS SHALL CHECK ' ON SITE ' ALL WINDOW

OPENING SIZES PRIOR TO FABRICATION.

ALL PLUMBING AND DRAINAGE WORK SHALL BE IN ACCORDANCE

WITH NZBC REQUIREMENTS AND APPROVED DOCUMENTS.

VENTILATION TO FOUNDATION WALLS TO COMPLY TO NZS 3604

SECTION 4.8.

SHOULD THERE BE ANY AMBIGUITY ON THE DRAWINGS AND/OR

ACCOMPANYING DOCUMENTATION, OR THE MEANING(S) IS(ARE)

UNCLEAR OR IF THERE IS APPARENT CONFLICTING INFORMATION

SHOWN, IMMEDIATELY NOTIFY URBAN DESIGN NZ LTD BEFORE

COMMENCING THE WORK.

Z:\Urban Design NZ LTD\Urban Design Plans\ARCHICAD V18\423 - WSP - 466 Hagley Ave\Drawing Files\V18.422 - WSP - 466 Hagley Ave - RC9 - 20180628.pln

This Drawing remains the property of Urban Design Ltd.

It must not be used, copied or handed to any third party

without the written permission of Urban Design Ltd

The Contractor shall check and verify all dimensions and

levels prior to commencing any work.

All construction shall be in accordance with NZS 3604,

unless specifically Engineered, and in accordance with

the current Building Act.

Preliminary - Not for Construction Purposes

ALL PROPOSED SED CONCRETE WORK TO BE 25 MPa

44.53 m2 44.53 m2 44.43 m2

44.43 m2

860x2,1

75

860x2,1

75

D022,050 x 3,290

D022,200 x 3,290

860x2,1

75

D022,050 x 3,290

D022,200 x 3,290

860x2,1

75

D022,050 x 3,290

D022,050 x 3,290

D022,200 x 3,290

D022,200 x 3,290

810x1,980

810x1,980

2/810x1,9

80

810x1,980

810x1,980

550x1,980550x1,980

2/810x1,9

80

810x1,980

810x1,980

550x1,980

2/810x1,9

80

550x1,980

2/810x1,9

80

810x1,980

810x1,980

123456789

10

11

12

13

14

15

16

17

18

B

13

B

13

220 5,123 5,140 5,140 5,123 220

140 4,825 315 4,825 315 4,825 315 4,825 140

140 3,000 70 590 70 1,095 315 1,095 70 590 70 3,000 315 3,000 70 590 70 1,095 315 1,095 70 590 70 3,000 140

1,0

00

1,2

00

3,1

40

1,7

80

4,5

50

1,4

40

270

11,1

80

1,0

00

1,2

00

3,8

30

1,7

80

3,8

60

1,4

40

270

410

2,8

20

410

4,3

10

410

2,6

80

410

90

230

90

2,8

20

90

230

90

4,3

10

90

230

90

2,6

80

90

230

90

220 5,123 5,140 5,140 5,123 220

90130

140 4,825 315 4,825 315 4,825 315 4,825 140130

90

140 3,640 90 1,095 315 1,095 90 3,640 315 3,640 90 1,095 315 1,095 90 3,640 140

20,965

600 4,343 800 4,378 725 4,378 800 4,343 600

140

3,0

00

140

1,5

00

140

4,4

10

140

1,3

00

140

180

90

11,4

50

410

2,8

20

410

4,3

10

410

2,6

80

410

90

230

90

2,8

20

90

230

90

4,3

10

90

230

90

2,6

80

90

230

90

140

3,0

00

140

1,5

00

140

4,4

10

140

1,3

00

140

270

140

1,9

30

70

1,0

00

140

1,5

00

140

620

70

3,7

20

140

1,3

00

140

180

90

140 3,000 70 570 90 1,095 315 1,095 90 570 70 3,000 315 3,000 70 570 90 1,095 315 1,095 90 570 70 3,000 140

140

1,9

30

70

1,0

00

140

1,5

00

140

620

70

3,7

20

140

1,3

00

140

180

90

6.30 m26.30 m2 6.29 m26.29 m2

timber covers to heat pump units

dining / lounge

deck

dining / lounge

deck

hp

hp

hp

dining / loungedining / lounge

bathroom

kitchen

wr

built

in c

abin

et

hp

bedroom

built

in c

abin

et

hp

bathroom

kitchen

bedroom

wr

hwc &

store

entry

hwc &

store

hp

bathroom

wr

kitchen

built

in c

abin

et

entry

bedroom

entry

hwc &

store

hwc &

store

hp

bathroom

wr

kitchen

built

in c

abin

et

entry

bedroom

walkway

hp

FWF WFW F W

3/610x2,1753/610x2,175

2.28 m2 2.28 m2

UNIT 23UNIT 24

M N O P Q

A

C

D

G

E

B

UNIT 25

F

deckdeck

Deck NetArea

Unit AreaTotal

Net AreaTotal

UNIT 23

UNIT 24

UNIT 25

UNIT 26

Total OverFraming

UNIT 26

6.29 44.43 50.72

6.30 44.53 50.83

6.29 44.43 50.72

6.30 44.53 50.83

56.38

56.38

hobrangeover

hobrangeover

hobrangeover

hobrangeover

56.75

56.75

-

Selwyn Block - First Floor Plan 1:50

Page 7: Preliminary - Not for Construction Purposes€¦ · Preliminary - Not for Construction Purposes TITLE: Site Plan Client: Address: Williams Corporation 466-468 Hagley Ave Christchurch

GSPublisherEngine 1468.15.18.100

Architectural Designers & Project Management Services

Revision Notes: TITLE: Selwyn Block - Second Floor Plan

Client:

Address:

Williams Corporation

466-468 Hagley Ave

Christchurch Central

Christchurch

Scale:

Drawn By:

As Shown @ A1

Start Date:

Print Date:

27-Apr-18

28-Jun-18

SheetRevision RC8

8CC

ALL DIMENSIONS SHOWN ON DRAWINGS ,COUNCIL (PUBLIC) DRAIN

POSITIONS AND INVERTS SHALL BE CONFIRMED BY CONTRACTOR PRIOR

TO ANY WORKS COMMENCING. NOTIFY URBAN DESIGN NZ LTD SHOULD

DIMENSIONS OR POSITIONS VARY TO THAT SHOWN IMMEDIATELY.

IF GROUND CONDITIONS ARE QUESTIONABLE AND ARE NOT IN

ACCORDANCE WITH NZBC OR NZS 3604:2011REQUIREMENTS STOP

WORK AND CONTACT DESIGNER IMMEDIATELY.

NOTES:

ROOF TRUSS AND BRACING IS INDICATIVE ONLY AND SHALL BE

DESIGNED AND DETAILED BY APPROVED GANGNAIL TRUSS

MANUFACTURER IN ACCORDANCE WITH GANG-NAIL NZ LIMITED

NZ500 AND NZS 3604 : 2011

FOR WIND BRACING AND TYPE REFER TO ADJOINING SPECS

LINTELS TO BE 24% MAX MOISTURE CONTENT .TIMBER SIZES AS

PER NZS 3604 : 2011

KITCHEN JOINERY MANUFACTURER SHALL TAKE ' ON SITE '

MEASUREMENTS PRIOR TO FABRICATION.

FOR KITCHEN LAYOUT AND JOINERY REFER TO KITCHEN

MANUFACTURERS DOCUMENTS.

ALL GLASS TO BE AS PER NZS 4223 (PART 3 IN PARTICULAR)

ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE NZBC HAND

BOOK AND APPROVED DOCUMENTS ,NZS 3604 : 2011 AND LOCAL

TERRITORIAL AUTHORITY REQUIREMENTS.

WINDOW MANUFACTURERS SHALL CHECK ' ON SITE ' ALL WINDOW

OPENING SIZES PRIOR TO FABRICATION.

ALL PLUMBING AND DRAINAGE WORK SHALL BE IN ACCORDANCE

WITH NZBC REQUIREMENTS AND APPROVED DOCUMENTS.

VENTILATION TO FOUNDATION WALLS TO COMPLY TO NZS 3604

SECTION 4.8.

SHOULD THERE BE ANY AMBIGUITY ON THE DRAWINGS AND/OR

ACCOMPANYING DOCUMENTATION, OR THE MEANING(S) IS(ARE)

UNCLEAR OR IF THERE IS APPARENT CONFLICTING INFORMATION

SHOWN, IMMEDIATELY NOTIFY URBAN DESIGN NZ LTD BEFORE

COMMENCING THE WORK.

Z:\Urban Design NZ LTD\Urban Design Plans\ARCHICAD V18\423 - WSP - 466 Hagley Ave\Drawing Files\V18.422 - WSP - 466 Hagley Ave - RC9 - 20180628.pln

This Drawing remains the property of Urban Design Ltd.

It must not be used, copied or handed to any third party

without the written permission of Urban Design Ltd

The Contractor shall check and verify all dimensions and

levels prior to commencing any work.

All construction shall be in accordance with NZS 3604,

unless specifically Engineered, and in accordance with

the current Building Act.

Preliminary - Not for Construction Purposes

ALL PROPOSED SED CONCRETE WORK TO BE 25 MPa

44.53 m2 44.53 m2 44.43 m2

44.43 m2

860x2,1

75

860x2,1

75

D022,050 x 3,290

D022,200 x 3,290

860x2,1

75

D022,050 x 3,290

D022,200 x 3,290

860x2,1

75

D022,050 x 3,290

D022,050 x 3,290

D022,200 x 3,290

D022,200 x 3,290

810x1,980

810x1,980

2/810x1,9

80

810x1,980

810x1,980

550x1,980550x1,980

2/810x1,9

80

810x1,980

810x1,980

550x1,980

2/810x1,9

80

550x1,980

2/810x1,9

80

810x1,980

810x1,980

123456789

10

11

12

13

14

15

16

220 5,123 5,140 5,140 5,123 220

140 4,825 315 4,825 315 4,825 315 4,825 140

140 3,000 70 590 70 1,095 315 1,095 70 590 70 3,000 315 3,000 70 590 70 1,095 315 1,095 70 590 70 3,000 140

1,0

00

1,2

00

3,1

40

1,7

80

4,5

50

1,4

40

270

11,1

80

1,0

00

1,2

00

3,8

30

1,7

80

3,8

60

1,4

40

270

410

2,8

20

410

4,3

10

410

2,6

80

410

90

230

90

2,8

20

90

230

90

4,3

10

90

230

90

2,6

80

90

230

90

220 5,123 5,140 5,140 5,123 220

90130

140 4,825 315 4,825 315 4,825 315 4,825 140130

90

140 3,640 90 1,095 315 1,095 90 3,640 315 3,640 90 1,095 315 1,095 90 3,640 140

20,965

600 4,343 800 4,378 725 4,378 800 4,343 600

140

3,0

00

140

1,5

00

140

4,4

10

140

1,3

00

140

180

90

11,4

50

410

2,8

20

410

4,3

10

410

2,6

80

410

90

230

90

2,8

20

90

230

90

4,3

10

90

230

90

2,6

80

90

230

90

140

3,0

00

140

1,5

00

140

4,4

10

140

1,3

00

140

270

140

1,9

30

70

1,0

00

140

1,5

00

140

620

70

3,7

20

140

1,3

00

140

180

90

140 3,000 70 570 90 1,095 315 1,095 90 570 70 3,000 315 3,000 70 570 90 1,095 315 1,095 90 570 70 3,000 140

140

1,9

30

70

1,0

00

140

1,5

00

140

620

70

3,7

20

140

1,3

00

140

180

90

6.30 m26.30 m2 6.29 m26.29 m2

timber covers to heat pump units

dining / lounge

deck

dining / lounge

deck

walkway

hp

hp

hp

hp

dining / loungedining / lounge

bathroom

kitchen

wr

built

in c

abin

et

hp

bedroom

built

in c

abin

et

hp

bathroom

kitchen

bedroom

wr

hwc &

store

entry

hwc &

store

hp

bathroom

wr

kitchen

built

in c

abin

et

entry

bedroom

entry

hwc &

store

hwc &

store

hp

bathroom

wr

kitchen

built

in c

abin

et

entry

bedroom

deck deck

FWF WFW F W

3/610x2,1753/610x2,175

2.28 m2 2.28 m2

UNIT 27UNIT 28UNIT 29UNIT 30

Deck NetArea

Unit AreaTotal

Net AreaTotal

UNIT 27

UNIT 28

UNIT 29

UNIT 30

Total OverFraming

M N O P Q

A

C

D

G

E

B

F

deckdeck

6.29 44.43 50.72

6.30 44.53 50.83

6.29 44.43 50.72

6.30 44.53 50.83

56.38

56.38

hobrangeover

hobrangeover

hobrangeover

hobrangeover

56.75

56.75

-

Selwyn Block - Second Floor Plan 1:50

Page 8: Preliminary - Not for Construction Purposes€¦ · Preliminary - Not for Construction Purposes TITLE: Site Plan Client: Address: Williams Corporation 466-468 Hagley Ave Christchurch

GSPublisherEngine 1468.15.18.100

Architectural Designers & Project Management Services

Revision Notes: TITLE: Hagley Block - Elevations

Client:

Address:

Williams Corporation

466-468 Hagley Ave

Christchurch Central

Christchurch

Scale:

Drawn By:

As Shown @ A1

Start Date:

Print Date:

27-Apr-18

28-Jun-18

SheetRevision RC8

9CC

ALL DIMENSIONS SHOWN ON DRAWINGS ,COUNCIL (PUBLIC) DRAIN

POSITIONS AND INVERTS SHALL BE CONFIRMED BY CONTRACTOR PRIOR

TO ANY WORKS COMMENCING. NOTIFY URBAN DESIGN NZ LTD SHOULD

DIMENSIONS OR POSITIONS VARY TO THAT SHOWN IMMEDIATELY.

IF GROUND CONDITIONS ARE QUESTIONABLE AND ARE NOT IN

ACCORDANCE WITH NZBC OR NZS 3604:2011REQUIREMENTS STOP

WORK AND CONTACT DESIGNER IMMEDIATELY.

NOTES:

ROOF TRUSS AND BRACING IS INDICATIVE ONLY AND SHALL BE

DESIGNED AND DETAILED BY APPROVED GANGNAIL TRUSS

MANUFACTURER IN ACCORDANCE WITH GANG-NAIL NZ LIMITED

NZ500 AND NZS 3604 : 2011

FOR WIND BRACING AND TYPE REFER TO ADJOINING SPECS

LINTELS TO BE 24% MAX MOISTURE CONTENT .TIMBER SIZES AS

PER NZS 3604 : 2011

KITCHEN JOINERY MANUFACTURER SHALL TAKE ' ON SITE '

MEASUREMENTS PRIOR TO FABRICATION.

FOR KITCHEN LAYOUT AND JOINERY REFER TO KITCHEN

MANUFACTURERS DOCUMENTS.

ALL GLASS TO BE AS PER NZS 4223 (PART 3 IN PARTICULAR)

ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE NZBC HAND

BOOK AND APPROVED DOCUMENTS ,NZS 3604 : 2011 AND LOCAL

TERRITORIAL AUTHORITY REQUIREMENTS.

WINDOW MANUFACTURERS SHALL CHECK ' ON SITE ' ALL WINDOW

OPENING SIZES PRIOR TO FABRICATION.

ALL PLUMBING AND DRAINAGE WORK SHALL BE IN ACCORDANCE

WITH NZBC REQUIREMENTS AND APPROVED DOCUMENTS.

VENTILATION TO FOUNDATION WALLS TO COMPLY TO NZS 3604

SECTION 4.8.

SHOULD THERE BE ANY AMBIGUITY ON THE DRAWINGS AND/OR

ACCOMPANYING DOCUMENTATION, OR THE MEANING(S) IS(ARE)

UNCLEAR OR IF THERE IS APPARENT CONFLICTING INFORMATION

SHOWN, IMMEDIATELY NOTIFY URBAN DESIGN NZ LTD BEFORE

COMMENCING THE WORK.

Z:\Urban Design NZ LTD\Urban Design Plans\ARCHICAD V18\423 - WSP - 466 Hagley Ave\Drawing Files\V18.422 - WSP - 466 Hagley Ave - RC9 - 20180628.pln

This Drawing remains the property of Urban Design Ltd.

It must not be used, copied or handed to any third party

without the written permission of Urban Design Ltd

The Contractor shall check and verify all dimensions and

levels prior to commencing any work.

All construction shall be in accordance with NZS 3604,

unless specifically Engineered, and in accordance with

the current Building Act.

Preliminary - Not for Construction Purposes

ALL PROPOSED SED CONCRETE WORK TO BE 25 MPa

+16,700

Ground Floor

+16,700

Ground Floor

+19,542

First Floor

+19,542

First Floor

+22,384

Second Floor

+22,384

Second Floor

+16,700

Ground Floor

+16,700

Ground Floor

+19,542

First Floor

+19,542

First Floor

+22,384

Second Floor

+22,384

Second Floor

-

Hagley Block - North East Elevation 1:50

-

Hagley Block - North West Elevation 1:50

Page 9: Preliminary - Not for Construction Purposes€¦ · Preliminary - Not for Construction Purposes TITLE: Site Plan Client: Address: Williams Corporation 466-468 Hagley Ave Christchurch

GSPublisherEngine 1468.15.18.100

Architectural Designers & Project Management Services

Revision Notes: TITLE: Hagley Block - Elevations

Client:

Address:

Williams Corporation

466-468 Hagley Ave

Christchurch Central

Christchurch

Scale:

Drawn By:

As Shown @ A1

Start Date:

Print Date:

27-Apr-18

28-Jun-18

SheetRevision RC8

10CC

ALL DIMENSIONS SHOWN ON DRAWINGS ,COUNCIL (PUBLIC) DRAIN

POSITIONS AND INVERTS SHALL BE CONFIRMED BY CONTRACTOR PRIOR

TO ANY WORKS COMMENCING. NOTIFY URBAN DESIGN NZ LTD SHOULD

DIMENSIONS OR POSITIONS VARY TO THAT SHOWN IMMEDIATELY.

IF GROUND CONDITIONS ARE QUESTIONABLE AND ARE NOT IN

ACCORDANCE WITH NZBC OR NZS 3604:2011REQUIREMENTS STOP

WORK AND CONTACT DESIGNER IMMEDIATELY.

NOTES:

ROOF TRUSS AND BRACING IS INDICATIVE ONLY AND SHALL BE

DESIGNED AND DETAILED BY APPROVED GANGNAIL TRUSS

MANUFACTURER IN ACCORDANCE WITH GANG-NAIL NZ LIMITED

NZ500 AND NZS 3604 : 2011

FOR WIND BRACING AND TYPE REFER TO ADJOINING SPECS

LINTELS TO BE 24% MAX MOISTURE CONTENT .TIMBER SIZES AS

PER NZS 3604 : 2011

KITCHEN JOINERY MANUFACTURER SHALL TAKE ' ON SITE '

MEASUREMENTS PRIOR TO FABRICATION.

FOR KITCHEN LAYOUT AND JOINERY REFER TO KITCHEN

MANUFACTURERS DOCUMENTS.

ALL GLASS TO BE AS PER NZS 4223 (PART 3 IN PARTICULAR)

ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE NZBC HAND

BOOK AND APPROVED DOCUMENTS ,NZS 3604 : 2011 AND LOCAL

TERRITORIAL AUTHORITY REQUIREMENTS.

WINDOW MANUFACTURERS SHALL CHECK ' ON SITE ' ALL WINDOW

OPENING SIZES PRIOR TO FABRICATION.

ALL PLUMBING AND DRAINAGE WORK SHALL BE IN ACCORDANCE

WITH NZBC REQUIREMENTS AND APPROVED DOCUMENTS.

VENTILATION TO FOUNDATION WALLS TO COMPLY TO NZS 3604

SECTION 4.8.

SHOULD THERE BE ANY AMBIGUITY ON THE DRAWINGS AND/OR

ACCOMPANYING DOCUMENTATION, OR THE MEANING(S) IS(ARE)

UNCLEAR OR IF THERE IS APPARENT CONFLICTING INFORMATION

SHOWN, IMMEDIATELY NOTIFY URBAN DESIGN NZ LTD BEFORE

COMMENCING THE WORK.

Z:\Urban Design NZ LTD\Urban Design Plans\ARCHICAD V18\423 - WSP - 466 Hagley Ave\Drawing Files\V18.422 - WSP - 466 Hagley Ave - RC9 - 20180628.pln

This Drawing remains the property of Urban Design Ltd.

It must not be used, copied or handed to any third party

without the written permission of Urban Design Ltd

The Contractor shall check and verify all dimensions and

levels prior to commencing any work.

All construction shall be in accordance with NZS 3604,

unless specifically Engineered, and in accordance with

the current Building Act.

Preliminary - Not for Construction Purposes

ALL PROPOSED SED CONCRETE WORK TO BE 25 MPa

timber covers to heat pump units

+16,700

Ground Floor

+16,700

Ground Floor

+19,542

First Floor

+19,542

First Floor

+22,384

Second Floor

+22,384

Second Floor

+16,700

Ground Floor

+16,700

Ground Floor

+19,542

First Floor

+19,542

First Floor

+22,384

Second Floor

+22,384

Second Floor

-

Hagley Block - South East Elevation 1:50

-

Hagley Block - South West Elevation 1:50

Page 10: Preliminary - Not for Construction Purposes€¦ · Preliminary - Not for Construction Purposes TITLE: Site Plan Client: Address: Williams Corporation 466-468 Hagley Ave Christchurch

GSPublisherEngine 1468.15.18.100

Architectural Designers & Project Management Services

Revision Notes: TITLE: Selwyn Block - Elevations

Client:

Address:

Williams Corporation

466-468 Hagley Ave

Christchurch Central

Christchurch

Scale:

Drawn By:

As Shown @ A1

Start Date:

Print Date:

27-Apr-18

28-Jun-18

SheetRevision RC8

11CC

ALL DIMENSIONS SHOWN ON DRAWINGS ,COUNCIL (PUBLIC) DRAIN

POSITIONS AND INVERTS SHALL BE CONFIRMED BY CONTRACTOR PRIOR

TO ANY WORKS COMMENCING. NOTIFY URBAN DESIGN NZ LTD SHOULD

DIMENSIONS OR POSITIONS VARY TO THAT SHOWN IMMEDIATELY.

IF GROUND CONDITIONS ARE QUESTIONABLE AND ARE NOT IN

ACCORDANCE WITH NZBC OR NZS 3604:2011REQUIREMENTS STOP

WORK AND CONTACT DESIGNER IMMEDIATELY.

NOTES:

ROOF TRUSS AND BRACING IS INDICATIVE ONLY AND SHALL BE

DESIGNED AND DETAILED BY APPROVED GANGNAIL TRUSS

MANUFACTURER IN ACCORDANCE WITH GANG-NAIL NZ LIMITED

NZ500 AND NZS 3604 : 2011

FOR WIND BRACING AND TYPE REFER TO ADJOINING SPECS

LINTELS TO BE 24% MAX MOISTURE CONTENT .TIMBER SIZES AS

PER NZS 3604 : 2011

KITCHEN JOINERY MANUFACTURER SHALL TAKE ' ON SITE '

MEASUREMENTS PRIOR TO FABRICATION.

FOR KITCHEN LAYOUT AND JOINERY REFER TO KITCHEN

MANUFACTURERS DOCUMENTS.

ALL GLASS TO BE AS PER NZS 4223 (PART 3 IN PARTICULAR)

ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE NZBC HAND

BOOK AND APPROVED DOCUMENTS ,NZS 3604 : 2011 AND LOCAL

TERRITORIAL AUTHORITY REQUIREMENTS.

WINDOW MANUFACTURERS SHALL CHECK ' ON SITE ' ALL WINDOW

OPENING SIZES PRIOR TO FABRICATION.

ALL PLUMBING AND DRAINAGE WORK SHALL BE IN ACCORDANCE

WITH NZBC REQUIREMENTS AND APPROVED DOCUMENTS.

VENTILATION TO FOUNDATION WALLS TO COMPLY TO NZS 3604

SECTION 4.8.

SHOULD THERE BE ANY AMBIGUITY ON THE DRAWINGS AND/OR

ACCOMPANYING DOCUMENTATION, OR THE MEANING(S) IS(ARE)

UNCLEAR OR IF THERE IS APPARENT CONFLICTING INFORMATION

SHOWN, IMMEDIATELY NOTIFY URBAN DESIGN NZ LTD BEFORE

COMMENCING THE WORK.

Z:\Urban Design NZ LTD\Urban Design Plans\ARCHICAD V18\423 - WSP - 466 Hagley Ave\Drawing Files\V18.422 - WSP - 466 Hagley Ave - RC9 - 20180628.pln

This Drawing remains the property of Urban Design Ltd.

It must not be used, copied or handed to any third party

without the written permission of Urban Design Ltd

The Contractor shall check and verify all dimensions and

levels prior to commencing any work.

All construction shall be in accordance with NZS 3604,

unless specifically Engineered, and in accordance with

the current Building Act.

Preliminary - Not for Construction Purposes

ALL PROPOSED SED CONCRETE WORK TO BE 25 MPa

+16,700

Ground Floor

+16,700

Ground Floor

+19,542

First Floor

+19,542

First Floor

+22,384

Second Floor

+22,384

Second Floor

+16,700

Ground Floor

+16,700

Ground Floor

+19,542

First Floor

+19,542

First Floor

+22,384

Second Floor

+22,384

Second Floor

-

Selwyn Block - North Elevation 1:50

-

Selwyn Block - East Elevation 1:50

Page 11: Preliminary - Not for Construction Purposes€¦ · Preliminary - Not for Construction Purposes TITLE: Site Plan Client: Address: Williams Corporation 466-468 Hagley Ave Christchurch

GSPublisherEngine 1468.15.18.100

Architectural Designers & Project Management Services

Revision Notes: TITLE: Selwyn Block - Elevations

Client:

Address:

Williams Corporation

466-468 Hagley Ave

Christchurch Central

Christchurch

Scale:

Drawn By:

As Shown @ A1

Start Date:

Print Date:

27-Apr-18

28-Jun-18

SheetRevision RC8

12CC

ALL DIMENSIONS SHOWN ON DRAWINGS ,COUNCIL (PUBLIC) DRAIN

POSITIONS AND INVERTS SHALL BE CONFIRMED BY CONTRACTOR PRIOR

TO ANY WORKS COMMENCING. NOTIFY URBAN DESIGN NZ LTD SHOULD

DIMENSIONS OR POSITIONS VARY TO THAT SHOWN IMMEDIATELY.

IF GROUND CONDITIONS ARE QUESTIONABLE AND ARE NOT IN

ACCORDANCE WITH NZBC OR NZS 3604:2011REQUIREMENTS STOP

WORK AND CONTACT DESIGNER IMMEDIATELY.

NOTES:

ROOF TRUSS AND BRACING IS INDICATIVE ONLY AND SHALL BE

DESIGNED AND DETAILED BY APPROVED GANGNAIL TRUSS

MANUFACTURER IN ACCORDANCE WITH GANG-NAIL NZ LIMITED

NZ500 AND NZS 3604 : 2011

FOR WIND BRACING AND TYPE REFER TO ADJOINING SPECS

LINTELS TO BE 24% MAX MOISTURE CONTENT .TIMBER SIZES AS

PER NZS 3604 : 2011

KITCHEN JOINERY MANUFACTURER SHALL TAKE ' ON SITE '

MEASUREMENTS PRIOR TO FABRICATION.

FOR KITCHEN LAYOUT AND JOINERY REFER TO KITCHEN

MANUFACTURERS DOCUMENTS.

ALL GLASS TO BE AS PER NZS 4223 (PART 3 IN PARTICULAR)

ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE NZBC HAND

BOOK AND APPROVED DOCUMENTS ,NZS 3604 : 2011 AND LOCAL

TERRITORIAL AUTHORITY REQUIREMENTS.

WINDOW MANUFACTURERS SHALL CHECK ' ON SITE ' ALL WINDOW

OPENING SIZES PRIOR TO FABRICATION.

ALL PLUMBING AND DRAINAGE WORK SHALL BE IN ACCORDANCE

WITH NZBC REQUIREMENTS AND APPROVED DOCUMENTS.

VENTILATION TO FOUNDATION WALLS TO COMPLY TO NZS 3604

SECTION 4.8.

SHOULD THERE BE ANY AMBIGUITY ON THE DRAWINGS AND/OR

ACCOMPANYING DOCUMENTATION, OR THE MEANING(S) IS(ARE)

UNCLEAR OR IF THERE IS APPARENT CONFLICTING INFORMATION

SHOWN, IMMEDIATELY NOTIFY URBAN DESIGN NZ LTD BEFORE

COMMENCING THE WORK.

Z:\Urban Design NZ LTD\Urban Design Plans\ARCHICAD V18\423 - WSP - 466 Hagley Ave\Drawing Files\V18.422 - WSP - 466 Hagley Ave - RC9 - 20180628.pln

This Drawing remains the property of Urban Design Ltd.

It must not be used, copied or handed to any third party

without the written permission of Urban Design Ltd

The Contractor shall check and verify all dimensions and

levels prior to commencing any work.

All construction shall be in accordance with NZS 3604,

unless specifically Engineered, and in accordance with

the current Building Act.

Preliminary - Not for Construction Purposes

ALL PROPOSED SED CONCRETE WORK TO BE 25 MPa

timber covers to heat pump units

+16,700

Ground Floor

+16,700

Ground Floor

+19,542

First Floor

+19,542

First Floor

+22,384

Second Floor

+22,384

Second Floor

+16,700

Ground Floor

+16,700

Ground Floor

+19,542

First Floor

+19,542

First Floor

+22,384

Second Floor

+22,384

Second Floor

-

Selwyn Block - South Elevation 1:50

-

Selwyn Block - West Elevation 1:50

Page 12: Preliminary - Not for Construction Purposes€¦ · Preliminary - Not for Construction Purposes TITLE: Site Plan Client: Address: Williams Corporation 466-468 Hagley Ave Christchurch

GSPublisherEngine 1468.15.18.100

Architectural Designers & Project Management Services

Revision Notes: TITLE: Sections

Client:

Address:

Williams Corporation

466-468 Hagley Ave

Christchurch Central

Christchurch

Scale:

Drawn By:

As Shown @ A1

Start Date:

Print Date:

27-Apr-18

28-Jun-18

SheetRevision RC8

13CC

ALL DIMENSIONS SHOWN ON DRAWINGS ,COUNCIL (PUBLIC) DRAIN

POSITIONS AND INVERTS SHALL BE CONFIRMED BY CONTRACTOR PRIOR

TO ANY WORKS COMMENCING. NOTIFY URBAN DESIGN NZ LTD SHOULD

DIMENSIONS OR POSITIONS VARY TO THAT SHOWN IMMEDIATELY.

IF GROUND CONDITIONS ARE QUESTIONABLE AND ARE NOT IN

ACCORDANCE WITH NZBC OR NZS 3604:2011REQUIREMENTS STOP

WORK AND CONTACT DESIGNER IMMEDIATELY.

NOTES:

ROOF TRUSS AND BRACING IS INDICATIVE ONLY AND SHALL BE

DESIGNED AND DETAILED BY APPROVED GANGNAIL TRUSS

MANUFACTURER IN ACCORDANCE WITH GANG-NAIL NZ LIMITED

NZ500 AND NZS 3604 : 2011

FOR WIND BRACING AND TYPE REFER TO ADJOINING SPECS

LINTELS TO BE 24% MAX MOISTURE CONTENT .TIMBER SIZES AS

PER NZS 3604 : 2011

KITCHEN JOINERY MANUFACTURER SHALL TAKE ' ON SITE '

MEASUREMENTS PRIOR TO FABRICATION.

FOR KITCHEN LAYOUT AND JOINERY REFER TO KITCHEN

MANUFACTURERS DOCUMENTS.

ALL GLASS TO BE AS PER NZS 4223 (PART 3 IN PARTICULAR)

ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE NZBC HAND

BOOK AND APPROVED DOCUMENTS ,NZS 3604 : 2011 AND LOCAL

TERRITORIAL AUTHORITY REQUIREMENTS.

WINDOW MANUFACTURERS SHALL CHECK ' ON SITE ' ALL WINDOW

OPENING SIZES PRIOR TO FABRICATION.

ALL PLUMBING AND DRAINAGE WORK SHALL BE IN ACCORDANCE

WITH NZBC REQUIREMENTS AND APPROVED DOCUMENTS.

VENTILATION TO FOUNDATION WALLS TO COMPLY TO NZS 3604

SECTION 4.8.

SHOULD THERE BE ANY AMBIGUITY ON THE DRAWINGS AND/OR

ACCOMPANYING DOCUMENTATION, OR THE MEANING(S) IS(ARE)

UNCLEAR OR IF THERE IS APPARENT CONFLICTING INFORMATION

SHOWN, IMMEDIATELY NOTIFY URBAN DESIGN NZ LTD BEFORE

COMMENCING THE WORK.

Z:\Urban Design NZ LTD\Urban Design Plans\ARCHICAD V18\423 - WSP - 466 Hagley Ave\Drawing Files\V18.422 - WSP - 466 Hagley Ave - RC9 - 20180628.pln

This Drawing remains the property of Urban Design Ltd.

It must not be used, copied or handed to any third party

without the written permission of Urban Design Ltd

The Contractor shall check and verify all dimensions and

levels prior to commencing any work.

All construction shall be in accordance with NZS 3604,

unless specifically Engineered, and in accordance with

the current Building Act.

Preliminary - Not for Construction Purposes

ALL PROPOSED SED CONCRETE WORK TO BE 25 MPa

new selected .55mm corrugated roofing on self

supporting roof underlay (thermakraft) on 70 x 45

purlins @ 800 ctrs on manu trusses. refer to roofing plan

dining/loungedining/loungedining/loungedining/loungedining/loungestudio

dining/loungedining/loungedining/loungedining/loungedining/loungestudio

dining/loungedining/loungedining/loungedining/loungedining/loungestudio

+16,700

1 Ground Floor

+16,700

1 Ground Floor

+19,542

2 First Floor

+19,542

2 First Floor

+22,384

3 Second Floor

+22,384

3 Second Floor

R3.6 Batt type acoustic ceiling insulation

LIB 300.88 @ 600 ctrs with

accoustic insulation

Ribraft floor slab

25MPa FIRTH RP2519TC2 Firbre mix Concrete

G500 E SE62 Ductile mesh - TBC

75mm Hebel PowerpanelXL on 24mm

top hat rail on 7mm ecoply on 140x45

J-Frame LVL framing

10mm GIB wall lining & Mammoth R2.5

Batt type acoustic wall insulation as

necessary

75mm Hebel Power Floor on

12mm plywood substrate

10/12/6 double glazed new aluminium

joinery with compression seals - where

necessary for noise

Hebel intertenancy wall - refer

to details and manu. specs

13mm GIB ceiling lining on Rondo

ceiling battens

UNIT 1UNIT 2UNIT 3UNIT 4UNIT 5UNIT 6-A

UNIT 7UNIT 8UNIT 9UNIT 10UNIT 11UNIT 12-A

UNIT 13UNIT 14UNIT 15UNIT 16UNIT 17UNIT 18-A

new selected .55mm corrugated roofing on self

supporting roof underlay (thermakraft) on 70 x 45

purlins @ 800 ctrs on manu trusses. refer to roofing plan

dining / loungedining / lounge

dining / loungedining / lounge

dining / loungedining / lounge dining / lounge

dining / lounge

dining / loungedining / lounge

dining / lounge

dining / lounge

+16,700

1 Ground Floor

+16,700

1 Ground Floor

+19,542

2 First Floor

+19,542

2 First Floor

+22,384

3 Second Floor

+22,384

3 Second Floor

R3.6 Batt type acoustic ceiling insulation

LIB 300.88 @ 600 ctrs with

accoustic insulation

Ribraft floor slab

25MPa FIRTH RP2519TC2 Firbre mix Concrete

G500 E SE62 Ductile mesh - TBC

75mm Hebel PowerpanelXL on 24mm

top hat rail on 7mm ecoply on 140x45

J-Frame LVL framing

10mm GIB wall lining & Mammoth R2.5

Batt type acoustic wall insulation as

necessary

75mm Hebel Power Floor on

12mm plywood substrate

10/12/6 double glazed new aluminium

joinery with compression seals - where

necessary for noise

Hebel intertenancy wall - refer

to details and manu. specs

13mm GIB ceiling lining on Rondo

ceiling battens

10/12/6 double glazed new aluminium

joinery with compression seals - where

necessary for noise

UNIT 19UNIT 20UNIT 21UNIT 22-A

UNIT 23UNIT 24UNIT 25UNIT 26

deck

UNIT 27UNIT 28UNIT 29UNIT 30

deck

-

Hagley Block - Section AA 1:50

-

Selwyn Block - Section BB 1:50