Ray Casper - Foundations Engineer John Scanlon - Structural Engineer Jimmy Mounnarat - Fluid System Engineer Igor Babushkin - Solar Thermal Engineer Preliminary Design Review Austin Texas
Jan 19, 2016
Ray Casper - Foundations EngineerJohn Scanlon - Structural EngineerJimmy Mounnarat - Fluid System EngineerIgor Babushkin - Solar Thermal Engineer
Preliminary Design Review
Austin Texas
PDR Agenda• Introduction• Floor plan layout• House elevation drawings• Foundation analysis• Roof Truss analysis• Hydronic subsystem analysis• Heat Transfer analysis• Building and Flat Plate Collector• F-Chart analysis
Floor Plan Layout
House Elevation Drawings
Foundation Options
Poured Concrete Cement Block Low labor costQuickerRequires more materialPrevents water intrusionBetter heat retention
Low material costHigh Labor CostJoints allow for water
intrusionWeaker
Foundation Calculations 8’ Soil Depth 50’ x 30’ foundation 15 degree slope MMax on 50’ North wall
Soil Density 100lb/ft3
House load = 200lb/ft2
8 inch thick poured FOSCOMPRESSION = 87.2
FOSBENDING = 2.2
Roof Truss Analysis
A “Double Howe” truss using 2X8 beams proved to be suitable for our application.Roof pitch is variable depending upon FPC placement.
Hydronic Subsystem Analysis
• Schematic
• Head Loss, Pump size, Performance Curves
• Copper vs CPVC
• Cost Comparison
Hydronic Schematic
http://www.backwoodshome.com/articles/hackleman65.html
Head Loss
• Max Head Loss per system 51.4 ft.• Assuming 3 FPC’s.
Pump Size• 2 pump options in series.
• Taco pump – 2 x $219.75
• Grundfos pump – 2 x $269.75
Taco Cast Iron Model 009-F5
Grundfos UP26-96F
Cost Analysis
• Copper vs CPVC ~ 33%• Copper – corrodes, promotes
corrosion, expensive.• CPVC – higher reistance to heated
water, no soldering, no corrosion, cheaper.
• Pumps ~ 19%
Heat Transfer Analysis
Solar Thermal
Compare Two FPC’s Determine Number of Panels
Determine Angle
Alternative Energy– AE-26
• Roof angle is Bestat around 31 degrees
• Best area is around 54 ft2
Economics of the AE-26
Chose 6 Panels because of theThermal Output Data
Panel : $825.00Price per ft2: $34.88Area: 25.35 ft2
Sun Earth, Inc -- EP-21
• Very strange slop calculation,28 degrees is best slope
• Collector Panel area seems to be the best at 41.11 ft2
Economics of the EP-21
• Similarly to the previous choice, 6 panels are chosen
Panel: 609.97Price per ft2: $34.88Area: 21.35 ft2
Questions?