FEATURES • Trim function ±10%, single and duals • Small size, 1.13 in 2 (7.31 cm 2 ) • -55° to +125°C operation • 15 to 50 volt input • Low output ripple • 80 volts for 1 second transient protection • Magnetic isolation • Fixed high frequency switching • Inhibit function • Indefinite short circuit protection • Efficiency up to 78% typical DESCRIPTION The Interpoint® MSA+ Series™ of DC-DC converters offers up to 6 watts of power. The low profile MSA+ converters are manufactured in our fully certified and qualified MIL-PRF-38534 Class H production facility and packaged in hermetically sealed steel cases. Thick-film hybrid techniques provide military/aerospace reliability levels and optimum miniaturization. The hermetically sealed case is 1.065 by 1.065 inches with a height of 0.350 inches. Power density for the MSA+ Series converters is 15 watts per cubic inch. CONVERTER DESIGN The converters are switching regulators that use a flyback converter design with a constant switching frequency of 400 kHz typical. They are regulated, isolated units using a pulse width modulated topology and are built as high reliability thick-film hybrids. Isolation between input and output circuits is provided with a transformer in the forward power path and in the feedback control loop. Excellent input line transient response and audio rejection is achieved by an advanced feed-forward compensation technique. For dual outputs, negative output regulation is maintained by tightly coupled magnetics. Up to 4.8 watts, 80% of the total output power, is available from either output, provided that the opposite output is simultaneously carrying 20% of the total power in order to maintain the specified regulation on the negative output. A predictable current limit is accomplished by direct monitoring of the output load current, which results in a constant current output. Internal input and output filters eliminate the need for external capacitors for stable operation. WIDE VOLTAGE RANGE The MSA+ converters are designed to provide full power operation over a 15 to 50 volt input range. TRIM FUNCTION When trimming, ensure that neither the maximum current nor the maximum power is exceeded. The MSA+ singles and duals can be trimmed ±10% using trim pin 4. However, the 3.3 single model’s trim range is -5% and +10%. The dual outputs will then both be trimmed by the same percentage. See Figure 1 and Figure 2 on page 2 for external trim resistor selection. DYNAMIC RESPONSE The feed-forward compensation system provides excellent dynamic response and audio rejection. Audio rejection is typically 50 dB. SPAN VOLTAGE Our duals can be configured as a single output where the positive output is used as one rail and the negative output is used as the other rail. As an example the positive and negative 15 volt dual can be configured as a single 30 volt output. If the dual is configured as a positive 30 volt output the negative output would be used as system ground and the positive output would be used as the positive 30 volt output. In all cases Output Common of the converter is not connected. The maximum capacitance when using a span voltage on a dual is half the value specified for each output. SCREENING The converters are offered with /883 (Class H), ES or standard screening. For screening options and descriptions see Table 10 on page 13 and Table 11 on page 14. MODELS OUTPUT VOLTAGE (V) SINGLE DUAL 3.3 ±5 5 ±6.3 6.3 ±12 12 ±15 15 Crane Aerospace & Electronics Power Solutions MSA+ Single and Dual DC-DC Converters Page 1 of 14 MSA+ Rev AF Preliminary - 2020.05.29 PRELIMINARY - 15 TO 50 VOLT INPUT – 6 WATT Crane Aerospace & Electronics Power Solutions – Interpoint Products 16706 13th Avenue West, Lynnwood, WA 98037 +1 425.882.3100 • [email protected]www.craneae.com/interpoint
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
FEATURES• Trim function ±10%, single and duals
• Small size, 1.13 in2 (7.31 cm2)
• -55° to +125°C operation
• 15 to 50 volt input
• Low output ripple
• 80 volts for 1 second transient protection
• Magnetic isolation
• Fixed high frequency switching
• Inhibit function
• Indefinite short circuit protection
• Efficiency up to 78% typical
DESCRIPTIONThe Interpoint® MSA+ Series™ of DC-DC converters offers up to 6 watts of power. The low profile MSA+ converters are manufactured in our fully certified and qualified MIL-PRF-38534 Class H production facility and packaged in hermetically sealed steel cases. Thick-film hybrid techniques provide military/aerospace reliability levels and optimum miniaturization. The hermetically sealed case is 1.065 by 1.065 inches with a height of 0.350 inches. Power density for the MSA+ Series converters is 15 watts per cubic inch. Converter DesignThe converters are switching regulators that use a flyback converter design with a constant switching frequency of 400 kHz typical. They are regulated, isolated units using a pulse width modulated topology and are built as high reliability thick-film hybrids. Isolation between input and output circuits is provided with a transformer in the forward power path and in the feedback control loop.
Excellent input line transient response and audio rejection is achieved by an advanced feed-forward compensation technique. For dual outputs, negative output regulation is maintained by tightly coupled magnetics. Up to 4.8 watts, 80% of the total output power, is available from either output, provided that the opposite output is simultaneously carrying 20% of the total power in order to maintain the specified regulation on the negative output.
A predictable current limit is accomplished by direct monitoring of the output load current, which results in a constant current output. Internal input and output filters eliminate the need for external capacitors for stable operation.
WiDe voltage rangeThe MSA+ converters are designed to provide full power operation over a 15 to 50 volt input range.
trim FunCtionWhen trimming, ensure that neither the maximum current nor the maximum power is exceeded.
The MSA+ singles and duals can be trimmed ±10% using trim pin 4. However, the 3.3 single model’s trim range is -5% and +10%. The dual outputs will then both be trimmed by the same percentage.
See Figure 1 and Figure 2 on page 2 for external trim resistor selection.
DynamiC responseThe feed-forward compensation system provides excellent dynamic response and audio rejection. Audio rejection is typically 50 dB.
span voltageOur duals can be configured as a single output where the positive output is used as one rail and the negative output is used as the other rail. As an example the positive and negative 15 volt dual can be configured as a single 30 volt output. If the dual is configured as a positive 30 volt output the negative output would be used as system ground and the positive output would be used as the positive 30 volt output. In all cases Output Common of the converter is not connected. The maximum capacitance when using a span voltage on a dual is half the value specified for each output.
sCreeningThe converters are offered with /883 (Class H), ES or standard screening. For screening options and descriptions see Table 10 on page 13 and Table 11 on page 14.
inhibit FunCtionThe inhibit feature can be used to disable internal switching and inhibit the unit’s output. Inhibiting in this manner results in low standby current and no generation of switching noise.
The converter is inhibited when the inhibit pin is pulled below 0.8 volts and enabled when its inhibit pin is left floating. An external inhibit interface should be used to pull the converter’s inhibit pin below 0.8 volts while sinking the maximum inhibit current. It also allows the inhibit pin to float high to enable the converter. A voltage should not be applied to the inhibit pin. The open circuit output voltage associated with the inhibit pin is 9.5 to 11.5 volts. In the inhibit mode, a maximum of 4 is sourced from the inhibit pin. See Figure 4 and Figure 3 on page 3.
unDervoltage loCkoutUndervoltage lockout helps keep system current levels low during initialization or re-start operations. A low voltage lockout feature keeps the converter shutdown below approximately 12.7 volts to ensure smooth initialization.
transient proteCtionThe MSA+ can withstand short term transients of up to 80 volts for up to one second without damage.
mil-stD-461Use our FMCE-0328 filter to pass the CE03 requirements of MIL-STD-461C.
paCkagingThe MSA+ Series converters are packaged in hermetically sealed, seam-sealed steel cases which provide EMI/RFI shielding. The small size, 1.065 x 1.065 x 0.350 inches (27.05 x 27.05 x 8.89 mm), saves space and weight in critical applications. They are available in non-flange or offset flange cases. See Figure 8 on page 12 and Figure 7 on page 11.
MSA+ Trim Up Formulas for Singles and DualsVout = desired output voltage; Rt = trim resistor
3.3 V: Rt = 23760
-60000
Vout - 3.3 5 V: Rt = 36000
-60000 Vout - 5 6.3 V: Rt = 76860
-110000 Vout - 6.3 12 V: Rt = 120000
-91000 Vout - 12 15 V: Rt = 156000
-91000 Vout - 15
MSA+ Trim Down Formulas for Singles and DualsVout = desired output voltage; Rt = trim resistor
3.3 V: Rt = _ 53460
-72000
Vout - 3.3 5 V: Rt = _ 54000
-78000 Vout - 5 6.3 V: Rt = _ 153720
-146600
Vout - 6.3 12 V: Rt = — 600000
-151000
Vout - 12 15 V: Rt = — 1014000
-169000
Vout - 15
Figure 1: msa+ trim DoWn Figure 2: msa+ trim up
Crane Aerospace & Electronics Power Solutions
MSA+ Single and Dual DC-DC Converters
PRElIMINARy - 15 TO 50 VOlT INPUT – 6 WATT
www.craneae.com/interpoint Page 2 of 14MSA+ Rev AF Preliminary - 2020.05.29
EXTERNAL TRIM CONNECTION
RL
OUTPUTCOMMON
MSA+ TRIM DOWN
2
4
1
7
6+VIN
INPUTCOMMON
TRIM
POSITIVEOUTPUT
RT
EXTERNAL TRIM CONNECTION
RL
OUTPUTCOMMON
MSA+ TRIM UP
2
4
1
7
6+VIN
INPUTCOMMON
TRIM
POSITIVEOUTPUT
RT
Rcs
UNDER VOLTAGELOCKOUT &
PRIMARY SUPPLY
VOLTAGE & CURRENT
AMPLIFIERS
ISOLATION
MAIN GATEDRIVE
PWMCONTROL
+VOUT
OUT COM
+28 VIN
IN COM
INHIBIT
T1
CASE
FEEDBACK
SECONDARYSUPPLY
MSA+ Dual Series™ 6 WattsBlock Diagram
CASE
-VOUT
Rs
Rs
TRIM
Figure 3: bloCk Diagram msa+ single output
Rcs
UNDER VOLTAGELOCKOUT &
PRIMARY SUPPLY
VOLTAGE & CURRENT
AMPLIFIERS
ISOLATION
MAIN GATEDRIVE
PWMCONTROL
+VOUT
+28 VIN
IN COM
INHIBIT
T1
CASE
T2
SECONDARYSUPPLY
Rsense
MSA+ Singles Series™ 6 WattsBlock Diagram
CASE
OUT COM
TRIM
Figure 4: bloCk Diagram msa+ Dual output
Crane Aerospace & Electronics Power Solutions
MSA+ Single and Dual DC-DC Converters
PRElIMINARy - 15 TO 50 VOlT INPUT – 6 WATT
www.craneae.com/interpoint Page 3 of 14MSA+ Rev AF Preliminary - 2020.05.29
Figure 5: msa+ pin out bottom vieW
BOTTOM VIEWMSA+
8 7 6
54321
Dot on top of case indicates pin one.
Dotted line outlines indicateflanged case option.
See Figure 7 on page 11 and Figure 8 on page 12.
MSA+ PINS NOT IN USEInhibit Leave unconnected
“No Connection” pin Leave unconnected
Trim Leave unconnected
PIN OUTPin Single Output Dual Output
1 Positive Output Positive Output
2 Output Common Output Common
3 No Connection Negative Output
4 Trim Trim
5 Inhibit Inhibit
6 Positive Input Positive Input
7 Input Common Input Common
8 Case Ground Case Ground
table 1: msa+ pin out
table 2: msa+ pins not in use
Crane Aerospace & Electronics Power Solutions
MSA+ Single and Dual DC-DC Converters
PRElIMINARy - 15 TO 50 VOlT INPUT – 6 WATT
www.craneae.com/interpoint Page 4 of 14MSA+ Rev AF Preliminary - 2020.05.29
MODEl NUMBERING KEyMSA+ 28 12 SF / ES
Base Model
Input VoltageOutput Voltage
Number of Outputs(S = single, D = dual)
(R = decimal point, 3R3 = 3.3 Vout)
Screening(Standard screening has no designatorin this position.)
MODEl NUMBER OPTIONS 1 To deTermine The model number enTer one opTion from each caTegory in The form below.
FIll IN FOR MODEl # 6 MSA+28__________ __________ /
Noes1. See Figure 6 above for an example of a model number. 2. Output Voltage: An R indicates a decimal point. 3R3 is 3.3 volts out. The values of 3.3 is only available in single output models. 3. Number of Outputs: S is a single output and D is a dual output.4. Case Options: For the standard case (Figure 7 on page 11) leave the Case Option blank. For the flanged case option (Figure 8 on page 12), insert the letter F in the
Case Option position. 5. Screening: For standard screening leave the screening option blank. For other screening options, insert the desired screening level. For more information see Table 10
on page 13 and Table 11 on page 14.6. If ordering by model number add suffix “-Q” to request solder dipped leads (MSA+2805S/ES-Q).
table 3: smD number Cross reFerenCe
Figure 6: msa+ moDel numbering key
SMD NUMBERSSTandard microcircuiT
drawing (Smd)mSa+ Similar parT
IN PROCESS MSA+283R3S/883
IN PROCESS MSA+2805S/883
IN PROCESS MSA+286R3S/883
IN PROCESS MSA+2812S/883
IN PROCESS MSA+2815S/883
IN PROCESS MSA+2805D/883
IN PROCESS MSA+286R3D/83
IN PROCESS MSA+2812D/883
IN PROCESS MSA+2815D/883
For exact specifications for an SMD product, refer to the SMD drawing. SMDs can be downloaded from: https://landandmaritimeapps.dla.mil/programs/smcr
table 4: moDel number options
Crane Aerospace & Electronics Power Solutions
MSA+ Single and Dual DC-DC Converters
PRElIMINARy - 15 TO 50 VOlT INPUT – 6 WATT
www.craneae.com/interpoint Page 5 of 14MSA+ Rev AF Preliminary - 2020.05.29
PARAMETER CONDITIONS MIN TYP MAX UNITSLEAD SOLDERING TEMPERATURE 10 SECONDS MAX. PER LEAD — — 300 °C
STORAGE TEMPERATURE 1 -65 — +150 °C
CASE OPERATING FULL POWER -55 — +125°C
TEMPERATURE ABSOLUTE 1 -55 — +135
DERATING OUTPUT POWER/CURRENT 1 LINEARLY From 100% at 125°C to 0% at 135°C
ISOLATION: INPUT TO OUTPUT, INPUT TO@ 500 VDC AT 25°C 100 — — Megohms
CASE, OUTPUT TO CASE 2
INPUT TO OUTPUT CAPACITANCE 1 — 50 — pF
UNDERVOLTAGE LOCKOUT 1 — 13 — V
CURRENT LIMIT 1, 3 % OF FULL LOAD — 130 — %
AUDIO REJECTION 1 — 50 — dB
SWITCHING FREQUENCY -55° TO +125°C 350 — 450 kHz
INHIBIT ACTIVE LOW (OUTPUT DISABLED) INHIBIT PIN PULLED LOW — — 0.8 V
Do not apply a voltage to the inhibit pin. 4 INHIBIT PIN SOURCE CURRENT 1 — — 4 mA
REFERENCED TO INPUT COMMON
INHIBIT ACTIVE HIGH (OUTPUT ENABLED)Do not apply a voltage to the inhibit pin. 4
INHIBIT PIN CONDITION OPEN COLLECTOR OR UNCONNECTED
OPEN PIN VOLTAGE 1 9.5 — 11.5 V
Notes1. Guaranteed by qualification test and/or analysis. Not a production test.2. When testing isolation, input pins are tied together and output pins are tied together. They are tested against each other and against case. Discharge
the pins before and after testing.3. Current limit is defined as the point at which the output voltage decreases by 1%. Dual outputs: The over-current limit will trigger when the sum of the currents from both outputs reaches 130% (typical value) of the maximum rated
“total” current of both outputs.4. An external inhibit interface should be used to pull the inhibit low or leave it floating. The inhibit pin can be left unconnected if not used.
Crane Aerospace & Electronics Power Solutions
MSA+ Single and Dual DC-DC Converters
PRElIMINARy - 15 TO 50 VOlT INPUT – 6 WATT
www.craneae.com/interpoint Page 6 of 14MSA+ Rev AF Preliminary - 2020.05.29
Notes1. Guaranteed by characterization test and/or analysis. Not a production test.2. Indefinite short circuit protection not guaranteed above 125°C (case).3. Recovery time is measured from application of the transient to point at which Vout is
within 1% of Vout at final value.
4. Step load test is performed at 10 microseconds typical.5. Step line test is performed at 100 microseconds ± 20 microseconds.
MSA+ SINGLE OUTPUT MODELS MSA+283R3S MSA+2805S MSA+286R3SUNITSPARAMETER CONDITIONS MIN TYP MAX MIN TYP MAX MIN TYP MAX
OUTPUT VOLTAGE 3.15 3.30 3.45 4.80 5.00 5.20 6.10 6.30 6.50 V
OUTPUT CURRENT VIN = 15 to 50 0 — 1500 0 — 1200 0 — 950 mA
Notes1. Guaranteed by characterization test and/or analysis. Not a production test.2. Indefinite short circuit protection not guaranteed above 125°C (case).3. Recovery time is measured from application of the transient to point at
which Vout is within 1% of Vout at final value.
4. Step load test is performed at 10 microseconds typical.5. Step line test is performed at 100 microseconds ± 20 microseconds.
0 TO 28 VIN, FULL LOAD OVERSHOOT 1 — — 200 — — 200 mV pk
CAPACITIVE LOAD 1, 8
TC = 25°CNO EFFECT ON DC PERFORMANCE — — 500 — — 500 µF
Notes1. Guaranteed by characterization test and/or analysis. Not a production test.2. Up to 4.8 watts (80% of full power) is available from either output providing the
opposite output is carrying 20% of total power.3. Shows regulation effect on the minus output during defined cross loading conditions. 4. Indefinite short circuit protection not guaranteed above 125°C (case).
5. Recovery time is measured from application of the transient to point at which Vout is within 1% of Vout at final value.
6. Step load test is performed at 10 microseconds typical.7. Step line test is performed at 100 microseconds ± 20 microseconds.8. Each output.
0 TO 28 VIN, FULL LOAD OVERSHOOT 1 — — 200 — — 200 mV pk
CAPACITIVE LOAD 1, 8
TC = 25°CNO EFFECT ON DC PERFORMANCE — — 500 — — 500 µF
Notes1. Guaranteed by characterization test and/or analysis. Not a production test.2. Up to 4.8 watts (80% of full power) is available from either output providing the
opposite output is carrying 20% of total power.3. Shows regulation effect on the minus output during defined cross loading conditions. 4. Indefinite short circuit protection not guaranteed above 125°C (case).
5. Recovery time is measured from application of the transient to point at which Vout is within 1% of Vout at final value.
6. Step load test is performed at 10 microseconds typical.7. Step line test is performed at 100 microseconds ± 20 microseconds.8. Each output.
www.craneae.com/interpoint Page 10 of 14MSA+ Rev AF Preliminary - 2020.05.29
0.0000.132 (3.35)
0.932 (23.67)
0.00
00.
132
(3.3
5)
8 7 6
54321
0.33
2 (8
.43)
0.53
2 (1
3.51
)
0.73
2 (1
8.59
)
0.93
2 (2
3.67
)
0.025(0.64)
dia.0.
000
0.35
0 (8
.89)
BOTTOM VIEW CASE C4 MSA+
0.25
±0.
01(6
.35
±0.2
5)
Weight: 23 grams maximum
Case dimensions in inches (mm)Tolerance ±0.005 (0.13) for three decimal places ±0.01 (0.3) for two decimal places unless otherwise specified
CAUTIONHeat from reflow or wave soldering may damage the device. Solder pins individually with heat application not exceeding 300°C for 10 seconds per pin.
MaterialsHeader Cold Rolled Steel/Nickel/GoldCover Cold Rolled Steel/NickelPins #52 alloy, gold, compression glass seal Gold plating of 50 - 100 microinches included in pin diameter Seal hole: 0.070 ±0.003 (1.78 ±0.08)
Please refer to the numerical dimensions for accuracy.
Case C4 MSA+, Rev B, 2020.03.16 case wtMSA+ SCD 60371-007 and -009 is 1.065, ±0.005. Nominal was used in this drawing.
1.065 (27.05)
1.06
5 (2
7.05
)
Seam SealSquared corner and dot ontop of case indicates pin one.
Figure 7: msa+ Case Dimensions
Crane Aerospace & Electronics Power Solutions
MSA+ Single and Dual DC-DC Converters
PRElIMINARy - 15 TO 50 VOlT INPUT – 6 WATT
www.craneae.com/interpoint Page 11 of 14MSA+ Rev AF Preliminary - 2020.05.29
BOTTOM VIEW CASE D6 MSA+ OFFSET FLANGE
Weight: 25 grams maximum
Case dimensions in inches (mm)Tolerance ±0.005 (0.13) for three decimal places ±0.01 (0.3) for two decimal places unless otherwise specified
CAUTIONHeat from reflow or wave soldering may damage the device. Solder pins individually with heat application not exceeding 300°C for 10 seconds per pin.
MaterialsHeader Cold Rolled Steel/Nickel/GoldCover Cold Rolled Steel/NickelPins #52 alloy, gold, compression glass seal Gold plating of 50 - 100 microinches included in pin diameter Seal hole: 0.070 ±0.003 (1.78 ±0.08)
Please refer to the numerical dimensions for accuracy.
Case D6 MSA+ flange, offset, Rev A, 2020.03.16 case wtMSA+ SCD 60371-007 and -009 is 1.065, ±0.005. Nominal was used in this drawing.
2 x R 0.130 (3.30)
2 x Dia 0.129 ±0.002 (3.28 ±0.05)
Flanged cases: Designator "F" required in Case Option position of model number
0.06
0 (1
.52)
(1.660 (42.16))
0.0000.132 (3.35)0.283 (7.19)
0.783 (19.89)0.932 (23.67)
0.00
00.
1675
0.13
2 (3
.35)
8 7 6
54321
0.33
2 (8
.43)
0.53
2 (1
3.51
)
0.73
2 (1
8.59
)
0.93
2 (2
3.67
)
0.025(0.640)
dia.
0.00
0
0.35
0 (8
.89)
0.20
5 ±0
.01
(6.3
5 ±0
.25)
Dot on top of caseindicates pin one.
1.065 (27.05)
1.06
5 (2
7.05
)
1.23
3 (3
1.31
)
Seam Seal
Figure 8: msa+ oFFset FlangeD Case Dimensions
Crane Aerospace & Electronics Power Solutions
MSA+ Single and Dual DC-DC Converters
PRElIMINARy - 15 TO 50 VOlT INPUT – 6 WATT
www.craneae.com/interpoint Page 12 of 14MSA+ Rev AF Preliminary - 2020.05.29
table 10: element evaluation
elemenT eValuaTion 1 high reliabiliTy /883 (claSS h) Qml
claSS h /883
componenT-leVel TeST performed m/S 2 p 3
Element Electrical ■ ■
Visual ■ ■
Internal Visual ■
Final Electrical ■ ■
Wire Bond Evaluation ■ ■
Notes1. Element evaluation does not apply to standard and /ES product. 2. M/S = Active components (microcircuit and semiconductor die).3. P = Passive components, Class H element evaluation. Not applicable to
standard and /ES element evaluation.
Element Evaluation High Reliability DC-DC
Crane Aerospace & Electronics Power Solutions
MSA+ Single and Dual DC-DC Converters
PRElIMINARy - 15 TO 50 VOlT INPUT – 6 WATT
www.craneae.com/interpoint Page 13 of 14MSA+ Rev AF Preliminary - 2020.05.29
table 11: environmental sCreening
enVironmenTal Screening high reliabiliTy STandard, /eS and /883 (claSS h)
non-Qml 1 claSS h Qml 2
TeST performed STandard /eS /883
Pre-cap Inspection, Method 2017, 2032 ■ ■ ■
Temperature Cycle (10 times)
Method 1010, Cond. C, -65°C to +150°C, ambient ■
Method 1010, Cond. B, -55°C to +125°C, ambient ■
Constant Acceleration
Method 2001, 3000 g ■
Method 2001, 500 g ■
PIND, Test Method 2020, Cond. A ■ 3
Burn-in Method 1015, +125°C case, typical 4
96 hours ■
160 hours ■
Final Electrical Test, MIl-PRF-38534, Group A,
Subgroups 1 through 6, -55°C, +25°C, +125°C case ■
Subgroups 1 and 4, +25°C case ■ ■
Hermeticity Test, Method 1014
Gross Leak, Cond. C1, fluorocarbon ■ ■
Fine Leak, Cond. A2, helium ■ ■
Gross Leak, Dip ■
Final visual inspection, Method 2009 ■ ■ ■
Test methods are referenced to MIL-STD-883 as determined by MIL-PRF-38534.
Notes1. Non-QML products may not meet all of the requirements of MIL-PRF-38534.2. All processes are QML qualified and performed by certified operators.3. Not required by DLA but performed to assure product quality.4. Burn-in temperature designed to bring the case temperature to +125°C minimum.
Burn-in is a powered test.
For standard Hi Rel converters and filters with SMD numbers. Does not have SX or CH
Crane Aerospace & Electronics Power Solutions
Quality Assurance and CertificationAPPlICATION NOTE