Precision Turbine Flowmeters SPONSLER, INC. • A Unit of IDEX Corporation 2363 Sandifer Blvd. • Westminster, SC 29693 (864) 647-2065 • www.sponsler.com ■ Flowrates: .25 to 12000 GPM 35 to 12000 ACFM ■ Temperature Range: -430 to +1000˚ F -256.7˚ C to 537.8˚ C ■ Linear Output ■ High Resolution ■ Standard and Custom End-fittings Design Applications ■ Liquid and Gas Measurement ■ Batching ■ Blending ■ Filling ■ Process Control
8
Embed
Precision Turbine Flowmeters - Gas Equipment Mete… · Precision Turbine Flowmeters ... flow system. The AC signal output ... 30 mV peak to peak at the minimum of repeatable flow.
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Precision Turbine Flowmeters
SPONSLER, INC. • A Unit of IDEX Corporation2363 Sandifer Blvd. • Westminster, SC 29693(864) 647-2065 • www.sponsler.com
■ Flowrates: .25 to 12000 GPM35 to 12000 ACFM
■ Temperature Range: -430 to +1000˚ F-256.7˚ C to 537.8˚ C
■ Linear Output
■ High Resolution
■ Standard and Custom End-fittings
Design Applications■ Liquid and Gas Measurement
■ Batching
■ Blending
■ Filling
■ Process Control
The Sponsler Precision TurbineFlowmeter measures volume bya contour mounted turbine in theflow system. The AC signal outputis detected by a transducer andinterpreted by various electronicdevices used for flow rate indicationand totalization. Sponsler PrecisionTurbine Flowmeters are engineeredand manufactured to handleproblems of viscosity, corrosivemedia, extreme temperatures, andhazardous materials. The compact,rugged design has established a newstandard for flow measurement byexceeding the expectations of ourindustry for higher accuracy andreliability in all operating conditions.
Sponsler engineers design flowsystems to meet the needs of eachcustomer’s application. Theseprocesses can be automatic,semi-automatic, or manual for batchor process control, blending, andfilling systems including simple rateindication and totalization. Standardor custom electronic instrumentationis available for a wide range ofapplications.
At Sponsler, we believe that nomatter what the application, ourcommitment to quality and serviceto our customers means that weproduce the best flowmeter on theplanet.
Typical Arrangement of Flowmeter and Readout Instrument
SPONSLER, INC. • A Unit of IDEX Corporation2363 Sandifer Blvd. • Westminster, SC 29693(864) 647-2065 • www.sponsler.com
CHARACTERISTICS CURVE
% V
ALU
E A
T RA
TE O
F FL
OW
TYPICAL % OF RATED FLOW (GPM)
Cycles per Gallon
Pressu
re Dro
p
Voltage and Frequency
50 100 150
150
100
50
0
TYPIC
AL
K F
ACTO
R (P
ULS
E/G
AL)
TYPICAL % OF RATED FLOW (GPM)
TYPICAL VISCOSITY CURVE(1 1/2" Liguid Flowmeter)
0 100
1 Centistoke10
0 Ce
ntis
toke
s
Pickup Coil:Temperature from -450 ˚F (-232.2˚C) to 450 ˚F (267.8 ˚C);
Optional to 1000 ˚F (537.8 ˚C)
Standard Bearing ChoicesIncludeStainless Steel Ball
Standard FlowStraighteners:Upstream and Downstreamfor Accuracy
Materials Of Construction:304 Stainless Steel
316 Stainless Steel
(Consult Factory for other materials.)
Features
• High pressure applications
• Interfaces with manual,semiautomated or completelyautomated systems
• Custom and standard designs
• Material compatible withapplication
• Manufactured in the USA
• Wide choice of bearings includingcarbide for compatability
Specifications:• Linearity: +/- 0.1%
• Premium Linearity: +/- 0.2%(over a specific range)
• Repeatability: +/- 0.5%
• Premium Repeatability: +/- 0.2%(over a specific range)
• Temperature: -450˚F to 450˚Fstandard with optional 1000 ˚F
Temperature: -267.8˚C to 232.2˚Cstandard with optional 537.8˚C
• Materials: Sponsler Precision TurbineFlowmeters are constructed of 300 and 400 seriesstainless steel. A variety of other materials areavailable to satisfy most applicationsincluding CPVC, Teflon, and Kynar forcorrosive materials.
• Electrical Output: A minimum of30 mV peak to peak at the minimumof repeatable flow.
• Pressure Drop: 4 psi at nominalrated flow range
• End-Fittings: AN series of 37˚, flare tube
Liquids
* Approximate Weight for flanged Flowmeters
Sizing Chart
SPONSLER, INC. • A Unit of IDEX Corporation2363 Sandifer Blvd. • Westminster, SC 29693(864) 647-2065 • www.sponsler.com
(MS-33656), NPT, and ANSI flanges. Othersavailable upon request.
• Operating Pressure: Accommodates unlimitedpressure depending on the end-fittings.
• Calibration: Sponsler Precision TurbineFlowmeters are furnished with stand fluidcalibration. Special calibrations available.
Sponsler Precision Turbine Gas Flowmeters are designedto measure actual cubic feet or actual volume passingthrough the flowmeter. Before sizing a flowmeter, it isnecessary to convert flow units (i.e. SCFM, LPM, etc.) toactual measured volume. To convert to actual measurevolume (ACFM) from standard volume (SCFM), use thefollowing formula:
ACFM = SCFM x 14.7 / Pa x Ta / 530Whereas:
ACFM = actual cubic feet per minutemeasured gas flow
SCFM = standard cubic feet perminute measured gas flow
Pa = Operating Pressure in PSIA(Note: PSIA = PSIG + 14.7)
Ta = Temperature in degreesRankine = F + 460
Note: For more information, visitthe Application Tools section of ourwebsite at www.sponsler.comor consult factory.
Specifications:• Accuracy of +/- 1% linear
• Repeatability of +/- .25%
• Temperature Range -450˚F to 450˚F standard withoptional 1000 ˚F
Temperature Range -267.8˚C to 232.2˚C standardwith optional 537.8˚C
Services• Field Service• Calibration• Repair• Customer Service• Training and Education• Technical Support
OUR COMMITMENT TO QUALITYAt Sponsler, Inc., we are committed to designing,manufacturing, and calibrating the highest quality flow measuringproducts. All associates share this commitment to continualimprovement, customer satisfaction, and quality.
Manufacturing operations at Sponsler, Inc. include precision machining and electronics manufacturing combinedwith rigid, comprehensive calibration and testing procedures. These operations ensure that every Sponsler productconforms to the highest quality standards and applicable regulatory requirements. With commitment to competitivepricing, devotion to quality, superior customer service, and a reliable delivery of products, Sponsler, Inc. strives tocombine technologically, innovative products with the highest rate of reliability.
Sponsler offers on-site field service for our Flowmeasurement and delivery systems.