Photo/isometric drawing provided by manufacturer Precast Ground Beam and Flooring System Description of Product Balfour Beatty Ground Engineering Precast Ground Beam System is a ground beam for carrying wall and floor loads in low rise construction. Key Factors Assessed Mechanical Resistance & Stability Durability serviceability and identification Validity This certificate was first issued on 23 rd July 2010 and is valid until 20 th December 2020 Issue Dated 11 th December 2019 Certificate No: EW35
5
Embed
Precast Ground Beam and Flooring System...Balfour Beatty Ground Engineering Precast Ground Beam System is a ground beam for carrying wall and floor loads in low rise construction.
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Photo/isometric drawing
provided by manufacturer
Precast Ground Beam and Flooring System
Description of Product
Balfour Beatty Ground Engineering Precast
Ground Beam System is a ground beam for
carrying wall and floor loads in low rise
construction.
Key Factors Assessed
Mechanical Resistance & Stability
Durability serviceability and identification
Validity
This certificate was first issued on 23rd July 2010 and is valid until 20th December 2020
Issue Dated 11th December 2019
Certificate No: EW35
This Registered Detail relates to the Balfour Beatty Ground engineering Precast Concrete Ground Beam System, a pre-cast
reinforced concrete ground beam for carrying wall and floor loads between pile caps in all types of traditional. The system is
carried by concrete piles which do not form part of this Registered Detail.
The pile design will be covered separately on a site specific basis
The sulphate resistance of the concrete is equivalent to DC-3. Resistance above this will be dealt with on a site specific basis
Ground heave requirements will be specified on a site specific basis but generally in accordance with the typical heave details
issued
Gas/Contamination protection will be as specified by the client’s engineer on a site specific basis.
For Part E Robust Details a minimum 225mm deep cavity between the top of the foundation beam and the underside of the
floor beam is required.
LABC consider that, Precast Ground Beam System will meet the functional requirements of the Building
Regulations (listed below) if the criteria detailed in this certificate are met;
The Building Regulations 2010 (as amended) England & Wales
Please refer to the individual Regulations below.
The Building Regulations 2010 (as amended) England
Regulation 7 (2018) Materials and workmanship
Note: The system is acceptable.
AD A (2013) Structure
Note: The system meets this Requirement subject to limitations detailed under the
Conditions section.
The Building Regulations 2010 (as amended) Wales
Regulation 7 (2013) Materials and workmanship
Note: The system is acceptable.
AD A Structure
Note: The system meets this Requirement subject to limitations detailed under the
Conditions section.
The Building (Scotland) Regulations 2004 (as amended)
If you would like to discuss a specific use of the product in Scotland it will require an additional
assessment under the Scottish Building Regulations and accordingly you should contact the LABSS