Poor Rx Quality
Poor Rx Quality due to no dominant serving cell in the area.
Recommend to Build a New site. Sector Optimization of ZAN047B;
azimuth change from 220-240 needed to improve coverage.
No Dominant Serving cell
HUAWEI TECHNOLOGIES CO., LTD.
Huawei Confidential
:32-35pt : R153 G0 B0 : FrutigerNext LT Medium : Arial :30-32pt :
R153 G0 B0 : :20-22pt (2-5) :18pt : : FrutigerNext LT Regular :
Arial :18-20pt (2-5):18pt : :
.
Recommendations Summary:
Poor coverage due to cell TNG063E is overshooting, recommend to
down tilt from 0MT to 3MT to avoid overshooting.
Poor Rx Quality due to overshooting of cell TNG117C, recommend to
down tilt from 0MT to 3MT to avoid overshooting.
Overshooting of Cell TNG353D&E; Recommend to down tilt from 0MT
to 3MT.
Drop call due to Adjacent channel interference of TNG334F with
TNG115E having BCCH 577 with BCCH 578. Recommend for freq
retuning.
Drop call due to Adjacent channel interference of BCCH 568 with
BCCH 569_BSIC44. Recommend for freq retuning of TNG116D.
Poor Rx Quality due to no dominant serving cell in the area.
Recommend to Build a New site. Sector Optimization of ZAN047B;
azimuth change from 220-240 needed to improve coverage.