Technology Training that works Technology Training that Works www.idc-online.com/slideshare Practical Troubleshooting & Problem Solving of Ethernet Networks: RS-232 Fundamentals
Jan 14, 2015
Technology Training that worksTechnology Training that Workswww.idc-online.com/slideshare
Practical Troubleshooting & Problem Solving of Ethernet Networks:
RS-232 Fundamentals
Technology Training that worksTechnology Training that Workswww.idc-online.com/slideshare
DTE vs DCE
• DTE– Data Terminal Equipment– Transmits on Pin 2 for 25-pin connector
• DCE– Data Communications Equipment– Transmits on Pin 3 for 25-pin connector
Technology Training that worksTechnology Training that Workswww.idc-online.com/slideshare
RS-232 Connections (DB25)
Technology Training that worksTechnology Training that Workswww.idc-online.com/slideshare
EIA-232
• Electrical Signal levels– Logic 0 =+3 to+25V = Control ON– Logic 1 = -3 to -25V = Control OFF
• Mechanical Interface– DB-25, DB-9 connectors
• Circuit Functionality
Technology Training that worksTechnology Training that Workswww.idc-online.com/slideshare
Voltage Levels for EIA-232
Data Line Driver
Control Line Driver
0 (Space)
1 (On)
1 (Mark)
0 (Off)
Data Lines
Driver Receiver
Control Lines
Data Receiver
Control Receiver
+25 V
+25 V
+25 V
+25 V
-25 V
-25 V
-25 V
-25 V
+5 V
+5 V
+3 V
+3 V
-5 V
-5 V
-3 V
-3 V
0 V
0 V
0 V
0 V
ON
OFF
0
1
Technology Training that worksTechnology Training that Workswww.idc-online.com/slideshare
Pin AssignmentsPin Number
(DTE)DB9 Connector IBM Assignment
DB25 ConnectorEIA-232 Pin Assignment
1 Received Line Signal Shield
2 Received Data Transmitted Data
3 Transmitted Data Received Data
4 DTE Ready Request to Send
5 Signal Common/Ground Clear to Send
6 DCE Ready DCE Ready
7 Request to Send Signal Common/Ground
8 Clear to Send Received Line Signal
9 Ring Indicator + Voltage (Testing)
20 - DTE Ready
22 - Ring Indicator
Technology Training that worksTechnology Training that Workswww.idc-online.com/slideshare
Limitations• Point-to-Point
• Distance Limitation = 2500pf (50ft @ 50pf/ft)
• 20kbps
• -3 to -25V and +3 to +25 V
• Note Table 2.1 Page 30 !
Technology Training that worksTechnology Training that Workswww.idc-online.com/slideshare
Typical Approach
• Check basic Parameters
• Identify which is DTE and DCE
• Clarify handshaking compatibility– either Hardware– or Software
• Check actual protocol– use protocol analyzer
Technology Training that worksTechnology Training that Workswww.idc-online.com/slideshare
Test Equipment
• Multimeter
• LED
• Breakout Box
• PC Based Protocol Analyzer
• Dedicated Protocol Analyzer
Technology Training that worksTechnology Training that Workswww.idc-online.com/slideshare
Breakout Box
LEDs usually Bi-Color
Red commonly Positive Green commonly Negative
DIPSwitches
Common
Technology Training that worksTechnology Training that Workswww.idc-online.com/slideshare
RS-232 Breakout Box
Technology Training that worksTechnology Training that Workswww.idc-online.com/slideshare
Protocol Analyzer Connections
Protocol Analyzer
Technology Training that worksTechnology Training that Workswww.idc-online.com/slideshare
Typical RS-232 Problems
• Mechanical Problems– Keep wires short– Stranded wire instead of solid wire– Only one wire soldered per pin– Bare wire should not be visible– Back shell must secure wire
Technology Training that worksTechnology Training that Workswww.idc-online.com/slideshare
Typical RS-232 Problems
• Setup Problems– Software setup compatible
• 8N1or 7E1 or 7O1
– Baud rate correct– Code correct - Binary/Hex or ASCII– Software set up for handshaking
• Hardware or Software control
Technology Training that worksTechnology Training that Workswww.idc-online.com/slideshare
Typical RS-232 Problems
• Noise Problems
– Ground Induced Noise
– Induced Noise on TX or RX lines
– Induced noise on Control Lines
Technology Training that worksTechnology Training that Workswww.idc-online.com/slideshare
DO YOU WANT TO KNOW MORE?
If you are interested in further training or information, please visit:
http://idc-online.com/slideshare