Top Banner
PPU MODULE www.apixanalytics.com A miniaturized Gas Chromatograph available for the analysis of permanent gases and sulfur compounds. The entire Gas Chromatograpy analytical stream (injection, separation and detection) embedded within a small module designed for easy and Plug & Play use. N₂ / CH₄ / CO₂ / C₂H₄ / C₂H₆ / H₂S PPU
2

PPU MODULE PPU - apixanalytics.com · PPU MODULE A miniaturized Gas Chromatograph available for the analysis of permanent gases and sulfur compounds. The entire Gas Chromatograpy

Sep 21, 2020

Download

Documents

dariahiddleston
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: PPU MODULE PPU - apixanalytics.com · PPU MODULE A miniaturized Gas Chromatograph available for the analysis of permanent gases and sulfur compounds. The entire Gas Chromatograpy

PPU MODULE

www.apixanalytics.com

A miniaturized Gas Chromatograph

available for the analysis of permanent gases and sulfur

compounds.

The entire Gas Chromatograpy analytical stream

(injection, separation and detection) embedded within a small

module designed for easy and Plug & Play use.

N₂ / CH₄ / CO₂ / C₂H₄ / C₂H₆ / H₂S

PP

U

Page 2: PPU MODULE PPU - apixanalytics.com · PPU MODULE A miniaturized Gas Chromatograph available for the analysis of permanent gases and sulfur compounds. The entire Gas Chromatograpy

10 15 20 25 30time (s)

PPU

1

2

A MINIATURIZED AND FAST GC WITHIN A COMPACT, LIGHTWEIGHT, PLUG & PLAY MODULE

RESULTS

[email protected] Polytec - Immeuble Tramontane • 60 rue des Berges 38000 Grenoble

Analysis of N₂ / CH₄ / CO₂ / C₂H₄ / C₂H₆ / H₂SDesigned for Natural Gas and Biomethane Analysis

APPLICATIONS

Stationnary Phase :Divinylbenzene ethylene glycol /dimethylacrylate

Commercial equivalency :Rt®-U-BOND(silice fondue PLOT)HP-PLOT UCP-PoraPLOT UCP PoraBond U

Precolumn, backflush available Loop Volume: 2 or 20µL

TCD DetectorRange : from ppm to %RSD below 0,1% for concentration above 60% and below 1% for lower concentration

Carrier Gas : Injector Temp : Column Temp :Head Column Pressure :

Injection Time : Analysis Time :

1 - Injection2 - H₂S

He80-120°C120°C1,2 bar

500ms24s

He60-80°C70°C0,5-0,7 bar

200ms40s

10 15 20 25 30 35 40time (s)

PPU-10

1

2

3

4

1 - N₂ 2 - CH₄ 3 - CO₂ 4 - C₂H₆

C1-C3

C3-C6

(Incl Isomers)

> C6

Alkenes

Polar Compounds

BTEX, Aromatic Compounds

Permanent Gases (O2, H2, N2)

Sulfur Compounds

H2S