-PPS31M-20190927 Sensor Type Piezo (or Quartz*) / RTD Pressure Range–psi 10K | 15K | 20K Accuracy–psi* ± 0.03% FS Resolution–psi* 0.0003% FS *Quartz transducer offers higher accuracy and resolution Temperature Sensor Type RTD (Pt1000) Range–°C -30 (-22 °F) to 85 (185 °F) Accuracy–°C 0.5 Resolution–°C 0.005 Applications: Gas Wellhead Build-up Tests Stimulation Monitoring Pipeline Monitoring Fracture Monitoring Wellhead Monitoring Injection Pressure Monitoring Perforation Monitoring Pioneer Petrotech Services Inc. © Copyright 2019 Pioneer Petrotech Services Inc. All Rights Reserved. Document ID: MRKT-TS #1, 1431–40 Avenue NE, Calgary, Alberta Canada, T2E 8N6 | Tel: 1–403–282–7669 | Fax: 1–403–282–0509 Toll Free in Canada & US: 1–888–PP–GAUGE (774–2843) | Email: [email protected] Proudly Canadian ISO 9001 Certified PPS31M Multi-Channel Wellhead Pressure Logger The PPS31M Multi-Channel Wellhead Pressure Logger is integrated with up to four channels, one internal (pressure) and three wired externally. The three external channels can be SOI pressure transducers, or RTD temperature probes, in the customer’s preferred configuration. This is a good choice for applications where high data quality is required. The main unit and the other transmitters can be mounted onto the wellhead to measure readings such as: tubing, casing and vent pressures or temperatures. There is also the option to have a wireless radio transmitter and receiver with a transmission distance up to 100m line of sight.
2

PPS31M Multi-Channel Wellhead Pressure Logger · -PPS31M-20190927 Sensor Type Piezo (or Quartz*) / RTD Pressure Range–psi 10K | 15K | 20K Accuracy–psi* ± 0.03% FS Resolution–psi*

Jul 20, 2020

Download

Documents

dariahiddleston
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: PPS31M Multi-Channel Wellhead Pressure Logger · -PPS31M-20190927 Sensor Type Piezo (or Quartz*) / RTD Pressure Range–psi 10K | 15K | 20K Accuracy–psi* ± 0.03% FS Resolution–psi*

-PPS31M-20190927

Sensor Type Piezo (or Quartz*) / RTD

PressureRange–psi 10K | 15K | 20KAccuracy–psi* ± 0.03% FSResolution–psi* 0.0003% FS

*Quartz transducer offers higher accuracy and resolution

TemperatureSensor Type RTD (Pt1000)Range–°C -30 (-22 °F) to 85 (185 °F)Accuracy–°C 0.5Resolution–°C 0.005

Applications:• GasWellheadBuild-upTests• StimulationMonitoring• PipelineMonitoring• FractureMonitoring• WellheadMonitoring• InjectionPressureMonitoring

• PerforationMonitoring

Pioneer Petrotech Services Inc.

© Copyright 2019 Pioneer Petrotech Services Inc. All Rights Reserved. Document ID: MRKT-TS

#1, 1431–40 Avenue NE, Calgary, Alberta Canada, T2E 8N6 | Tel: 1–403–282–7669 | Fax: 1–403–282–0509 Toll Free in Canada & US: 1–888–PP–GAUGE (774–2843) | Email: [email protected]

Proudly Canadian ISO 9001 Certified

PPS31MMulti-ChannelWellheadPressureLoggerThe PPS31M Multi-ChannelWellhead Pressure Logger is integrated with up to four channels, one internal (pressure) and three wired externally. The three external channels can be SOI pressure transducers, or RTD temperature probes, in the customer’s preferred configuration.

This is a good choice for applications where high data quality is required. The main unit and the other transmitters can be mounted onto the wellhead to measure readings such as: tubing, casing and vent pressures or temperatures. There is also the option to have a wireless radio transmitter and receiver with a transmission distance up to 100m line of sight.

Page 2: PPS31M Multi-Channel Wellhead Pressure Logger · -PPS31M-20190927 Sensor Type Piezo (or Quartz*) / RTD Pressure Range–psi 10K | 15K | 20K Accuracy–psi* ± 0.03% FS Resolution–psi*

-PPS31M-20190927© Copyright 2019 Pioneer Petrotech Services Inc. All Rights Reserved. Document ID: MRKT-TS

Pioneer Petrotech Services Inc.Proudly Canadian ISO 9001 Certified

#1, 1431–40 Avenue NE, Calgary, Alberta Canada, T2E 8N6 | Tel: 1–403–282–7669 | Fax: 1–403–282–0509 Toll Free in Canada & US: 1–888–PP–GAUGE (774–2843) | Email: [email protected]

CharacteristicsChannels Up to 4Display AlphanumericMemory Capacity 20,000,000 samplesSensor Channels 4 sensors: One built in, three external wiredExternal Wired Sensors 1.25” OD, ¼” HP Pressure sensors 15K/85C 1.25” OD, ½” NPT Temperature sensor range -30C to 85CAdapter ¼” HP pin to ½” NPT pin adaptor, Inconel 718Service Sour ServicesPower Source Lithium Battery PackData Set Time / Pressure / Temperature / RTDWork Mode SRO / MROSample Rate 1s-18hr/sampleConnection ½” NPT / AutoclaveSafety Rating Class I Division 1 Group A, B, C and D, T4 Ex ia IIC T4 (-40 °C–55 °C)Operating Temperature–°C -30 (-22 °F) to 60 (140 °F)Operating Humidity 5 to 95% Non-Condensing

PPS31MMulti-ChannelWellheadPressureLogger