PPE: Why Fabric Matters Chris Corner Vice President of International Business Development January 12, 2016
33

PPE: Why Fabric Matters - · PDF filePPE: Why Fabric Matters ... Newtons Tested 5 times in warp and fill ... ISO 12947-2 Test Method Simulates extended wear life AS/NZS 4967

Feb 27, 2018

Download

Documents

lamcong
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: PPE: Why Fabric Matters -  · PDF filePPE: Why Fabric Matters ... Newtons Tested 5 times in warp and fill ... ISO 12947-2 Test Method Simulates extended wear life AS/NZS 4967

PPE: Why Fabric Matters

Chr is Corner

Vice Pres ident of Internat ional Bus iness Deve lopment

January 12, 2016

Page 2: PPE: Why Fabric Matters -  · PDF filePPE: Why Fabric Matters ... Newtons Tested 5 times in warp and fill ... ISO 12947-2 Test Method Simulates extended wear life AS/NZS 4967

Agenda TenCate Overview

Inherently Flame Resistant Fibers

How Inherently Flame Resistant Fabrics Are Made Production Process Yarn Types Fabric Structures

International Firefighting Protective Clothing Standards

Outer Shell Fabrics Function Selection Fabric Examples Physical Properties

Questions

Page 3: PPE: Why Fabric Matters -  · PDF filePPE: Why Fabric Matters ... Newtons Tested 5 times in warp and fill ... ISO 12947-2 Test Method Simulates extended wear life AS/NZS 4967

Royal TenCate Corporate Summary

TenCate Snapshot 2014 Sales - $1.25 Billion (USD)

4000+ Employees Worldwide

Key Business Segments: Advanced Composites and Armor

Technical and Protective Fabrics

Geosynthetics and Synthetic Grass

3

Page 4: PPE: Why Fabric Matters -  · PDF filePPE: Why Fabric Matters ... Newtons Tested 5 times in warp and fill ... ISO 12947-2 Test Method Simulates extended wear life AS/NZS 4967

Market Leadership Leading Supplier to the Global Emergency Response Market

70% of US Firefighters wear TenCate Protective Fabrics Products compliant to NFPA, EN, AS/NZ and ISO standards

#1 Supplier of FR fabrics for US Wildland Firefighters US Forest Service and CALFIRE wear TenCate fabrics Protecting firefighters in North America, South America, and Asia Pacific

Leading supplier to the Industrial Safety markets around the world Oil & Gas employees exposed to flash fire hazards on every continent depend on TenCate protective fabrics Electric utility workers exposed to electric arc hazard on every continent depend on TenCate fabrics Provide solutions for welding, chemical splash, molten metal splash & other

#1 Provider of FR fabrics to the US Military U.S. Troops deployed into wartime environment wear TenCate Defender® M Provide solutions for Armies, Navies, Air Forces, Law Enforcement and Special Forces around the world

4

Page 5: PPE: Why Fabric Matters -  · PDF filePPE: Why Fabric Matters ... Newtons Tested 5 times in warp and fill ... ISO 12947-2 Test Method Simulates extended wear life AS/NZS 4967

Emergency Response Inherently Flame Resistant Fiber Comparison

Tensile Strength g/d Limiting Oxygen

Index

Decomposition

Temperature oF/oC

PBO 42 68 1,200/650

PBI 3.1 41 1,200/650

P-Aramid 22 29 800 – 900/425-480

M-Aramid 5.3 29 750/400

5

PBO

Page 6: PPE: Why Fabric Matters -  · PDF filePPE: Why Fabric Matters ... Newtons Tested 5 times in warp and fill ... ISO 12947-2 Test Method Simulates extended wear life AS/NZS 4967

Fabric Production Process

Fiber

Yarn

Weaving

Dye /

Finish

Page 7: PPE: Why Fabric Matters -  · PDF filePPE: Why Fabric Matters ... Newtons Tested 5 times in warp and fill ... ISO 12947-2 Test Method Simulates extended wear life AS/NZS 4967

Types of Yarn

7

Spun Yarn

Filament Yarn

Engineered / Protected Filament Yarn

Spun Yarn

Page 8: PPE: Why Fabric Matters -  · PDF filePPE: Why Fabric Matters ... Newtons Tested 5 times in warp and fill ... ISO 12947-2 Test Method Simulates extended wear life AS/NZS 4967

Different Fabric Structures

Woven Knit Non-woven

Page 9: PPE: Why Fabric Matters -  · PDF filePPE: Why Fabric Matters ... Newtons Tested 5 times in warp and fill ... ISO 12947-2 Test Method Simulates extended wear life AS/NZS 4967

Woven Fabric Structures Plain Weave

Basic Weave Pattern Yarns are square Modified Version

Rip Stop Based On Plain Weave w/ Extra Yarns in the Rips 2 or 3 ends Increases trap tear strength, does not increase tensile strength

Twill Weave Series of diagonal lines, or twill lines Good Flexibility

Page 10: PPE: Why Fabric Matters -  · PDF filePPE: Why Fabric Matters ... Newtons Tested 5 times in warp and fill ... ISO 12947-2 Test Method Simulates extended wear life AS/NZS 4967

International Firefighting Protective Clothing Standards

AS/NZS 4967:2009 - Protective clothing for firefighters - Requirements and test methods for protective clothing used for structural firefighting

NFPA 1971 – 2013 Edition – Standard on protective ensembles for structural firefighting and proximity firefighting.

EN 469:2005 – Protective clothing for firefighters – Performance requirements for protective clothing for firefighting.

ISO 11613-1999 – Protective clothing for firefighting – Laboratory test methods and performance requirements.

Page 11: PPE: Why Fabric Matters -  · PDF filePPE: Why Fabric Matters ... Newtons Tested 5 times in warp and fill ... ISO 12947-2 Test Method Simulates extended wear life AS/NZS 4967

Typical Gear Construction

Three Layer System Outer Shell

Moisture Barrier

Thermal Barrier

Page 12: PPE: Why Fabric Matters -  · PDF filePPE: Why Fabric Matters ... Newtons Tested 5 times in warp and fill ... ISO 12947-2 Test Method Simulates extended wear life AS/NZS 4967

What is the Function of the Outershell?

Provides tough, durable first line of defense against heat, flame and abrasion

Protects the moisture barrier and thermal barrier

Offers resistance to rips, cuts, and tears

Allows garment to shed water

Typically made from woven fabrics

A broad range of choices

Page 13: PPE: Why Fabric Matters -  · PDF filePPE: Why Fabric Matters ... Newtons Tested 5 times in warp and fill ... ISO 12947-2 Test Method Simulates extended wear life AS/NZS 4967

Choosing the Right Outer Shell for You

Page 14: PPE: Why Fabric Matters -  · PDF filePPE: Why Fabric Matters ... Newtons Tested 5 times in warp and fill ... ISO 12947-2 Test Method Simulates extended wear life AS/NZS 4967

TenCate Outer Shells

Page 15: PPE: Why Fabric Matters -  · PDF filePPE: Why Fabric Matters ... Newtons Tested 5 times in warp and fill ... ISO 12947-2 Test Method Simulates extended wear life AS/NZS 4967

100% Nomex® IIIA 7.5 oz/yd2 or 255 g/m2

Plain Weave Shelltite™ Multiple Colors Economical

100% Nomex® IIIA 6.0 oz/yd2 or 205 g/m2

Ripstop Weave Shelltite™, Super Shelltite™, EN 469 DWR Multiple Colors Economical Lightweight

Page 16: PPE: Why Fabric Matters -  · PDF filePPE: Why Fabric Matters ... Newtons Tested 5 times in warp and fill ... ISO 12947-2 Test Method Simulates extended wear life AS/NZS 4967

60% Kevlar® / 40% Nomex® 7.2 oz/yd2 or 245 g/m2

Ripstop Weave Super Shelltite™, EN 469 DWR Black, Navy, Gold, Yellow, & Khaki Good value Good durability

Page 17: PPE: Why Fabric Matters -  · PDF filePPE: Why Fabric Matters ... Newtons Tested 5 times in warp and fill ... ISO 12947-2 Test Method Simulates extended wear life AS/NZS 4967

58% Para-aramid / 39% PBI/3% Antistat

6.0 oz/yd2 or 205 g/m2

Modified Plain Weave

Reinforced with a high-strength filament grid

Super Shelltite™, EN 469 DWR, AS 4967 DWR

Natural, Black, Dark Navy

No puckering after laundering

Light weight without compromising durability

Page 18: PPE: Why Fabric Matters -  · PDF filePPE: Why Fabric Matters ... Newtons Tested 5 times in warp and fill ... ISO 12947-2 Test Method Simulates extended wear life AS/NZS 4967

60% Kevlar® / 40% PBI

7.5 oz/yd2 or 255 g/m2

Modified Plain Weave

Reinforced with a high-strength filament grid

Super Shelltite™

Natural, Black

Strong & flexible after thermal exposure

Now softer & more flexible

Page 19: PPE: Why Fabric Matters -  · PDF filePPE: Why Fabric Matters ... Newtons Tested 5 times in warp and fill ... ISO 12947-2 Test Method Simulates extended wear life AS/NZS 4967

60% Technora® / 40% PBO

7.5 oz/yd2 or 255 g/m2

Ripstop Weave

Super Shelltite™

Natural

Strong & flexible after thermal exposure

Excellent strength and durability

Page 20: PPE: Why Fabric Matters -  · PDF filePPE: Why Fabric Matters ... Newtons Tested 5 times in warp and fill ... ISO 12947-2 Test Method Simulates extended wear life AS/NZS 4967

27% Nomex® /73% Kevlar®

6.6 oz./yd. or 225 g/m2

Twill Weave

Enhanced strength using in a lighter weight outer shell

Uses 0% Kevlar Filament

Enhanced comfort with extraordinary flexibility

Super Shelltite™, EN 469 DWR

Page 21: PPE: Why Fabric Matters -  · PDF filePPE: Why Fabric Matters ... Newtons Tested 5 times in warp and fill ... ISO 12947-2 Test Method Simulates extended wear life AS/NZS 4967

Outer Shell Requirements

Physical Hazards (Performance Requirements – The Risk Assessment)

Tensile Strength

Tear Strength

Abrasion – Fabric Thinning Taber

Martindale

Ultra Violet Light

21

Page 22: PPE: Why Fabric Matters -  · PDF filePPE: Why Fabric Matters ... Newtons Tested 5 times in warp and fill ... ISO 12947-2 Test Method Simulates extended wear life AS/NZS 4967

Tensile Strength Test

22

Page 23: PPE: Why Fabric Matters -  · PDF filePPE: Why Fabric Matters ... Newtons Tested 5 times in warp and fill ... ISO 12947-2 Test Method Simulates extended wear life AS/NZS 4967

Tensile Strength – Initial

0

500

1000

1500

2000

2500

3000

Brigade 600 RS Advance™ Gemini XTL Gemini™ XT Millenia™ XT Pioneer

New

ton

s

Warp

Fill

23

NFPA 1971 Standard:

140lbs ≈ 625 N

ASTM 5034

Page 24: PPE: Why Fabric Matters -  · PDF filePPE: Why Fabric Matters ... Newtons Tested 5 times in warp and fill ... ISO 12947-2 Test Method Simulates extended wear life AS/NZS 4967

Trapezoid Tear Strength ASTM 5587 Fabric begins with a small cut

Large clamps are placed along two lines in the shape of a trapezoid

As the fabric is torn, the machine measures the average of five “displacements” or tears

Results are pounds of force or Newtons

Tested 5 times in warp and fill direction. Average of each reported.

Page 25: PPE: Why Fabric Matters -  · PDF filePPE: Why Fabric Matters ... Newtons Tested 5 times in warp and fill ... ISO 12947-2 Test Method Simulates extended wear life AS/NZS 4967

Trap Tear Strength – Initial

0

50

100

150

200

250

300

350

400

Brigade 600 RS Advance Gemini XTL Gemini XT Millenia XT Pioneer

New

ton

s

Warp

Filling

25

NFPA 1971 Standard:

22 lbs ≈ 100 N

ASTM 5587

Page 26: PPE: Why Fabric Matters -  · PDF filePPE: Why Fabric Matters ... Newtons Tested 5 times in warp and fill ... ISO 12947-2 Test Method Simulates extended wear life AS/NZS 4967

Taber Abrasion Testing Taber Abrasion Testing

Fabric disc secured and rotates while weighted heads abrades against fabric surface Calibrated testing machine counts total number of cycles completed before perforations in fabric appear Simulates extended wear

ASTM D3884 Test from American Society for Testing and Materials (ASTM) International

Page 27: PPE: Why Fabric Matters -  · PDF filePPE: Why Fabric Matters ... Newtons Tested 5 times in warp and fill ... ISO 12947-2 Test Method Simulates extended wear life AS/NZS 4967

Millenia™ XT 5500 cycles

Advance™ 3500 cycles

Gemini™ XT 4000 cycles

Pioneer™ 3000 cycles

Page 28: PPE: Why Fabric Matters -  · PDF filePPE: Why Fabric Matters ... Newtons Tested 5 times in warp and fill ... ISO 12947-2 Test Method Simulates extended wear life AS/NZS 4967

Martindale Abrasion Test ISO 12947-2 Test Method

Simulates extended wear life

AS/NZS 4967 ≥ 20,000 Cycles

12 kPa

Crossbred worsted abradant

TenCate Gemini™ XTL ≈ 50,000 Cycles

28

Page 29: PPE: Why Fabric Matters -  · PDF filePPE: Why Fabric Matters ... Newtons Tested 5 times in warp and fill ... ISO 12947-2 Test Method Simulates extended wear life AS/NZS 4967

Ultra Violet Light Exposure

29

UV Light Affects the Physical Properties of all Fibers and Fabrics

Page 30: PPE: Why Fabric Matters -  · PDF filePPE: Why Fabric Matters ... Newtons Tested 5 times in warp and fill ... ISO 12947-2 Test Method Simulates extended wear life AS/NZS 4967

Thermal Protective Performance (TPP)

Measure of thermal insulation

Composite test Outer shell, moisture barrier, thermal barrier

Conditions Heat Flux - 2 cal/cm²·s (84 kW/m²·s)

50/50 Balance Radiant & Convective Energy

NFPA Minimum 35 cal/cm2 - 17.5 Seconds of Protection in flashover conditions

5-8% Variance

30

Page 31: PPE: Why Fabric Matters -  · PDF filePPE: Why Fabric Matters ... Newtons Tested 5 times in warp and fill ... ISO 12947-2 Test Method Simulates extended wear life AS/NZS 4967
Page 32: PPE: Why Fabric Matters -  · PDF filePPE: Why Fabric Matters ... Newtons Tested 5 times in warp and fill ... ISO 12947-2 Test Method Simulates extended wear life AS/NZS 4967

Tensile Strength – After 17.5 Second TPP Exposure

0

100

200

300

400

500

600

700

800

900

Brigade 600 RS Advance Gemini XTL Gemini XT Millenia XT Pioneer

New

ton

s

Warp

Filling

32

Page 33: PPE: Why Fabric Matters -  · PDF filePPE: Why Fabric Matters ... Newtons Tested 5 times in warp and fill ... ISO 12947-2 Test Method Simulates extended wear life AS/NZS 4967

Fabric Matters Because Protecting Firefighters

Matters THANK YOU!