AUSTRALIA AUSTRALIA PowerUps UPS PowerUps UPS HIP3300 Series HIP3300 Series 3Phase/3Phase series
1. Summary
2. Appearance
3. Display
4. Principle
5. Supplement
6. Communication
7. Specification
Catalog
Mission critical & industrial applications
Operator Centres, Servers, Computer rooms, Telecom Switchgear & Infrastructures, Processing Control Equipments, Security Systems, Emergency Lighting, Fire Protection, Airport Infrastructure, Bank, Hospital, Healthcare Equipment …
Main Features
Digital Signal Processor Control and PFC technology Wide Input Voltage and Frequency Windows Compatible with generator Zero transfer time Output Power Factor at 0.9 or 0.8 (optional) Sinusoidal input current THDI ≤ 2% High efficiency can reach up to 95% Superior MTBF(> 200,000 hrs)and MTTR ( <30 min.) ECO mode for energy saving
Main Features
Optional Battery Voltage from ± 192Vdc to ± 240Vdc Intelligent with three stages charging Modes Adjustable charging current Battery Temperature Compensation Advanced battery management Matching internal Battery also Available
Main Features
Smart Fan Speed Control Both EPO and REPO (Remote EPO) Functions Parallel Redundancy up to 4 Units Common or Separate Battery pack in parallel system Reliable protection function Easy-to-operate LCD display Megatec/Modbus Protocol Versatile Communication Interfaces
Power module Qty per unit
10-20K 30K 40K 60K 80K 100K
PF0.8 1 1 2 2 3 4
PF0.9 1 2 2 3 3 4
120K 160K 200K 250K 300K 400K 500K
PF0.8 4 6 5 7 8 10 13
PF0.9 5 6 5 7 8 10 13
Dimension and weightModel Dimension (W*D*H) Weight (kg)10KVA (S/H) 600×780×1200 591(S)/123(H)
15KVA (S/H) 600×780×1200 594(S)/126(H)
20KVA (S/H) 600×780×1200 595(S)/127(H)
30KVA (S/H) 600×780×1200 595(S)/127(H)
40KVA 600×780×1200 158
60KVA 600×780×1200 158
80KVA 600×780×1200 195
100KVA 600×780×1600 286
120KVA 600×780×1600 286
160KVA 600×780×1600 348
200KVA 600×850×1600 380
250KVA 600×850×2000 541
300KVA 600×850×2000 575
400KVA 1200×850×2000 900
500KVA 1200×850×2000 1005
1. Applications
2. Appearance
3. Display
4. Principle
5. Supplement
6. Communication
7. Specification
LCD Display ( 10-80K ) Operational status and mode
Input/output Voltage/Frequency
Battery Voltage/Current
Load capacity
Charge Modes/Charger Status
Internal/Ambient Temperature
Software version & model
Alarm Codes
Rich settings ( 10-80K) Mode setting Output voltage and frequency setting Bypass voltage upper/lower limit setting
Display
Rich settings (10-80K) Parallel ID/quantity/redundancy quantity setting
Battery capacity/quantity setting
System block diagram
EMI PFC
LCD
BATTERY
BYPASS
BUS INVERTER EMI
AUX POWER
CHARGER
COMMUNICATION
DSP
PARALLELBOARD
I/P O/P
Working mode
√ Normal mode√ Battery mode (Stored Energy Mode)√ Bypass mode√ Maintenance mode (Manual Bypass)√ ECO Mode√ Parallel redundancy mode (system expansion)
Supplement
Powerful Charger
Model 10-30k
40-60k 80k 100k 120k 160k 200k 250k 300k 400k 500k
Max charge current
5.7/6A 12A 18A 24A 30A 36A 50A 70A 80A 100A 130
A
Protection type (breaker in bypass mode)
Model 10k 15k 20k 30k 40k 60k 80k
Breaker 20A 32A 40A 50A 80A 100A 125A
Model 100-120k 160k 200k 250-300k 400-500k
Breaker 225A 250A 400A 500A 800A
De-rating Operation Available Normal operation Temperature 0~40 C Max. operation Temperature 50 C De-rating operation: 10% per 5 C
Battery Temperature Compensation Auto-adjusted without any human involvement Compensate from 20 C: Reduce 0.001V*6 of floating voltage per 1 C. 0.002~0.006V * 6 per 1 C settable
Battery Voltage Configurable ±192V\±204V\±216V\±228V\±240Vdc Configurable Selection of the most suitable battery qty & capacity Decrease Initial Investment
3-Stage Intelligent Charging Modes
Constant Current Constant Voltage Floating (Boost Charge 2.30V to 2.35V per cell &Float Charge 2.20V
to 2.29V per cell)
Versatile Communication Interfaces
RS485 Ports RS232 Port USB port (for 100-500k) Parallel Port Dry contact SNMP slot