® The Intel logo and Intel are trademarks or registered trademarks of Intel Corporation or its subsidiaries in the United states and other countries. *Other names and brands are the property of others. PT Power Technologies PT Power Technologies Enterprise Platform Power Enterprise Platform Power Efficiency for Future Server Efficiency for Future Server Systems Systems Tomm Aldridge Manager – Enterprise Power & Thermal Technology Labs Intel Corporation
19

Power Technologies Enterprise Platform Power Efficiency for … · 2008-02-29 · Ride-Thru. AC Out or DC Out. BLDG PWR Input ... use of space, power & cooling Policy based management

Jul 19, 2020

Download

Documents

dariahiddleston
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Power Technologies Enterprise Platform Power Efficiency for … · 2008-02-29 · Ride-Thru. AC Out or DC Out. BLDG PWR Input ... use of space, power & cooling Policy based management

®

The Intel logo and Intel are trademarks or registered trademarks of Intel Corporation or its subsidiaries in the United states and other countries. *Other names and brands are the property of others.

PTPower TechnologiesPT

Power Technologies

Enterprise Platform Power Enterprise Platform Power Efficiency for Future Server Efficiency for Future Server SystemsSystems

Tomm AldridgeManager – Enterprise Power & Thermal

Technology LabsIntel Corporation

Page 2: Power Technologies Enterprise Platform Power Efficiency for … · 2008-02-29 · Ride-Thru. AC Out or DC Out. BLDG PWR Input ... use of space, power & cooling Policy based management

® The Intel logo and Intel are trademarks or registered trademarks of Intel Corporation or its subsidiaries in the United states and other countries. *Other names and brands are the property of others.

PTPower TechnologiesPT

Power Technologies

AgendaAgenda

Current state of the technology for platform power systemsPower architecture (example), main component blocks, etc.in-efficiencies in platform power systems.Possible next directions in power system architecturesCall to action

Page 3: Power Technologies Enterprise Platform Power Efficiency for … · 2008-02-29 · Ride-Thru. AC Out or DC Out. BLDG PWR Input ... use of space, power & cooling Policy based management

® The Intel logo and Intel are trademarks or registered trademarks of Intel Corporation or its subsidiaries in the United states and other countries. *Other names and brands are the property of others.

PTPower TechnologiesPT

Power TechnologiesServer Power EcosystemServer Power EcosystemPDS – Power Delivery System: From wall to device

Raw Power Generation and Bulk Delivery

Delivered

to Building

BLDGPWRInput

PDS

To Rack Servers

And to the device

UPS

To Data Center

Page 4: Power Technologies Enterprise Platform Power Efficiency for … · 2008-02-29 · Ride-Thru. AC Out or DC Out. BLDG PWR Input ... use of space, power & cooling Policy based management

® The Intel logo and Intel are trademarks or registered trademarks of Intel Corporation or its subsidiaries in the United states and other countries. *Other names and brands are the property of others.

PTPower TechnologiesPT

Power Technologies

Typical Data Center Power System Typical Data Center Power System ArchitectureArchitecture

Power Delivery System (PDS) Today

Out

Internal Drive

HDD

PCI I/O

Memory Controller

Processor

SDRAM

Graphics Controller

DC/DCAC/DC

DC/DC

PSU

5V

12V

12V, 5V, -5V, 3.3V

12V

1.5/2.5V

0.9-1.3

3.3V

3.3V

Bridge ChipDC/DC 1.5-many

Fans, Baseboard Mangement, etc.

12V/5V/standby

Multi-outputDC/DC

Switcher

Server

BLDGPWRInput Inverter

Bypass

Battery/ChargerRectifier UPS

PDU

Page 5: Power Technologies Enterprise Platform Power Efficiency for … · 2008-02-29 · Ride-Thru. AC Out or DC Out. BLDG PWR Input ... use of space, power & cooling Policy based management

® The Intel logo and Intel are trademarks or registered trademarks of Intel Corporation or its subsidiaries in the United states and other countries. *Other names and brands are the property of others.

PTPower TechnologiesPT

Power Technologies

UPS TechnologyUPS TechnologyUPS – un-interruptible power supply– Either in series or parallel with mains.– Highly efficient (>88%).– Stand Alone Technology

UPS ExampleUPS Example UPS EFF’Y RANGE

Inverter

In Out

Bypass

Battery/ChargerRectifier

Page 6: Power Technologies Enterprise Platform Power Efficiency for … · 2008-02-29 · Ride-Thru. AC Out or DC Out. BLDG PWR Input ... use of space, power & cooling Policy based management

® The Intel logo and Intel are trademarks or registered trademarks of Intel Corporation or its subsidiaries in the United states and other countries. *Other names and brands are the property of others.

PTPower TechnologiesPT

Power Technologies

PSUPSUAC/DC– Contains Filter/PFC/Bridge/Boost/Conversion to

DC voltages – 3.3/5/12/standby.– Typically low efficiency – 65-80%

90V to 264VAC

5V standby

Post reg.

Post reg.

Post reg.

Post reg.

-12V

3.3V

5V

12V

EMI

FILTER

PFC

circuit

DC/DC

converter

DC/DC

converter

Page 7: Power Technologies Enterprise Platform Power Efficiency for … · 2008-02-29 · Ride-Thru. AC Out or DC Out. BLDG PWR Input ... use of space, power & cooling Policy based management

® The Intel logo and Intel are trademarks or registered trademarks of Intel Corporation or its subsidiaries in the United states and other countries. *Other names and brands are the property of others.

PTPower TechnologiesPT

Power Technologies

PSU Efficiency ConcernsPSU Efficiency Concerns450W Efficiency vs Load

50%

55%

60%

65%

70%

75%

80%

10% 30% 50% 70% 90%

Output Power of Max power(450W)

Efficiency

90Vin

246Vin

Server Mean PowerServer Mean Power•• ““Quality” multi output Quality” multi output server PSserver PS

•• 77% Max efficiency77% Max efficiency

•• Server loads highly Server loads highly variablevariable

•• Mean power ~ 40% of Mean power ~ 40% of ratedrated

•• ½ time below puts us ½ time below puts us in “DANGER ZONE”in “DANGER ZONE”

•• New Power New Power Management Management Techniques ComingTechniques Coming

••Lowers Mean!Lowers Mean!

Page 8: Power Technologies Enterprise Platform Power Efficiency for … · 2008-02-29 · Ride-Thru. AC Out or DC Out. BLDG PWR Input ... use of space, power & cooling Policy based management

® The Intel logo and Intel are trademarks or registered trademarks of Intel Corporation or its subsidiaries in the United states and other countries. *Other names and brands are the property of others.

PTPower TechnologiesPT

Power Technologies

VRD’s/VRM’sVRD’s/VRM’sDC/DC– Typically good efficiency 75-88%

Could go to 90% at today’s levels– Buck topologies typically & small– Lots of Efficiency Optimization in Place

#1

#2

#3

#4

SequentialLogic

CONTROLLER

L1

C BULK

R SV OUT

L2

L3

L4

Page 9: Power Technologies Enterprise Platform Power Efficiency for … · 2008-02-29 · Ride-Thru. AC Out or DC Out. BLDG PWR Input ... use of space, power & cooling Policy based management

® The Intel logo and Intel are trademarks or registered trademarks of Intel Corporation or its subsidiaries in the United states and other countries. *Other names and brands are the property of others.

PTPower TechnologiesPT

Power Technologies

Efficiency Efficiency StackupStackup

Page 10: Power Technologies Enterprise Platform Power Efficiency for … · 2008-02-29 · Ride-Thru. AC Out or DC Out. BLDG PWR Input ... use of space, power & cooling Policy based management

® The Intel logo and Intel are trademarks or registered trademarks of Intel Corporation or its subsidiaries in the United states and other countries. *Other names and brands are the property of others.

PTPower TechnologiesPT

Power Technologies

Server System Power ConsumptionServer System Power Consumption

#1 Power User is the Power System Conversion Loss (36%)

Page 11: Power Technologies Enterprise Platform Power Efficiency for … · 2008-02-29 · Ride-Thru. AC Out or DC Out. BLDG PWR Input ... use of space, power & cooling Policy based management

® The Intel logo and Intel are trademarks or registered trademarks of Intel Corporation or its subsidiaries in the United states and other countries. *Other names and brands are the property of others.

PTPower TechnologiesPT

Power Technologies

Where the power goes…Where the power goes…

PDU/UPS 95WPDU/UPS 95W

PSU 195WPSU 195W

VR’s 90WVR’s 90W

Load 360WLoad 360W740W Input

Only ~½ input power goes to load

Page 12: Power Technologies Enterprise Platform Power Efficiency for … · 2008-02-29 · Ride-Thru. AC Out or DC Out. BLDG PWR Input ... use of space, power & cooling Policy based management

® The Intel logo and Intel are trademarks or registered trademarks of Intel Corporation or its subsidiaries in the United states and other countries. *Other names and brands are the property of others.

PTPower TechnologiesPT

Power TechnologiesPossible Next Directions…Possible Next Directions…New Power System Architecture– Segmentation– Scalable / POL Active Regulators (POLAR)

Out

EMI/Filter- PFC

Memory

AC/DC

Thermal Mangement,

etc.

Server

Inverter

Bypass

Battery/ChargerRectifier

PDU/UPS

400VDC –12VDCPOLAR

400VDC –12VDCPOLAR

400VDC –12VDCPOLAR

Memory Cntl

uP(2), MC, Bridge

I/O

HDD’s

Internal Drive

Server Mang.

Int. Cntl

Bulk CapRide-Thru

AC Out or DC Out

BLDGPWRInput

Page 13: Power Technologies Enterprise Platform Power Efficiency for … · 2008-02-29 · Ride-Thru. AC Out or DC Out. BLDG PWR Input ... use of space, power & cooling Policy based management

® The Intel logo and Intel are trademarks or registered trademarks of Intel Corporation or its subsidiaries in the United states and other countries. *Other names and brands are the property of others.

PTPower TechnologiesPT

Power Technologies

Some Ingredients: Server PS Some Ingredients: Server PS ArchitecturesArchitectures

Segmentation and Distribution Example

POLAR

POLAR

POLAR

DC OutHV DC

In

ServerServer PCB Mounted

AC Input

Full-BridgeRectifier

EMIFilter

PFC + Boost

EMIFilter

Rack or ServerRack or Server

••Input Filter Input Filter –– PFC PFC –– Boost Boost -- BridgeBridge••Separate box for Filter in Separate box for Filter in serverserver••PFC & Boost may be in rack PFC & Boost may be in rack for scalabilityfor scalability

Page 14: Power Technologies Enterprise Platform Power Efficiency for … · 2008-02-29 · Ride-Thru. AC Out or DC Out. BLDG PWR Input ... use of space, power & cooling Policy based management

® The Intel logo and Intel are trademarks or registered trademarks of Intel Corporation or its subsidiaries in the United states and other countries. *Other names and brands are the property of others.

PTPower TechnologiesPT

Power TechnologiesSome Ingredients: Some Ingredients: POLAR’sPOLAR’s

Polars (Point of Load Active Regulators)– Conversion Module – Higher Voltage DC in / Lower

Voltage DC outParallelable, external control, simple, scalable, highly efficient

POLAR in ServerPOLAR Module

Page 15: Power Technologies Enterprise Platform Power Efficiency for … · 2008-02-29 · Ride-Thru. AC Out or DC Out. BLDG PWR Input ... use of space, power & cooling Policy based management

® The Intel logo and Intel are trademarks or registered trademarks of Intel Corporation or its subsidiaries in the United states and other countries. *Other names and brands are the property of others.

PTPower TechnologiesPT

Power Technologies

Improve energy efficiency

Some Ingredients: Demand Based SwitchingSome Ingredients: Demand Based SwitchingPrinciple– Optimize processor

performance (speed) UtilizationAllocation/Budget

Ingredients– Processor P states– OS directed changes

HaltHalt

Idle

4 GHz4 GHz1.39V1.39V103W103W

3.6 GHz3.6 GHz1.33V1.33V89W89W

3.2 GHz3.2 GHz1.27V1.27V77W77W

2.8 GHz2.8 GHz1.2 V1.2 V65W65W

High LowUtilization

HypotheticalHypotheticalNumbers Numbers

Modulate Performance/PowerOperating Point of Processor

Modulate Performance/PowerOperating Point of Processor

Page 16: Power Technologies Enterprise Platform Power Efficiency for … · 2008-02-29 · Ride-Thru. AC Out or DC Out. BLDG PWR Input ... use of space, power & cooling Policy based management

® The Intel logo and Intel are trademarks or registered trademarks of Intel Corporation or its subsidiaries in the United states and other countries. *Other names and brands are the property of others.

PTPower TechnologiesPT

Power TechnologiesWhat about Server Utilization What about Server Utilization Effects??Effects??

Power is under utilized – in some cases, less than 50% of power in server may be used.

A day in Exchange Workload

0102030405060708090

100

0%

20%

40%

60%

80%

100%

120%

CPU 1 CPU 2 AC Power AC PowerWith DBS

Processor utilization indicates how busy a server is.

Processor utilization with DBS indicates load power is also low.

Page 17: Power Technologies Enterprise Platform Power Efficiency for … · 2008-02-29 · Ride-Thru. AC Out or DC Out. BLDG PWR Input ... use of space, power & cooling Policy based management

® The Intel logo and Intel are trademarks or registered trademarks of Intel Corporation or its subsidiaries in the United states and other countries. *Other names and brands are the property of others.

PTPower TechnologiesPT

Power Technologies

Rack power & cooling

AdministrativePolicy System Usage

Workload Predictor

Utility Power,Backup Power

Some Ingredients: Enterprise Power & Some Ingredients: Enterprise Power & Thermal ManagerThermal Manager

Policy based management maximizesuse of space, power & cooling

Policy based management maximizesuse of space, power & cooling

(Hotspots)Thermocouples

Cooling systems

EPTMEPTMEnterprise PowerEnterprise Power

and Thermal Managerand Thermal Manager

Page 18: Power Technologies Enterprise Platform Power Efficiency for … · 2008-02-29 · Ride-Thru. AC Out or DC Out. BLDG PWR Input ... use of space, power & cooling Policy based management

® The Intel logo and Intel are trademarks or registered trademarks of Intel Corporation or its subsidiaries in the United states and other countries. *Other names and brands are the property of others.

PTPower TechnologiesPT

Power TechnologiesAnswers to the Challenge

Call to Action: Server PowerCall to Action: Server PowerIncrease overall PDS efficiency above 75% in all platform systemsRe-vamp server level PS architecture for size, efficiency, and costPSU needs overhaul for server systems– Make PSU synergistic with server system requirements and

power system architectureUse DBS – demand based switching – to minimize overall power in system VR’s could to maintain cost structure and increase in density.UPS/PDU’s could to increase in efficiency to be above 90% - combined.

IntelLabs

Page 19: Power Technologies Enterprise Platform Power Efficiency for … · 2008-02-29 · Ride-Thru. AC Out or DC Out. BLDG PWR Input ... use of space, power & cooling Policy based management

® The Intel logo and Intel are trademarks or registered trademarks of Intel Corporation or its subsidiaries in the United states and other countries. *Other names and brands are the property of others.

PTPower TechnologiesPT

Power Technologies

Questions?Questions?

ContactsContactsPTTL– [email protected]