Top Banner
By Pavan Mulani Kamal Singh Viranchi Kumar Mishra Chandra Prakash Prashant Makwana Samir Sarvadi Jawahar K GET-APL
16

Power Former 2003

Apr 08, 2015

Download

Documents

pravar_jain
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Power Former 2003

ByPavan Mulani

Kamal SinghViranchi Kumar Mishra

Chandra PrakashPrashant Makwana

Samir SarvadiJawahar K

GET-APL

Page 2: Power Former 2003

Objective

To introduce a new device to provide direct connection to the high-voltage power grid without using a step-up transformer.

04/11/23 2Powerformer

Page 3: Power Former 2003

Contents Introduction Construction Cable construction Cooling system Fault current behavior Merits and demerits Conclusion

04/11/23 3Powerformer

Page 4: Power Former 2003

What is powerformer ?

Powerformer is same as generator but only difference in construction.

GeneratorTransform

erPowerforme

r

04/11/23 4Powerformer

Page 5: Power Former 2003

Conventional Vs. Powerformer

Conventional system

System with Powerformer

1. Generator2. Generator

Circuit breaker3. Surge arrestor4. Transformer5. Circuit breaker

04/11/23 5Powerformer

Page 6: Power Former 2003

ConstructionPowerformer Conventional

Stator winding:

1.High voltage cable 2.XLPE insulation3.Only Cylindrical winding

Stator winding:

1. Copper bars2. Paper insulation3. Rectangular

Rotor winding is same in both the systems

04/11/23 6Powerformer

Page 7: Power Former 2003

04/11/23 Powerformer 7

Page 8: Power Former 2003

Cable Construction

1) Conductor2) Inner semi conductor layer3) XLPE insulation4) Outer semi conducting layer04/11/23 8Powerformer

Page 9: Power Former 2003

Nature of electric field

04/11/23 9Powerformer

Page 10: Power Former 2003

Cooling system

Cooling done at zero potential Tap water can be usedXLPE pipes used axiallyNo radial ductLess risk of short circuit

04/11/23 10Powerformer

Page 11: Power Former 2003

Fault current behavior

04/11/23 11Powerformer

Page 12: Power Former 2003

04/11/23 12Powerformer

Page 13: Power Former 2003

Currently used

04/11/23 13Powerformer

Page 14: Power Former 2003

MeritsHigh efficiencyLow lossMore reliableLow environment impact

Demerits Occupies Large volume More expensive

04/11/23 14Powerformer

Page 15: Power Former 2003

Conclusion

Direct connection to power grid without using transformer

Can generate power upto 220 kVSlot size decreases due to less insulationEconomical, reliable and more efficientvery clean and compact power plant

04/11/23 15Powerformer

Page 16: Power Former 2003

Thank you

04/11/23 16Powerformer