Top Banner
Power Control Company USA, LLC A “Green” Solution to Power Factor Correction and Harmonic Distortion
19
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Power control investor

Power Control Company USA, LLC

A “Green” Solution to Power Factor Correction and Harmonic Distortion

Page 2: Power control investor

Statement of Purpose

The Power Control Filter System corrects power factor error, eliminates all damaging harmonics, stabilizes voltage fluctuations, protects against sag and spike damage.

These problems are the largest cause of power waste, damage to electronics and electrical equipment and costs facing the commercial consumer of electricity today.

Page 3: Power control investor

Introducing

This product is the holder of several design and application patents

The Power Control Filter SystemThe only power system that addresses ALL aspects of power usage issues

Page 4: Power control investor

What Problems Do Power Control Filters Solve

Electronics and Electrical Gear run best with perfect waves of electricity– Utility power is often inconsistent– Equipment can only use 60 cycle current– Your equipment becomes inefficient and is

damaged by “dirty power”

Page 5: Power control investor

Power Factor

Power Factor– Most businesses are running on around 70% or

less Power Factor. This means you are paying for 30% or more unusable

delivered power.

– Yet you pay for all 100% of delivered power.

Is this a power company problem?

NO, because YOU are paying the bills.

Page 6: Power control investor

Harmonic Distortion

Another product of the proliferation of business equipment and devices is “Harmonic Distortion”

Harmonic distortion occurs when any electrical frequency is outside 60 hz. It is created by multiple devices in an environment

Page 7: Power control investor

Eliminates Harmonic Distortion

Active Harmonic Filter - The PCC Active Harmonic Filter is an intelligent system which monitors all harmonics from the 60 Hz prime frequency to 100,000 Hz. It is a fourteen section heavy electronic device which identifies all frequencies in that range and opposes that frequency with an equal and opposite signal to kill the distortion and return it to zero voltage and zero amperage. The speed of which this broadband filter reacts is 71 nanoseconds and can correct between 5 to 160 Amps of harmonic distortion.

Page 8: Power control investor

How Does it Work?

The Power Control unit is a unique blend of custom built transformers, capacitors and software that smooth the incoming power.

Sophisticated algorithms then actively and intelligently counter balance the harmonic distortion created by down stream equipment

Each unit is custom “tuned” to the installation

Page 9: Power control investor

Benefits of Power Control Filters

Saving 15% to 30% on Your Power Bills Devices Run Cooler and Last Longer

– Computers & Electronic devices– Electric motors – no rewinding– Lighting – significantly reduces the need to re-bulb– Transformers – longer life– Heavy Industrial Equipment– Sensitive Medical Devices and Equipment – prevents

damage Avoiding Mission Critical Data Problems Reducing HVAC usage

Page 10: Power control investor

Do Power Control Filters Work?

ABSOLUTELY Installed at

– US Army Intelligence Data Center (Utah) Power Factor went from 68% to 94% Saving Thousands a Month Loss of Potentially Critical Data was Eliminated

– Nellson Pharmaceutical Electric Motors that Ran Hot requiring replacement every 2

months began to run cool, no replacements in a year

– Hundreds of successful installations in a variety of industries including; hospitals, manufacturing and communications.

Page 11: Power control investor

The Market

Hospitals Labs Manufacturing Facilities College & Universities Office and Residential Buildings Malls Warehouses Printing Plants

Page 12: Power control investor

Manufacturing

The unit is a relatively simple product to assemble. A company with a good “mod” shop can build this product.

There 2 basic units. These units are then custom tuned to the application.

An average installation will be 5 – 15 units.

Page 13: Power control investor

Unit Cost, Selling Price, ROI (USD)

A single unit cost is $6-7,000 dollars An average installed unit cost is $20 – 40,000 Average Facility Sale $120k – 1.2 million Average Facility Return on Investment 9-12

Months There is also a survey fee of $1,500 per site to

determine how much a client will save and how each unit will be tuned.

Page 14: Power control investor

Sales Cycle

The significant money wasted each month on power factor error and electrical equipment replacement due to failure has shortened the sales cycle to as little as 30-45 days from survey to Purchase Order.

Page 15: Power control investor

The Business Plan

Power Control Company will maintain an assembly facility in Utah to service the Utah/Idaho region.

Utah facility will be utilized as the Power Control Company R&D and Technician Training Center.

Power Control Company will license its patented technology to partner companies and assign exclusive territories. These territories will be exclusive for assembly, distribution and wholesale markets.

Licensees will pay a royalty to Power Control Company for each unit sold.

Page 16: Power control investor

Benefits to the Partner Company

Exclusive technology to existing customers Opens doors for new customers High Margin Product with high demand Short Sales Cycle Low start up costs with low inventory

requirements

Page 17: Power control investor

The Request

Power Control requests a six month loan in the amount of $600,000 (six hundred thousand) USD.

Loan will be collateralized with company assets including its technology patents.

Power Control will pay interest plus a provide an equity component (TBD) in the parent company.

Page 18: Power control investor

Use of Funds

Establish Utah assembly and training facility. Hire and train initial Utah facility technicians. Purchase parts inventory necessary for

assembly of units currently under purchase order or purchase option.

Conduct inspections and surveys for new orders.

Deliver and install first round of units.

Page 19: Power control investor

Contact

Scott Deware

617-799-5702

[email protected]