Nr. 2013/1.10/32 Data: 26.07.13 PLC: SIMATIC S7-1500 più TIA Portal V12 SP 1 Il TIA Portal V12 Service Pack 1 è rilasciato e pronto per fare un download (Le informazioni esistono ancora solo in tedesco) Condizione: La versione TIA Portal V12 deve essere installata e l’utente deve aggiornare tutti i software, non può aggiornare soltanto un software! STEP 7 V12 SP1: Informazione: http://support.automation.siemens.com/WW/view/de/76276623 Download: http://support.automation.siemens.com/WW/view/de/75277515 WinCC V12 SP1: Informazione: http://support.automation.siemens.com/WW/view/de/73947391 Download: http://support.automation.siemens.com/WW/view/de/73956248 STARTDRIVE V12 SP1: Informazione: http://support.automation.siemens.com/WW/view/de/77330014 Download: http://support.automation.siemens.com/WW/view/de/68034568
28
Embed
PLC: SIMATIC S7-1500 più TIA Portal V12 SP 1 4 4 4 4 4 4 4 ... · PLC: SIMATIC S7-1500 più TIA Portal V12 SP 1 ... STEP 7 TIA PORTAL V12 SP 1 2. WinCC TIA Portal V12 SP 1 ... (e.g.
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Nr. 2013/1.10/32 Data: 26.07.13
PLC: SIMATIC S7-1500 più TIA Portal V12 SP 1
Il TIA Portal V12 Service Pack 1 è rilasciato e pronto per fare un download (Le informazioni esistono ancora solo in tedesco)
Condizione:
La versione TIA Portal V12 deve essere installata e l’utente deve aggiornare tutti i software, non può aggiornare soltanto un software!
• STEP 7 SUS verrà consegnato prima e compresaStartdrive AND WinCC Comfort/Advanced DVD
• Clienti riceverà WinCC due volte, se hanno ancheun WinCC SUS contratto
• Dal 26 luglio nuove ordine verràconsegnato con V12 SP1I contratti SUS riceveranno fra 4
settimane I DVD con SP 1
Compatibility mode V11Compatibility mode V11 can be used in V12 SP1 (same as in V12).Projects of V11 can beopened/engineered/stored with TIA Portal V12 SP1. After engineering with V12 SP1 theproject can be used in TIA Portal V11 SP2.
Installazione del SP 1 possibilein parallele con STEP 7 Classico, TIA Portal V10.5 o V11 NON V12
Compatibility of V12 SP1 - projects and devices Upgrade V12 -> V12 SP1
Compatibility at Upgrade V12 to V12 SP1• No compatible repository of V12 and V12 SP1 projects due to new features
• Projects opened in V12 SP1, can’t be edited with V12 anymore• When opening a V12 project with TIA Portal V12 SP1 the user will be advised to upgrade the project • The original V12 project is still available in parallel
• Details HMI• Panels and RT Advanced remain the configured runtime version (V11 or V12) at project upgrade (ES)• Runtime Professional will upgraded automatically to V12 SP1 at project upgrade (ES)• WinCC V12 SP1 allows editing of devices in the runtime versions V11 and V12• The configured runtime version activate the available functionality of the devices• Version changes (V11 V12) will be done by “Change device/version…”
• Details PLC• Engineered V11/V12 PLCs can be opened with STEP 7 V12 SP1• Engineered V12 SP1 PLCs (S7-300, S7-400) can be opened with STEP 7 V12• Engineered V12 SP1 PLCs (S7-1200, S7-1500) can’t be opened with STEP 7 V12
• In the live list V12 all contents (e.g. blocks) with V12 SP1 engineered PLC’s will be marked with a prohibition sign (e.g. opening of a block not possible)
NEW in SP1: Simulation of PID Professional and FailsafeCommunication between PLCSIM-Instances with the following instructions:- PUT/GET- BSend/Brcv- Master-MasterCommunication to local WinCC Runtime
S7-PLCSIM Simulation S7-1500
Simulation of S7-1500 PLC-functionality with Look & Feel of the TIA-Portal+
System diagnosis viewer• Overview of accessible devices and status information of the plant• Switch between device and detail view• Common concept for Comfort Panels, RT Advanced, RT Professional,
CPU Display & CPU web server• View is also available for Basic Panels
SIMATIC HMI Comfort PanelsMixed configuration - extension of the STEP 7 project after migration
When it makes sense to use the TagConverter?Mixed configuration: STEP 7 Classic and WinCC (TIA Portal) after migration of a WinCC flexible projects and extension of the STEP 7 project.
•The TagConverter can be used while engineering after migration. Using the TagConverter it is easy to synchronize tag configuration data in engineering, if the addresses were changed in STEP 7 or if the STEP 7 project was extended.
•The TagConverter is not necessary for process communication in runtime.
•The TagConverter is not necessary for migration.
Scenario 3: Synchronization after changes in STEP 7 ClassicMixed configuration: PLC in STEP7 5.5, HMI in WinCC (TIA Portal)