Technical Document Version 2.0 July 30, 2014 www.cermate.com PLC Connection Guide TN532D-E Siemens S7-1200 Revision Record Revision Date Content Owner V2 2014/07/30 Add description to settings of the database with the Portal software ver 13. Irivine V3 2014/12/23 Add description to settings of the protection for the firmware v4. Irivine
18

PLC Connection Guide _E0.pdfThe Siemens PLC driver timing is related to the CPU characteristic very much. That's why it is not possible to provide one suitable driver for on-line simulation

Sep 16, 2020

Download

Documents

dariahiddleston
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: PLC Connection Guide _E0.pdfThe Siemens PLC driver timing is related to the CPU characteristic very much. That's why it is not possible to provide one suitable driver for on-line simulation

Technical Document

Version 2.0

July 30, 2014

www.cermate.com

PLC Connection Guide

TN532D-E

Siemens S7-1200

◎Revision Record

Revision Date Content Owner

V2 2014/07/30 Add description to settings of the database with the

Portal software ver 13.

Irivine

V3 2014/12/23 Add description to settings of the protection for the

firmware v4.

Irivine

Page 2: PLC Connection Guide _E0.pdfThe Siemens PLC driver timing is related to the CPU characteristic very much. That's why it is not possible to provide one suitable driver for on-line simulation

TND532-E0

Page 2 of 18 www.cermate.com

Siemens S7-1200

This tech. note introduces how to connect Siemens S7-1200 with PanelMaster HMI. User can set

the communication setup in TCP/IP and it can connect Siemens S7-1200 with PanelMaster HMI

by Hub.

Note:

In Siemens PLC driver could not be used under Windows “On-Line Simulation”. This driver is only

used for PM HMI hardware. The Siemens PLC driver timing is related to the CPU characteristic

very much. That's why it is not possible to provide one suitable driver for on-line simulation on

PC.

Page 3: PLC Connection Guide _E0.pdfThe Siemens PLC driver timing is related to the CPU characteristic very much. That's why it is not possible to provide one suitable driver for on-line simulation

TND532-E0

Page 3 of 18 www.cermate.com

PLC setting

A. S7-1200 first time link (PLC is new one no IP address)

1. Set Internet Protocol (TCP/IP) Properties to “Obtain an IP address automatically“.

2. Select the “Accessible devices” to find out the “MAC address”.

Find MAC address,Loading project tree when new product link first time. When

the software find the MAC address, please press “Show project tree” button.

Page 4: PLC Connection Guide _E0.pdfThe Siemens PLC driver timing is related to the CPU characteristic very much. That's why it is not possible to provide one suitable driver for on-line simulation

TND532-E0

Page 4 of 18 www.cermate.com

3. Select “Online & diagnostics” and link with PLC by MAC address.

4. When you link with PLC by MAC address, assign the IP Address=192.168.1.100; Sub

Mask=255.255.255.0.

5. Make sure IP address define success.

Page 5: PLC Connection Guide _E0.pdfThe Siemens PLC driver timing is related to the CPU characteristic very much. That's why it is not possible to provide one suitable driver for on-line simulation

TND532-E0

Page 5 of 18 www.cermate.com

6. Create a new project.

7. Select the correct PLC model.

Page 6: PLC Connection Guide _E0.pdfThe Siemens PLC driver timing is related to the CPU characteristic very much. That's why it is not possible to provide one suitable driver for on-line simulation

TND532-E0

Page 6 of 18 www.cermate.com

8. Key-in the IP=192.168.1.100 and Subnet Mask=255.255.255.0.

9. Download the setting data into PLC.

Page 7: PLC Connection Guide _E0.pdfThe Siemens PLC driver timing is related to the CPU characteristic very much. That's why it is not possible to provide one suitable driver for on-line simulation

TND532-E0

Page 7 of 18 www.cermate.com

10. Select correct IP address and download.

Page 8: PLC Connection Guide _E0.pdfThe Siemens PLC driver timing is related to the CPU characteristic very much. That's why it is not possible to provide one suitable driver for on-line simulation

TND532-E0

Page 8 of 18 www.cermate.com

11. Go Online.

12. Recheck the linking status.

When you see this, it means the PC linking is correct.

Page 9: PLC Connection Guide _E0.pdfThe Siemens PLC driver timing is related to the CPU characteristic very much. That's why it is not possible to provide one suitable driver for on-line simulation

TND532-E0

Page 9 of 18 www.cermate.com

B. If the S7-1200 PLC has IP address inside

1. Select the “Accessible devices” to check the “IP Address”.

2. Create a new project

Page 10: PLC Connection Guide _E0.pdfThe Siemens PLC driver timing is related to the CPU characteristic very much. That's why it is not possible to provide one suitable driver for on-line simulation

TND532-E0

Page 10 of 18 www.cermate.com

3. Select the correct PLC model.

4. Download the setting data into PLC.

Page 11: PLC Connection Guide _E0.pdfThe Siemens PLC driver timing is related to the CPU characteristic very much. That's why it is not possible to provide one suitable driver for on-line simulation

TND532-E0

Page 11 of 18 www.cermate.com

5. Go Online

6. Check link state is correct or not

When you see this, it means the PC linking is correct.

Page 12: PLC Connection Guide _E0.pdfThe Siemens PLC driver timing is related to the CPU characteristic very much. That's why it is not possible to provide one suitable driver for on-line simulation

TND532-E0

Page 12 of 18 www.cermate.com

C. If your software is TIA Portal v13 or higher, please follow the following

settings for communication:

1. Right click mouse in the "Data block" and choose to "Properties".

Page 13: PLC Connection Guide _E0.pdfThe Siemens PLC driver timing is related to the CPU characteristic very much. That's why it is not possible to provide one suitable driver for on-line simulation

TND532-E0

Page 13 of 18 www.cermate.com

2. Uncheck the "Optimized block access" option.

3. The software will show a message window ask you, click "OK".

4. Download settings to S7-1200.

Page 14: PLC Connection Guide _E0.pdfThe Siemens PLC driver timing is related to the CPU characteristic very much. That's why it is not possible to provide one suitable driver for on-line simulation

TND532-E0

Page 14 of 18 www.cermate.com

D. When the firmware version is v4.0 of the S7-1200, please follow these steps

to set up of the "protection options" for the communication.

Check the option of the "Connection mechanisms", such as the red box of the picture, then

redownload the settings to PLC again.

Regarding the detail setting information, please refer to “SIMATIC STEP 7 User Manual”

Page 15: PLC Connection Guide _E0.pdfThe Siemens PLC driver timing is related to the CPU characteristic very much. That's why it is not possible to provide one suitable driver for on-line simulation

TND532-E0

Page 15 of 18 www.cermate.com

HMI Setting

1. Select Siemens S7 PLC and setting the communication parameter.

Page 16: PLC Connection Guide _E0.pdfThe Siemens PLC driver timing is related to the CPU characteristic very much. That's why it is not possible to provide one suitable driver for on-line simulation

TND532-E0

Page 16 of 18 www.cermate.com

PLC Device List

Bit Devices:

Word Devices:

Page 17: PLC Connection Guide _E0.pdfThe Siemens PLC driver timing is related to the CPU characteristic very much. That's why it is not possible to provide one suitable driver for on-line simulation

TND532-E0

Page 17 of 18 www.cermate.com

Cable Diagram

Normal CAT5 cable(Not crossover)can connect. Suggest using a hub between HMI and Lenze

E94AYCEN GCI(TCP/IP) servo driver .

HMI S7-1200

Ethernet connect Ethernet connect

TX(+) 1 1 RX(+)

TX(-) 2 2 RX(-)

RX(+) 3 3 TX(+)

4 4

5 5

TX(-) RX(-) 6 6

7 7

8 8

~Thank You~

Page 18: PLC Connection Guide _E0.pdfThe Siemens PLC driver timing is related to the CPU characteristic very much. That's why it is not possible to provide one suitable driver for on-line simulation

TND532-E0

Page 18 of 18 www.cermate.com

Technical Support Information

中國大陸 QQ專線 : 800014850 www.panelmaster.com.cn / www.cermate.com

資料下載專區 ftp:://mail.cermate.com + User name + Password (欲加入會員需要申請)

合作貼牌聯絡專線: China: 0910011916 / 86-13823788405 [email protected] Taiwan: 886-910011915 [email protected]

Worldwide: 886-910011914 [email protected]

Cermate Technologies (Shanghai) Inc. 屏通科技(上海)有限公司

Phone: +86-21-51758590~2 FAX : +86-21-51758589

E-mail: [email protected]

Shenzhen Cermate Technologies Inc. 屏通科技(深圳)有限公司

Phone: +86-755-83562179, FAX : +86-755-83562294

E-mail: [email protected]

Cermate Technologies Inc. (台湾) 屏通科技股份有限公司 7F-1, No. 168, Lien-Cheng Road, Chung-Ho City, Taipei, Taiwan 235 R.O.C.

Phone: 886-2-22437000 FAX : 886-2-22499933

E-mail: [email protected]