FEATURES • High overall heat transfer coefficient • Compact design gives maximum surface area to material volume without compromising mechanical robustness • High performance with low hold-up volume TECHNICAL DRAWINGS • Versatile, modular design • Plate and gasket materials available to suit most fluid types • Easy dismantling for rapid cleaning • Short lead-time custom build service PLATE HEAT EXCHANGER Cost-effective heat management solution. Whether it is for heating or cooling their efficient operation saves energy, reducing costs and minimising environmental impact. Unit 11, Gunnels Wood Park, Stevenage, Hertfordshire SG1 2BH [email protected]| +44 (0) 1438 749474 www.elecro.co.uk • M A D E I N E N G L A N D • M A D E I N E N G L A N D MATERIALS FRAME PLATES GASKETS HOT SIDE CONNECTIONS COLD SIDE CONNECTIONS BOLTS N.8 M12 P 335 NH Titanium EPDM Max 150°C Stainless Steel Stainless Steel A 193 B7 DESIGN DATA TEMPERATURE °C PRESSURE Bar TEST PRESSURE Bar ‐10/100 10 14.3 DSE276 - EN-Plate Heat Exchanger Data Sheet V1-01-01.2020-Elecro
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
FEATURES
• High overall heat transfer coefficient
• Compact design gives maximum surface areato material volume without compromisingmechanical robustness
• High performance with low hold-up volume
TECHNICAL DRAWINGS
• Versatile, modular design
• Plate and gasket materials available to suitmost fluid types
• Easy dismantling for rapid cleaning
• Short lead-time custom build service
PLATE HEATEXCHANGERCost-effective heat management solution. Whether it is for heating or cooling their efficient operation saves energy, reducing costs and minimising environmental impact.
Unit 11, Gunnels Wood Park, Stevenage, Hertfordshire SG1 2BH
DSE276 - EN-Plate Heat Exchanger Data Sheet V1-01-01.2020-Elecro
SPECIFICATIONS
PROCESS DATA (HOT SIDE)TEMP (IN) ºCTEMP (OUT) ºCFLOW RATE (M3/H)PRESSURE DROP (KPA)PROCESS DATA (COLD SIDE)TEMP (IN) ºCTEMP (OUT) ºCFLOW RATE (M³/H)PRESSURE DROP (KPA)DELTA T LOG. MEAN (ºC)HEAT EXCHANGED (kW)CONSTRUCTION DATAHEAT TRANSFER AREA (M2)OVERSURFACING (%)OVERALL K SERVICE (W/M2 ºC)FOULING F (M2 ºC/kW)PLATES THICKNESS (MM)OVERALL K CLEAN (W/M2 ºC)WEIGHT EMPTY (KG)WEIGHT FULL (KG)VOLUME HOT SIDE (L)VOLUME COLD SIDE (L)NO. SERIES PASS HOT SIDENO.SERIES PASS COLD SIDENO. PARALLEL PASSES HOT SIDENO. PARALLEL PASSES COLD SIDEDIMENSIONS (MM)A (WIDTH)B (CONNECTION INTERAXIS)C (HEIGHT)D (CONNECTION INTERAXIS)E (LENGTH FOR STD PN)F (TIGHTENING)G (CONNECTION SIZE)H (HEIGHT CONNECTIONS)S (FRAME PLATES THK)
PROCESS DATA (HOT SIDE)TEMP (IN) ºCTEMP (OUT) ºCFLOW RATE (M3/H)PRESSURE DROP (KPA)PROCESS DATA (COLD SIDE)TEMP (IN) ºCTEMP (OUT) ºCFLOW RATE (M³/H)PRESSURE DROP (KPA)DELTA T LOG. MEAN (ºC)HEAT EXCHANGED (kW)CONSTRUCTION DATAHEAT TRANSFER AREA (M2)OVERSURFACING (%)OVERALL K SERVICE (W/M2 ºC)FOULING F (M2 ºC/kW)PLATES THICKNESS (MM)OVERALL K CLEAN (W/M2 ºC)WEIGHT EMPTY (KG)WEIGHT FULL (KG)VOLUME HOT SIDE (L)VOLUME COLD SIDE (L)NO. SERIES PASS HOT SIDENO.SERIES PASS COLD SIDENO. PARALLEL PASSES HOT SIDENO. PARALLEL PASSES COLD SIDEDIMENSIONS (MM)A (WIDTH)B (CONNECTION INTERAXIS)C (HEIGHT)D (CONNECTION INTERAXIS)E (LENGTH FOR STD PN)F (TIGHTENING)G (CONNECTION SIZE)H (HEIGHT CONNECTIONS)S (FRAME PLATES THK)