A B C D A C 100 W7 W5 W6 ae 110mmØ UPVC stackpipe & open ventpipe access panel EMERGENCY ESCAPE E Living Room Bedroom Bedroom Kitchen carpet tiles tiles cupb. sink fridge W4 W1 W1 W8 D1 D2 40wp carpet Bathr. tiles cupb. D3 wm 40wp bath whb wc 40wp 40wp ae td sh / cupb. D2 fire wall Living Room Bedroom Bedroom Kitchen carpet tiles tiles cupb. sink fridge W4 W1 W1 D1 40wp carpet Bathr. tiles cupb. wm 40wp bath whb wc 40wp 40wp ae td sh / cupb. fire wall D2 D3 D2 W8 bath 115 from wall bath 115 from wall 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 B C 100 B C 100 9kg dcp fire extinguisher bst 30m 3450 3550 3550 3450 5400 7730 1470 230 340 230 1000 115 400 1000 115 3435 230 3435 115 1000 400 115 2750 115 1400 115 2675 115 1897 230 435 115 3000 230 3000 115 435 115 750 1000 230 340 230 750 115 750 115 115 808 115 2675 115 1400 115 115 2595 115 230 115 2595 115 1180 1770 230 399 472 1925 1195 1480 130 1480 5570 890 1310 890 230 110 230 3395 230 2750 115 815 815 115 2750 230 230 3395 1065 1065 1 2 3 4 A B C D FIRE WALL Means, 230mm wall must extend to underside of roof material Fire wall Ridge Concrete flat roof with fall 1:80 towards outlets Concrete roofslab see engineers drawing with DERBIGUM 4mm SP torch-on waterproofing installed by Derbigum approved contractor according to manufacturers specification. 110mm Side outlet emergency overflow NOTES EXPOSED WOOD All outside exposed wood must be treated with Creosote TRUSSES SA Pine SABS approved Trusses as designed by engineer on max 750mm centres, fix trusses with 2 strands 4mm thick galv. steelwire roof anchors built into walls for at least 600mm. roof anchors to be bent over beams and to be securely nailed to beams, lay trusses on 38x114mm SA Pine SABS approved wallplate. 22.5° 22.5° Chromadek ogee seamless profiled gutters with matching round downpipes. Fullbore and downpipe for draining concrete roof E 650 250 650 650 250 1 2 3 4 A B C D 3450 3550 3550 3450 5400 7730 1470 Living Room Bedroom Bedroom Kitchen carpet tiles tiles cupb. sink fridge stove 1000mm wide paving A C 100 A C 100 W4 W1 W1 W3 W8 W3 D1 D2 110mmØ UPVC stackpipe & open ventpipe 40wp ae 110mmØ UPVC stackpipe & open ventpipe access panel access panel ae ie 110mmØ UPVC SP with 1:60 fall see SITEPLAN carpet 230 340 230 1000 rwp rwp rwp rwp rwp rwp rwp rwp Bathr. tiles cupb. D3 wm 40wp bath whb wc 40wp 40wp ae td sh / cupb. 115 400 1000 115 3435 230 3435 115 1000 400 115 D2 2750 115 1400 115 2675 115 1800 rwp 230 EMERGENCY ESCAPE fire wall gulley ie Sewer must not be less than 600mm deep. 9kg dcp fire extinguisher tiles Staircase 1 2 3 4 5 6 7 bst 30m E Living Room Bedroom Bedroom Kitchen carpet tiles tiles cupb. sink fridge W4 W1 W1 D1 40wp carpet Bathr. tiles cupb. wm 40wp bath whb wc 40wp 40wp ae td sh / cupb. fire wall 435 115 3000 230 3000 115 435 115 750 D2 D3 D2 W8 1000 230 340 230 750 115 750 115 115 750 115 2675 115 1400 115 115 2595 115 rwp 230 bath 115 from wall bath 115 from wall 115 2595 115 ie ie ae ce ie ce ie ae 110mmØ UPVC stackpipe & open ventpipe access panel 1180 1770 230 399 472 B C 100 B C 100 1925 1195 1925 1470 275mm tread 170mm riser 1480 130 1480 5570 890 1310 890 230 110 230 3395 230 2750 115 815 815 115 2750 230 230 3395 ie ie 1065 1065 2400 ce ce ie ie ie A B C D 115 tiles Staircase 1 2 3 4 5 6 7 A C 100 8 9 10 11 12 13 14 15 16 E Living Room Bedroom Bedroom Kitchen carpet tiles tiles cupb. sink fridge W4 W1 W1 D1 40wp carpet Bathr. tiles cupb. wm 40wp bath whb wc 40wp 40wp ae td sh / cupb. fire wall Living Room Bedroom Bedroom Kitchen carpet tiles tiles cupb. sink fridge W4 W1 W1 D1 40wp carpet Bathr. tiles cupb. wm 40wp bath whb wc 40wp 40wp ae td sh / cupb. fire wall D2 D3 D2 D2 D3 D2 W8 bath 115 from wall bath 115 from wall B C 100 B C 100 9kg dcp fire extinguisher bst 30m 3450 3550 3550 3450 5400 7730 1470 230 340 230 1000 115 400 1000 115 3435 230 3435 115 1000 400 115 2750 115 1400 115 2675 115 1897 230 435 115 3000 230 3000 115 435 115 750 1000 230 340 230 750 115 750 115 115 808 115 2675 115 1400 115 115 2595 115 230 115 2595 115 1180 1770 230 399 472 1925 1195 1925 1470 1480 130 1480 5570 890 1310 890 230 110 230 3395 230 2750 115 815 815 115 2750 230 230 3395 1065 1065 0-Ground Floor 0 Roof 8160 A B C D 01-First Floor 2720 02-Second Floor 5440 2720 2720 2720 E Steel balustrades 1 000mm high. Concrete roof tiles, see SECTIONS. Steel painted window frames Window cills outside, Concrete precast see SECTIONS Plaster and paint Face brick Face brick Plaster and paint Fire barrier see detail Fire barrier see detail Fire barrier see detail Fire barrier see detail 1 2 3 4 min 600mm min 150mm 2720 2720 2720 Marley Double Roman “Plus” standard Red concrete roof tiles,laid in straight bond with minimum 75mm headlap, fix according to manufacturers specifications, on 38 x 38mm SA Pine battens at max. 345mm centres, 38x50mm SA Pine tilting (starting) batten, on Marley Under Tile Membrane with joints lapped 150mm, fixed between battens and trusses. Steel balustrades 1 000mm high. Gutter Watertite Guttering domestic Ogee profile 125 x 85 x 0,6mm Chromadek seamless, colour Silver White, complete, fix according to manufacturers specifications on fascia, with 75 x 50 x 0,6mm thick Chromadek downpipes. Isotherm 130mm thick polyester thermal insulation laid over ceiling brandering closely fitted between rafters. All work to manufacturers specifications. 22.5º 22.5º Ceiling Gyproc 6,4mm Rhinoboard, fix according to manufacturers specifications onto 38 x 38mm SA Pine brandering at 400mm centres,with plastic M-Strip cover strips over joints. SA Pine trusses SABS approved as designed by specialist on max. 750mm centres, on 38x114mm SABS approved wall plate, fixed onto wall with 2x4mm roof binding wires built in min. 7 courses deep. Screed 25mm cement with finish see elsewhere on 85mm concrete surface bed on Gundle USB Green co ex 250µm damp proof membrane under concrete surface beds to SANS mark 952-1985 type C laid with minimum 150mm overlaps and sealed with Gunplas pressure sensitive tape. On 50mm sand layer on well compacted ground. Face brick Strip foundations / Raft concrete see engineers drawings . dpc dpc Living room Entrance/ Kitchen 50 Living room Living room 1360 1360 1360 1360 85 85 85 170 170 170 275 275 275 Entrance/ Kitchen Entrance/ Kitchen 650 0-Ground Floor 0 Roof 8160 A B C D 01-First Floor 2720 02-Second Floor 5440 2720 2720 2720 40wp Sink 40wp Sink 40wp Sink 110mmØ UPVC stackpipe & open ventpipe Ventcowl ie 110mmØ UPVC SP with 1:60 fall see SITEPLAN E 40wp Sink 40wp Sink 40wp Sink ie Concrete roof tiles, see SECTIONS. Window cills outside, Concrete precast see SECTIONS Plaster and paint Face brick Face brick Plaster and paint 0-Ground Floor 0 Roof 8160 1 2 3 4 01-First Floor 2720 02-Second Floor 5440 110mmØ UPVC stackpipe & open ventpipe Ventcowl 40wp Bath/shower wc wc wc ae ae ae 110mmØ UPVC SP with 1:60 fall see SITEPLAN ie 40wp Bath/shower 40wp Bath/shower ce 0-Ground Floor 0 Roof 8160 1 2 3 01-First Floor 2720 02-Second Floor 5440 22.5º 22.5º Window cills outside, Concrete precast similar and approved to Modcon. Living room Kitchen Living room Kitchen Living room Kitchen dpc dpc dpc dpc dpc 650 650 Concrete structure see engineers drw. 1 2 3 4 110mmØ UPVC stackpipe & open ventpipe Ventcowl 40wp Bath/shower wc wc wc ae ae ae 110mmØ UPVC SP with 1:60 fall see SITEPLAN ie 40wp Bath/shower 40wp Bath/shower ce Scale Checked by Drawn by Date Project number CC BK ARCHITECTS ARGITEKTE JH NEETHLING E-Mail: [email protected] Fax: Tel: Menlo Park 0102 Ashlea Gardens Office Park PO Box 35862 Building 3, 1st Floor, 180 Garstfontein Avenue Die ontwerp op hierdie tekening bly die eiendom van die argitek - Kopiereg Voorbehou - Alle afmetings moet op terrein nagegaan word voor enige werk begin word. Enige foute moet onmiddelik aan die argitek geraporteer word. Hierdie tekening mag nie afgeskaal word nie. Drawing index 700 600 500 100 001 200 CONSTRUCTION DETAILS DRAINAGE DOOR SCHEDULES PLANS SITE PLAN ELEVATIONS 300 400 SECTIONS WINDOW SCHEDULES 800 OFFICE LAYOUTS / TENANT INSTALLATIONS 900 OTHER SCHEDULES Client Project Geysers to comply with SABS 0254 Notes Chimneys to comply with Part V of NBR. Glazing to comply with NBR. 0137 according to the SANS 10137 All traps to be anti-vac Sheet no. Type SK WD SDP CP SKETCH PLAN WORKING DRAWING SITE DEVELOPMENT PLAN COUNCIL PLAN WJ dE KLERK Pr Arch (Reg no. 3638) Pr Arch (Reg no. 2977) 460-1776/7 460-4059 (012) (012) Revision Rev. no. 1 : 100 2015/02/24 11:23:23 AM Plans, Elevations, Sections 2007-372 Revised drawings--- New Residential Development on erf 118 Annlin West x23 Pretoria UNIT TYPE C UNIQON WONINGS 2013-12-02 Le Sueur H Neethling C 100 1 : 100 02-Second Floor 3 Glass to comply with SABS 0400 National Building Regulations TABLE- DIMENSIONS OF GLASS: Nominal thickness of glass Maximum size of glass m² Safety glass in sliding door must be marked with visible band. SEWER NOTE: All traps must be anti vac. traps, Strenghten wall across sewer pipes 3mm 4mm 5mm 6mm 0.75 1.5 2.1 3.2 1 : 100 Roofplan 4 No. Description Date 1 : 100 0-Ground Floor 1 1 : 100 01-First Floor 2 1 : 100 North elevation 5 1 : 100 Section AA A 1 : 100 South elevation 7 1 : 100 West elevation 8 1 : 100 Section BB B 1 : 100 East Elevation 6