2925 2675 3580 9180 A A 21530 2500 2600 LIVING ROOM KITCHEN/ DINING W.C 19.9m² 20.3m² ST 0.7sqm 5 1 900 3800 5470 1250 2320 UTL/ST 2.5m² 1500 10765 HALL 3855 5470 6170 HOUSE TYPE C HOUSE TYPE C obscure glazing A A BEDROOM 2 BEDROOM 3 BEDROOM 1 EN-SUITE BATH 5 15 11.8m² 7.5 m² 13.4m² HP/ST 1.1sqm 2360 1175 4060 3600 2650 1850 3205 LANDING 10765 6170 HOUSE TYPE C 3520 Attic Hatch Folding attic stairs to provide access to attic storage area 3.5m 2 2925 2675 3580 9180 HOUSE TYPE C obscure glazing obscure glazing 2925 2675 3580 9180 HOUSE TYPE C1 obscure glazing LIVING ROOM KITCHEN/ DINING W.C 19.9m² 20.3m² ST 0.7sqm 5 1 900 3800 5470 1250 2320 UTL/ST 2.5m² 1500 10765 HALL 3855 5470 HOUSE TYPE C1 BEDROOM 2 BEDROOM 3 BEDROOM 1 EN-SUITE BATH 5 15 11.8m² 7.5 m² 13.4m² ST 1.8sqm 2360 1175 4060 3600 2650 1850 3205 LANDING 10765 HOUSE TYPE C1 3520 Attic Hatch Folding attic stairs to provide access to attic storage area 3.5m2 HOUSE TYPE C1 obscure glazing obscure glazing 2925 2675 3580 9180 1800 Ground Floor Level +0.000 First Floor Level +2.925 Attic Storage Level +5.600 Ridge Level +9.180 GROUND FLOOR PLAN House Type C-C1 56sq.m OA 112sqm - 1205 sq.ft FIRST FLOOR PLAN House Type C-C1 56sq.m SIDE ELEVATION House Type C SIDE ELEVATION House Type C1 HALL SECTION A-A BEDROOM 3 ATTIC STORAGE min 9 sq.m Indicitive Solar Panel or Photovoltiac panels indicated, Final Solar Panel Position Depends on House Orientation.The solar panels shown are a provisional option to satisfy renewable energy requirements of building regs part L. Solar panels may be omitted in favour of alternative renewable energy source. Ground Floor Level +0.000 First Floor Level +2.925 Attic Storage Level +5.600 Ridge Level +9.180 REAR ELEVATION House Type C-C1 FRONT ELEVATION House Type C-C1 Ground Floor Level +0.000 First Floor Level +2.925 Attic Storage Level +5.600 Ridge Level +9.180 Ground Floor Level +0.000 First Floor Level +2.925 Attic Storage Level +5.600 Ridge Level +9.180 sub sub sub sub sub sub sub sub sub sub sub sub SW/A1.011 sub sub STOP STOP STOP STOP STOP STOP STOP STOP STOP STOP STOP STOP STOP STOP STOP STOP STOP BUS BUS BUS BUS STOP STOP STOP STOP STOP STOP REVISIONS DATE DESCRIPTION No. NOTES: DO NOT SCALE FROM DRAWINGS. WORK TO FIGURED DIMENSIONS ONLY. ARCHITECT TO BE NOTIFIED OF ALL DISCREPANCIES. DRAWING TITLE: PROJECT TITLE: DATE: DRAWN BY: SCALE: REVISION: JOB NO: DRAWING NO: M CROSSAN O ROURKE MANNING c ARCHITECTS M C 1 Grantham Street, Dublin 8, D08 A49Y, Ireland. Tel: 01-4788700 Fax: 01-4788711 E-Mail: [email protected] HOUSE TYPE C/C1 Plans, Sections & Elevations Coosan, Athlone A 1:100 CL Jan'20 18029 PL12 TYPE C/C1 - 3 BED - SEMI-DETACHED TYPE C/C1 - 3 BED - SEMI-DETACHED HOUSE TYPES 2 STOREY C/C1 BED 3 SEMI-DETACHED SQM / 112 SQF 1205 C/C1 THIS DRAWING TO BE READ IN CONJUNCTION WITH ARCHITECT'S DRAWINGS, CONSULTANT ENGINEER'S DRAWINGS AND SPECIFICATIONS & LANDSCAPE ARCHITECTS DRAWINGS REFER TO ARCHITECT'S SITE PLAN PL02 FOR NORTH ORIENTATION. LEVELS GIVEN ON HOUSE TYPE DRAWINGS ARE GIVEN TO A LOCAL ABSOLUTE ZERO LEVEL. FOR SPECIFIC LEVELS DEPENDING ON INDIVIDUAL UNIT LOCATION, REFER TO ARCHITECT'S CONTEXT SECTIONS AND ENGINEER'S DRAWINGS WHERE LEVELS ARE ARE ALL GIVEN IN RELATION TO LAND SURVEYOR'S BENCHMARK BASED ON MALIN HEAD DATUM LEVEL. ROOF : TO BE FINISHED IN SLATE OR CONCRETE ROOF TILES IN SELECTED COLOUR OR SIMILAR APPROVED. WALLS : SELECTED CLAY BRICKWORK WHERE INDICATED OTHERWISE PAINTED SAND / CEMENT RENDER OR SELF COLOURED RENDER. EXPRESSED BANDS AROUND EXTERNAL OPES/ EXPRESSED LINTOLS OVER EXTERNAL OPES WHERE INDICATED TO BE RECONSTITUTED STONE (LIGHT CREAM LIMESTONE OR GRANITE EFFECT) OR RENDER JOINERY : ALL WINDOWS AND DOORS, FRAMES AND LEAVES, TO BE ALUMINIUM POWDER-COATED TO APPROVED COLOUR OR uPVC. OBSCURE GLAZING WHERE INDICATED TO SENSITIVE WINDOWS. RAINWATER GOODS : GUTTERS, DOWNPIPES, AND FIXINGS TO BE uPVC OR ALUMINIUM POWDER COATED TO SELECTED COLOUR TO MATCH ROOF SLATES G E N E R A L N O T E S N O T E S O N F I N I S H E S : SOLAR PANELS: INDICATIVE SOLAR PANEL POSITION, FINAL SOLAR PANEL POSITION DEPENDS ON HOUSE ORIENTATION. THE SOLAR PANELS SHOWN ARE A PROVISIONAL OPTION TO SATISFY RENEWABLE ENERGY REQUIREMENTS OF BUILDING REGS PART L. SOLAR PANELS MAY BE OMITTED IN FAVOUR OF ALTERNATIVE RENEWABLE ENERGY SOURCE. * N KEY PLAN Scale - 1:2500 30-3-20 General update for planning A