PIT: Programmable Interval Timer

Introduction to 8253/8254

Page 2: PIT: Programmable Interval Timer Introduction to 8253/8254.

Timer Description and Initialization• PIT (programmable Interval Timer)

• The 8253 chip was used in the IBM PC/XT, but starting with the IBM PC/AT, the 8254 replaced the 8253.

• 8253 and 8254 have exactly the same pinout.

• 8254 is a superset of the 8253.

8253/54 Timer

Page 3: PIT: Programmable Interval Timer Introduction to 8253/8254.

Programmable Interval Timer - 8254

Page 4: PIT: Programmable Interval Timer Introduction to 8253/8254.

Pin Diagram

Page 5: PIT: Programmable Interval Timer Introduction to 8253/8254.
Page 6: PIT: Programmable Interval Timer Introduction to 8253/8254.

A0, A1, and CS

• Inside the 8253/54 timer, there are 3 counters.

• Each timer works independently and programmed separately.

• Each counter is assigned an individual port address.

• The control register common to all 3 counters and has its own port.

Pin Description of 8253/54

Page 7: PIT: Programmable Interval Timer Introduction to 8253/8254.
Page 8: PIT: Programmable Interval Timer Introduction to 8253/8254.

CLK

• CLK is the input clock frequency, which can range between 0 and 2 MHz for the 8253.

• For input frequencies higher than 2 MHz, the 8254 must be used.

• The 8254 can go as high as 8 MHz, and 8254-2 can go 10 MHz.

OUT

• Can have square-wave, one-shot, and other square-shape waves for various duty cycles but no sine-wave or saw-tooth shapes.

Gate

• This pin is used to enable or disable the counter.

Page 9: PIT: Programmable Interval Timer Introduction to 8253/8254.

D0-D7

• The D0-D7 data bus of the 8253/54 is a bidirectional bus connected to D0-D7 of the system data bus.

• RD and WR are connected to IOR and IOW control signals of the system bus.

Initialization of the 8253/54

• Each of the three counters of the 8253/54 must be programmed separately.

• The 8253/54 must be initialized before it is used.

Page 10: PIT: Programmable Interval Timer Introduction to 8253/8254.
Page 11: PIT: Programmable Interval Timer Introduction to 8253/8254.
Page 12: PIT: Programmable Interval Timer Introduction to 8253/8254.
Page 13: PIT: Programmable Interval Timer Introduction to 8253/8254.
Page 14: PIT: Programmable Interval Timer Introduction to 8253/8254.

The figure shows the one-byte control word of the 8253/54.

• D0 chooses between a binary number divisor of 0000 to FFFFH or a BCD divisor of 0000 to 9999H.

• The highest number is 216 for binary and 104 for BCD.

• To get the highest count, the counter is loaded with zeros.

• D1, D2, and D3 are for mode selection.

Control word

Page 15: PIT: Programmable Interval Timer Introduction to 8253/8254.

• D4 and D5 are for RL0 and RL1

• RL0 and RL1 are used to indicate the size of the divisor, and have 3 options:

1. Read/write MSB only

2. Read/write LSB only

3. Read/write LSB first followed immediately by the MSB.

Page 16: PIT: Programmable Interval Timer Introduction to 8253/8254.

Mode 0 Interrupt on terminal count

Mode 1 Programmable one-shot

Mode 2 Rate Generator

Mode 3 Square wave rate generator

Mode 4 Software triggered strobe

Mode 5 Hardware trigger strobe

Operation Modes

Page 17: PIT: Programmable Interval Timer Introduction to 8253/8254.

• All counters are down counters.

• D6 and D7 are used to select the 3 counters, counter 0, counter 1, or counter 2, is to be initialized by the control byte.

• To program a given counter of the 8253/54 to divide the CLK input frequency one must send the divisor to that specific counter’s reg.

• To divide the frequency by 10000 (BCD) or 65536 (binary) we must send in 0 for both high and low bytes.

Page 18: PIT: Programmable Interval Timer Introduction to 8253/8254.
Page 19: PIT: Programmable Interval Timer Introduction to 8253/8254.
Page 20: PIT: Programmable Interval Timer Introduction to 8253/8254.
Page 21: PIT: Programmable Interval Timer Introduction to 8253/8254.

IBM PC 8253/54 Timer Connections and Programming

Page 22: PIT: Programmable Interval Timer Introduction to 8253/8254.

• The three clocks of the 8253, CLK0, CLK1, and CLK2, are all connected to a constant frequency of 1.1931817 MHz.

• PCLK of the 8284 is 2.3863663 MHz and must be divided by 2.

• GATE0 and GATE1 enable counter0 and counter 1 respectively.

• GATE2 of counter 2 can be enabled or disabled through PB0 of port B of the 8255.

Page 23: PIT: Programmable Interval Timer Introduction to 8253/8254.
Page 24: PIT: Programmable Interval Timer Introduction to 8253/8254.

CLK0 of counter 0 is 1.193 MHz, and GATE0 is connected permanently.

• OUT0 is connected to IRQ0 of the 8259 interrupt controller to provide time-of-day (TOD) interrupt.

• IRQ0 is activated 18.2 times per second. (18.2 Hz)

• The counter must to divide 1.193 MHz by 65,536.

Using counter 0

Page 25: PIT: Programmable Interval Timer Introduction to 8253/8254.

• The wave shape is a square wave.

• D0 = 0 for the binary value.

• D3 D2 D1 = 011, mode 3

• D4 D5 = 11, for reading/writing the LSB first, followed by MSB.

• D7 D6 = 00, for counter 0.

Using counter 0

Page 26: PIT: Programmable Interval Timer Introduction to 8253/8254.
Page 27: PIT: Programmable Interval Timer Introduction to 8253/8254.

• The function of IR0 is not only taking care of the TOD clock.

• BIOS will make this interrupt available by going to the vector table of INT 1CH.

Using counter 0

Page 28: PIT: Programmable Interval Timer Introduction to 8253/8254.

• In counter 1, CLK1 is connected to 1.193 MHz and GATE is high.

• OUT1 generates a periodic pulse required to refresh DRAM memory of the computer.

• The refreshing must be done at least 15s (66278Hz) for each cell, and is performed by DMA.

• Counter must divide the input frequency 1.19318 MHz by 18.

• DRAM maximum frequency refresh time is 2 ms.

Using Counter 1

Page 29: PIT: Programmable Interval Timer Introduction to 8253/8254.

D0 = 0 for binary option

D3 D2 D1 = 010, for mode 2 shape output.

D5 D4 = 01, for LSB only

D7 D6, for counter 1.

D7~D0 = 0101 0100 = 54H for the control word.

Using Counter 1

Page 30: PIT: Programmable Interval Timer Introduction to 8253/8254.

The output of counter 2 is connected to two different devices: the speaker and PC5 of the 8255.

Use of timer 2 by the speaker

• In the IBM PC, CLK2 is connected to a frequency of 1.19318 MHz and GATE2 is programmed by PB0 of port 61H (port B).

• The IBM PC uses counter 2 to generate the beep sound.

• The beep sound has a frequency of 896 Hz (divisor = 1331)

Using Counter 2

Page 31: PIT: Programmable Interval Timer Introduction to 8253/8254.
Page 32: PIT: Programmable Interval Timer Introduction to 8253/8254.

• The process of turning on the speaker is the same for all IBM PCs and compatibles from 8088-based to 80486 and Intel’s Pentium-based systems.

• Gate2 must be high to provide the CLK to timer 2.

• This function is performed by PB0 of port 61H.

The following is the code to turn the speaker on.

Turning on the speaker via PB0 and PB1 of port 61H

Page 33: PIT: Programmable Interval Timer Introduction to 8253/8254.

Turning on the speaker via PB0 and PB1 of port 61H

Page 34: PIT: Programmable Interval Timer Introduction to 8253/8254.

Creating time delays in 8088/86-based PC/XT, PS2, and compatibles

MOV CX, N

AGAIN: LOOP AGAIN

The above codes can be used to generate delays (N T 17 seconds)

• Approximate delay time

• The delay is not only frequency dependent but also CPU dependent.

• IBM provides a scheme to create a time delay using hardware that is not only frequency but also CPU independent.

Time delay for 80x86 PCs

Page 35: PIT: Programmable Interval Timer Introduction to 8253/8254.

The following method of creating hardware time delays was first implemented in the IBM PC and compatible computers.

• To create a processor independent delay, IBM made PB4 of port 61H toggle every 15.085s.

• CS holds 15.085s in the following codes.

Time delays in 80x86 IBM PC

Page 36: PIT: Programmable Interval Timer Introduction to 8253/8254.

Time delays in 80x86 IBM PC

Page 37: PIT: Programmable Interval Timer Introduction to 8253/8254.

• Now a time delay of any duration can be created regardless of the CPU frequency as long as it is a 286 and higher PC.

• For example set CX=33144 (3314415.085s=0.5 second)

MOV CX, 33144

CALL WAITF

Time delays in 80x86 IBM PC

Page 38: PIT: Programmable Interval Timer Introduction to 8253/8254.

Time delays in 80x86 IBM PC

Page 39: PIT: Programmable Interval Timer Introduction to 8253/8254.

Example

Page 40: PIT: Programmable Interval Timer Introduction to 8253/8254.

Examples

Page 41: PIT: Programmable Interval Timer Introduction to 8253/8254.

• As mentioned earlier, counter 2 is connected to the speaker and it can be programmed to output any frequency that is desired.

• Look at the list of piano notes and their frequencies given in Fig. 5-5.

• Music: frequency and time duration

Generating Music on the IBM PC

Page 42: PIT: Programmable Interval Timer Introduction to 8253/8254.
Page 43: PIT: Programmable Interval Timer Introduction to 8253/8254.
Page 44: PIT: Programmable Interval Timer Introduction to 8253/8254.

A delay of 250 ms

Page 45: PIT: Programmable Interval Timer Introduction to 8253/8254.
Page 46: PIT: Programmable Interval Timer Introduction to 8253/8254.
Page 47: PIT: Programmable Interval Timer Introduction to 8253/8254.
Page 48: PIT: Programmable Interval Timer Introduction to 8253/8254.
Page 49: PIT: Programmable Interval Timer Introduction to 8253/8254.

Shape of 8253/54 Outputs

Page 50: PIT: Programmable Interval Timer Introduction to 8253/8254.

IBM BIOS programmed counter 0 to create mode 3, which is square-wave shape.

• Counter 0 is loaded with the number 65,536 and the clock period of input frequency 838 ns (1/1.193 MHz = 838 ns), so the period of the OUT0 pulse is equal to 65536838 ns = 54.9 ms (18.2 Hz).

• OUT0 continuously sends out square wave pulses.

Out0 pulse shape in IBM BIOS

Page 51: PIT: Programmable Interval Timer Introduction to 8253/8254.

IBM BIOS programmed counter 1 in mode 2, rate generator, with the value 18 loaded into the counter.

• OUT1 will be high for a total of 17 838 ns and go low for one pulse of 838 ns

• GATE1 is set to 1 permanently

Out1 pulse shape in the IBM BIOS

Page 52: PIT: Programmable Interval Timer Introduction to 8253/8254.

IBM BIOS loads the value 1331 into counter 2.

• Since 1331 is an odd number, the OUT2 pulse is high for a total of (1331+1)/2 = 666 838 ns and is low for a total of (1331-1)/2 = 665 838 ns

OUT2 pulse shape in the IBM BIOS

Page 53: PIT: Programmable Interval Timer Introduction to 8253/8254.

The output in this mode is initially low, and will remain low for the duration of the count if GATE = 1.

Width of low pulse = NT

Where N is the the clock count loaded into counter, and T is the clock period of the CLK input.

Mode 0: interrupt on terminal count

Page 54: PIT: Programmable Interval Timer Introduction to 8253/8254.

When the terminal count is reached, the output will go high and remain high until a new control word or new count number is loaded.

• In this mode, if GATE input becomes low at the middle of the count, the count will stop and the output will be low.

• The count resumes when the gate becomes high again.

• This in effect adds to the total time the output is low.

Mode 0: interrupt on terminal count

Page 55: PIT: Programmable Interval Timer Introduction to 8253/8254.
Page 56: PIT: Programmable Interval Timer Introduction to 8253/8254.
Page 57: PIT: Programmable Interval Timer Introduction to 8253/8254.
Page 58: PIT: Programmable Interval Timer Introduction to 8253/8254.

• This mode is also called hardware triggerable one-shot.

• The triggering must be done through the GATE input by sending a 0-to-1 pulse to it.

• The following two steps must be performed:

1. Load the count registers.

2. A 0-to-1 pulse must be sent to the GATE input to trigger the counter.

• Contrast this with mode 0, in which the counter produces the output immediately after the counter is loaded as long as GATE = 1.

• In mode 1 after sending the 0-to-1 pulse to GATE, OUT becomes low and stays low for a duration of NT, then becomes high and stays high until the gate is triggered again.

Mode 1: programmable one-shot

Page 59: PIT: Programmable Interval Timer Introduction to 8253/8254.
Page 60: PIT: Programmable Interval Timer Introduction to 8253/8254.
Page 61: PIT: Programmable Interval Timer Introduction to 8253/8254.

Mode 2 is also called divide-by-N counter.

• In this mode, if GATE = 1, OUT will be high for the NT clock period, goes low for only one clock pulse, then the count is reloaded automatically, and the process continues indefinitely.

Mode 2: rate generator

Page 62: PIT: Programmable Interval Timer Introduction to 8253/8254.
Page 63: PIT: Programmable Interval Timer Introduction to 8253/8254.

In this mode if GATE = 1, OUT is a square wave where the high pulse is equal to the low pulse if N is an even number.

• In this case the high part and low part of the pulse have the same duration and are equal to (N/2)T (50% duty cycle)

• If N is an odd number, the high pulse is one clock pulse longer.

• This mode is widely used as a frequency divider and audio-tone generator.

Mode 3: square wave rate generator

Page 64: PIT: Programmable Interval Timer Introduction to 8253/8254.
Page 65: PIT: Programmable Interval Timer Introduction to 8253/8254.
Page 66: PIT: Programmable Interval Timer Introduction to 8253/8254.

•In this mode if GATE = 1, the output will go high upon loading the count.

• It will stay high for the duration of NT.

• After the count reaches zero (terminal count), it becomes low for one clock pulse, then goes high again and stays high until a new command word or new count is loaded.

• To repeat the strobe, the count must be reloaded again.

• Mode 4 is similar to mode 2, except that the counter is not reloaded automatically.

• In this mode, the count starts the moment the count is written into the counter.

Mode 4: software trigger strobe

Page 67: PIT: Programmable Interval Timer Introduction to 8253/8254.
Page 68: PIT: Programmable Interval Timer Introduction to 8253/8254.
Page 69: PIT: Programmable Interval Timer Introduction to 8253/8254.
Page 70: PIT: Programmable Interval Timer Introduction to 8253/8254.

• This mode is similar to mode 4 except that the trigger must be done with the GATE input.

• In this mode after the count is loaded, we must send a low-to-high pulse to the gate to start the counter.

Mode 5: hardware trigger strobe

Page 71: PIT: Programmable Interval Timer Introduction to 8253/8254.