Pipe Freeze Protection

Page 2: Pipe Freeze Protection. 2 XL-Trace Systems Pipe Freeze Protection and Flow Maintenance.

2

XL-Trace Systems

•Pipe Freeze Protection and Flow Maintenance

Page 3: Pipe Freeze Protection. 2 XL-Trace Systems Pipe Freeze Protection and Flow Maintenance.

3

System Overview

Page 4: Pipe Freeze Protection. 2 XL-Trace Systems Pipe Freeze Protection and Flow Maintenance.

4

Applications

• Above or Underground

• Freeze Protection

– General Water Piping

– Sprinkler Piping

• Flow Maintenance

– Grease Disposal Lines

– Fuel Lines

Page 5: Pipe Freeze Protection. 2 XL-Trace Systems Pipe Freeze Protection and Flow Maintenance.

5

Consequences of system failure

•Frozen or clogged pipes

•Environmental hazard from spills

•Equipment damage

•Loss of production

•Life-safety issues

Page 6: Pipe Freeze Protection. 2 XL-Trace Systems Pipe Freeze Protection and Flow Maintenance.

6

Determine Design Conditions

Page 7: Pipe Freeze Protection. 2 XL-Trace Systems Pipe Freeze Protection and Flow Maintenance.

7

Select Heating Cable Output

Page 8: Pipe Freeze Protection. 2 XL-Trace Systems Pipe Freeze Protection and Flow Maintenance.

8

Remember: Heating cable only maintains the temperature of stagnant fluid by replacing the heat lost through the thermal insulation

Pipe Heat Tracing

Heating cable power output

Insulation thickness

Pipe size (D)

Heat LossAmbient temperature

Page 9: Pipe Freeze Protection. 2 XL-Trace Systems Pipe Freeze Protection and Flow Maintenance.

9

Determine Voltage & Jacket

•Select Heating Cable Voltage

•Select Outer Jacket

Page 10: Pipe Freeze Protection. 2 XL-Trace Systems Pipe Freeze Protection and Flow Maintenance.

10

Determine Heating Cable Length

Page 11: Pipe Freeze Protection. 2 XL-Trace Systems Pipe Freeze Protection and Flow Maintenance.

11

Determine Heating Cable Length

Page 12: Pipe Freeze Protection. 2 XL-Trace Systems Pipe Freeze Protection and Flow Maintenance.

12

Select Temperature Controls

•Manual control

•Ambient thermostat

•Line sensing thermostat

•Solid-state Controller

•Tie into BMS

Page 13: Pipe Freeze Protection. 2 XL-Trace Systems Pipe Freeze Protection and Flow Maintenance.

13

Controls

AMC-1BLine sensing Thermostat

AMC-1AAmbient sensing Thermostat

AMC-F5Fixed 40°F setpoint Thermostat

DigiTrace 910Solid-state Temperature Controller with Ground Fault Protection

Page 14: Pipe Freeze Protection. 2 XL-Trace Systems Pipe Freeze Protection and Flow Maintenance.

14

Determine Number of Circuits

•Use the heating cable number to determine the maximum circuit length

Page 15: Pipe Freeze Protection. 2 XL-Trace Systems Pipe Freeze Protection and Flow Maintenance.

15

Calculate Transformer Load 16

•Use the total amount of heating cable and the maximum A/ft from table 7 to calculate the total transformer load.

Page 16: Pipe Freeze Protection. 2 XL-Trace Systems Pipe Freeze Protection and Flow Maintenance.

16

RayClic Components

Page 17: Pipe Freeze Protection. 2 XL-Trace Systems Pipe Freeze Protection and Flow Maintenance.

17

Product line - 6 connections

•RayClic-PC Power Connection

•RayClic-T Tee

•RayClic-S Splice

•RayClic-X Cross

•RayClic-PS Powered Splice

•RayClic-PT Powered Tee

Page 18: Pipe Freeze Protection. 2 XL-Trace Systems Pipe Freeze Protection and Flow Maintenance.

18

Accessories

•GT-66 Glass tape

•AT-180 Aluminum tape

•ETL Warning labels (every 10’)