Top Banner
Pipe baffle shaking tests S.Braccini, C.Bradaschia, I.Fiori, F.Paoletti Mid Baffle First Baffle
15

Pipe baffle shaking tests S.Braccini, C.Bradaschia, I.Fiori, F.Paoletti Mid Baffle First Baffle.

Dec 18, 2015

Download

Documents

Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Pipe baffle shaking tests S.Braccini, C.Bradaschia, I.Fiori, F.Paoletti Mid Baffle First Baffle.

Pipe baffle shaking tests

S.Braccini, C.Bradaschia, I.Fiori, F.Paoletti

Mid Baffle First Baffle

Page 2: Pipe baffle shaking tests S.Braccini, C.Bradaschia, I.Fiori, F.Paoletti Mid Baffle First Baffle.

1410 m West

No DAQ

hammershake

quiet

MID BAFFLEEXCITATION

Page 3: Pipe baffle shaking tests S.Braccini, C.Bradaschia, I.Fiori, F.Paoletti Mid Baffle First Baffle.

NO EFFECTON DARK FRINGE

Mid baffle seismic noise is not now limiting the sensitivity

(Noise upper limit can be set)

Page 4: Pipe baffle shaking tests S.Braccini, C.Bradaschia, I.Fiori, F.Paoletti Mid Baffle First Baffle.

)(~)(~

)(~

)(~

0 fxfx

fhfh

Excitation

ySensitivitNoise

)(~)(~)(

~

)(~)()(~

00 fxfx

fhfxfTFfh

Excitation

ySensitivitUpperLimitNoise

Page 5: Pipe baffle shaking tests S.Braccini, C.Bradaschia, I.Fiori, F.Paoletti Mid Baffle First Baffle.

)(~)(~

0 fxKfhNoise Constant TF

K 4 x 10-15 m -1

)(~104)(~

015 fxfhNoise

hammershake

quiet

)40(~)40(~

0 HzxKHzhNoise 6 x 10 -22

1.5 x 10 -7

Page 6: Pipe baffle shaking tests S.Braccini, C.Bradaschia, I.Fiori, F.Paoletti Mid Baffle First Baffle.

Upper limit by mid baffle for any constant TF process

Adv Sensitivity

……. Another step…Beyond single baffle

Page 7: Pipe baffle shaking tests S.Braccini, C.Bradaschia, I.Fiori, F.Paoletti Mid Baffle First Baffle.

h ( ƒ ) = - - - - - - 1 2

( 2 ) - 5 / 4

g 1 / 2

L - 1 / 2 b ' - 3 / 2

k = 1

n b a f f l e s - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

x k ( 1 - x k )

x k 2 + ( 1 - x k )

2 F ( m )

1 / 2

( ƒ )

0.0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.00.00

0.10

0.20

0.30

0.40

0.50

0.60e = 0

e=0.05

e=0.1

e=0.2

x

weight of baffles vs location for various offsets of the optical axis

Upper limit for diffraction on all baffles

AdV Sensitivity

Upper Limit

Theory with detected seismic noise

We know the weight of each baffle with respect to the central one(dominant) where we have just set un upper limit

OTHER REMARKS

Same seismic noise on all pipe mid baffles

No special effect on a single baffle

North Pipe could be different

Page 8: Pipe baffle shaking tests S.Braccini, C.Bradaschia, I.Fiori, F.Paoletti Mid Baffle First Baffle.

A) No hypothesis Mid baffle seismic noise does not affect presentsensitivity (but only scarce upper limit can be set)

B) Flat TF hypothesis Good upper limit for seismic noise by Mid baffle

CONCLUSIONS FROM MID BAFFLE TEST

C) Extension to all baffles(Theoretical Model and Assumptions)

Upper limit for diffraction on all baffles

AdV Sensitivity

Upper Limit

Theory with detected seismic noise

Gives us an upper limit for the entire“diffraction noise”

It is easy (but not urgent)to improve upper limit…

Page 9: Pipe baffle shaking tests S.Braccini, C.Bradaschia, I.Fiori, F.Paoletti Mid Baffle First Baffle.

Pipe baffle shaking tests

S.Braccini, C.Bradaschia, I.Fiori, F.Paoletti

Mid Baffle First Baffle

Page 10: Pipe baffle shaking tests S.Braccini, C.Bradaschia, I.Fiori, F.Paoletti Mid Baffle First Baffle.

hammer

shake

quiet

Excitation

Page 11: Pipe baffle shaking tests S.Braccini, C.Bradaschia, I.Fiori, F.Paoletti Mid Baffle First Baffle.

Excitation

Page 12: Pipe baffle shaking tests S.Braccini, C.Bradaschia, I.Fiori, F.Paoletti Mid Baffle First Baffle.

No Effect on DF

Page 13: Pipe baffle shaking tests S.Braccini, C.Bradaschia, I.Fiori, F.Paoletti Mid Baffle First Baffle.

Present “Safety Margin” (no hypothesis)

Page 14: Pipe baffle shaking tests S.Braccini, C.Bradaschia, I.Fiori, F.Paoletti Mid Baffle First Baffle.

First Baffle Upper Limit (Flat TF hypothesis)

Page 15: Pipe baffle shaking tests S.Braccini, C.Bradaschia, I.Fiori, F.Paoletti Mid Baffle First Baffle.

CONCLUSIONS FROM FIRST BAFFLE TEST

Conceptually identical to the Mid Baffle ones (but different seismic noise)

A) No hypothesis Mid baffle seismic noise does not affect presentsensitivity (but only scarce upper limit can be set)

B) Flat TF hypothesis Good upper limit for seismic noise by Mid baffle

C) Extension to all baffles(Theoretical Model and assumptions)

Uncoherent sums with different seismic noise (all baffle weight 1)