ARC FLASH CLOTHING &
ACCESSORIES
172 FR SHIRTS
174 FR SWEATSHIRTS
176 ARC/FR BALACLAVAS
177 ARC PROTECTION JACKETS, OVERALLS & COVERALLS
178 40 CAL/CM2 HYBRID FABRIC TECHNOLOGY
179 ARC PROTECTION KITS
181 ARC RATED HI-VIS VESTS
182 ARC PROTECTION ACCESSORIES
ELECTRICAL SAFETY PRODUCTS
172
AR
C F
LA
SH
CLO
TH
ING
800-
262-
5755
//
PIP
US
A.C
OM
HAZARD RISK PROTECTIVE EQUIPMENT PROTECTIVE CLOTHING MIN
ARC RATING
00• Safety Glasses or safety goggles
(SR)• Hearing protection
(ear canal inserts)• Heavy duty leather gloves**
• Shirt• Pants
Non-melting or untreated natural fiber (untreated cotton or wool) with a
fabric weight of at least 4.5 oz/yd²
• Hard hat• Safety glasses or safety goggles
(SR)• Hearing protection
(ear canal inserts)• Heavy duty leather gloves**• Leatherwork shoes
• Arc-rated long sleeve shirt and pants or arc-rated coverall
• Arc-rated face shield or arc flash suit hood• Arc-rated jacket, parka, rainwear or hard hat liner
4 cal/cm2
• Hard hat• Safety glasses or safety goggles
(SR)• Hearing protection
(ear canal inserts)• Heavy duty leather gloves**• Leatherwork shoes
• Arc-rated long sleeve shirt and pants or arc-rated coverall
• Arc-rated face shield or arc flash suit hood and arc rated balaclava
• Arc-rated jacket, parka, rainwear or hard hat liner
8 cal/cm2
• Hard hat• Safety glasses or safety goggles
(SR)• Hearing protection
(ear canal inserts)• Heavy duty leather gloves**• Leather work shoes
• Arc-rated long sleeve shirt • Arc-rated pants• Arc-rated coverall• Arc-rated arc flash suit jacket• Arc-rated arc flash suit pants• Arc-rated arc flash suit hood• Arc-rated gloves• Arc-rated jacket, parka, rainwear or hard hat liner
25 cal/cm2
• Hard hat• Safety glasses or safety goggles
(SR)• Hearing protection
(ear canal inserts)• Heavy duty leather gloves**• Leather work shoes
• Arc-rated long sleeve shirt • Arc-rated pants• Arc-rated coverall• Arc-rated arc flash suit jacket• Arc-rated arc flash suit pants• Arc-rated arc flash suit hood• Arc-rated gloves (See note below)• Arc-rated jacket, parka, rainwear or hard hat liner
** NFPA 70 E Table 130.7(C)(16) Note 1 – The combination of rubber insulating gloves and leather protectors satisfies the arc flash protection requirements.
Standard Inseam for Coveralls, Bib Overalls, and Overpants: 32”
HOwdOeSiTwORk?Proprietary yarns and a very tight construction greatly reduce the effects of wind chill, the Achilles heel of traditional fleece. We have proven its effectiveness both in the lab and in the field. Polartec® Wind Pro® FR is 4 times more wind resistant than traditional fleece and the flame resistant fiber provides extreme flame protection. Velour or pebbled back efficiently traps air and provides a high warmth-to-weight ratio. Because it is not a laminate, Polartec® Wind Pro® FR is also highly breathable, maintaining 85% of the breathability of traditional fleece to keep you from over heating.
TeCHNiCaLHiGHLiGHTS• Made with a unique blend of fibers for permanent flame resistance• Will not melt or drip• 4 times more wind resistant than traditional fleece• Warmth without the weight• Water repellent surface sheds rain and snow• Very breathable for active use• Durable• Machine washable
Polartec Windpro FR 1/4 Zip
>> 67% Modacrylic / 29% Rayon / 4% Spandex, 12.5 oz>> ARC rating: EBT 9.1 cal/cm2>> HRC 2>> 1/4” Zip Collar>> Front Pocket>> Chest Pocket
>> Shell: DuPont® Protera® (Fiber Blend: 33% NOMEX and KEVLAR, 65% Modacrylic, 2% Antistatic) >> Inside Layer: Westex® Ultrasoft® Interlock Knit (88% Cotton, 12% High Tenacity Nylon)>> Ventilating unit and power pack are protected by a compact and durable ABS case covered by Ultralight fabric>> Unit Weight: 1 lb (16 oz)>> Battery Life: 6+ usable hours>> Airflow: 35 cfm>> Meets ASTM Standard F2178-12
Lighter is Better.37% Better.NEW Ultralight 40 cal/cm2 clothing utilizes a Hybrid Fabric Technology to increase garment durability in the field while decreasing its weight by 37%. Our Ultralight garment uses a DuPont shell to provide its superior tensile strength, industrial wash resistance, and long-term durability.
• 40 cal/cm2 Hybrid Fabric Technology• High tensile stength and greater tear resistance• 2x more breathable • 37% lighter than traditional HRC4 garments • Meets NFPA 70E, ASTM F1506, OSHA 29 CFR 1910.269
40cal/cm2
hYBriD FABriC TECHNOLOGY
Kits
>> Includes: Hood, Jacket, Pants, Safety Glasses, Hard Hat, and Carrying Bag
ARC Protection Kits: Class 2CESG’s HRC 2 Arc Flash kits are designed to meet your Hazard Risk Category 2 needs. These kits provide you with the components needed to be in compliance with the new NFPA 70E 2012 standard.
ARC Protection Kits: Class 3For higher voltage situations, HRC 3 & 4 Arc Flash kits are designed to meet your Hazard Risk Category 3 & 4 needs (insulating glove kits and arc rated hearing protection sold separately). The kits come with safety helmet and arc hood in addition to the components needed to be in compliance with the new NFPA 70E 2012 standards.
The Arc Flash Hood incorporates UV and IR-absorbing window providing protection up to 100 cal/cm2. Past generations of gold reflective faceshields only provided up to 7.33 cal/cm2 of protection, and the typical clear faceshield only 1.2 cal/cm2.
The green tint window is coated with a permanent anti-fog inner surface. Item #9400-52509 Storage Bag Available for Hood.
Arc Hoods are supplied with Hard Hat Adapter and Safety Helmet.
FR Apparel Bag
>> Molded Rubber Bottom>> Zipper Closure>> Size: 24”L x 10”W x 13”H
9400-52599
ITEM # DESCRIPTION ARC RATING HAZARD RISK
9150-56510 ARC Shield: Hard hat included 12 cal/cm2