90 North Cutler Drive • P.O. Box 540445 North Salt Lake, UT 84054-0445 Phone: (801) 292-2956 • Fax: (801) 292-4164 Email: [email protected]Salt Lake City - Phoenix - Denver - Dallas “Lightning Protection and Grounding Solutions for Industry” SUBMITTAL FOR Physicians Choice Lab Rock Hill, SC (JOB# SC00150) LIGHTNING PROTECTION SYSTEM BY: VFC February 12, 2013 Albuquerque Albuquerque Albuquerque Albuquerque Local Installer P: (575) 993-0041 Dallas Dallas Dallas Dallas 1240 Texan Trail Suite 108Grapevine, TX 76501 P: (817) 488-4788 F: (817) 488-4757 Denver Denver Denver Denver 14 Inverness Drive East No. A140 Englewood, CO 80112 P: (303) 649-4905 F: (303) 649-4906 Las Vegas Las Vegas Las Vegas Las Vegas Local Installer P: (702) 206-3155 Phoenix Phoenix Phoenix Phoenix 125 South 48th Street Suite 110 Tempe, AZ 85282 P: (480) 966-0175 F: (480) 966-0184 Raleigh / Durham Raleigh / Durham Raleigh / Durham Raleigh / Durham 112-A Wheaton Drive Youngsville, NC 27614 P: (919) 556-0685 Hamilton Hamilton Hamilton Hamilton 200 Whitehead Road Suite #219 Hamilton, NJ 08619 P: (609) 781-0382 San Antonio San Antonio San Antonio San Antonio 1015 Creek Corner San Antonio, TX 78253 P: (210) 724-5004 F: (210) 679-5310 Salt Lake City Salt Lake City Salt Lake City Salt Lake City 90 North Cutler Drive North Salt Lake, UT 84054 (800) 825-1948 (801) 292-4164
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
90 North Cutler Drive • P.O. Box 540445 North Salt Lake, UT 84054-0445 Phone: (801) 292-2956 • Fax: (801) 292-4164 Email: [email protected]
Salt Lake City - Phoenix - Denver - Dallas
“Lightning Protection and Grounding Solutions for Industry”
SUBMITTAL FOR
Physicians Choice Lab Rock Hill, SC
(JOB# SC00150)
LIGHTNING PROTECTION SYSTEM
BY:
VFC February 12, 2013
AlbuquerqueAlbuquerqueAlbuquerqueAlbuquerque Local Installer
P: (575) 993-0041
DallasDallasDallasDallas 1240 Texan Trail
Suite 108Grapevine, TX 76501
P: (817) 488-4788 F: (817) 488-4757
DenverDenverDenverDenver 14 Inverness Drive East
No. A140 Englewood, CO 80112
P: (303) 649-4905 F: (303) 649-4906
Las VegasLas VegasLas VegasLas Vegas Local Installer
P: (702) 206-3155
PhoenixPhoenixPhoenixPhoenix 125 South 48th Street
Suite 110 Tempe, AZ 85282 P: (480) 966-0175 F: (480) 966-0184
San AntonioSan AntonioSan AntonioSan Antonio 1015 Creek Corner
San Antonio, TX 78253 P: (210) 724-5004 F: (210) 679-5310
Salt Lake CitySalt Lake CitySalt Lake CitySalt Lake City 90 North Cutler Drive
North Salt Lake, UT 84054 (800) 825-1948 (801) 292-4164
smyrick
New Stamp
smyrick
Typewritten Text
X
smyrick
Typewritten Text
SM
smyrick
Typewritten Text
2/13/13
caddis
MCA Shop Drawing
caddis
Typewritten Text
X
caddis
Typewritten Text
CLA 14 FEB 2013
caddis
Typewritten Text
caddis
Typewritten Text
CAVINESS LAMBERT ENGINEERING, LLC
CAVINESS LAMBERT ENGINEERING, LLC508 East North Street Greenville, SC 29601 864-242-5844
Memorandum
Project: PCLS, Rock Hill, SC Subject: Lightning Protection Submittal Date: Feb. 13, 2013 Prepared by: David Lambert – Caviness Lambert Engineering, LLC
1. General: o System shall be installed in accordance with NEC, and NFPA 780 as well as applicable
lightning protection code. o Provide UL Master Labeled lightning protection system. Note that surge protection is
integral to this system. o Coordinate installation with other disciplines to ensure dissimilar metals are not in
contact with each other in wet/damp locations. o Coordinate roof penetrations with owner, architect and general contractor.
Notify Engineer for approval of any equipment that needs to be installed in locations other than what is shown on the plans, or if not shown at all. Furnish As Submitted Revise and Resubmit Furnish as Corrected Submit Specified Item
Corrections or comments made on the shop drawings during this review do not relieve the contractor from compliance with the requirements of the specifications and drawings. This check is only for review of general conformance with the design concept of the project and general compliance with the information given in the contract documents. The contractor is responsible for conforming and correlating all quantities and dimensions; selecting fabrication processes and techniques of construction; coordinating contractor’s work with that of all other trades; and performing work in a safe and satisfactory manner.
CAVINESS LAMBERT ENGINEERING, LLC
Date 02/13/2013 By DML .
90 North Cutler Drive • P.O. Box 540445 North Salt Lake, UT 84054-0445 Phone: (801) 292-2956 • Fax: (801) 292-4164 Email: [email protected]
Salt Lake City - Phoenix - Denver - Dallas
“Lightning Protection and Grounding Solutions for Industry”
ITEM NO. PRODUCT DESCRIPTION MANUFAC-
TURE
Letter: Quality Assurance Letter
Letter: Galvanic Compatibility Required by UL 96A
2 No. LPA100 Aluminum Class I Conductor (24) ERICO ®
3 No. LC150 Copper Bonding Conductor ERICO ®
4 No. LPA222ST Aluminum 1/2" x 12” Class I Air Terminal ERICO ®
5 No. LPA225ST Aluminum 1/2" x 24” Class I Air Terminal ERICO ®
6 No. LPC30212 Bronze 1/2” Stamped Adhesive Point Base ERICO ®
7 No. LPC502 Bronze One Bolt Parallel Connector ERICO ®
8 No. LPC502A Bi-Metal One Bolt Parallel Connector ERICO ®
9 No. LPA540 Aluminum Bonding Plate ERICO ®
10 No. LPC559 Bronze Cable to Flat Metal Clamp ERICO ®
1 No. LPC120 Copper Class I Conductor (29) ERICO ®
90 North Cutler Drive • P.O. Box 540445 North Salt Lake, UT 84054-0445 Phone: (801) 292-2956 • Fax: (801) 292-4164 Email: [email protected]
Salt Lake City - Phoenix - Denver - Dallas
“Lightning Protection and Grounding Solutions for Industry”
February 12, 2013 Andrew Electric Co, Inc 950 Cripple Creek Dr Lawrenceville, GA 30043 P: 770-995-0101 F: 770-995-7934 Attn: Robert Cash Re: Physicians Choice Lab Rock Hill, SC Please accept this letter as our certification that all of the Lightning Protection Components supplied by VFC Inc. are manufactured to the specifications of Underwriters Laboratories UL 96, “Lightning Protection Components”. All VFC Inc. Lightning Protection Products are listed with U.L. and undergo U.L. Factory Inspections. Manufacturing # OVTZ.E202878 Installation # OWAY.E129857 VFC Inc. is a member in good standing of the Lightning Protection Institute, and employs L.P.I. Certified Journeymen, Master Installers, and Master Installer/Designers. Todd Vought, VFC’s Vice President of Business Development, is an L.P.I. Certified Master Installer/Designer #861. If you have any questions, or require any additional information, just let me know.
Sincerely,
Todd D. Vought V.P. of Business Development
AlbuquerqueAlbuquerqueAlbuquerqueAlbuquerque Local Installer
P: (575) 993-0041
DallasDallasDallasDallas 1240 Texan Trail
Suite 108Grapevine, TX 76501
P: (817) 488-4788 F: (817) 488-4757
DenverDenverDenverDenver 14 Inverness Drive East
No. A140 Englewood, CO 80112
P: (303) 649-4905 F: (303) 649-4906
Las VegasLas VegasLas VegasLas Vegas Local Installer
P: (702) 206-3155
PhoenixPhoenixPhoenixPhoenix 1230 West Southern Ave
Suite 105 Tempe, AZ 85282 P: (480) 966-0175 F: (480) 966-0184
San AntonioSan AntonioSan AntonioSan Antonio 1015 Creek Corner
San Antonio, TX 78253 P: (210) 724-5004 F: (210) 679-5310
Salt Lake CitySalt Lake CitySalt Lake CitySalt Lake City 90 North Cutler Drive
North Salt Lake, UT 84054 (800) 825-1948 (801) 292-4164
90 North Cutler Drive • P.O. Box 540445 North Salt Lake, UT 84054-0445 Phone: (801) 292-2956 • Fax: (801) 292-4164 Email: [email protected]
Salt Lake City - Phoenix - Denver - Dallas
“Lightning Protection and Grounding Solutions for Industry”
February 12, 2013 Andrew Electric Co, Inc 950 Cripple Creek Dr Lawrenceville, GA 30043 P: 770-995-0101 F: 770-995-7934 Attn: Robert Cash Re: Physicians Choice Lab Rock Hill, SC Portions of the Lightning Protection System will have to be mounted to the structure being protected. Lightning Protection materials are bare copper and may accelerate corrosion on other metals that are not galvanically compatible; for example, the copper material should not be mounted on any aluminum surface, bare zinc, or galvanized sheet metal. If the surface is one of the materials listed above, VFC will need to switch to the appropriate aluminum equivalent material as required by code. Aluminum materials meet all applicable Lightning Protection requirements, but are sized larger to eliminate any difference in impedance. If you have any questions, or if I can be of any assistance, please let me know. Sincerely,
Todd D. Vought Vice President of Business Development
AlbuquerqueAlbuquerqueAlbuquerqueAlbuquerque Local Installer
P: (575) 993-0041
DallasDallasDallasDallas 1240 Texan Trail
Suite 108Grapevine, TX 76501
P: (817) 488-4788 F: (817) 488-4757
DenverDenverDenverDenver 14 Inverness Drive East
No. A140 Englewood, CO 80112
P: (303) 649-4905 F: (303) 649-4906
Las VegasLas VegasLas VegasLas Vegas Local Installer
P: (702) 206-3155
PhoenixPhoenixPhoenixPhoenix 1230 West Southern Ave
Suite 105 Tempe, AZ 85282 P: (480) 966-0175 F: (480) 966-0184
90 North Cutler Drive • P.O. Box 540445 North Salt Lake, UT 84054-0445 Phone: (801) 292-2956 • Fax: (801) 292-4164 Email: [email protected]
Salt Lake City - Phoenix - Denver - Dallas
“Lightning Protection and Grounding Solutions for Industry”
Points Bases, Braces, and Accessories System 2000—Series 300
Bronze or aluminum stamped adhesive point base for use on flat, vertical or sloping surface. Positive single bolt tension for multi-directional cable clamp-ing. Four mounting holes for bolts or screws. Air terminal support tab is field adjustable for any angle as shown from 0-90° eliminating the need for swivel adaptors. -Field adjustable tool part number LPT302
Note:
• Available in tinned copper (eg. LPC302L12, tinned copper, 1/2” point).
• Also available pre-configured for vertical appli-cations (eg. LPA30212V, aluminum 1/2” point, factory set for vertical applications).
POINT DIA. COPPER ALUMINUM
3/8” LPC30238 -
1/2” LPC30212 LPA30212
5/8” LPC30258 LPA30258
SERIES 302 - UNIVERSAL POINT BASE
ITEM #6
90 North Cutler Drive • P.O. Box 540445 North Salt Lake, UT 84054-0445 Phone: (801) 292-2956 • Fax: (801) 292-4164 Email: [email protected]
Salt Lake City - Phoenix - Denver - Dallas
“Lightning Protection and Grounding Solutions for Industry”
ITEM #7 AND ITEM #8
Clamps, Splices, Plates, & Lugs System 2000—Series 500
Stamped bronze or aluminum universal par-allel cable splicer. May be used with any combination of full size cables and/or minia-ture bonding wire or cables. Positive single bolt tension grip on cables or wire. Total contact length 1-1/2”
Series 527 (contact length 2”)
LPC502 for copper
LPA502 for aluminum
LPC502A for bi-metallic
LPC502L for tinned copper
SERIES 502
ITEM #9
Clamps, Splices, Plates, & Lugs System 2000—Series 500
Cast bronze or aluminum flat metal bonding plate. Single bolt tension grip on cable. For use with all full size ca-bles. 8 square inches of contact sur-face.
Series 540
LPC540 for copper cables to com-patible metal surface
LPC540L for copper cables to dis-similar metal surface
LPA540 for aluminum cables to compatible metal surface.
SERIES 540
90 North Cutler Drive • P.O. Box 540445 North Salt Lake, UT 84054-0445 Phone: (801) 292-2956 • Fax: (801) 292-4164 Email: [email protected]
Salt Lake City - Phoenix - Denver - Dallas
“Lightning Protection and Grounding Solutions for Industry”
ITEM #10
Clamps, Splices, Plates, & Lugs System 2000—Series 500
Cast bronze or aluminum universal cable to beam flange or purlin flange bonding clamp. Requires no holes in heave steel member. For use with all full size cables and bonding cables and wires.
Series 557 Gives 8 square inches of bolt tension contact. Draws tight on mem-ber thickness up to 1”.
Series 559 Provides bolt tension contact. Draws tight on member thickness up to 5/8”.
Series 557
LPC557 for copper cable and wire
LPA527 for aluminum cable and wire
Series 559
LPC559 for copper cable and wire
LPA559 for aluminum cable and wire
SERIES 557 & 559 - BEAM/PURLIN Flange Bonding Clamps
ITEM #11
Clamps, Splices, Plates, & Lugs System 2000—Series 500
Cast bronze or aluminum terminal bonding lug with set screw pressure on miniature cables and wires. Lug hole for 1/4” diameter bold. For use with all miniature bonding cables and wires
Series 555
LPC555 for copper miniature cables and wires
LPC555L (tinned) for copper minia-ture cables and wires
LPA555 for aluminum miniature ca-bles and wires
SERIES 555
90 North Cutler Drive • P.O. Box 540445 North Salt Lake, UT 84054-0445 Phone: (801) 292-2956 • Fax: (801) 292-4164 Email: [email protected]
Salt Lake City - Phoenix - Denver - Dallas
“Lightning Protection and Grounding Solutions for Industry”
ITEM #12 AND ITEM #13
Clamps, Splices, Plates, & Lugs System 2000—Series 500
Copper or aluminum pipe bonding clamp made of stainless steel u-bolt with tinned copper strap. Suitable for pipe sizes from 2” to 6-1/2” O.D. Can be used with all cable sizes and incorporated with Series 321 for point mounting. For pipe sizes greater than 6-1/2” O. D. refer to Series 588 and 590.
SERIES 596 - PIPE CLAMPS
COPPER ALUMINUM PIPE RANGE O.D.
LPC5962 LPA5962 2” - 2-5/8”
LPC5963 LPA5963 2-5/8” - 3-5/8”
LPC5964 LPA5964 4” - 4-1/2”
LPC5965 LPA5965 4-1/2” - 6-1/2”
ITEM #14
Machined aluminum bi0metallic connector for making connections between copper and aluminum cables in straight run. Two-bolt tension grip on each cable end. For use with all full size cables. For cables sizes up to 4/0.
SERIES 598 - BI-METALLIC CONNECTOR
Series 598
LPA598 For aluminum to copper cables
Clamps, Splices, Plates, & Lugs System 2000—Series 500
90 North Cutler Drive • P.O. Box 540445 North Salt Lake, UT 84054-0445 Phone: (801) 292-2956 • Fax: (801) 292-4164 Email: [email protected]
Salt Lake City - Phoenix - Denver - Dallas
“Lightning Protection and Grounding Solutions for Industry”
ITEM #15
Clamps, Splices, Plates, & Lugs System 2000—Series 500
Strap copper or aluminum pipe bond-ing clamp. Suitable for pipe sizes from 6-5/8” to 10-3/4” O.D. Other sizes available upon request. For use with all full size cables
Series 588 (O.D. range 6-5/8” - 8-5/8”
LPC588 for copper cables
LPA588 for aluminum cables
Series 590 (O.D. range 8-5/8” - 10-3/4”
LPC590 for copper cables
LPA590 for aluminum cables
SERIES 588 & 590 - PIPE CLAMPS
ITEM #16
ZEROPEN* SYSTEM
90 North Cutler Drive • P.O. Box 540445 North Salt Lake, UT 84054-0445 Phone: (801) 292-2956 • Fax: (801) 292-4164 Email: [email protected]
Salt Lake City - Phoenix - Denver - Dallas
“Lightning Protection and Grounding Solutions for Industry”
ITEM #17
Cable Strap - Copper, One Hole
LPC801 3/8” secured with nails
LPC803 1/2” secured with nails or screws
LPC805 5/8” secured with screws or 1/4” fasteners
LPC807 1-1/4” secured with screws or 1/4” fasteners
Cable Strap - Aluminum, One Hole
LPA801 3/8” secured with nails or screws
LPA803 1/2” secured with nails or screws
LPA805 5/8” secured with screws or 1/4” fasteners
LPA807 1-1/4” secured with screws or 1/4” fasteners
Cable Strap - Copper, Two Hole
LPC802 3/8” secured with nails
LPC804 1/2” secured with nails or screws
LPC806 5/8” secured with screws or 1/4” fasteners
LPC808 1-1/4” secured with screws or 1/4” fasteners
LPA804 1/2” secured with nails or screws
LPA806 5/8” secured with screws or 1/4” fasteners
LPA808 1-1/4” secured with screws or 1/4” fasteners
Cable Strap - Aluminum, Two Hole
Series 801, 803, 805, 807 Copper Strap, One Hole
Series 802, 804, 806, 808 Copper Strap, One Hole
Fasteners System 2000—Series 800
90 North Cutler Drive • P.O. Box 540445 North Salt Lake, UT 84054-0445 Phone: (801) 292-2956 • Fax: (801) 292-4164 Email: [email protected]
Salt Lake City - Phoenix - Denver - Dallas
“Lightning Protection and Grounding Solutions for Industry”
ITEM #18
Fasteners System 2000—Series 800
Flat cable holder for use with hot pitch, roofing compound or commercial adhesive on built-up roof surfaces or other loca-tions where holes cannot be made for anchoring cable.
SERIES 809 & 810 - CABLE HOLDERS
LPC809 for copper cables
LPA809 for aluminum cables
Series 809
Series 809 Cast bronze or aluminum. Bolt tension cable holder.
Series 810 Copper or aluminum. Compression type fingers crimped over cable
LPC810 for copper cables
LPA810 for aluminum cables
Series 810
ITEM #19
Fasteners System 2000—Series 800
SHEET METAL SCREWS
A927P022 Stainless steel hex pan-head sheet metal screw #10 x 5/8”
A927P023 Stainless steel hex pan-head self-drilling tek screw #10 x 5/8”
A927P025 Stainless steel hex pan-head sheet metal screw #10 x 1”
A927P024 Stainless steel hex pan-head self-drilling tek screw #10 x 1”
90 North Cutler Drive • P.O. Box 540445 North Salt Lake, UT 84054-0445 Phone: (801) 292-2956 • Fax: (801) 292-4164 Email: [email protected]
Salt Lake City - Phoenix - Denver - Dallas
“Lightning Protection and Grounding Solutions for Industry”
• Solid conductor can be either copper or Copperweld.
ITEM #21
WELD METAL
CADWELD WELD METAL CADWELD Weld Metal is a mixture of copper oxide and aluminum, packaged by size in plastic tubes. Each tube contains the starting material at the bottom of the plastic tube, with the Weld Metal on top. These materials are not explosive and not subject to spontaneous ignition. These containers are pack-aged in boxes along with metal disks. Each weld uses one disk. Five types of CADWELD Weld Metal are used for grounding connections:
1. F20 or standard Weld Metal is used for all grounding connections with the exception of those to cast iron or to load bearing rail. The standard Weld Metal containers have clear (or natural) caps. Stan-dard Weld Metal is also used with most FX molds.
2. XL Weld Metal is used with EXOLON molds. EXOLON Weld Metal containers have white caps. 3. XF-19 Alloy Weld Metal is used for all connections to cast iron such as Type HB and others. XF-19
Weld Metal containers have orange caps. For DUCTILE IRON, See Section 3, Cast Iron Connections. 4. CADWELD F80 Alloy Weld Metal is used for all connections to load bearing rail such as Type W
Bonds. F80 Weld Metal containers have yellow caps. 5. Cathodic connections require different weld metal and molds. Contact factory for cathodic connection
applications.
90 North Cutler Drive • P.O. Box 540445 North Salt Lake, UT 84054-0445 Phone: (801) 292-2956 • Fax: (801) 292-4164 Email: [email protected]
Salt Lake City - Phoenix - Denver - Dallas