RAB Lighting Inc. Xiao Xiang,15921313292,[email protected] Prepared By Prepared By Approved By Wangzun Zhu Kevin Jia The results contained in this report pertain only to the tested sample. This report shall not be reproduced, except in full, without written approval of Deliver Co.,Ltd. This report must not be used by the client to claim product certification, approval, or endorsement by NVLAP. Block 11, 78 Keling Road, SSTP, Suzhou, China Test Date Issue Date 2021/1/19 2021/1/28 Photometric Test Report Relevant Standards RANSI C82.77:2017 RIES LM-79-2008 Prepared For Room 6A33, No.1388, Wuzhong road,Shanghai ,China DLF2101106 DLF2101106-32a 0512-66801950,[email protected] Project Number Report Number Deliver Co.Ltd. Doc No.: DLFLAB-ZY-01-28 Version:1.0 Page 1 of 23
23

Photometric Test Report - RAB Lighting

Jan 23, 2022

Download

Documents

dariahiddleston
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Photometric Test Report - RAB Lighting

RAB Lighting Inc.

Xiao Xiang,15921313292,[email protected]

Prepared By

Prepared By Approved By

Wangzun Zhu Kevin Jia

The results contained in this report pertain only to the tested sample.

This report shall not be reproduced, except in full, without written approval of Deliver Co.,Ltd.

This report must not be used by the client to claim product certification, approval, or endorsement by NVLAP.

Block 11, 78 Keling Road, SSTP, Suzhou, China

Test Date

Issue Date

2021/1/19

2021/1/28

Photometric Test Report

Relevant Standards

RANSI C82.77:2017

RIES LM-79-2008

Prepared For

Room 6A33, No.1388, Wuzhong road,Shanghai ,China

DLF2101106

DLF2101106-32a

0512-66801950,[email protected]

Project Number

Report Number

Deliver Co., Ltd.

Doc No.: DLFLAB-ZY-01-28 Version:1.0 Page 1 of 23

Page 2: Photometric Test Report - RAB Lighting

DLC Technical Requirements v5.1

Test value

7658

Standard

105

Premium

120120.3

63.6

8.06%

0.996

7 step 3045±175

4 step 3045±100

73

-32

75

91

-18%

37.99%

15.73%

480

0.133

Zonal Lumen Requirement (60°-80°)

(Goniophotometer - Section 4.2)IES LM-79-2008 ≥30%

IES LM-79-2008Input Current (A)

(Goniophotometer - Section 4.2)Worst Case

Input Voltage (V)

(Goniophotometer - Section 4.2)IES LM-79-2008 Worst Case

1.0  Test Summary

Outdoor - Parking Garage Luminiares

2000

Requirement Category Test Method Requirements

Luminaire Output (lm)

(Goniophotometer - Section 4.2)IES LM-79-2008

Worst Case

Power Factor

(THD & PF - section 4.3)ANSI C82.77:2014

20.00%

0.9

IES Rcs,h1

(Integrating Sphere - Section 4.1)ANSI/IES TM-30-18 -18%≤IES Rcs,h1≤+23%

Allowable CCTs* (K)

(Integrating Sphere - Section 4.1)IES LM-79-2008

Minimum Luminaire Efficacy (lm/W)

(Goniophotometer - Section 4.2)IES LM-79-2008

Total Harmonic Distortion (A%)

(THD & PF - section 4.3)ANSI C82.77:2014

Power (Input Wattage) (W)

(Goniophotometer - Section 4.2)IES LM-79-2008

4768

Minimum CRI

(Integrating Sphere - Section 4.1)

IES LM-79-2008

CIE 13.3-1995

Zonal Lumen Requirement (70°-80°)

(Goniophotometer - Section 4.2)IES LM-79-2008

≥70

≤25%

Minimum R9

(Integrating Sphere - Section 4.1)

IES LM-79-2008

CIE 13.3-1995≥-40

Minimum Rf

(Integrating Sphere - Section 4.1)≥70

Minimum Rg

(Integrating Sphere - Section 4.1)ANSI/IES TM-30-18 ≥89

ANSI/IES TM-30-18

Doc No.: DLFLAB-ZY-01-28 Version:1.0 Page 2 of 23

Page 3: Photometric Test Report - RAB Lighting

2.0  Test List

Test Item Test Date Sample No.

1 2021/1/19 AF1

2 2021/1/19 AF1

3 2021/1/19 AF1

Remark(If any)

3.0 Production Description

Luminaire Description: IVGT5CU-70L750W4

Electrical Specification: 480V,50/60HZ

Test Model Number

IVGT5CU-70L750W4

IVGT5CU-70L750W4

Integrating Sphere Test

Goniophotometer Test

1、This report shall not be used by the client to claim product endorsement by NVLAP,

NIST or any agency of the US government.

2、The results reported herein have been performed in accordance with the laboratory’s

terms of accreditation. This report shall not be reproduced except in full without the written

approval of the Laboratory. The results in this report apply to the test sample(s)

mentioned above at the time of the testing period only and are not to be used to indicate

applicability to other similar products. This report does not imply that the product(s) has

met the criteria for certification.

Photos of Luminaire Characteristics

IVGT5CU-70L750W4THD and PF Test

Doc No.: DLFLAB-ZY-01-28 Version:1.0 Page 3 of 23

Page 4: Photometric Test Report - RAB Lighting

Test Method

75 91 -18%

R9

-32

Rf Rg IES Rcs,h1

4768 73

The sample measurements were made using a spectroradiometer connected by a fiber optic

cable and detector through the detector port of the integrating sphere.

56.0

4.0 LM-79 Measurement and Test Results

4.1 Integrating Sphere Test

Model No. IVGT5CU-70L750W4 Sample ID. AF1

90Stabilization

time (Min.)45

The samples were tested according to the IES LM-79-2008.

Photometric paramters were measured using an integrating sphere, a spectroradiometer and

software. The ambient temperature condition inside the sphere was maintained at 25º C ± 1º C.

Opreate time

(Min.)

Voltage (Vac) Frequency (Hz) Current (A) Power (W) Power Factor

0.0059

479.99 60 0.133

Temperature

(°C)25.3

Humidity

(%RH)

Test Result

CCT (K) CRI Duv

63.6 0.996

The voltage of an AC power supply (RMS voltage) or DC power supply (instantaneous voltage)

applied to the device under test shall be regulated to within ±0.2 percent under load.

The sample was measured using 4π geometry and operated at rated voltage and was stabilized

before measurement. Chromaticity coordinates, correlated color temperature and color rendering

index were calculated from the spectral radiant flux measurements taken at 1 nm intervals over

the range of 380 to 780 nm.

Test Result

Doc No.: DLFLAB-ZY-01-28 Version:1.0 Page 4 of 23

Page 5: Photometric Test Report - RAB Lighting

4.1 Integrating Sphere Test

Doc No.: DLFLAB-ZY-01-28 Version:1.0 Page 5 of 23

Page 6: Photometric Test Report - RAB Lighting

4.1 Integrating Sphere Test

x

y

u ' R a 72

v ' R 9 -33

(CRI)

Colors are for visual orientation purposes only. Created with the ANSI/IES TM-30-18 Calculator Version 2.00.

0.3537

0.3706

0.2100

0.4949

This is a recommended method fordisplaying ANSI/IES TM-30-18information.

Notes:CIE 13.3-1995

0

10

20

30

40

50

60

70

80

90

100

CES

01C

ES03

CES

05C

ES07

CES

09C

ES11

CES

13C

ES15

CES

17C

ES19

CES

21C

ES23

CES

25C

ES27

CES

29C

ES31

CES

33C

ES35

CES

37C

ES39

CES

41C

ES43

CES

45C

ES47

CES

49C

ES51

CES

53C

ES55

CES

57C

ES59

CES

61C

ES63

CES

65C

ES67

CES

69C

ES71

CES

73C

ES75

CES

77C

ES79

CES

81C

ES83

CES

85C

ES87

CES

89C

ES91

CES

93C

ES95

CES

97C

ES99

Co

lor

Sa

mp

le F

ide

lity

(R

f,C

ESi)

380 430 480 530 580 630 680 730 780

Ra

dia

nt

Po

we

r (E

qu

al L

um

ino

us

Flu

x)

Wavelength (nm)

Reference Test

-0.0

1

0.0

8 0.1

8

0.1

4

0.0

8

-0.0

3

-0.0

7

-0.0

4

0.0

8 0.2

2

0.2

4

0.1

3

-0.0

3

-0.0

9

-0.2

6 -0.1

5

-0.5

-0.4

-0.3

-0.2

-0.1

0.0

0.1

0.2

0.3

0.4

0.5

Loca

l H

ue

Sh

ift

(Rh

s,hj)

6876

65

7884

9085

8176

60 63

7483

7970 70

0102030405060708090

100

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

Loca

l C

olo

r F

ide

lity

(R

f,hj)

Hue-Angle Bin (j)

-18

%

-13

% -7%

1% 4%

4%

-6%

-11

%

-16

%

-11

%

0%

7% 1

2%

7%

4%

-10

%

-40%

-30%

-20%

-10%

0%

10%

20%

30%

40%

Loca

l C

hro

ma

Sh

ift

(Rcs

,hj)

-20%

20%

1

2

3

45

16

6

7

8

9

10 15

11

12 13

14 Duv

75

CCT

91

0.0060

RgRf

4767 K

Doc No.: DLFLAB-ZY-01-28 Version:1.0 Page 6 of 23

Page 7: Photometric Test Report - RAB Lighting

ConditionVoltage

(Vac)

Frequency

(Hz)

Current

(A)Power (W)

Power

Factor

WORST

CASE480.01 60 0.133 63.6 0.995

C0-180 C90-270 C0-180 C90-270

7658 232.3 231.7 164.1 163.1 120.3

Opreate time

(Min.)90

Stabilization time

(Min.)

4.0 LM-79 Measurement and Test Results

4.2 Goniophotometer Test

AF1Model No. IVGT5CU-70L750W4 Sample ID.

Test Method

Temperature

(°C)25.3

The samples were tested according to the IES LM-79-2008.

Humidity

(%RH)

45

54.0

Photometric paramters were measured using a type C goniophotometer and software.

Test Result

The ambient temperature shall be maintained at 25° C ± 1° C, measured at a point not more than 1

m from the sample and at the same height as the sample.

The voltage of an AC power supply (RMS voltage)or DC power supply (instantaneous voltage)

applied to the device under test shall be regulated to within ±0.2 percent under load.

Test Conditions

The samples were operated at rated voltage and was stabilized before measurement. Luminous

flux, luminaire efficacy, zonal lumen were calculated from the software taken at 0.5o vertical

intervals and 10o horizontal intervals.

Zonal Lumen

Requirement

(70°-80°)

15.73%

Flux

(lm)

Field Angle(10%) Beam Angle(50%)

BUG rating

B3-U3-G2

Zonal Lumen

Requirement

(60°-80°)

37.99%

Luminous

Efficacy

(lm/W)

Doc No.: DLFLAB-ZY-01-28 Version:1.0 Page 7 of 23

Page 8: Photometric Test Report - RAB Lighting

Light Distrubtion Curve

Isolux Plot

4.2 Goniophotometer Test

Doc No.: DLFLAB-ZY-01-28 Version:1.0 Page 8 of 23

Page 9: Photometric Test Report - RAB Lighting

Zonal Lumen Summary

Zonal (lm) Total (lm) Percent

101.46 0 - 10 101.46 1.32%

301.95 0 - 20 403.41 5.27%

489.53 0 - 30 892.94 11.66%

700.73 0 - 40 1593.67 20.81%

1031.51 0 - 50 2625.18 34.28%

1452.46 0 - 60 4077.64 53.25%

1704.02 0 - 70 5781.66 75.50%

1204.88 0 - 80 6986.54 91.24%

322.46 0 - 90 7309.00 95.45%

16.40 0 - 100 7325.40 95.66%

89.86 0 - 110 7415.26 96.83%

104.16 0 - 120 7519.42 98.19%

51.13 0 - 130 7570.55 98.86%

39.49 0 - 140 7610.04 99.38%

25.05 0 - 150 7635.09 99.70%

14.03 0 - 160 7649.12 99.89%

7.06 0 - 170 7656.18 99.98%

1.56 0 - 180 7657.74 100.00%170-180

90-100

100-110

110-120

120-130

130-140

70-80

80-90

140-150

150-160

160-170

50-60

60-70

4.2 Goniophotometer Test

0-10

10-20

20-30

30-40

40-50

Doc No.: DLFLAB-ZY-01-28 Version:1.0 Page 9 of 23

Page 10: Photometric Test Report - RAB Lighting

LCS/BUG

4.2 Goniophotometer Test

Doc No.: DLFLAB-ZY-01-28 Version:1.0 Page 10 of 23

Page 11: Photometric Test Report - RAB Lighting

Coefficients of Utilization

Isolines

Doc No.: DLFLAB-ZY-01-28 Version:1.0 Page 11 of 23

Page 12: Photometric Test Report - RAB Lighting

Doc No.: DLFLAB-ZY-01-28 Version:1.0 Page 12 of 23

Page 13: Photometric Test Report - RAB Lighting

Doc No.: DLFLAB-ZY-01-28 Version:1.0 Page 13 of 23

Page 14: Photometric Test Report - RAB Lighting

Doc No.: DLFLAB-ZY-01-28 Version:1.0 Page 14 of 23

Page 15: Photometric Test Report - RAB Lighting

Doc No.: DLFLAB-ZY-01-28 Version:1.0 Page 15 of 23

Page 16: Photometric Test Report - RAB Lighting

Doc No.: DLFLAB-ZY-01-28 Version:1.0 Page 16 of 23

Page 17: Photometric Test Report - RAB Lighting

Doc No.: DLFLAB-ZY-01-28 Version:1.0 Page 17 of 23

Page 18: Photometric Test Report - RAB Lighting

Doc No.: DLFLAB-ZY-01-28 Version:1.0 Page 18 of 23

Page 19: Photometric Test Report - RAB Lighting

Doc No.: DLFLAB-ZY-01-28 Version:1.0 Page 19 of 23

Page 20: Photometric Test Report - RAB Lighting

Doc No.: DLFLAB-ZY-01-28 Version:1.0 Page 20 of 23

Page 21: Photometric Test Report - RAB Lighting

Doc No.: DLFLAB-ZY-01-28 Version:1.0 Page 21 of 23

Page 22: Photometric Test Report - RAB Lighting

4.0 LM-79 Measurement and Test Results

4.3 THD and PF Test

Model No.IVGT5CU-

70L750W4Sample ID. AF1

25.3Humidity

(%RH)56.0

Test Method

The samples were tested according to the ANSI C82.77:2002.

Temperature

(°C)

The total harmonic distortion shall be measured to the 40th order.

The ambient temperature condition was maintained at 25º C ± 1º C. The sample measurements

were made using a digital power meter and power supply. The sample was operated at rated

voltage and was stabilized before measurement. The total harmonic distortion were calculated.

Test Results

Voltage

(Vac)

Frequency

(Hz)Current (A) Power (W) Power Factor THD

8.06%480.00 60 0.133 63.6 0.996

Doc No.: DLFLAB-ZY-01-28 Version:1.0 Page 22 of 23

Page 23: Photometric Test Report - RAB Lighting

Equipment IDLast Calibration

Date

Calibration Due

Date

DLF107 2020/12/26 2021/12/25

DLF108 2020/12/26 2021/12/25

DLF122 2020/12/26 2021/12/25

DLF116 2020/12/26 2021/12/25

DLF113 2020/12/26 2021/12/25

DLF112 2020/12/26 2021/12/25

DLF114 2020/12/26 2021/12/25

DLF101 2020/12/26 2021/12/25

DLF125 2020/12/26 2021/12/25

DLF104 2020/12/26 2021/12/25

DLF507 2020/12/26 2021/12/25

DLF102 2020/12/26 2021/12/25

DLF111 2020/12/26 2021/12/25

DLF119 2020/12/26 2021/12/25

DLF031 2020/12/26 2021/12/25

DLF022 2020/12/26 2021/12/25

DLF003 2020/12/26 2021/12/25

Temperature & Humidity Datalogger

Temperature Recorder

5.0 Equipment Information

Measurement Standard Lamp

Standard Lamp Type: 220 V, 0.4720 A,

Tungsten, Omni-derectional

AC Power Source

Power Meter

Auxiliary Lamp

Test Equipment

Equipment Name

Integrating Sphere System

*************** End of Test Report******************

Temperature data logger

Digital power meter

Temperature & Humidity Datalogger

Goniophotometer

Standard Lamp

Standard Lamp Type: 76.58 V, 6.7875 A,

Tungsten, Omni-derectional

AC Power Source

DC Power Source

Power Meter

Temperature & Humidity Datalogger

Power Meter

Doc No.: DLFLAB-ZY-01-28 Version:1.0 Page 23 of 23