PROFINET Network Diagnostics at Audi Neckarsulm, Germany Bernd Kremer, Softing Industrial Automation PI UK Conference 23/24 June 2015 The Stratford Manor Hotel Photo: Audi AG
15

Photo: Audi AG PROFINET Network Diagnostics at Audi ... · 2012 initial contact with Softing / Trebing + Himstedt IC (at first “Body Shop Production Planning” only) Test phase

Jun 25, 2020

Download

Documents

dariahiddleston
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Photo: Audi AG PROFINET Network Diagnostics at Audi ... · 2012 initial contact with Softing / Trebing + Himstedt IC (at first “Body Shop Production Planning” only) Test phase

PROFINET Network Diagnostics at Audi Neckarsulm, Germany

Bernd Kremer, Softing Industrial Automation

PI UK Conference 23/24 June 2015

The Stratford Manor Hotel

Photo: Audi AG

Page 2: Photo: Audi AG PROFINET Network Diagnostics at Audi ... · 2012 initial contact with Softing / Trebing + Himstedt IC (at first “Body Shop Production Planning” only) Test phase

© Softing 2014 / Page 2 of 20

PROFINET and German Automobile Industry

About Audi

PROFINET at Audi Neckarsulm

Network Diagnostics Requirements at Audi

About the Solution

Résumé

Page 3: Photo: Audi AG PROFINET Network Diagnostics at Audi ... · 2012 initial contact with Softing / Trebing + Himstedt IC (at first “Body Shop Production Planning” only) Test phase

© Softing 2014 / Page 3 of 20

PROFINET and German Automobile Industry

AIDA - Automation Initiative of

German Car Manufacturers

► Founded 2003

► Development of mutual positions on automation topics

(e.g. harmonization / standardization of technologies)

► 2004 decision for using PROFINET

► Setting requirements for every PROFINET component

being used in Automotive production

– Integrated safety (PROFIsafe)

– CC B (RT) or CC C (IRT)

– Fast Start-Up (FSU)

– Media redundancy

– PI-Certification

Support of network management services

PROFINET and standard Ethernet through

common port

Connectivity via copper as well as fiber optics

Integrated switch for line and ring topologies

Photo: Shutterstock

Page 4: Photo: Audi AG PROFINET Network Diagnostics at Audi ... · 2012 initial contact with Softing / Trebing + Himstedt IC (at first “Body Shop Production Planning” only) Test phase

© Softing 2014 / Page 4 of 20

About Audi

Facts and Figures

► Member of Volkswagen (VW) Group

► More then 73,000 employees

► Over 1,5 million cars sold (49 models)

► #1 sales position with Premium Cars

in Europe and China

► 2 digit growth in main export markets

USA, China and Great Britain

► 11 Production Sites

► Ingolstadt and Neckarsulm responsible for installation of production

lines at other sites

► „one name, one standard, everywhere“

Photo: Audi AG

Page 5: Photo: Audi AG PROFINET Network Diagnostics at Audi ... · 2012 initial contact with Softing / Trebing + Himstedt IC (at first “Body Shop Production Planning” only) Test phase

© Softing 2014 / Page 5 of 20

About Audi

Neckarsulm Plant

► More then 15,000 employees

► Over 275,000 built

► 1st place J.D. Power Award for best assembly quality

in Europe and Africa

► Site with broadest product variety

(19 models)

► 10.8 Million ft2 production floor space

New pressing plant

One aluminum-steel frame and body construction facility

Two pure aluminum frame and body construction facilities

One paint spray line

Multiple assembly lines

► Lead for production sites

Changchun and Foshan, China

Aurangabad, India

Lamborghini, Italy

Photos: Audi AG

Page 6: Photo: Audi AG PROFINET Network Diagnostics at Audi ... · 2012 initial contact with Softing / Trebing + Himstedt IC (at first “Body Shop Production Planning” only) Test phase

© Softing 2014 / Page 6 of 20

PROFINET at Audi Neckarsulm

Network Composition

► First PROFINET installations proving high speed

communication capabilities and robustness in 2006

(A8 Project)

► 1 GBit/s Uplink from Network Cabinet to Access Switch

► Network structure laid-out for up to 8 cells

► Cells based on PROFINET with some Ethernet

components

► Cu-wiring of Facility and Cell networks with PROFINET

Type B cables only

► Field installations of cells (CC-C / IRT) as redundant

POF-rings

– Max. 40ea subscribers plus max. 10ea on branches

– Exceeding subscribers as extra ring on additional

IRT-switch

► Each cell as own Class C network (256 IP-Addresses)

► One network diagnostics interface TH LINK PROFINET

per cell (own IP-address)

Graphics: Audi AG

Page 7: Photo: Audi AG PROFINET Network Diagnostics at Audi ... · 2012 initial contact with Softing / Trebing + Himstedt IC (at first “Body Shop Production Planning” only) Test phase

© Softing 2014 / Page 7 of 20

Network Diagnostics Requirements at Audi

Body Shop Production Planning

► Tool for effective and efficient support of

installation quality assurance,

plant asset management ,

and maintenance across

entire lifecycle of the facility

► Automation network diagnostics must:

cover all subscribers (PROFINET and standard Ethernet)

– summarize from entire network all information about:

– diagnostics,

– system, and

– devices including

– their individual diagnostics history

be suitable to support through facility lifecycle at:

– installation,

– commissioning,

– acceptance, and

– maintenance

offer report functionality incl. comparison with previous status

provide continuous monitoring capabilities

support SNMP (IT acceptance) Photos: Audi AG

Page 8: Photo: Audi AG PROFINET Network Diagnostics at Audi ... · 2012 initial contact with Softing / Trebing + Himstedt IC (at first “Body Shop Production Planning” only) Test phase

© Softing 2014 / Page 8 of 20

Network Diagnostics Requirements at Audi

Final Assembly

► Tool for effective and efficient support of

network management,

maintenance, and trouble shooting

► PROFINET diagnostics and monitoring tool must:

fit in flow of work

relieve maintenance resources

work independent from brand of network components

offer hot plug-in without PLC project modification

provide little hardware footprint for cabinet installation

not require any additional components, e.g. data base PC

provide functionality offering:

– topology discovery,

– different breakup views,

– inventory information about components

– detection of sporadic failures

Photos: Audi AG

Page 9: Photo: Audi AG PROFINET Network Diagnostics at Audi ... · 2012 initial contact with Softing / Trebing + Himstedt IC (at first “Body Shop Production Planning” only) Test phase

© Softing 2014 / Page 9 of 20

About the Solution

Three interlocking Components

► Network monitoring and analyzing software (TH SCOPE)

– Consolidation of data from all TH Links

– Network overview and topology information in different views

– Network statistics and history of network quality

– Status and bandwidth information for network infrastructure

– Inventory list with related network and device details, such as device type,

firmware version and, IP configuration

– Detailed information about communication failures

– Generation of reports respectively acceptance protocols

– Comparison with filed reference measurements (previous status)

– Data export functionality (e.g. Reference Measuring, Inventory List)

– Web Server

– SNMP agent for handing over diagnostics information from automation networks to IT

with central network monitoring

► Network diagnostic hardware interface (TH LINK PROFINET)

– Network access

– Monitoring communication and device status

– Passive “listening” and active communication (PROFINET, Ethernet)

– Data collection for processing through specific diagnostics algorithm

► Training

– 1 day, regularly performed at customer´s site

– Content (Ethernet, PROFINET) and methodology (hands-on) defined jointly with customer

Page 10: Photo: Audi AG PROFINET Network Diagnostics at Audi ... · 2012 initial contact with Softing / Trebing + Himstedt IC (at first “Body Shop Production Planning” only) Test phase

© Softing 2014 / Page 10 of 20

About the Solution

Protocols and Services used for the

Diagnostics Algorithm

Device Detection

&

Device Identification

Device Diagnostics

&

Network Statistics

Configuration

&

Communication

Failures

Network

Topology

PROFINET

(Communication & Services) X X X X

PROFINET Diagnostics Services X X

ARP (Address Resolution Protocol) X X

Ping X X

SNMP X X X

DCP / DHCP X X

LLDP X X

Page 11: Photo: Audi AG PROFINET Network Diagnostics at Audi ... · 2012 initial contact with Softing / Trebing + Himstedt IC (at first “Body Shop Production Planning” only) Test phase

© Softing 2014 / Page 11 of 20

About the Solution

Outcome

► All network diagnostics requirements of customer met

► Solution specified for all future body-shop facility projects

managed / coached by Audi Neckarsulm

► Step by step integration into existing assembly lines

► Solution provides:

– Maximized availability of all facilities

– High use efficiency through consistent user interface

( one solution / tool for multiple maintenance tasks)

– Assurance of consistently high communication quality

– Hot plug-in capability

– Independence from availability of IT department capacities

Photo: Audi AG

Page 12: Photo: Audi AG PROFINET Network Diagnostics at Audi ... · 2012 initial contact with Softing / Trebing + Himstedt IC (at first “Body Shop Production Planning” only) Test phase

© Softing 2014 / Page 12 of 20

About the Solution

Course of Project

► 2012 initial contact with Softing / Trebing + Himstedt IC

(at first “Body Shop Production Planning” only)

► Test phase for target-performance comparison bringing up

differing and additional mandatory requirements, e.g.:

– Acceptance Report

– Usability (e.g. sequence of work)

– Topology views at different detail levels

► Realization of enhancements and changes with standard products

► 2013 Acceptance

► 2014 first deliveries

► 2015 Equipment of assembly lines for three models and new

body shop facilities

► …

Photo: iStock

Page 13: Photo: Audi AG PROFINET Network Diagnostics at Audi ... · 2012 initial contact with Softing / Trebing + Himstedt IC (at first “Body Shop Production Planning” only) Test phase

© Softing 2014 / Page 13 of 20

Roundup

Conclusions

► Ethernet-based industrial communication offers the opportunity for

realizing networks utilizing multiple technologies in parallel

► Existing requirement for dedicated network diagnostics tools

► PROFINET leveraging numerous standard Ethernet technologies

and protocols hence provides the prerequisite condition for a

consistent hence beneficial network diagnostics of real life industrial

Ethernet installations

► PROFINET is providing the functionality for highly effective and

efficient network management and maintenance meeting the

challenging demands of a leading premium car manufacturer

OSI-Layer PROFINET

7a Application

IO Services & Protocols

7b RPC

6 Presentation --

5 Session

4 Transport UDP

3 Network IP, ARP, SNMP, DHCP

2 Data Link CSMA/CD, VLAN, DCP, MRP, MRRT, LLDP

1 Physical 100BASE-TX, 100BASE-FX

Photos: Audi AG

Page 14: Photo: Audi AG PROFINET Network Diagnostics at Audi ... · 2012 initial contact with Softing / Trebing + Himstedt IC (at first “Body Shop Production Planning” only) Test phase

© Softing 2014 / Page 14 of 20

About Softing Industrial

Competence in Industrial Communication

► 35 years of experience in industrial communication between

devices, controllers and host systems based on international

standards

► Integration of fieldbus technologies, industrial Ethernet and OPC

for Factory and Process Automation

► Ready to use hardware and software products for data integration,

network diagnostics and Plant Asset Management

► Effective May 1st, 2014 Softing Industrial took over the Industrial

Communication business of Trebing + Himstedt including the

solution presented

Photos: Shutterstock

Page 15: Photo: Audi AG PROFINET Network Diagnostics at Audi ... · 2012 initial contact with Softing / Trebing + Himstedt IC (at first “Body Shop Production Planning” only) Test phase

© Softing 2014 / Page 15 of 20

Thank you very much!

Bernd Kremer

Head of Channel Sales International

Softing Industrial Automation GmbH

+49 172 93 99 808

[email protected]