Top Banner
Mini Heatless Desiccant Pneumatech Pride Pneumatech is proud to offer this range of reliable Mini Heatless Desiccant dryers. These dryers are a cost effective solution to re- move moisture and the resultant corrosion from your compressed air system. See your local Pneumatech distributor, visit our website at www.pneumatech.com or give us a call at +1-800-336-2285, we are here to help. PHM-5 to PHM-50 Features Benefits Traditional twin tower design Easy to remove and replace desiccant, compact design Solenoid operated inlet and purge valves No inlet shuttle valve, only positive switching inlet valves -40°F pressure dewpoint meets most dry air needs, -80°F option available All pneumatic sequence operation & other voltage options available. Provides application flexibility Pressure drop 3 PSlD or less Energy Efficient design cULus 508a Industrial Control Panel and NEMA 4 enclosure Installation in all municipalities Wall mount or table mount Provides application flexibility
2

PHM-5 to PHM-50 - Pneumatech...PHM-5 0.7 0.25” 16 x 7 x 24 60 PHM-10 1.4 0.50” 22 x 11 x 37 107 PHM-15 2.1 0.50” 22 x 12 x 37 116 PHM-25 3.5 0.50” 22 x 12 x 37 130 PHM-35 4.9

Oct 16, 2020

Download

Documents

dariahiddleston
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: PHM-5 to PHM-50 - Pneumatech...PHM-5 0.7 0.25” 16 x 7 x 24 60 PHM-10 1.4 0.50” 22 x 11 x 37 107 PHM-15 2.1 0.50” 22 x 12 x 37 116 PHM-25 3.5 0.50” 22 x 12 x 37 130 PHM-35 4.9

Mini HeatlessDesiccant

Pneumatech Pride

Pneumatech is proud to offer this range of reliable Mini Heatless

Desiccant dryers. These dryers are a cost effective solution to re-

move moisture and the resultant corrosion from your compressed

air system.

See your local Pneumatech distributor, visit our website at

www.pneumatech.com or give us a call at +1-800-336-2285,

we are here to help.

PHM-5 to PHM-50

Features Benefits Traditional twin tower design Easy to remove and replace desiccant, compact design

Solenoid operated inlet and purge valves No inlet shuttle valve, only positive switching inlet valves

-40°F pressure dewpoint meets most dry air needs, -80°F option available

All pneumatic sequence operation & other voltage options available. Provides application flexibility

Pressure drop 3 PSlD or less Energy Efficient design

cULus 508a Industrial Control Panel and NEMA 4 enclosure Installation in all municipalities

Wall mount or table mount Provides application flexibility

Page 2: PHM-5 to PHM-50 - Pneumatech...PHM-5 0.7 0.25” 16 x 7 x 24 60 PHM-10 1.4 0.50” 22 x 11 x 37 107 PHM-15 2.1 0.50” 22 x 12 x 37 116 PHM-25 3.5 0.50” 22 x 12 x 37 130 PHM-35 4.9

Technical data

Pneumatech

1800 Overview Drive

Rock Hill, SC 29730 USA

1-800-336-2285

www.pneumatech.com

Pneumatech reserves the right to change or revise specifications and product design in connection with any

features of our products. Such changes do not entitle the buyer to corresponding changes, improvements,

additions or replacements for equipment previously sold or shipped.

© 2014 Pneumatech. All rights reserved.

Use of this Motor Challenge logo does not imply DOE endorsement.

ModelNumber* Purge Flow In/Out

Conn. Size [NPT]Dimensions

L x W x H (in)Approx Shipping

Weight (lbs)

PHM-5 0.7 0.25” 16 x 7 x 24 60

PHM-10 1.4 0.50” 22 x 11 x 37 107

PHM-15 2.1 0.50” 22 x 12 x 37 116

PHM-25 3.5 0.50” 22 x 12 x 37 130

PHM-35 4.9 0.50” 22 x 12 x 39 150

PHM-50 7.0 0.50” 22 x 12 x 49 170

*scfm flow at 100°F inlet, 100 psig inlet and 100°F ambient temperature.

H

LW

Unit shown with filters mounted (Optional)

Operating Specifications:

Recommended Installation:

Oil will contaminate the adsorbent material, making it ineffective for water vapor removal. A Pneumatech oil coalescingpre-filter must be installed before the dryer. Additionally, a Pneumatech particulate after-filter is also required for proper particulate and desiccant dust removal after the dryer.

Operating Pressure: 100 PSIG

Operating Temp: 100°F

Max. Inlet Temp: 120°F

Min. Inlet Temp: 70°F

Design Pressure: 150 PSIG

Outlet Dew Point: -40°F

Power Supply: 115-1-60

Electricals: NEMA 4

NEMA Cycle: 10 min.

Desiccant: Activated Alumina