Top Banner
KLAUS DEHMELT FOR THE PHENIX COLLABORATION RHIC & AGS ANNUAL USER’S MEETING JUNE 19, 2014 PHENIX Run 14 Report
28

PHENIX Run 14 Report

Feb 22, 2016

Download

Documents

FERN

PHENIX Run 14 Report. Klaus Dehmelt For the Phenix collaboration Rhic & ags Annual User’s meeting june 19, 2014. PHENIX in Run 14. The PHENIX collaboration requested Au + Au @ 200 GeV for 12 weeks [Physics driven goal is 1.5 nb -1 recorded within |z| < 10 cm] - PowerPoint PPT Presentation
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: PHENIX Run 14 Report

KLAUS DEHMELTFOR THE PHENIX COLLABORATION

RHIC & AGS ANNUAL USER’S MEETINGJUNE 19 , 2014

PHENIX Run 14 Report

Page 2: PHENIX Run 14 Report

Klaus Dehmelt

PHENIX in Run 14

06/19/2014

2

The PHENIX collaboration requested Au + Au @ 200 GeV for 12 weeks

[Physics driven goal is 1.5 nb-1 recorded within |z| < 10 cm]to collect their definitive Heavy Ion Au + Au data sample

Focus on high precision measurements of Heavy Flavor production RAA and v2

for electrons and muons separated charm and bottom decays

Page 3: PHENIX Run 14 Report

Klaus Dehmelt

Heavy Quarks with PHENIX

06/19/2014

3

F/VTX detectors Tracking resolution better than 50 mm Vertex resolution better than 100 mm

D Au

e,m

AuD

X

J/

B

X

K

e

() → 312 mm (u) → 491 mm (c) → 123 mm () → 457 mm

DCA

AuAuD

B

e

e

Page 4: PHENIX Run 14 Report

Klaus Dehmelt

FVTX Data Set

06/19/2014

4

First Au+Au dataset for FVTXSimulation performance of nuclear

modification factor RAA

DGLV Additional collisional

dissociation processes

Page 5: PHENIX Run 14 Report

Klaus Dehmelt

VTX Data Set

06/19/2014

5

Simulation performance of RAA for VTX-system

CharmBeauty

Very different prediction whenconsidering extreme scenario of

beauty quarks following flow field

Page 6: PHENIX Run 14 Report

Klaus Dehmelt

VTX Data Set

06/19/2014

6

Example full unfolding from DCA electrons to parent mesons

Page 7: PHENIX Run 14 Report

Klaus Dehmelt

PHENIX Detectors

06/19/2014

7

PHENIX in Run 14

Page 8: PHENIX Run 14 Report

Klaus Dehmelt

PHENIX Vertex Detector System

06/19/2014

8

Barrel region |h|<1.2, almost 2 in f Pixel sensors at inner 2 layers Strip sensors at outer 2 layers

Forward region 1.2<|h|<2.7, 2 in f 4 layers of mini strips

(50x 2000 to 11000mm)

Page 9: PHENIX Run 14 Report

Klaus Dehmelt

PHENIX Vertex Detector System

06/19/2014

9

Refurbished Barrel VTX system

Page 10: PHENIX Run 14 Report

Klaus Dehmelt

PHENIX Vertex Detector System

06/19/2014

10

Refurbished Barrel VTX system

Page 11: PHENIX Run 14 Report

Klaus Dehmelt

PHENIX Vertex Detector System

06/19/2014

11

Refurbished Barrel VTX system + FVTX

Page 12: PHENIX Run 14 Report

Klaus Dehmelt

PHENIX Vertex Detector System

06/19/2014

12

Page 13: PHENIX Run 14 Report

Klaus Dehmelt

PHENIX IR

06/19/2014

13

F/VTX system installed in IR

Page 14: PHENIX Run 14 Report

Klaus Dehmelt

PHENIX Counting House

06/19/2014

14

Page 15: PHENIX Run 14 Report

Klaus Dehmelt

Run 14 The Parts

06/19/2014

15

2014 - Run 14 subdivided in

Au+Au at

Au+Au at

Page 16: PHENIX Run 14 Report

Klaus Dehmelt

PHENIX @ 15 GeV

06/19/2014

16

Run 14 Low Energy LE @ 15 GeV Physics declared for PHENIX on February 15 Goal for PHENIX: get detectors fully operational for physics

We have recorded a high quality Au+Au 15 GeV data set and have tested our new detectors in preparation for the 200 GeV run

Estimated number of (real) Au+Au @ 15 GeV events:

~ 15M events in [ 30 cm] (March 10) ℒ ~ 2.5/mb

~ 6.4M events in [ 10 cm] (March 10) ℒ ~ 1.1/mb

Page 17: PHENIX Run 14 Report

Klaus Dehmelt

PHENIX @ 15 GeV

06/19/2014

17

Very first additional distribution for BES energies from a small fraction of complete dataset

Page 18: PHENIX Run 14 Report

Klaus Dehmelt

Run 14 High Energy Run

06/19/2014

18

High energy run Au+Au @ 200 GeV was declared on March 15, about five days after LE run was finished

After 10 days set up B+Y longit. and horiz. cooling

Page 19: PHENIX Run 14 Report

Klaus Dehmelt

RHIC Performance

06/19/2014

19

Excellent RHIC performance Fast tune up, stochastic cooling working quickly Very good lifetime, default store length 10 – 11 hours,

fast turnaround

Page 20: PHENIX Run 14 Report

Klaus Dehmelt

RHIC Performance

06/19/2014

20

Excellent RHIC performance

Page 21: PHENIX Run 14 Report

Klaus Dehmelt

Run 14 High Energy Run

06/19/2014

21

First Physics store/run was 18046/405839, March 15

High Energy (HE) run for 93 days ~13 ½ weeksConcluded HE run with 193 fillsOur main goal for Au+Au @ 200 GeV was to

accumulate ℒ = 1.5 nb-1 for BBC-vertex |z| < 10 cm Optimal range for VTX coverage Accumulated = 2.56 nbℒ -1

171% of our goal Integrated luminosity is based on reconstructed events in

BBC-narrow vertex range

Page 22: PHENIX Run 14 Report

Klaus Dehmelt

PHENIX Performance

06/19/2014

22

Secured luminosity goal on May 14Integrated luminosityℒ = 2.56 nb-1

Corresponds to16.2B events

Recorded>19B events

June 16, 2014

Page 23: PHENIX Run 14 Report

Klaus Dehmelt

PHENIX Performance

06/19/2014

23

~ 1100 hours PHENIX physics runs ~ 1500 hours CAD stores > 80% efficiency

Page 24: PHENIX Run 14 Report

Klaus Dehmelt

PHENIX Detector Performance

06/19/2014

24

F/VTX detectors operating well Live area > 95% Internal alignment

Centroid for wedge residual : σ<3mm Centroid for DCA FVTX track-FVTX vertex within ±50mm

limits

Page 25: PHENIX Run 14 Report

Klaus Dehmelt

PHENIX Detector Performance

06/19/2014

25

F/VTX detectors operating well Successful repair and operation Pixel live area > 80 % Strip pixel live area > 85 %

1.0 GeV/c < pt < 1.5 GeV/c

F/VTX detectors operating well Preliminary alignment provides better than 100 mm

DCA

Page 26: PHENIX Run 14 Report

Klaus Dehmelt

Setting Up for 3He + Au

06/19/2014

26

Unique probe of geometryMake use of large tracking coverage of F/VTXMeasurement if hotspots in deposited energy

connect during time evolution v2 and v3?

Page 27: PHENIX Run 14 Report

Klaus Dehmelt

Setting Up for 3He + Au

06/19/2014

27

First collisions last night (Wednesday, June 19)

Page 28: PHENIX Run 14 Report

Klaus Dehmelt

Conclusion

06/19/2014

28

Run 14 Au+Au part successfully completedDetector is performing wellLuminosity goal early accomplished and well

exceededSuccessful running based on fantastic - RHIC - and - Collaborator - performance Setting up for exciting final measurement with 3He + Au @ 200 GeVExpecting end of run in 2014 by July 10Many thanks to my PHENIX fellows, C-AD members

and STAR crews