www.tridonic.com 1 Subject to change without notice. Data sheet 05/12-952-3 U – LED modules, converters and systems GENERAL ILLUMINATION Product description LED strip module for highlighting lines and edges and for side injection For safety lighting, general lighting, effect lighting and shelf lighting Suitable for uaccessory PROFILE Z200-2 / 201-2 / Z22W-2 Edge injection of transparent or diffuse materials With maximum possible beam angle for uniform illumination Low profile Dimmable by pulse width modulation (PWM) Integrated current source to stabilise luminous flux Attached with premounted thermally conductive double-sided adhesive tape Connection: Cable 200 mm Technical data Beam characteristic 140° Ambient temperature ta -25 ... +50 °C Max. tc point 1 75 °C Risk group (EN 62471:2008) 0 È Colour temperatures and tolerances, page 4 Umodule STRIP P110-3 / 111-3 umodule STRIP 9,5 ±0,4 16,5 1,55 1,45 Ordering data Colour 5 Wavelength Colour temperature 6 Type Article number 10 light points per module Red 619 – 629 nm P110-3 R 89601054 Amber 584 – 594 nm P110-3 A 89601053 12 light points per module Daylight white 6,500 K P111-3 DL 89601044 Neutral white 4,200 K P111-3 NW 89601043 Warm white 3,000 K P111-3 WW 89601042 Gold 2,700 K P111-3 GOLD 89601443 Packed meat P111-3 PM 89601444 Green 520 – 535 nm P111-3 G 89601046 Blue 450 – 460 nm P111-3 B 89601045 Packaging: 10 pieces/carton PHASED OUT
7

PHASED - Tridonic GmbH & Co KG · 2012. 8. 28. · IN-BUILT LCU REMOTE LCU Type 0010 K301 24V 0025 K201 24V 0025 K210 24V one4all 0025 K211 24V LCU 035/24 E020 LCU 060/24 E020 LCU

Mar 28, 2021

Download

Documents

dariahiddleston
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: PHASED - Tridonic GmbH & Co KG · 2012. 8. 28. · IN-BUILT LCU REMOTE LCU Type 0010 K301 24V 0025 K201 24V 0025 K210 24V one4all 0025 K211 24V LCU 035/24 E020 LCU 060/24 E020 LCU

www.tridonic.com 1Subject to change without notice.

Data sheet 05/12-952-3

U – LED modules, converters and systemsGENERAL ILLUMINATION

Product description

•LED strip module for highlighting lines and edges

and for side injection

•For safety lighting, general lighting, effect lighting and shelf lighting

•Suitable for uaccessory PROFILE Z200-2 / 201-2 / Z22W-2

•Edge injection of transparent or diffuse materials

•With maximum possible beam angle for uniform illumination

•Low profile

•Dimmable by pulse width modulation (PWM)

• Integrated current source to stabilise luminous flux

•Attached with premounted thermally conductive

double-sided adhesive tape

•Connection: Cable 200 mm

Technical dataBeam characteristic 140°

Ambient temperature ta -25 ... +50 °C

Max. tc point1 75 °C

Risk group (EN 62471:2008) 0

ÈColour temperatures and tolerances, page 4

Umodule STRIP P110-3 / 111-3umodule STRIP

9,5

±0,

4

16,5

1,55

1,45

Ordering data

Colour5 WavelengthColourtemperature6 Type Article number

10 light points per module

Red 619 – 629 nm – P110-3 R 89601054

Amber 584 – 594 nm – P110-3 A 89601053

12 light points per module

Daylight white – 6,500 K P111-3 DL 89601044

Neutral white – 4,200 K P111-3 NW 89601043

Warm white – 3,000 K P111-3 WW 89601042

Gold – 2,700 K P111-3 GOLD 89601443

Packed meat – – P111-3 PM 89601444

Green 520 – 535 nm – P111-3 G 89601046

Blue 450 – 460 nm – P111-3 B 89601045Packaging: 10 pieces/carton

PHASED

OUT

Page 2: PHASED - Tridonic GmbH & Co KG · 2012. 8. 28. · IN-BUILT LCU REMOTE LCU Type 0010 K301 24V 0025 K201 24V 0025 K210 24V one4all 0025 K211 24V LCU 035/24 E020 LCU 060/24 E020 LCU

www.tridonic.com 2Subject to change without notice.

Data sheet 05/12-952-3

U – LED modules, converters and systemsGENERAL ILLUMINATION

Specific technical dataType Typ. luminous flux2 4 Supply voltage DC3 Power2 Colour rendering index CRI6 Total length

10 light points per moduleP110-3 R 54 lm 24 V 1.3 W – 195 +/- 0.4 mm

P110-3 A 62 lm 24 V 1.3 W – 195 +/- 0.4 mm

12 light points per moduleP111-3 DL 106 lm 24 V 1.8 W 70 195 +/- 0.4 mm

P111-3 NW 77 lm 24 V 1.8 W 80 195 +/- 0.4 mm

P111-3 WW 68 lm 24 V 1.8 W 80 195 +/- 0.4 mm

P111-3 GOLD 47 lm 24 V 1.8 W > 90 195 +/- 0.4 mm

P111-3 PM 55 lm 24 V 1.8 W 80 195 +/- 0.4 mm

P111-3 G 41 lm 24 V 1.8 W – 195 +/- 0.4 mm

P111-3 B 24 lm 24 V 1.8 W – 195 +/- 0.4 mm1 If the max. temperature limits are exceeded, the life of the module will be reduced or the module may be damaged. The temperature

of the umodule STRIP at the tc-point is to be measured in the thermally stable state. For tc-point see the above diagram.

2 Tolerance range for optical and electrical data: ±15 %

3 Exceeding the max. operating voltage leads to an overload on the umodule STRIP. This may in turn result in a significantreduction in lifetime or even in destruction. Tolerance range for the supply voltage: 24 V: +2 V / -0 V

4 At tc = 45 °C

5 Colour coordinates and tolerances according to CIE 1964.

6 Colour temperature and CRI according to CIE 1931.

All values at ta = 25 °C.

PHASED

OUT

Page 3: PHASED - Tridonic GmbH & Co KG · 2012. 8. 28. · IN-BUILT LCU REMOTE LCU Type 0010 K301 24V 0025 K201 24V 0025 K210 24V one4all 0025 K211 24V LCU 035/24 E020 LCU 060/24 E020 LCU

www.tridonic.com 3Subject to change without notice.

Data sheet 05/12-952-3

U – LED modules, converters and systemsGENERAL ILLUMINATION

Controls-Matrix – Umodule STRIP P110-3 / P111-3

REMOTE IN-BUILT

Type C001 C002 C004 C003 DALI RGB

Article number 86454974 86454968 24138760 86457912

Assignable controls Assignable controls

Type Article number Min. Max. Min. Max. Min. Max. Min. Max.

Umodule STRIP P110-3 R 89601054 1 80 1 80 1 80 1 20

Umodule STRIP P110-3 A 89601053 1 80 1 80 1 80 1 20

Umodule STRIP P111-3 DL 89601044 1 80 1 80 1 80 1 20

Umodule STRIP P111-3 NW 89601043 1 80 1 80 1 80 1 20

Umodule STRIP P111-3 WW 89601042 1 80 1 80 1 80 1 20

Umodule STRIP P111-3 GOLD 89601444 1 80 1 80 1 80 1 20

Umodule STRIP P111-3 PM 89601443 1 80 1 80 1 80 1 20

Umodule STRIP P111-3 G 89601046 1 80 1 80 1 80 1 20

Umodule STRIP P111-3 B 89601045 1 80 1 80 1 80 1 20

Converter matrix – Umodule STRIP P110-3 / P111-3

IN-BUILT LCU REMOTE LCU

Type0010 K301

24V0025 K201

24V0025 K21024V one4all

0025 K21124V

LCU 035/24 E020

LCU 060/24 E020

LCU 100/24 E020

LCU 150/24 E020

Article number 86456215 86453418 86455937 86455066 24166320 24166324 24166328 24166333

Assignable converter Assignable converter

Max. chainingType Article number Min. Max. Min. Max. Min. Max. Min. Max. Min. Max. Min. Max. Min. Max. Min. Max.

Umodule STRIP P110-3 R 89601054 1 6 1 12 1 12 1 12 1 17 x x x x x x 20

Umodule STRIP P110-3 A 89601053 1 6 1 12 1 12 1 12 1 17 x x x x x x 20

Umodule STRIP P111-3 DL 89601044 1 6 1 12 1 12 1 12 1 17 x x x x x x 20

Umodule STRIP P111-3 NW 89601043 1 6 1 12 1 12 1 12 1 17 x x x x x x 20

Umodule STRIP P111-3 WW 89601042 1 6 1 12 1 12 1 12 1 17 x x x x x x 20

Umodule STRIP P111-3 GOLD 89601444 1 6 1 12 1 12 1 12 1 17 x x x x x x 20

Umodule STRIP P111-3 PM 89601443 1 6 1 12 1 12 1 12 1 17 x x x x x x 20

Umodule STRIP P111-3 G 89601046 1 6 1 12 1 12 1 12 1 17 x x x x x x 20

Umodule STRIP P111-3 B 89601045 1 6 1 12 1 12 1 12 1 17 x x x x x x 20

PHASED

OUT

Page 4: PHASED - Tridonic GmbH & Co KG · 2012. 8. 28. · IN-BUILT LCU REMOTE LCU Type 0010 K301 24V 0025 K201 24V 0025 K210 24V one4all 0025 K211 24V LCU 035/24 E020 LCU 060/24 E020 LCU

www.tridonic.com 4Subject to change without notice.

Data sheet 05/12-952-3

U – LED modules, converters and systemsGENERAL ILLUMINATION

WiringCable: AWG24; length 200 mm

Colour red blackFunction + –

Electrical supply/choice of converter

umodule STRIP from Tridonic is not protected against overvoltages, overcur-rents, overloads or short-circuit currents. Safe and reliable operation can only be guaranteed in conjunction with a converter which complies with the relevant standards. The use of u converters from Tridonic in combination with umodule STRIP guarantees the necessary protection for safe and reliable operation. The umodule STRIP is only for the operation with SELV < 60 V. The operation at converters with output voltage > 60 V is with an additional preparations possible. Further information on request.

If a converter other than Tridonic uconverter is used, it must provide the following protection:

•Short-circuitprotection•Overloadprotection

umodule STRIP P110-3 / P111-3 must be supplied by a constant voltage converter.Operation with a constant current converter will lead to an irreversible damage of the module. Reversed polarity can damage the umodule STRIP P110-3 / P111-3.

EOS/ESD safety guidelines

The device / module contains components that are sensitive to electro-static discharge and may only be installed in the factory and on site if appropriate EOS/ESD protection measures have been taken. No special measures need be taken for devices/modules with enclosed casings (contact with the pc board not possible), just normal installation prac-tice. Please note the requirements set out in the document EOS / ESD guidelines (Guideline_EOS_ESD.pdf) at: http://www.tridonic.com/com/en/technical-docs.asp

Mounting instruction

umodule EOS from Tridonic which have to be installed on a heat sink are equipped as standard with thermally conductive adhesive tape on the back of the pc board.

These u products must be installed with this adhesive tape. To ensure permanent adhesion the fixing/cooling surface must be cleaned before installing the u modules to remove all dirt, dust and grease.

The contact adhesion surface must have a surface energy of at least 38 mNm. The contact pressure must be at least 10 kg/cm² (ideally: 40 kg/cm²) for at least 3 seconds.Processing must take place at an ambient temperature of 23 +/- 5°C.A dwell time of 24 hours is required after adhesion. To avoid damaging the modules during processing you must not touch the components or the glob top. A suitable tool must be used.

For more information please call or email your Tridonic contact.

PHASED

OUT

Page 5: PHASED - Tridonic GmbH & Co KG · 2012. 8. 28. · IN-BUILT LCU REMOTE LCU Type 0010 K301 24V 0025 K201 24V 0025 K210 24V one4all 0025 K211 24V LCU 035/24 E020 LCU 060/24 E020 LCU

www.tridonic.com 5Subject to change without notice.

Data sheet 05/12-952-3

U – LED modules, converters and systemsGENERAL ILLUMINATION

20

20

-20 40

40

60

60

80

100

80 100-40-60-80-100

10°-10°20°-20°

-30°

-40°

-50°

-60°

30°

40°

50°

60°

70°

80°

90°00re

lativ

e lu

min

ous

inte

nsity

Iv/Iv

, max

Light distribution

0

20

40

60

80

100

120

50403020 60 70 80tc in °C

rela

tive

inte

nsity

in %

relative luminous flux vs. tc-Punkt

140

RedAmber

0

20

40

60

80

100

120

50403020 60 70 80tc in °C

rela

tive

inte

nsity

in %

relative luminous flux vs. tc point

140

Warm white, neutral white, daylight white, green, blue

Optical characteristics Umodule STRIP P110-3 / P111-3

The optical design of the umodule STRIP lens system ensures an optimumof homogenity for the light distribution.

The diagrams based on statistic values.The real values can be different.

The evaluation to the eye safety is according to the EN 62471:2008(Photobiological safety of lamps and lamp systems)

Type Articlenumber

Colour Actinic UV near UV blue light retinal thermal IR radiation, eyeES EUVA LB LR EIR

200 – 400 nm 315 – 400 nm 300 – 700 nm 380 – 1,400 nm 780 – 3,000 nmP110-3 A 89601053 Amber exempt exempt exempt exempt exempt

P110-3 R 89601054 Red exempt exempt exempt exempt exemptP111-3 WW 89601042 Warm white exempt exempt exempt exempt exemptP111-3 NW 89601043 Neutral white exempt exempt exempt exempt exemptP111-3 DL 89601044 Daylight white exempt exempt exempt exempt exemptP111-3 G 89601046 Green exempt exempt exempt exempt exemptP111-3 B 89601045 Blue exempt exempt exempt exempt exempt

Exempt:The LED does not pose any photobiological hazard.

Low risk:The LED does not pose a hazard due to normal behavioral limitations on exposure.

Moderate risk:The LED does not pose a hazard due to the aversion response to very bright light sources or due to thermal discomfort.

High risk:The LED may pose a hazard even for momentary or brief exposure.

PHASED

OUT

Page 6: PHASED - Tridonic GmbH & Co KG · 2012. 8. 28. · IN-BUILT LCU REMOTE LCU Type 0010 K301 24V 0025 K201 24V 0025 K210 24V one4all 0025 K211 24V LCU 035/24 E020 LCU 060/24 E020 LCU

www.tridonic.com 6Subject to change without notice.

Data sheet 05/12-952-3

U – LED modules, converters and systemsGENERAL ILLUMINATION

Coordinates and tolerances according to CIE 1964

The specified colour coordinates are measured by a voltage impulse of 24 V and a duration of 100 ms.The ambient temperature of the measurement is ta = 25 °C.

0,3450

0,3500

0,3550

0,3600

0,3650

0,3700

0,3750

0,3800

0,3850

0,35

50

0,36

00

0,36

50

0,37

00

0,37

50

0,38

00

0,38

50

0,39

00

0,39

50

0,3050

0,3100

0,3150

0,3200

0,3250

0,3300

0,3350

0,3400

0,3450

0,30

00

0,30

50

0,31

00

0,31

50

0,32

00

0,32

50

0,33

00

0,33

50

0,34

00

4,200 K

x0 y0

Centre 0.3770 0.3660

MacAdam ellipse: 5SDCM

6,500 K

x0 y0

Centre 0.3200 0.3270

MacAdam ellipse: 5SDCM

MacAdam ellipse: 5SDCM

0,3800

0,3850

0,3900

0,3950

0,4000

0,4050

0,4100

0,4150

0,4200

0,42

50

0,43

00

0,43

50

0,44

00

0,44

50

0,45

00

0,45

50

0,46

00

0,46

50

3,000 Kx0 y0

Centre 0.4460 0.3990

380 420 460 500 540 580 620 660 700 740 780

wave length [nm]

norm

. int

ensi

ty [%

]0

20

40

60

80

100

380 420 460 500 540 580 620 660 700 740 780wave length [nm]

norm

. int

ensi

ty [%

]

0

20

40

60

80

100

380 420 460 500 540 580 620 660 700 740 780wave length [nm]

norm

. int

ensi

ty [%

]

0

20

40

60

80

100PHASED

OUT

Page 7: PHASED - Tridonic GmbH & Co KG · 2012. 8. 28. · IN-BUILT LCU REMOTE LCU Type 0010 K301 24V 0025 K201 24V 0025 K210 24V one4all 0025 K211 24V LCU 035/24 E020 LCU 060/24 E020 LCU

www.tridonic.com 7Subject to change without notice.

Data sheet 05/12-952-3

U – LED modules, converters and systemsGENERAL ILLUMINATION

0,3950

0,4000

0,4050

0,4100

0,4150

0,4200

0,4250

0,4300

0,4350

0,45

00

0,45

50

0,46

00

0,46

50

0,47

00

0,47

50

0,48

00

0,48

50

0,49

00

0,2750

0,2800

0,2850

0,2900

0,2950

0,3000

0,3050

0,3100

0,3150

0,3650

0,3700

0,3750

0,3800

0,3850

0,3900

0,3950

0,4000

0,4050

GOLD

x0 y0

Centre 0.4700 0.4160

MacAdam ellipse: 5SDCM

Packed meat

x0 y0

Centre 0.3827 0.2960

MacAdam ellipse: 5SDCM

380 420 460 500 540 580 620 660 700 740 7800

20

40

60

80

100

wave length [nm]

norm

. int

ensi

ty [%

]

380 420 460 500 540 580 620 660 700 740 7800

20

40

60

80

100

wave length [nm]

norm

. int

ensi

ty [%

]

PHASED

OUT