Phase Technology FPA-70Xi Freeze Point Analyzer. About Phase Technology. Expertise: Design & manufacture of analyzers to test cloud, pour and freeze point Cold Flow is All We Do! Scientific Background: 29 year history of research; 30 patents Market Leader: - PowerPoint PPT Presentation
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Phase Technology FPA-70Xi  Freeze Point Analyzer

Phase Technology FPA-70Xi

Freeze Point Analyzer

Page 2: Phase Technology FPA-70Xi  Freeze Point Analyzer

About Phase Technology

Expertise: Design & manufacture of analyzers to

test cloud, pour and freeze point Cold Flow is All We Do!

Scientific Background: 29 year history of research; 30 patents

Market Leader: 20 years of inter-laboratory “round robin”

research Phase ranks highest for repeatability,

reproducibility, sensitivity and equivalency to reference manual test methods

Page 3: Phase Technology FPA-70Xi  Freeze Point Analyzer

Phase Technology customers

Page 4: Phase Technology FPA-70Xi  Freeze Point Analyzer

Why do more companies in the world choose

Phase Technology analyzers?

Page 5: Phase Technology FPA-70Xi  Freeze Point Analyzer

Companies choose Phase Technology

because:1. World’s best precision

2. World’s fastest test speed

3. World’s most complete set of features and easy-to-use analyzer

Page 6: Phase Technology FPA-70Xi  Freeze Point Analyzer

Phase Technology 70Xi

Page 7: Phase Technology FPA-70Xi  Freeze Point Analyzer

70Xi analyzer benefits

Fastest speed of any automatic or manual method: Average test duration 8 – 10 min Average operator time 0.5 – 2 min

Unsurpassed detection of contamination in jet fuels

Powerful cooling system; minimum sample temperature to below -88°C [-126°F]

Page 8: Phase Technology FPA-70Xi  Freeze Point Analyzer

70Xi productivity features

Fast, one-touch testing press one button to run a test instead of entering

multiple screens of information

Full-color, touch-sensitive, 15” high resolution screen  Easier to read and view more information Displays several views of information at the same

time. Touch sensitive design is faster than keyboard &

mouse.

Easy-to-use interface  New colorful graphic icon buttons for faster

navigation. Intuitive and easy to understand on-screen

prompts.

Page 9: Phase Technology FPA-70Xi  Freeze Point Analyzer

70Xi productivity features

USB and Ethernet connectivity  Quickly export analyzer data to a portable USB

flash drive. Ethernet port available for connecting to LIMS or

internal computer network Import and store any user documents

(.doc, .pdf, .ppt and .pps) for customized operating procedures (SOP) or training

Reliability improvements Modular component design – boards can be easily

replaced in the field; no need to return to Canada for service

More stable cooler Faster multiprocessor

Page 10: Phase Technology FPA-70Xi  Freeze Point Analyzer

70Xi intellinostics

Built-in answers and operator information

Quick, responsive solutions — built-in alert messages give troubleshooting options to quickly solve problems

Self-guided tutorials — easy, on-screen instructions show how to use analyzer

In-depth system diagnostics — system checks verify performance and detect problems with critical components

Page 11: Phase Technology FPA-70Xi  Freeze Point Analyzer

Phase Technology 70Xi

Autosampler System

Page 12: Phase Technology FPA-70Xi  Freeze Point Analyzer

Automatic sampling & cleaning

Set-and-forget convenience set 1 to 48 test runs, then walk away and

let the analyzer do the rest!

Automatic sample injection no need to individually pipette samples or

change pipette tips. Always uses the exact amount of sample

required by the ASTM method.

Self-cleaning Saves time and ensures perfect cleaning

every time. No more need for cotton swabs or risk of

damage to sample cup.

Page 13: Phase Technology FPA-70Xi  Freeze Point Analyzer

70Xi home screen

Page 14: Phase Technology FPA-70Xi  Freeze Point Analyzer

70Xi “Favorites” feature

One-touch preset Favorites  Frequently-used test

settings can be stored in the analyzer for quick access.

Favorites can be created, organized, sorted or deleted as you desire.

With the single push of a button, lab operators can efficiently perform tests in significantly less time

Page 15: Phase Technology FPA-70Xi  Freeze Point Analyzer

Built-in tools to validate test results

Overlay and compare multiple phase plots

Control and trend charts Automatic QC run Option to retest sample Optional alert or lockdown if out of

acceptable limits

Page 16: Phase Technology FPA-70Xi  Freeze Point Analyzer

70Xi control chart – consistent runs

Page 17: Phase Technology FPA-70Xi  Freeze Point Analyzer

70Xi control chart – bad run

Page 18: Phase Technology FPA-70Xi  Freeze Point Analyzer

70Xi plot overlay – consistent runs

Page 19: Phase Technology FPA-70Xi  Freeze Point Analyzer

70Xi plot overlay – bad run

Page 20: Phase Technology FPA-70Xi  Freeze Point Analyzer

On-screen freeze point phase plot

Page 21: Phase Technology FPA-70Xi  Freeze Point Analyzer

Understanding phase plots

Page 22: Phase Technology FPA-70Xi  Freeze Point Analyzer

Phase plot can tell you when there is a problem: example of

contaminated sample with “tail”

Page 23: Phase Technology FPA-70Xi  Freeze Point Analyzer

ASTM Methods Comparison

Page 24: Phase Technology FPA-70Xi  Freeze Point Analyzer

FREEZE POINT ASTM Method Comparison

Phase Technology

70Xi

ISL/PAC FZP52Gs

Manual Method

ASTM Freeze Point Method D5972 D7153 D2386

Repeatability 0.5°C 0.6°C 1.5°C

Reproducibility 0.8°C 0.9°C 2.5°C

Test bias relative to manual methodNo Yes N/A

Full coverage contaminationdetection (ASTM RR-1572)

96% 88% 19%

False warmingNo yes yes

Test duration8 to 10 minutes 15 to 30 minutes 60 to 120 minutes

Temperature range-88°C to +55°C Varies depending

on external bath

Sample volume0.15 ml 10 ml 25 ml

External cooler or bath requiredno no Yes

Page 25: Phase Technology FPA-70Xi  Freeze Point Analyzer

FREEZE POINT ASTM Method Comparison

ISL/PAC takes 2 to 3 times longer to run a freeze point test compared to Phase Technology

ISL/PAC FZP52Gs freeze point analyzer has serious false warming issues• Numerous studies have shown high

incidence of false warming – as high as 60% in a BP study

• Shell Bulletin GLN 33a (September 14, 2006) warned that ISL “can occasionally falsely show a failure if samples contain small amounts of high boiling point material”

Page 26: Phase Technology FPA-70Xi  Freeze Point Analyzer

The Phase Technology ADVANTAGE:

Phase Technology’s 70X analyzer is 4 to 10 times faster than the competition!

Phase Technology’s 70Xi analyzer has the world’s best precision, best detection of contamination, and zero bias!

The PSA-70Xi requires much less sample: 4 to 14 ml less needed per test!

Page 27: Phase Technology FPA-70Xi  Freeze Point Analyzer

The Phase Technology ADVANTAGE:

Phase Technology has the oldest, most established, continuous-in-production automatic cold flow ASTM Methods – 17 years of proven, in-the-field use!

The PSA-70Xi tests pour, cloud and freeze point in one single unit. You’d have to buy two or three separate analyzers from our competitor!

Page 28: Phase Technology FPA-70Xi  Freeze Point Analyzer

Thank you!

For more information:phase-

technology.com