Industrial PFP Premium Stainless Steel Liquid Filled Gauge 42 Tel: 1-800-WINTERS / www.winters.com WINTERS INSTRUMENTS Description & Features: • Liquid filled stainless steel case protects against vibration and pulsation • Bayonet ring • Highly accurate • Back, bottom, or panel mounted • Under and overload stops • Ventable plug on 2.5” to 4.5” stainless steel and 4.5” brass bottom mount and 4” stainless steel back mount • Stainless steel or brass wetted parts • Restrictor screw standard on dual scale (optional on single scale) • Dry case available • ASME B40.100 compliant (EN837-1 available) • CRN registered • 5 year warranty Applications: • Outdoor and severe ambient and process conditions • Use where harmful vibration and pulsation are present • Hydraulic equipment, oil field equipment, pumps, compressors and process industries Note: RoHS applies to SS internals only 1 1. Maximum Indicating Pointer Specifications Stainless Steel Internals Brass Internals Dial 2.5” (63mm), 4” (100mm), 4.5” (115mm), 6” (150mm) white aluminum with black and red markings 4” (100mm), 4.5” (115mm) white aluminum with black and red markings Case AISI 304 SS AISI 304 SS Lens Polycarbonate, High pressure BSP(G) and HP: Tempered safety glass Polycarbonate Ring AISI 304 SS AISI 304 SS Socket 316L SS, 2.5” (63mm) to 4.5” (115mm): Welded one-piece socket OT 58 brass Connection 1/4” NPT or 1/2” NPT standard, High Pressure: 1/2” BSP(G) or 9/16” autoclave or 1/4” autoclave with 9/16” gland/collar 1/4” NPT or 1/2” NPT standard Bourdon Tube 316L SS, drawn seamless Phosphor bronze Movement 304 SS (under and overload stops 4” to 6”) OT 59 brass (under and overload stops 4”) Pointer 2.5” (63mm): Aluminum, anodized black, 4” (100mm), 4.5” (115mm), 6” (150mm): Aluminum, anodized black, micrometer adjustable 4” (100mm), 4.5” (115mm): Aluminum, anodized black Welding Laser welded socket to case Silver alloy Fill Liquid Glycerin Glycerin Over-pressure Limit 25% for pressures up to 1,450 psi (9,998 kPa), 15% for pressures over 1,450 psi (9,998 kPa) 25% for pressures up to 1,450 psi (9,998 kPa), 15% for pressures over 1,450 psi (9,998 kPa) Socket Gasket 2.5” (63mm), 4” (100mm), 4.5” (115mm): Welded (no gasket) 6” (150mm): Buna N for one-piece external socket seal, (silicone rubber option) Buna N for two-piece internal socket seal Fill Plug Buna N (silicone rubber option) Buna N (silicone rubber option) Lens Ring Gasket Buna N (silicone rubber option) Buna N (silicone rubber option) Working Pressure Maximum 75% of full scale value Maximum 75% of full scale value Ambient Temperature Dry: -40°F to 250°F (-40°C to 120°C) Glycerin Filled: -4°F to 150°F (-20°C to 65°C) Dry: -40°F to 200°F (-40°C to 93°C) Glycerin Filled: -4°F to 150°F (-20°C to 65°C) Process Temperature -40°F to 250°F (-40°C to 120°C) -40°F to 200°F (-40°C to 93°C) Accuracy 2.5” (63mm): ±1.5% of full scale value 4” (100mm), 4.5” (115mm), 6” (150mm): ±1% ANSI/ ASME Grade 1A 4” (100mm), 4.5” (115mm): ±1% ANSI/ASME Grade 1A Enclosure Rating NEMA 4X/IP66, EN60529-1 (IEC529-1) NEMA 4X/IP66, EN60529-1 (IEC529-1) Warning (brass internals only) N/A WARNING: This product can expose you to chemicals including lead, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov.
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Otherrangesandconnectionsizesavailableuponrequest.316SScaseandmountablebezelavailableuponrequest.Forscalechange,refertoHowtoOrderGuideforscalecodes.For options, attach suffix to end of order code: i.e. PFP929R1-25UC for U-CLAMP.
Single Scale Order Codes (products in bold are normally stock in North America)
2.5” Back Connection with Front Flange2.5” Bottom Connection with Back Flange
Dual Scale Order Codes (products in bold are normally stock in North America)
Otherrangesandconnectionsizesavailableuponrequest.316SScaseandmountablebezelavailableuponrequest.Forscalechange,refertoHowtoOrderGuideforscalecodes.For options, attach suffix to end of order code: i.e. PFP929-25UC for U-CLAMP.
Otherrangesandconnectionsizesavailableuponrequest.316SScaseandmountablebezelavailableuponrequest.Forscalechange,refertoHowtoOrderGuideforscalecodes.For options, attach suffix to end of order code: i.e. PFP9652T1-4UC-P for U-CLAMP.Option suffix:4BF=4”(100mm)Backflange EN=EN837-1compliant 4FF=4”(100mm)Frontflange RSP4=4”(100mm)Redsetpointer4SS=4”(100mm)SScase SF4=4”(100mm)Siliconefilled4UC-P=4”(100mm)U-Clamppremium SG-4=4”(100mm)Safetyglasslens DRY=Supplygaugedry
Otherrangesandconnectionsizesavailableuponrequest.316SScaseandmountablebezelavailableuponrequest.Forscalechange,refertoHowtoOrderGuideforscalecodes.For options, attach suffix to end of order code: i.e. PFP1311-DRY for DRY GAUGE.Option suffix:DRY=Supplygaugedry SF45=4.5”(115mm)Siliconefilled EN=EN837-1compliant SG-45=4.5”(115mm)Safetyglasslens
4.5” Bottom Connection with Back Flange 4.5” Back Connection with Front Flange
Other ranges and connection sizes available upon request. For scale change, refer to How to Order Guide for scale codes. For options, attach suffix to end of order code: i.e. PFP1064-SC for SAFETY CASEOption suffix:6BF = 6” (150mm) Back flange EN = EN837-1 compliant 6FF = 6” (150mm) Front flange RSP6 = 6” (150mm) Red set pointer 6SS = 6” (150mm) SS case SC = 6” (150mm) Safety case 6UC = 6” (150mm) U-Clamp SF6 = 6” (150mm) Silicone fillDRY = Supply gauge dry SG-6 = 6” (150mm) Safety glass lens