BrandTech ® Scientific, Inc. 888-522-2726 www.brandtech.com PFA TRACE ANALYSIS LABWARE VITLAB ® PFA Labware: pure, cleanable, rugged Scanning electron microscopy illustrates the advantages of PFA in trace analysis. (Magnification: 8000X) VITLAB ® trace analysis labware is manufactured from PFA (a perfluoroalkoxy copolymer), which is highly resistant to heat and chemical contamination and has surface properties that greatly simplify cleaning. Use this labware for excellent results in ICP- MS, production and storage of trace analysis standards, isotope separations, sample digestions, and more. With the increasing need in trace analysis labs for ultra-low concentration determinations in the ng/g (ppb) and pg/g (ppt) range, the use of PFA labware has become more and more important. Other materials, when not specially treated, may be subject to interaction between the vessel and the sample, standards or reagents it contains. This may cause incorrect results with modern trace analysis instrumentation. All VITLAB ® PFA trace analysis labware features visible, accurate, and permanent graduations for precise measuring. PFA labware is suitable for sterilization using heat, gas, and chemical methods for handling sensitive biological solutions. Excellent temperatures stability: VITLAB ® PFA trace analysis labware maintains its stability in temperatures from -200º C to 250º C (-328º F to 482º F). No leachable metals: PFA is manufactured without metals such as calcium, aluminum, iron, magnesium, nickel, copper, manganese or zinc. These metals can leach into samples from other containers, and contaminate samples. Simplified cleaning: Conventional labware for trace analysis requires time-consuming and expensive cleaning. The hydrophobic and anti-adhesive properties of the exceptionally smooth-surfaced PFA labware simplify the cleaning process, making it ideal for trace analysis. Superior chemical resistance: PFA is inert with most reagents, including the nitric and hydrochloric acid routinely used in cleaning trace analysis labware. This stability significantly reduces the risk of cross-contamination. Excellent long-term stability: PFA containers often extend the stability of low (ppb) concentration standards. Such stability reduces the time and cost of renewing trace analysis standard solutions. Highly translucent: Translucency is important for making accurate measurements using volumetric labware. Properties Bottle – HDPE Scanning electron microscopy of this bottle wall shows the roughness of HDPE. The increased surface area of HDPE can lead to carryover of reagent molecules. Beaker – PTFE Similar to HDPE, electron micrographs of this PTFE beaker reveal a typically rough surface that can interact with reagent molecules and complicate cleaning. Evaporating dish – PFA Even at 8000x magnification, the surfaces of this PFA evaporating dish are very smooth. It is this smoothness, combined with PFA’s hydrophobic, anti-adhesive and inert properties, that simplify cleaning. Performing trace analysis? See the BRAND ® Dispensette ® S Trace Analysis bottletop dispenser for Trace Analysis on the back page.
4
Embed
PFA TRACE ANALYSIS LABWARE - brandtech.com Analysis.pdf · BT ® S I PFA TRACE ANALYSIS LABWARE VITLAB® PFA Labware: pure, cleanable, rugged Scanning electron microscopy illustrates
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
BrandTech® Scientific, Inc. 888-522-2726 www.brandtech.com
PFA TRACE ANALYSIS LABWARE
VITLAB® PFA Labware: pure, cleanable, ruggedScanning electron microscopy illustrates the advantages of PFA in trace analysis. (Magnification: 8000X)
VITLAB® trace analysis labware is manufactured from PFA (a perfluoroalkoxy copolymer), which is highly resistant to heat and chemical contamination and has surface properties that greatly simplify cleaning. Use this labware for excellent results in ICP-MS, production and storage of trace analysis standards, isotope separations, sample digestions, and more.
With the increasing need in trace analysis labs for ultra-low concentration determinations in the ng/g (ppb) and pg/g (ppt) range, the use of PFA labware has become more and more important. Other materials, when not specially treated, may be subject to interaction between the vessel and the sample, standards or reagents it contains. This may cause incorrect results with modern trace analysis instrumentation.
All VITLAB® PFA trace analysis labware features visible, accurate, and permanent graduations for precise measuring. PFA labware is suitable for sterilization using heat, gas, and chemical methods for handling sensitive biological solutions.
Excellent temperatures stability: VITLAB® PFA trace analysis labware maintains its stability in temperatures from -200º C to 250º C (-328º F to 482º F).
No leachable metals: PFA is manufactured without metals such as calcium, aluminum, iron, magnesium, nickel, copper, manganese or zinc. These metals can leach into samples from other containers, and contaminate samples.
Simplified cleaning: Conventional labware for trace analysis requires time-consuming and expensive cleaning. The hydrophobic and anti-adhesive properties of the exceptionally smooth-surfaced PFA labware simplify the cleaning process, making it ideal for trace analysis.
Superior chemical resistance: PFA is inert with most reagents, including the nitric and hydrochloric acid routinely used in cleaning trace analysis labware. This stability significantly reduces the risk of cross-contamination.
Excellent long-term stability: PFA containers often extend the stability of low (ppb) concentration standards. Such stability reduces the time and cost of renewing trace analysis standard solutions.
Highly translucent: Translucency is important for making accurate measurements using volumetric labware.
Propert ies
Bottle – HDPE
Scanning electron microscopy of this bottle wall shows the roughness of HDPE. The increased surface area of HDPE can lead to carryover of reagent molecules.
Beaker – PTFE
Similar to HDPE, electron micrographs of this PTFE beaker reveal a typically rough surface that can interact with reagent molecules and complicate cleaning.
Evaporating dish – PFA
Even at 8000x magnification, the surfaces of this PFA evaporating dish are very smooth. It is this smoothness, combined with PFA’s hydrophobic, anti-adhesive and inert properties, that simplify cleaning.
Performing trace analysis?See the BRAND® Dispensette® S Trace Analysis bottletop dispenser for Trace Analysis on the back page.
BrandTech® Scientific, Inc. 888-522-2726 www.brandtech.com
PFA Trace Analysis Labware
Low-form Griffin Beakers
• • Molded graduations are easy to read and resistant to wear from repeated use
• • Nesting design conserves bench and storage space
• • Autoclavable at 121º C (250º F) and easy to clean
• • Can withstand temperatures from -200º C to +250º C
BrandTech® Scientific, Inc. 888-522-2726 www.brandtech.com
Dispensette® S Trace Analysis Bottletop Dispenser
Lab Rats Trust BrandTech!
The high-purity materials release virtually no metal ions after appropriate cleaning. This makes the Dispensette® S Trace Analysis bottletop dispenser a superior choice for trace analysis.
Replaceable dispensing cartridge
If the piston seal is worn after a long period of use, the entire dispensing cartridge can easily be replaced without tools by the user. The cartridge is fully adjusted at the factory and delivered with a performance certificate. No calibration is required after replacement.
Serial dispensing
For easy serial dispensing, an optional flexible discharge tube with textured safety handle (not approved for HF) permits fast and precise dispensing, even into narrow test tubes. Integrated recirculation valve helps purge bubbles before dispensing.
Screw cap
Volume adjustment
Safety ring
Valve block
Recirculation tube
Telescoping filling tube
Recirculation valve
Discharge tube
For dispensing high-purity chemicals
The Dispensette® S Trace Analysis provides outstanding performance for precise-volume dispensing of high-purity media for trace analysis. The Dispensette® S Trace Analysis is also suitable for dispensing HF (Pt-Ir model).
The components of the fluid path have been selected to only contain the highest purity materials, such as fluoroplastics and sapphire. Depending on application, either platinum-iridium (Pt-Ir) or tantalum (Ta) valve springs can be chosen. The volume range is from 1 to 10 mL.
• Epecially well-suited for dispensing acids, bases and hydrogen peroxide (Tantalum (Ta) models only).
• Trace metal content of dispensed liquid is generally in the low ppb range or, depending on application, even in the low ppt range.
Dispensing of high-purity chemicals in trace analysis
• Plastics in contact with media consist of high-purity materials such as PTFE, ETFE, PCTFE, FEP and PFA. The purest sapphire is used for replaceable valves. Depending on the application, platinum-iridium or tantalum are available as spring materials.
• A field-tested cleaning process before use in trace analysis is described in the operating manual.
• Easy to disassemble for replacement of the dispensing cartridge.
* Hydrofluoric acid reacts slightly with sapphire resulting in mildly elevated aluminum values. To reduce these values we recommend discarding 3-5 dispensings of 2 mL each before performing the analysis.
The above recommendations reflect testing completed prior to publication. Always follow instructions in the operating manual of the instrument as well as the reagent manufacturer‘s specifications. Should you require information on chemicals not listed, please feel free to contact BrandTech®. Status as of: 0517/2