Wolf Safety Lamp Company HAZARDOUS AREA PORTABLE & TEMPORARY LIGHTING POWER DISTRIBUTION ATEX and IECEx certified portable and temporary lighting and power distribution systems for safe use in potentially explosive atmospheres worldwide. Wherever an explosive gas, vapour, mist or dust is present, creating a potential risk of explosion, Wolf Safety has hazardous area lighting with the concept of protection for Zone 0, 1 and 2 to ensure safety. IECEx
12
Embed
PETROL STATION FORECOURT DECANTING OF · PDF fileA complete ‘ATEX Explained’ poster is available upon request. ... ATEX and IECEx certified portable and temporary lighting and
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
lf Wo Safety Lamp Company
ATEX Explainedwww.wolf-safety.co.uk
Ex Equipment
PETROL STATION
GARAGE
FUEL STORAGE TANK
DECANTING OF FLAMMABLE LIQUIDFROM CONTAINER
TO CONTAINER
PETROL STATION FORECOURT
UNVENTILATEDGARAGE
INSPECTION PIT
FLAMMABLE MATERIALIN LIQUID FORM ZONE 0 ZONE 1 ZONE 2
GROUP II GAS SUBDIVISION
°
°
°
°
INGRESS PROTECTION (IP) CODE
1st Numeral 2nd Numeral
Potentially
Explosive
Atmosphere
EXAMPLE OF HAZARDOUS AREA ZONES
Ex Environment
Risk of ignition
Description CategorySymbolConcept
incendive
EN StandardIcon
IP66
Gas/Vapour Gas TemperatureTemperature Group Class
APPARATUS GROUPS AND TEMPERATURE CLASSES FOR COMMON EXPLOSIVE GASES AND VAPOURS
Dust type Dust Layer – Dust Cloud –minimum minimumignition ignitiontemperature (oC) temperature (oC)
IGNITION TEMPERATURES FOR COMMON COMBUSTIBLE DUSTS
Mining
Industrial
Group Typical Maximum Safe Maximum Safe Gap ApplicableHazard Sparking Energy Concepts
narr
ow
w
ide
less
m
ore
GAS GROUP
TEMPERATURE CLASS
Hot surfaces can ignite explosive atmospheres
PROTECTION CONCEPTS FOR ELECTRICAL APPARATUS
Potentially
Explosive
Atmosphere
Risk of ignition
ExplosionProtectedEquipment
T1
T2
T3
T4
T5
T6
This condensed guide is provided to aid in the selection of Wolf lighting products for use in potentially explosive atmospheres. Information given is based on practice within the EU as specified in the requirements of the 94/9/EC ATEX (Equipment) Directive and the 99/92/EC ATEX (Workplace) Directive.
A complete ‘ATEX Explained’ poster is available upon request.
HAZARDOUSAREAP O R T A B L E & T E M P O R A R Y L I G H T I N G
P O W E R D I S T R I B U T I O N
ATEX and IECEx certified portable and temporary lighting and power distribution systems for safe use in potentially explosive atmospheres worldwide.
Wherever an explosive gas, vapour, mist or dust is present, creating a potential risk of explosion, Wolf Safety has hazardous area lighting with the concept of protection for Zone 0, 1 and 2 to ensure safety.
IECEx
The range includes:
• Portable Lighting - Handheld straight and right-angled torches, headtorches, handlamps including the renowned Wolflite Handlamp, and warning lamps, with bulb and LED versions for use with either primary cell or rechargeable batteries and chargers.
• Temporary Lighting - Mains and low voltage temporary fluorescent and LED luminaires and floodlites, tank lighting kits, handheld leadlamps, battery operated LED worklights and compressed air operated pneumatic lamps.
• Temporary Power Distribution - Transformers 230V and 110V to 24V and 230V to 110V and high power transformers, splitter boxes, extension leads and cable reels.
Wherever an explosive gas, vapour, mist or dust is present, creating a potential risk of explosion, Wolf Safety has hazardous area lighting with the concept of protection for Zone 0, 1 and 2 to ensure safety.
Such situations for explosion protected lighting can be encountered offshore in the oil and gas industry, on ocean-going tankers and marine vessels, within the refining and petrochemical industries, in the manufacturing and processing of foodstuffs, pharmaceuticals and beverages, in breweries and distilleries, as well as fire-fighting, water treatment and gas distribution.
IECEx
Wolf Safety is the world’s leading manufacturer of hazardous area portable and temporary lighting, offering the widest range of ATEX and IECEx certified explosion protected lighting and power distribution systems designed in the United Kingdom for safe use in potentially explosive atmospheres worldwide.
KEY
ATEX CodeATEX / IECEX Certificate Numbers
Gas Area of Classification
Weight
Dust Area of Classification
Dimensions
LED Light Source
Rechargeable Cell Power Source
Light Duration
Voltage
Air Pressure and Consumption
Weight (including cells)
Primary Cell Power Source
Fluorescent Light Source
Bulb Light Source
Ingress Protection
Recharge Time
Enclosure
G
D
www.wolf-safety.co.uk
Primary Cell Mini Safety Torches
• ATEX and IECEx Approved for Zones 0, 1 and 2 gas and zones 20, 21 and 22 dust explosive atmospheres
• Lightweight and ultra small sizes
• T4 and T5 temperature classes
• Simple and robust designs with integral clips
• Single handed switching
• Ingress protection to IP67
• Group I Mining Approval
WOLF MICRO & MINI TORCHES
Primary Cell Midi Safety Torch
• ATEX and IECEx Approved for Zones 1 and 2 gas explosive atmospheres
• 189 lumen high output LED light source
• T3/T4 temperature class
• IIB Gas Group
• Midi compact size
• Compact and robust ergonomic design
• Single handed switch with protection shroud
• Ingress protection to IP67
• Group I M2 Mining Approval
• Supplied with a wrist strap and T4 approved cells
• ATEX Approved for Zones 1 and 2 gas and Zones 21 and 22 dust explosive atmospheres
• Robust durable GRP construction with stainless steel skid
• Compact, lightweight and portable configuration
• Fitted with ATX or CEAG plugs and x4 sockets and 15m SY input cable
• 110V or 230V input voltage available
• Integrated handle for ease of movement
• Alternative voltage, plugs and sockets available
30m Cable Extension Reel
• ATEX Approved for Zones 1 and 2 gas explosive atmospheres
• Compact and solid hard rubber reel body with flat steel frame
• Internal brake which does not produce friction on reel body
• Fitted with ATX or CEAG plugs and sockets with 30m HOFR cable
• 110V or 230V input voltage available
WOLF ATEX SPLITTER BOX
WOLF ATEX CABLE REEL
Ref L-260
II 2 GD Ex de IIC T5 Gb Ex tb IIIC T90°C Db IP66
Baseefa12ATEX0268
Zones 1 & 2
Zones 21 & 22
9.4Kg (inc cable)
445x 297 x 265mm
110V or 230V
IP66
GD
Also available in 1200VA with electrical circuit protection options including Short Circuit Fuse, MCB, RCBO and Mains Isolator
GRP - 400VA
1180
1180
0158
WOLF ATEX 400VA TRANSFORMER
Ref LL-114 LL-214 LL-221 LL-124 LL-224
II2 GD Ex ed IIC T3 II2 GD Ex ed IIC T4 Ex tD A21 IP66 T200°C Ex tD A21 IP66 T135°C
LCIE02ATEX6248X SIRA08ATEX3182X
Zones 1 & 2
Zones 21 & 22
21Kg 23Kg
504 x 465 x 285 mm 585 x 365 x 285 mm
GRP Stainless Steel
110V:24V 230V:24V 230V:110V 110V:24V 230V:24V
IP66
GD
Ref LL-300
II 2 G Ex de IIC* T6
PTB03ATEX1186
Zones 1 & 2
≈12Kg (inc cable)
412 x 314 x 319mm
110V or 230V
IP54
G
Temporary Power Transformer
• ATEX Approved for Zones 1 and 2 gas and Zones 21 and 22 dust explosive atmospheres
• Robust and durable construction and easily transportable
• Wide range of input and output voltages available
• Supplied with 15m SY cable, ATX plug and fitted with 4 x ATX socket outlets
• CEAG, STAHL and Marechal socket/plug options available
GRP - 1200VA
lf Wo Safety Lamp Company
ATEX Explainedwww.wolf-safety.co.uk
Ex Equipment
PETROL STATION
GARAGE
FUEL STORAGE TANK
DECANTING OF FLAMMABLE LIQUIDFROM CONTAINER
TO CONTAINER
PETROL STATION FORECOURT
UNVENTILATEDGARAGE
INSPECTION PIT
FLAMMABLE MATERIALIN LIQUID FORM ZONE 0 ZONE 1 ZONE 2
GROUP II GAS SUBDIVISION
°
°
°
°
INGRESS PROTECTION (IP) CODE
1st Numeral 2nd Numeral
Potentially
Explosive
Atmosphere
EXAMPLE OF HAZARDOUS AREA ZONES
Ex Environment
Risk of ignition
Description CategorySymbolConcept
incendive
EN StandardIcon
IP66
Gas/Vapour Gas TemperatureTemperature Group Class
APPARATUS GROUPS AND TEMPERATURE CLASSES FOR COMMON EXPLOSIVE GASES AND VAPOURS
Dust type Dust Layer – Dust Cloud –minimum minimumignition ignitiontemperature (oC) temperature (oC)
IGNITION TEMPERATURES FOR COMMON COMBUSTIBLE DUSTS
Mining
Industrial
Group Typical Maximum Safe Maximum Safe Gap ApplicableHazard Sparking Energy Concepts
narr
ow
w
ide
less
m
ore
GAS GROUP
TEMPERATURE CLASS
Hot surfaces can ignite explosive atmospheres
PROTECTION CONCEPTS FOR ELECTRICAL APPARATUS
Potentially
Explosive
Atmosphere
Risk of ignition
ExplosionProtectedEquipment
T1
T2
T3
T4
T5
T6
This condensed guide is provided to aid in the selection of Wolf lighting products for use in potentially explosive atmospheres. Information given is based on practice within the EU as specified in the requirements of the 94/9/EC ATEX (Equipment) Directive and the 99/92/EC ATEX (Workplace) Directive.
A complete ‘ATEX Explained’ poster is available upon request.