PROSIDING SENTRINOV Vol. 001, Tahun 2015 | ISSN: 2477 – 2097 254 PENGEMBANGAAN ALAT UJI KOMPOSISI MASSA PADA LOGAM PADUAN BINER MENGGUNAKAN SENSOR VOLUME DAN MASSA Agus Slamet 1) , Wahyu Djalmono P 2) , Anwar Sukito A 3) 1),2),3) Jurusan Teknik Mesin Polines, Jl. Prof. Soedarto,S.H., Semarang 503293 e-mail : [email protected]Abstract This composition testing equipment of binary alloy metal mass has work principles that are based on sinking or floating object on the surface of the liquid fluid, with the result that the force works on the object happens due to the pressure of the liquid fluid or so called buoyancy. The research that has been conducted by this composition testing equipment can be used to measure composition of two elements of metal mass with the result of the measurement of mass composition is different with the measurement using Spectrometer. The differences of the measurement result is caused by the readout of the changes in the volume of water is conducted manually by observing the changes in the water surface using both eyes. In this research, there is a development in a mass and volume data readout method using mass and volume sensor that are integrated with the data processing system software to avoid errors in data reading. This test will get the data from the testing equipment which is, displaced water volume and the test material before and after in the fluid. The research method starts from the planning and manufacturing the equipment using ultrasonic volume sensor and load cell mass sensor, followed by testing and data retrieval. The test material used contains of two elements, namely Tin (Sn) and Lead (Pb). The test results showed differences in the percentage composition of tools an average of 16.72% with the composition of the test material, because the possible use of ultrasonic sensor types that do not fit. Keywords : mass composition, biner alloy, sensor Abstrak Alat uji komposisi massa logam paduan biner ini prinsip kerjanya berdasarkan benda yang terbenam atau terapung pada permukaan fluida cair, maka gaya yang bekerja pada benda tersebut terjadi karena tekanan fluida cair atau disebut sebagai gaya buoyancy. Penelitian yang telah dilakukan alat uji komposisi tersebut dapat digunakan untuk mengukur komposisi massa logam paduan dua unsur dengan hasil pengukuran komposisi massa terdapat perbedaan dibandingkan dengan hasil pengukuran menggunakan Spectrometer. Perbedaan pengukuran/penyimpangan tersebut disebabkan cara pembacaan perubahan volume air masih manual dengan mengamati perubahan permukaan air dengan penglihatan mata. Pada penelitian ini dilakukan pengembangan cara pembacaan data volume dan massa menggunakan sensor volume dan massa yang terintegrasi dengan perangkat lunak sistem pengolahan data, Untuk menghindari kesalahan pembacaan data. Pengujian ini akan mendapatkan data dari alat uji adalah volume air yang dipindahkan dan massa bahan uji saat dan sebelum di dalam fluida. Metode penelitian yang dilakukan dimulai dari perancangan dan pembuatan alat dengan menggunakan sensor volume ultrasonik dan sensor massa load cell ,kemudian dilanjutkan dengan pengujian, pengambilan data. Bahan uji yang digunakan mengandung dua unsur yaitu Tin (Sn) dan Lead (Pb). Hasil pengujian alat menunjukan perbedaan prosentasi komposisi rata-rata 16,72% dengan komposisi benda uji. Karena dimungkinkan penggunaan tipe sensor ultrasonik yang tidak sesuai. Kata kunci : komposisi massa, paduan biner,sensor
13
Embed
PENGEMBANGAAN ALAT UJI KOMPOSISI MASSA PADA LOGAM …
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
PENGEMBANGAAN ALAT UJI KOMPOSISI MASSA PADA LOGAM PADUAN BINER MENGGUNAKAN SENSOR VOLUME DAN MASSA
Agus Slamet1), Wahyu Djalmono P2), Anwar Sukito A3)
1),2),3)Jurusan Teknik Mesin Polines, Jl. Prof. Soedarto,S.H., Semarang 503293 e-mail : [email protected]
Abstract
This composition testing equipment of binary alloy metal mass has work principles that are based on sinking or floating object on the surface of the liquid fluid, with the result that the force works on the object happens due to the pressure of the liquid fluid or so called buoyancy. The research that has been conducted by this composition testing equipment can be used to measure composition of two elements of metal mass with the result of the measurement of mass composition is different with the measurement using Spectrometer. The differences of the measurement result is caused by the readout of the changes in the volume of water is conducted manually by observing the changes in the water surface using both eyes. In this research, there is a development in a mass and volume data readout method using mass and volume sensor that are integrated with the data processing system software to avoid errors in data reading. This test will get the data from the testing equipment which is, displaced water volume and the test material before and after in the fluid. The research method starts from the planning and manufacturing the equipment using ultrasonic volume sensor and load cell mass sensor, followed by testing and data retrieval. The test material used contains of two elements, namely Tin (Sn) and Lead (Pb). The test results showed differences in the percentage composition of tools an average of 16.72% with the composition of the test material, because the possible use of ultrasonic sensor types that do not fit.
Keywords : mass composition, biner alloy, sensor
Abstrak
Alat uji komposisi massa logam paduan biner ini prinsip kerjanya berdasarkan benda yang terbenam atau terapung pada permukaan fluida cair, maka gaya yang bekerja pada benda tersebut terjadi karena tekanan fluida cair atau disebut sebagai gaya buoyancy. Penelitian yang telah dilakukan alat uji komposisi tersebut dapat digunakan untuk mengukur komposisi massa logam paduan dua unsur dengan hasil pengukuran komposisi massa terdapat perbedaan dibandingkan dengan hasil pengukuran menggunakan Spectrometer. Perbedaan pengukuran/penyimpangan tersebut disebabkan cara pembacaan perubahan volume air masih manual dengan mengamati perubahan permukaan air dengan penglihatan mata. Pada penelitian ini dilakukan pengembangan cara pembacaan data volume dan massa menggunakan sensor volume dan massa yang terintegrasi dengan perangkat lunak sistem pengolahan data, Untuk menghindari kesalahan pembacaan data. Pengujian ini akan mendapatkan data dari alat uji adalah volume air yang dipindahkan dan massa bahan uji saat dan sebelum di dalam fluida. Metode penelitian yang dilakukan dimulai dari perancangan dan pembuatan alat dengan menggunakan sensor volume ultrasonik dan sensor massa load cell ,kemudian dilanjutkan dengan pengujian, pengambilan data. Bahan uji yang digunakan mengandung dua unsur yaitu Tin (Sn) dan Lead (Pb). Hasil pengujian alat menunjukan perbedaan prosentasi komposisi rata-rata 16,72% dengan komposisi benda uji. Karena dimungkinkan penggunaan tipe sensor ultrasonik yang tidak sesuai.
Perbedaan nilai hasil pengukuran pada Tabel 2 untuk ketiga bahan uji tidak ada
yang sama dapat diindikasikan bahwa sensor volume atau tipe sensor ultrasonik yang
digunakan tidak sesuai karena pada sensor yang digunakan antara transmitter dan receiver
mempunyai jarak, sehingga gelombang suara yang dipancarkan dipengaruhi oleh
permukaan diding gelas ukur dan terjadi bias dalam mengukur jarak permukaan air di
gelas ukur. Pada data pengukuran perubahan volume pembacaan oleh sensor terjadi
perbedaan cukup signifikan dengan nilai pembacaan dengan gelas ukur. Ada
kemungkinan nilai komposisi massa dari bahan uji yang telah ditentukan sebenarnya
nilainya tidak sebesar pada Tabel 1. Analisis ini berdasarkan pada ketiga bahan uji seperti
pada Tabel 1 komposisi massanya setelah dilakukan pengecoran belum diuji dengan
menggunakan Spectrometer, sehingga tidak menutup kemungkinan komposisi massanya
tidak seperti tersebut di atas.
SIMPULAN
Berdasarkan dari hasil pengujian dan pengambilan data serta pembahasannya maka dapat
dibuat kesimpulan sebagai berikut :
1. Rancang bangun Alat Uji Komposisi Massa dapat berfungsi untuk mengukur
logam dengan paduan dua unsur dengan luaran massa bahan uji sebelum maupun
saat di dalam fluida (air) sebagi representasi resultan gaya dan volume air yang
dipindahkan atau volume bahan uji.
2. Hasil pengukuran komposisi massa dari hasil pengujian dari ketiga bahan uji
menghasilkan perbedaan nilai komposisi massa dibandingkan dengan nilai yang
sudah ditentukan. Nilai perbedaan untuk bahan uji A,B dan C berturut-turut 18,81
%, 19,85 % dan 11,5 %.
3. Analisis perbedaan nilai hasil dari pengukuran disebabkan penggunaan tipe sensor
ultrasonik yang mempunyai transmitter dan receiver terpisah menyebabkan hasil
pengukuran menyimpang, serta komposisi massa bahan uji belum diuji
kebenarannya nilainya dengan Spectrometer.
DAFTAR PUSTAKA
Agus Slamet, Amrul,2007, Rancang Bangun Alat Uji Komposisi Massa Pada Logam Paduan Berdasarkan Gaya Fluida, Jati Undip,Jurnal Teknik, Vol. 7,No.1, Industri Universitas Diponegoro.
Ferry Nur Akbar,Dkk, 2015, Rancang Bangun Aplikasi Microcontroller Dan Sensor Load Cell Serta Sensor Ultrasonic Pada Mesin Uji Komposisi Logam Paduan Biner Dengan Prinsip Distribusi Gaya Angkat Fluida Statis, Laporan Tugas Akhir, Jurusan Teknik Mesin Polines, Semarang
Gigih Priyo Nugroho,Dkk, 2013, Sistem Pendeteksi Dini Banjir Menggunakan Sensoor Kecepatan Air dan Sensor Ketinggian Air Pada Mikrokontroler Arduino, Jurnal Teknik POMITS, Vol 2,No.1, Surabaya.
Robert W Fox, 2004, Introduction To Fluid Mechanics, John Wiley&Son, New York.