Top Banner
IAEA International Atomic Energy Agency A Retrospective Look on Plant Events for Evolving Expectations Nuclear safety IEEE NPEC Meeting July 30, 2014 Thomas Koshy, Head Nuclear Power Technology Development Department of Nuclear Energy
30

A Retrospective Look on Plant Events for Evolving ...grouper.ieee.org/groups/npec/N15-01_NPEC presentations...IAEA International Atomic Energy Agency A Retrospective Look on Plant

Mar 07, 2018

Download

Documents

lamtram
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: A Retrospective Look on Plant Events for Evolving ...grouper.ieee.org/groups/npec/N15-01_NPEC presentations...IAEA International Atomic Energy Agency A Retrospective Look on Plant

IAEAInternational Atomic Energy Agency

A Retrospective Look on Plant Events for Evolving Expectations

Nuclear safety

IEEE NPEC Meeting July 30, 2014

Thomas Koshy, HeadNuclear Power Technology Development

Department of Nuclear Energy

Page 2: A Retrospective Look on Plant Events for Evolving ...grouper.ieee.org/groups/npec/N15-01_NPEC presentations...IAEA International Atomic Energy Agency A Retrospective Look on Plant

IAEA

AGENDA

• Evolving Safety Expectations • Historic Events • Critical Areas for Nuclear safety

• Reactor Trip• Depressurization• Emergency Core Cooling• Containment Integrity

• Undesirable failure Modes• Conclusion

T.Koshy, NPTDS/IAEA 2

Page 3: A Retrospective Look on Plant Events for Evolving ...grouper.ieee.org/groups/npec/N15-01_NPEC presentations...IAEA International Atomic Energy Agency A Retrospective Look on Plant

IAEA

Evolving Safety Expectations

• Emergency Core cooling back fit to Yankee Rowe

• Transient without SCRAM – Salem station 10CFR50.62

• Station Blackout -10CFR50.63• Safety Enhancements from TMI – 10CFR

50.49

T.Koshy, NPTDS/IAEA 3

Page 4: A Retrospective Look on Plant Events for Evolving ...grouper.ieee.org/groups/npec/N15-01_NPEC presentations...IAEA International Atomic Energy Agency A Retrospective Look on Plant

IAEA

Events That Changed the Course

Chernobyl Unit 4

Fukushima Dai-ichiUnits 1 - 4 4

Page 5: A Retrospective Look on Plant Events for Evolving ...grouper.ieee.org/groups/npec/N15-01_NPEC presentations...IAEA International Atomic Energy Agency A Retrospective Look on Plant

IAEA

IMPORTANCE RANKING

29 July - 2 August 20136th IAEA INPRO Dialogue Forum on Licensing and Safety Issues of SMRs

5

Key Benefits: Enhanced safety, lower EI, and energy supply security

Page 6: A Retrospective Look on Plant Events for Evolving ...grouper.ieee.org/groups/npec/N15-01_NPEC presentations...IAEA International Atomic Energy Agency A Retrospective Look on Plant

IAEA

Historic Events (IRS report # 7788)

2006 Forsmark -1 • 400KV Switchyard work resulted in overvoltage

and an under voltage transient • 2 out of the 4 trains of vital AC power lost and

the respective EDGs failed. • Alternate AC power failed to start• Half of the control room indications were lost• Relief valves stayed open (LOCA?)• Two buses that operated had the same failure

susceptibility• A near - Station Blackout event

6T.Koshy, NPTDS/IAEA

Page 7: A Retrospective Look on Plant Events for Evolving ...grouper.ieee.org/groups/npec/N15-01_NPEC presentations...IAEA International Atomic Energy Agency A Retrospective Look on Plant

IAEA

Historic Events (IRS Report # 6341)

1993 Narora-1 Event• Ejected turbine blade caused a fire and

hydrogen explosion• Complete loss of power – station blackout for

17hrs.• Diesel driven fire pumps aligned to inject water

into the steam generator• No radiological impact onsite or offsite

7T.Koshy, NPTDS/IAEA

Page 8: A Retrospective Look on Plant Events for Evolving ...grouper.ieee.org/groups/npec/N15-01_NPEC presentations...IAEA International Atomic Energy Agency A Retrospective Look on Plant

IAEA

Historic Events

2001 Maanshan• Tropical storm caused loss of offsite power• Both Emergency Diesel Generators (EDG)

failed • Station blackout for 2 hours• AC safety buses became irrecoverable• One Diesel generator was later recovered to

establish core cooling8T.Koshy, NPTDS/IAEA

Page 9: A Retrospective Look on Plant Events for Evolving ...grouper.ieee.org/groups/npec/N15-01_NPEC presentations...IAEA International Atomic Energy Agency A Retrospective Look on Plant

IAEA

Historic Events

2011 Fukushima• Tsunami caused salt water ingress into plant

areas of several units• Station Blackout for extended period• DC controlled Steam-driven cooling system &

Ice condenser operated for limited periods2012 ByronSBO for 8 min. immediately following Rx Trip: close call for seal LOCA (NRC BULLETIN 2012-01)

9T.Koshy, NPTDS/IAEA

Page 10: A Retrospective Look on Plant Events for Evolving ...grouper.ieee.org/groups/npec/N15-01_NPEC presentations...IAEA International Atomic Energy Agency A Retrospective Look on Plant

IAEA

Event Statistics (1997-2012) IRS reports

• Failed/Affected Systems: Emergency core cooling - 202

• Significant degradation of safety function -284

• Degradation of containment function/integrity- 44

10T.Koshy, NPTDS/IAEA

Page 11: A Retrospective Look on Plant Events for Evolving ...grouper.ieee.org/groups/npec/N15-01_NPEC presentations...IAEA International Atomic Energy Agency A Retrospective Look on Plant

IAEA

Critical Areas for Nuclear SafetyFor Light Water Reactors

Defence in Depth needs to be established in each of the following critical functions:

• Reactor Trip• Depressurization• Emergency Core Cooling• Containment Integrity

T.Koshy, NPTDS/IAEA 11

Page 12: A Retrospective Look on Plant Events for Evolving ...grouper.ieee.org/groups/npec/N15-01_NPEC presentations...IAEA International Atomic Energy Agency A Retrospective Look on Plant

IAEA

Challenges: Low Frequency & High Consequence Events

• External Events (Design Bases & Extensions)• Tsunami, seismic event, forest fire, flooding,

malicious act, jet impact, volcano, sandstorm• Internal Events

• Explosion, fire, malicious act• Plant Challenges

• Station Black out, Irrecoverable damage to electric buses, Loss of control room

• D C bus failure• Software lock up

T.Koshy, NPTDS/IAEA 12

Page 13: A Retrospective Look on Plant Events for Evolving ...grouper.ieee.org/groups/npec/N15-01_NPEC presentations...IAEA International Atomic Energy Agency A Retrospective Look on Plant

IAEA

Refined Goal

• “The set of planned, coordinated & implemented systems ensuring nuclear plants are designed, constructed….. using an all risk approach.”

• Greater level of safety would come not from all passive or all active core cooling but a combination of the two.

- ASME “Forging a New Nuclear Safety Construct Publication” Associated Workshop Breakout Session Dec 2012, Washington

T.Koshy, NPTDS/IAEA 13

Page 14: A Retrospective Look on Plant Events for Evolving ...grouper.ieee.org/groups/npec/N15-01_NPEC presentations...IAEA International Atomic Energy Agency A Retrospective Look on Plant

IAEA

Reactor Trip Challenges & Solutions

• The Anticipated Transients with out SCRAM (10CFR 50.62)

• Solutions:• Diverse tripping (Additional trip solenoid for actuating the

breaker trip bar) Alternate Rod Insertion/ boration -diversity

• Direct-wired manually operated trip breakers with capability to operate from control room and remote shutdown area - diversity

• The power supply, sensors and actuation exclusively dedicated to trip function - redundancy & diversity

T.Koshy, NPTDS/IAEA 14

Page 15: A Retrospective Look on Plant Events for Evolving ...grouper.ieee.org/groups/npec/N15-01_NPEC presentations...IAEA International Atomic Energy Agency A Retrospective Look on Plant

IAEA

Reason for Separating ECCS & RPS

• At North Anna, Unit 2, one diode failure caused Rx Trip & ECCS actuation.

• Consequently pressurizer overfilled, Power operated relief valve (PORV) cycled several times. Pressure relief tank rupture disk ruptured (USNRC IN: 2009-03)

• Safety Injection could not be reset from control room to prevent primary system going water solid

• A single failure affected RPS & ECCST.Koshy, NPTDS/IAEA 15

Page 16: A Retrospective Look on Plant Events for Evolving ...grouper.ieee.org/groups/npec/N15-01_NPEC presentations...IAEA International Atomic Energy Agency A Retrospective Look on Plant

IAEA

Reason for Separating ECCS & RPS • At Forsmark, 2 UPS failures caused:

• A reactor trip, Core Cooling Actuation ( 2 out of 4 trains injected water)

• Relief valves (ADS) stuck open 28 min. (until power was recovered to vital bus)

• Two UPS failures from a common cause resulted in reactor trip & a LOCA (relief valve stayed open) challenging RCS recovery• Yankee Rowe also had a similar event when vital bus voltage

declined when coasting EDG remained connected to the bus)

• Remove shared elements between ECCS & RPS to prevent common cause failures

T.Koshy, NPTDS/IAEA 16

Page 17: A Retrospective Look on Plant Events for Evolving ...grouper.ieee.org/groups/npec/N15-01_NPEC presentations...IAEA International Atomic Energy Agency A Retrospective Look on Plant

IAEA T.Koshy, NPTDS/IAEA 17

IEEE Std 603-2009 ANNEX A: Endorsed in USNRC 10CFR50

Consider consequences of one or more UPS failures / loss of power etc., and conduct a thorough failure modes and effects analysis (FMEA)

Page 18: A Retrospective Look on Plant Events for Evolving ...grouper.ieee.org/groups/npec/N15-01_NPEC presentations...IAEA International Atomic Energy Agency A Retrospective Look on Plant

IAEA

Historic Successes

• Diesel-driven fire pump helped mitigation• DC/Battery power controlled steam-driven

cooling systems:• Reactor core isolation cooling• Steam driven auxiliary feed systems• Steam isolation condenser / heat exchanger

• Independent Alternate AC sources manually aligned to a fault-free bus helped core cooling

18T.Koshy, NPTDS/IAEA

Page 19: A Retrospective Look on Plant Events for Evolving ...grouper.ieee.org/groups/npec/N15-01_NPEC presentations...IAEA International Atomic Energy Agency A Retrospective Look on Plant

IAEA

Diversity in Core Cooling

• In addition to passive cooling systems:• Suitable combination of Electric, Diesel, Air,

Steam driven • Protected from regional extreme environments,

strategically located: each one associated with a train (Portable for severe accident conditions)

• Provision for external powering from skid mounted energy sources

T.Koshy, NPTDS/IAEA 19

Page 20: A Retrospective Look on Plant Events for Evolving ...grouper.ieee.org/groups/npec/N15-01_NPEC presentations...IAEA International Atomic Energy Agency A Retrospective Look on Plant

ALTERNATE POWER SOURCES WITH DIVERSITY

FULL LOAD GENERATOR OUTPUT BREAKER

TRANSMISSION SYSTEM

ONE LINE AC DIAGRAM: THREE TRAIN SYSTEM (n+2)

EMERGENCY DIESEL

GENERATOR

ALTERNATE AC POWER

NONCLASS 1E BUS A NON CLASS 1E BUS C

CLASS 1E BUS CCLASS 1E BUS A

SWITCHYARDS

MAIN GENERATOR

EMERGENCY DIESEL

GENERATOR

Start upTransformers

Auxiliary Transformers

HIGH VOLTAGE (500KV Typ.) VOLTAGE LEVEL 2

(135 KV Typ.)

NON CLASS 1E BUS B

CLASS 1E BUS B

EMERGENCY DIESEL

GENERATOR

OTHER SOURCES

Page 21: A Retrospective Look on Plant Events for Evolving ...grouper.ieee.org/groups/npec/N15-01_NPEC presentations...IAEA International Atomic Energy Agency A Retrospective Look on Plant

IAEA

Robust Power System• Main Generator Output breaker

• Prevent power interruption to onsite power systems following a generator trip (eliminates the need for fast transfer)

• The additional cost is recovered if one plant trip is avoided

• Two sources of offsite power made available to each safety bus for emergency and normal shutdown• It is desirable to upgrade the immediate switchyard

providing offsite power to be built and electrically protected to a higher standard (Fukushima lesson)

T.Koshy, NPTDS/IAEA 21

Page 22: A Retrospective Look on Plant Events for Evolving ...grouper.ieee.org/groups/npec/N15-01_NPEC presentations...IAEA International Atomic Energy Agency A Retrospective Look on Plant

IAEA T.Koshy/NPTDS/IAEA 22

Millstone-2 Undesirable Failure Modes• On July 6, 1992 , during a refueling outage, the

licensee identified several undesirable failure modes of a two-out-of-four logic following an event. The plant was designed with two sensor cabinets and one actuation cabinet for each of the two trains. (Information Notice 93-11)• When power was lost to either one of the vital buses it

caused safety injection and sump recirculation actuation. (Core cooling failure)

• When two of the sensor cabinets in a train lost power it caused the containment sump outlet valves to open

• Loss of DC power to one actuation train caused power operated relief valve in the other train to open

• The logic was modified to limit certain combinations of two-out-of-four logic to prevent this problem.

Page 23: A Retrospective Look on Plant Events for Evolving ...grouper.ieee.org/groups/npec/N15-01_NPEC presentations...IAEA International Atomic Energy Agency A Retrospective Look on Plant

IAEA

Failure Modes & Effects Analysis

• Need Focus on:• Partial power supply failures (2 of the 4 UPS

fails) as a consequence to short circuit, fuse blow etc.,

• Gradual degradation of Voltage;(progressing faults, degrading battery, etc.,

• Degrading hydraulic or air pressure • Examine the failure mode and design for

desirable failure modes

T.Koshy, NPTDS/IAEA 23

Page 24: A Retrospective Look on Plant Events for Evolving ...grouper.ieee.org/groups/npec/N15-01_NPEC presentations...IAEA International Atomic Energy Agency A Retrospective Look on Plant

IAEA

Diversity in Depressurization• Depressurization – very critical for active &

passive cooling system• (generally achieved using multiple valves using

same technology)• Solutions:

• Incorporate minimum of two approaches (electronically fired, pilot-air operated,..)

• Retain manual capability with DC powered valves as a back up with provisions for external powering or fully manual

• Capability for remote operation.T.Koshy, NPTDS/IAEA 24

Page 25: A Retrospective Look on Plant Events for Evolving ...grouper.ieee.org/groups/npec/N15-01_NPEC presentations...IAEA International Atomic Energy Agency A Retrospective Look on Plant

IAEA

Defense in Depth for Preserving Containment Integrity

• Containment is the last defense• Need to consider severe accident • Solutions:

• Redundant spray headers with cooling capability• Reliable hardened venting and filtration• Hydrogen detection and control• External provisions (potable equipment, etc.,)

• containment cooling• Supplementing water supply for cavity flooding• Hydrogen control

T.Koshy, NPTDS/IAEA 25

Page 26: A Retrospective Look on Plant Events for Evolving ...grouper.ieee.org/groups/npec/N15-01_NPEC presentations...IAEA International Atomic Energy Agency A Retrospective Look on Plant

IAEA

DC Power System (Typical of Three)• Strategically located DC bus with two battery

chargers with at least one connected to an alternate source

• DC power for ECCS actuation with its dedicated sensors and processing (Least intervening components to reduce failure modes – inverter, power supply modules etc., IEEE 603 concept) Auctioneered power supply for increased reliability

• Reactor Protection System (RPS) powered from Vital AC (To be fail-safe such that any process signal with a logic or support system outside the acceptable band would trigger a reactor trip. IEEE 603 concepts)

T.Koshy, NPTDS/IAEA 26

Page 27: A Retrospective Look on Plant Events for Evolving ...grouper.ieee.org/groups/npec/N15-01_NPEC presentations...IAEA International Atomic Energy Agency A Retrospective Look on Plant

27

STANDBY POWER FOR NON-ELECTRIC CORE COOLINGSYSTEMS (Gas/Diesel/Air Driven)

BATTERY CHARGER

INVERTER

MAINTENANCEBYPASS

VITAL POWER 208/120 VAC

TRAIN A CLASS 1E DC BUS 250/125 VDC

TRAIN A CLASS 1E AC POWER BUS 4160 V

EMERGENCY DIESEL

GENERATORSTART-UPTRANSFORMER

BATTERYBANK

STATION AUXILIARY TRANSFORMER

CRITICAL CONTROL ROOM DISPLAYS

EMERGENCY CORE COOLING SYSTEM (ECCS) CIRCUITS,,

SWINGBATTERY CHARGER

ALTERNATE AC POWER

DC Bus One Line Diagram (One of Three Trains)

Fail-safe systems only (Rod Drop –Reactor Protection System - RPS)

Page 28: A Retrospective Look on Plant Events for Evolving ...grouper.ieee.org/groups/npec/N15-01_NPEC presentations...IAEA International Atomic Energy Agency A Retrospective Look on Plant

IAEA

Conclusions

• Build defence in depth through diversity in each of the critical safety functions: Reactor Trip, Depressurization, Core Cooling, and Containment Cooling

• Expand FEMA to include partial loss of power, gradual degradation of energy sources, and confirm if the failure modes are desirable

T.Koshy, NPTDS/IAEA 28

Page 29: A Retrospective Look on Plant Events for Evolving ...grouper.ieee.org/groups/npec/N15-01_NPEC presentations...IAEA International Atomic Energy Agency A Retrospective Look on Plant

IAEA

IEEE Considerations

• Revise IEEE 603 to include additional safety provisions? Develop a new standard?

T.Koshy, NPTDS/IAEA 29

Page 30: A Retrospective Look on Plant Events for Evolving ...grouper.ieee.org/groups/npec/N15-01_NPEC presentations...IAEA International Atomic Energy Agency A Retrospective Look on Plant

IAEA 30

Thank you for your [email protected]

Questions ?