8/6/2019 PB_FireResistance_Sep04
1/16
Performance Based ProductsBGC Fire-Resistant Plasterboard Installation Design Guide
Fire-Resistant PlasterboardNon-Load Bearing Partition Systems
MANUALBGC PB-FR 203 AUGUST 2004
PlasterboardFibre Cement
8/6/2019 PB_FireResistance_Sep04
2/16
Page 2
BGC PlasterboardBefore commissioning a Plasterboard plant in Australia, BGC researched the world's foremost plasterboard
manufacturing countries, in order to adopt the most advanced production techniques, available today.
BGC Plasterboard is purpose designed as a complete wall and ceiling lining system that conforms to the stringentdemands of regulatory bodies throughout Australia and overseas.
Our highly professional team of engineers and skilled personnel maintain world class plant and equipment at our
Western Australian factory premises and, together with the Company's pursuance of manufacturing excellence,
assures the specifying and building industry of quality BGC Plasterboard products.
As a wholly owned, privately operated Australian company, BGC recognises the importance of product Research and
Development programmes. Continued investment into this disipline ensures BGC will remain a leader in the
manufacturing and supply of quality building products and materials.
8/6/2019 PB_FireResistance_Sep04
3/16
Page 3
ContentsIntroduction 3
Early Fire Hazard Indices 3
Availability 3Application 4
Installation 4
Fire-Rated Wall Cold-Formed-Section Steel Framed
Construction-Non Load Bearing 5
Fire-Rated Wall Cold-Formed-Section Timber Framed
Construction-Non Load Bearing 6
Plasterboard and Fibre Cement Fire and
Acoustic Rated Walls 8
Steel Frame Installation Details 11
Timber Frame Installation Details 13
BGC Fire-Resistant (FR)Plasterboard Non-Load BearingPartition Systems
IntroductionBGC Plasterboards Fire-Rated Systems, consist of
single or multiple layers of BGC FR Plasterboardsheets, screw-fixed to steel framing and nail or screw
fixed to timber stud framing non-load bearing.
BGC FR Plasterboard is manufactured to the
requirements of Australian Standards AS/NZS
2588:1998 - Gypsum plasterboard and must be
installed in accordance with the Australian Standards
AS/NZS 2589.1:1997 - Gypsum linings in residential
and light commercial construction-application and
finishing. Part 1: Gypsum plasterboard.
BGC FR Plasterboard Fire Rated Systems have beentested AS/NZS 3837: 1998 and AS/NZS 1530.4:
1997, by NATA accredited testing laboratori es.
Test reports and letters of opinion are available on
request from BGC Plasterboard.
BGC FR Plasterboard has a light-pink facing paper-
board for easy identification and is available in 13mm
and 16mm thicknesses with recessed edges, ready for
taping and jointing with proprietary stopping and
setting compounds.
Early Fire Hazard IndicesBGC FR Plasterboard complies with the Building Code
of Australia (BCA) Material Group Number
Classification and Deemed to Satisfy Provisions, as
determined by AS/NZS 3837: 1998 tests.
Material Classification: Group 1.
(BCA) Specification A2.4)
Suitability as Wall and Ceiling Lining In Fire-Isolated
Exits, Public Corridors, Specified and Other Areas.
(BCA Specification C1.10a Section 3(c) and Table 2:
Wall and Ceiling Linings Material Groups Permitted.
CSIRO BCE Certificate No 482
AvailabilityBGC FR Plasterboard is available in 13mm and 16mmthicknesses, 1200mm wide and in various lengths.
BGC Plasterboard ensures that the range of stock
sheet sizes listed, are available however, variations may
occur in some states, Refer Table 1.
Table 1
Widthmm
1200
1200
Thicknessmm
13mm
16mm
Masskg/m2
10.2
12.4
Lengths mm
2400
2700 3000
3600
8/6/2019 PB_FireResistance_Sep04
4/16
Page 4
ApplicationBGC FR Plasterboard wall systems are suitable for
industrial, commercial and residential applications,
both in the new construction and renovation sectors.
Load bearing and non-load bearing walls and partitions
can be clad with single or multiple layers of BGC FR
Plasterboard, with or without cavity infill insulation, to
achieve the required results for fire resistance: FRL
and acoustic properties: RW.
Non-Load Bearing WallsThe maximum wall heights for non-load bearing fire
rated walls, in this Installation Guide are for laterally
loaded walls of 0.25 kPa, as set out in Table 2 and 3
below.
The maximum stud height is based H/240 or 30mm
maximum deflection, to comply with BCA 2004
Specification 1.8 Clause 3.4.
Steel Stud Wall HeightSteel stud walls above 4.2 m in height must have a
single row of noggings, at the mid-height of the wall.
Table 2 - Non-Load Bearing Steel Stud Wall
Height Selection Table
Timber Stud Wall HeightNoggins in timber stud walls must be spaced at 1350
mm maximum centres.
Table 3 - Non-Load Bearing Timber StudWall Height Selection Table
Load Bearing WallsLoad bearing walls in this Installation Guide must be
designed and constructed in accordance with AS 1684
and AS 1720, for timber construction and AS/NZS
4600 and AS 3623 for light-weight Cold-Formed-
Formed (CFS) steel construction.
Load bearing walls must be designed and constructedto take all loads without any cladding or lining.
InstallationInstallation is to be in accordance with the BGC
Plasterboard Fixing Instruction Manual: BGC PB201
DEC 2003 and as set out in this manual.
Fire rated plasterboard must be fastener fixed to steel
and timber framing.
Stud adhesive must not be used.
For double-layered systems all joints must bestaggered and butt joints in the outer layer may be
reinforced with laminating screws.
All perimeter gaps and penetrations must be fully
sealed with fire rated mastic sealant, to attain the
required FRL and RW ratings.
64 mm
76 mm
92 mm
150 mm
0.50 mm
0.75 mm
1.15 mm
0.50 mm0.75 mm
1.15 mm
0.50 mm
0.75 mm
1.15 mm
0.75 mm
1.15 mm
Stud Gauge
BMT mm
Plasterboard Thickness mm
13 mm 16 mm
Max Wall Height m
Stud Depth
mm
3.74 m
4.16 m
4.40 m
4.16 m5.03 m
5.23 m
4.98 m
5.52 m
5.76 m
7.01 m
7.60 m
3.78 m
4.53 m
4.32 m
4.32 m5.26 m
5.26 m
5.21 m
5.73 m
5.94 m
7.20 m
7.80 m
70 mm
90 mm
120 mm
F5
F8
F11
F5
F8
F11
F5
F8
F11
Timber
Grade
Stud
Thickness
mm
35 mm45 mm35 mm45 mm
35 mm45 mm35 mm45 mm35 mm45 mm35 mm45 mm35 mm45 mm35 mm
45 mm35 mm45 mm
Stud Spacing mm
600 mm 450 mm
Max Wall Height m
Stud
Depth
mm
3.13.43.43.7
3.63.94.04.44.44.84.64.85.45.85.9
6.06.06.0
3.43.73.84.1
3.94.34.44.84.95.25.15.45.85.96.0
6.06.06.0
8/6/2019 PB_FireResistance_Sep04
5/16
Page 5
Fire-Rated Wall Cold-Formed-Section Steel Framed Construction - Non Load BearingTable 4
BGC 001
TechnicalOpinionCSIRO
FCO 2356
FR L-/60/60
Stud Depthmm
647692
150
90102118176
22.122.222.424.0
37373841
44454648
44**454649
44**454648
44454649
42.542.642.844.4
46474749
54555657
54**555657
54**555557
54555657
26.526.6
26.828.4
3839
4042
4647
4850
46**47
4850
46**47
4849
4647
4850
Wall Depthmm
Wall Masskg/m2 Nil
50mm Fibreglass24 kg/m3
75mm Fibreglass14 - 18 kg/m3
75mm Polyester8 - 10 kg/m3
Rw
Cavity Infill
One layer 13mm BGC Fire-Rated Plasterboard.
Fixed horizontally or vertically, to CFS steel stud wall
framing with noggings.
50mm Rockwool60 kg/m3
BGC 002
TechnicalOpinionCSIRO
FCO 2356
FR L-/90/90
Stud Depthmm
647692
150
116128144202
Wall Depthmm
Wall Masskg/m2 Nil
50mm Fibreglass24 kg/m3
75mm Fibreglass14 - 18 kg/m3
75mm Polyester8 - 10 kg/m3
Rw
Cavity Infill
Two layers 13mm BGC Fire-Rated Plasterboard.
First layer fixed vertically, and second layer fixed
horizontally or vertically to CFS steel stud wall framing
with noggings.
50mm Rockwool60 kg/m3
BGC 003
TechnicalOpinionCSIRO
FCO 2356
FR L-/60/60
Stud Depthmm
6476
92150
96108
124182
Wall Depthmm
Wall Masskg/m2 Nil
50mm Fibreglass24 kg/m3
75mm Fibreglass14 - 18 kg/m3
75mm Polyester8 - 10 kg/m3
Rw
Cavity Infill
One layer 16mm BGC Fire-Rated Plasterboard.
Fixed horizontally or vertically, to CFS steel stud wall
framing with noggings.
50mm Rockwool60 kg/m3
8/6/2019 PB_FireResistance_Sep04
6/16
8/6/2019 PB_FireResistance_Sep04
7/16
Page 7
BGC 007
TechnicalOpinionCSIRO
FCO 2356
FR L-/60/60
Stud Depthmm
7090
120140
102122152172
Wall Depthmm
Wall Masskg/m2 Nil
50mm Fibreglass24 kg/m3
75mm Fibreglass14 - 18 kg/m3
75mm Polyester8 - 10 kg/m3
Rw
Cavity Infill
One layer 16mm BGC Fire-Rated Plasterboard.
Fixed horizontally or vertically, to CFS timber stud wall
framing with noggings.
50mm Rockwool60 kg/m3
BGC 008
TechnicalOpinionCSIRO
FCO 2356
FR L-/120/120 Stud Depthmm7090
120140
134154184172
53.454.054.955.5
45464647
48484848
48**484849
48**484849
48484950
28.629.230.130.7
37383940
41414242
41**414243
41**414142
41414243
Wall Depthmm
Wall Masskg/m2 Nil
50mm Fibreglass24 kg/m3
75mm Fibreglass14 - 18 kg/m3
75mm Polyester8 - 10 kg/m3
Rw
Cavity Infill
Two layers 16mm BGC Fire-Rated Plasterboard.
First layer fixed vertically, and second layer fixed
horizontally or vertically to CFS Timber stud wall
framing with noggings.
50mm Rockwool60 kg/m3
Note: RW figures marked thus; ** have 50mm insulation.
8/6/2019 PB_FireResistance_Sep04
8/16
Page 8
Plasterboard and Fibre Cement Fire and Acoustic Rated Internal WallsBGC Plasterboard in conjunction with BGC Fibre Cement has Duraliner and Duratex sheets suitable for external
and internal wall applications if fire and acoustic ratings are required.
The Rw Values are opinions based on tests conducted by Acoustic Laboratories Australia and computer predicted
values using the Marshall Day Acoustics program.*Denotes actual test carried out by ALA (Acoustic Laboratories Australia) Pty Ltd.
Table 5 - Single and Staggered Stud Construction
9 mm Duraliner16 mm Fire RatedPlasterboard
64 x 35 x 0.55 mm (BMT) Steel
600 mm Centres
BGC DL001120/120/120
BRANZTest No.
FR 2755-1Stud Depth
mm
64
76
92
102
114
130
48
48
48
52*
56
58
52**
57
58
56**
57
58
57
57
58
Wall Depthmm
Wall Masskg/m2 Ni l
50mm Fibreglass12 kg/m3
75mm Fibreglass14 - 18 kg/m3
75mm Polyester12 kg/m3
Rw
Cavity Infill64mm CFS steel stud wall shown
One layer 16mm BGC Fire-Rated
Plasterboard fixed horizontally
or vertically over a layer of
9mm Duraliner fibre cement
sheets, fixed horizontally to CFS
steel stud wall framing withnoggings.
50mm Rockwool60 kg/m3
6 mm Duraliner13 mm Fire RatedPlasterboard
90 x 45 mm F5 Studs
600 mm Centres
128 mmBGC DL00260/60/60
BRANZTest No.
FR 2752-1
Stud Depthmm
90 128 46 51 51 50 48
Wall Depthmm
Wall Masskg/m2 Ni l
50mm Fibreglass12 kg/m3
75mm Fibreglass14 - 18 kg/m3
75mm Polyester12 kg/m3
Rw
Cavity Infill
One layer 6mm BGC Duraliner
fixed horizontally over a layer of13mm BGC Fire Rated
Plasterboard sheets, fixed to
timber framed wall with
noggings.
50mm Rockwool60 kg/m3
mm Duraliner13 mm Fire RatedPlasterboard
90 x 45 mm F8 Studs
600 mm Centres
128 mmBGC DL00360/60/60
BRANZTest No.
FR 2753-1
Stud Depthmm
90 128
45.5
45.6
45.8
43.8
43.8 46 51 50 50 49
Wall Depthmm
Wall Masskg/m2 Ni l
50mm Fibreglass12 kg/m3
75mm Fibreglass14 - 18 kg/m3
75mm Polyester12 kg/m3
Rw
Cavity Infill
One layer 13mm BGC Fire-Rated
Plasterboard sheets fixed over a
layer of 6mm BGC Duraliner
fixed to timber-framed wall with
noggings.
50mm Rockwool60 kg/m3
8/6/2019 PB_FireResistance_Sep04
9/16
Page 9
6 mm Duraliner16 mm Fire RatedPlasterboard
0 x 45 mm F5 Studs
00 mm Centres
134 mmBGC DL004
90/90/90
BRANZTest No.
FR 2754-1
Stud Depthmm
90 134 47 50 48
Wall Depthmm
Wall Masskg/m2 Nil
50mm Fibreglass12 kg/m3
75mm Fibreglass14 - 18 kg/m3
75mm Polyester12 kg/m3
Rw
Cavity Infill
One layer 16mm BGC FR
Plasterboard sheets fixed over a
layer of 6mm BGC Duralinerfixed to timber-framed wall with
noggings.
50mm Rockwool60 kg/m3
300 mm maxCentres
6 mm Duraliner
13 mm Fire RatedPlasterboard
70 x 45 mm F5 Studs120 mm Plates
158 mmBGC DL00560/60/60
BRANZOPINION No.FAR 1542-1
Stud Depthmm
70 158 50 57* 55
Wall Depthmm
Wall Masskg/m2 Nil
50mm Fibreglass12 kg/m3
75mm Fibreglass14 - 18 kg/m3
75mm Polyester12 kg/m3
Rw
Cavity Infill
One layer 13mm BGC FR
Plasterboard sheets fixed over
a layer of 6mm BGC Duraliner
fixed to timber-framed
staggered stud wall with
noggings.
50mm Rockwool60 kg/m3
300 mm maxCentres
6 mm Duraliner
13 mm Fire RatedPlasterboard
90 x 45 mm F8 Studs120 mm Plates
158 mmBGC DL00660/60/60
BRANZOPINION No.FAR 1542-1
Stud Depthmm
90 158
48.9
45.1
46.0 48 57
50
57
57 54
48
54
54
Wall Depthmm
Wall Masskg/m2 Nil
50mm Fibreglass12 kg/m3
75mm Fibreglass14 - 18 kg/m3
75mm Polyester12 kg/m3
Rw
Cavity Infill
One layer 6mm BGC Duraliner
sheets fixed over a layer of
13mm BGC FR Plasterboard
fixed to timber-framed
staggered stud wall with
noggings.
50mm Rockwool60 kg/m3
*The Rw values for the Duratex are opinions based on tests conducted by Acoustic Laboratories Australia.
8/6/2019 PB_FireResistance_Sep04
10/16
Page 10
7.5 mm Duratex16 mm FireRated Plasterboard
90 x 45 mmF5 Studs
450 ~ 600 mm Centres
135.5 mm
6 mm Duraliner
BGC DT001
60/60/60
Branz TestNo. FR 2924
UDL of 9 kNper stud
Stud Depthmm
90 136.5 49.5 46+ 54 55 5654
Wall Depthmm
Wall Masskg/m2 Ni l
50mm Fibreglass12 kg/m3
75mm Fibreglass14 - 18 kg/m3
75mm Polyester12 kg/m3
Rw
Cavity Infill
UDL of 9kN stud
Non-Load Bearing
UDL of 6kN stud
One layer 7.5mm BGC Duratexsheets fixed over a layer of13mm BGC FR Plasterboardfixed to the outside of the
timber-framed stud wall withnoggings.
One layer 6mm BGC Duralinersheets fixed over a layer of13mm BGC FR Plasterboard
fixed to the inside of the timber-framed stud wall.
50mm Rockwool60 kg/m3
7.5 mm Duratex
16 mm Fire
Rated Plasterboard
90 x 45 mmF5 Studs
450 ~ 600 mm Centres
135.5 mm
6 mm Duraliner
BGC DT00290/90/90
Branz TestNo. FR 2924
Non-LoadBearing
Stud Depthmm
90 136.5 49.5 46* 54 55 5654
Wall Depthmm
Wall Masskg/m2 Ni l
50mm Fibreglass12 kg/m3
75mm Fibreglass14 - 18 kg/m3
75mm Polyester12 kg/m3
Rw
Cavity Infill
One layer 7.5mm BGC Duratexsheets fixed over a layer of13mm BGC FR Plasterboardfixed to the outside of the
timber stud wall with noggings.
One layer 6mm BGC Duralinersheets fixed over a layer of13mm BGC FR Plasterboard
fixed to the inside of the timberstud wall.
50mm Rockwool60 kg/m3
7.5 mmDuratex
13 mm FireRated Plasterboard90 x 45 mm
F5 Studs
450 ~ 600 mm Centres
129.5 mm
6 mm Duraliner
Fire Resistent
BGC DT00390/90/90
BranzOpinion
FAR 1764
UDL of 6 kN
per studStud Depth
mm
90 129.5 45.1 45 45* 49 45* 4948
Wall Depthmm
Wall Masskg/m2 Ni l
50mm Fibreglass12 kg/m3
75mm Fibreglass14 - 18 kg/m3
75mm Polyester12 kg/m3
Rw
Cavity Infill
One layer 7.5mm BGC Duratexsheets fixed over a layer of13mm BGC FR Plasterboard
fixed over fire-resistant buildingpaper to the outside of the
timber-framed stud wall withnoggings.
One layer 6mm BGC Duralinersheets fixed over a layer of13mm BGC FR Plasterboard
fixed to the inside of the timberstud wall.
50mm Rockwool60 kg/m3
*The Rw values for the Duratex are opinions based on tests conducted by Acoustic Laboratories Australia.
8/6/2019 PB_FireResistance_Sep04
11/16
Page 11
Steel Frame Installation DetailsThe installation details shown figures 1 to 4 are suitable for single, double and staggered stud wall configurations.
Figure 1 Fire CFS Steel FramedConstruction Fire ResistantPlasterboard Single LayerHorizontal Installation
Figure 2 CFS Steel FramedConstruction Fire ResistantPlasterboard Single LayerVertical Installation
BGC 16mmFire Rated
PlasterboardFixed One (1) Layers
In StaggeredLay-out to Each
Face of Frame
75 x 45 Top Plate
Caulk Perimeter with Fire-Rated Mastic
Noggingat1350mmMax.Centres
Studsat600mmMaxCentres
Screwsat300mmMaxcentres
Set Joints
ScrewsFixingsat
Max300mmCentres
ScrewsFixingsStaggardat
Max200mmCentres
ScrewsFixingsat
Max300mmCentres
75 x 45 Top Plate
BGC 16mm FireRated PlasterboardFixed One (1) Layer
In Staggered Lay-outto Each Face of Frame
Noggingat1350mmMax.Ce
ntres
Studsat600mmMaxCentres
Do Not Fix to Topor Bottom Track
(non load bearing)
Maintain 6mmGapBetween Sheet and Floor
Caulk Perimeter withFire-Rated Mastic
StaggerFixingsat
Max300mmcentres
Note:All Joints Must
be Backed by Studs
Screw Fixings atMax 300 mm Centres
Fixing Specifications
Fastener Spacing Position
300mm max. centres Centre of the Board
At each stud Recessed Edges
200mm max. centres Butt Joints
300mm max. centres Corners & Openings
Fixing Specifications
Fastener Spacing Position
300mm max. centres Centre of the Board
30 0mm max. centr es Rec essed Edges
200mm max. centres Butt Joints
300mm max. centres Corners & Openings
8/6/2019 PB_FireResistance_Sep04
12/16
Page 12
Figure 3 CFS Steel Framed ConstructionFire Resistant Plasterboard Double LayerHorizontal Installation
BGC 16mm FireRated PlasterboardFixed One (1) Layers
In Staggered Lay-outto Each Face of Frame
Caulk Perimeter with Fire-Rated Mastic Nog
gingat1350mmMax.Centres
Studsat600mmMaxCentres
Set Joints
Screws Fixings atMax 300 mm Centres
Screws Fixings Staggardat Max 200 mm Centres
75 x 45 Top Plate
BGC 16mm FireRated PlasterboardFixed One (1) Layers
In Staggered Lay-outto Each Face of Frame
Caulk Perimeter with Fire-Rated Mastic
Noggingat1350mmMax.Centres
Studsat600mmMaxCentres
Set Joints
Screws Fixings atMax 300 mm Centres
75 x 45 Top Plate
Fixing Specifications
First Layer
Fastener Spacing Location
600mm max. centres Centre of the Board
At Each Stud Recessed Edges
300mm max. centres Butt Joints
600mm max. centres Corners & Openings
Second Layer
300mm max. centres Centre of the Board
At Each Stud Recessed Edges
200mm max. centres Butt Joints
600mm max. centres Corners & Openings
Fixing Specifications
First Layer
Fastener Spacing Location
600mm max. centres Centre of the Board
600mm max. centr es Recessed Edges
600mm max. centres Corners & Openings
Second Layer
300mm max. centres Centre of the Board
At Each Stud Recessed Edges
200mm max. centres Butt Joints
300mm max. centres Corners & Openings
Figure 4 CFS Steel FramedConstruction Fire ResistantPlasterboard Double Layer Vertical &Second Layer Horizontal Installation
8/6/2019 PB_FireResistance_Sep04
13/16
Page 13
Figure 5 Fire CFSTimber Framed Construction Fire ResistantPlasterboard Single Layer Horizontal Installation
Figure 6 CFSTimber Framed ConstructionFire Resistant Plasterboard Double LayerHorizontal Installation
BGC 16mm FireRated PlasterboardFixed One (1) Layer
In Staggered Lay-outto Each Face of Frame
75 x 45 Top Plate
Caulk Perimeter with Fire-Rated MasticNoggingat1350m
mMax.Centres
Studsat600mmMaxCentres
Nailsat150mmMaxCentres
Set Joints
Nails at Max
150 mm Centres
300mmMax
2Nails50mm
appartor1Screw
BGC 16mm FireRated PlasterboardFixed Two (2) Layers
In Staggered Lay-out
to Each Face of Frame
75 x 45 Top Plate
Caulk Perimeter with Fire-Rated Mastic
Noggingat1350mmMax.Centres
Studsat600mmMaxCentres
300mmM
ax
2Nails50mm
appartor1Screw
Nailsat150mmMaxCentres
Fixing Specifications
Fastener Spacing Location
2 Nails 50mm apart at
300mm max. centres
1 screw at 200mm
max. centres
Centre of the Board
At Each Stud Recessed Edges
Nails at 150mm max.
centres
Screws at 200mm
max. centres
Butt Joints
Nails at 150mm max.
centres
Screws at 200mm
max. centres
Corners & Openings
Fixing Specifications
First LayerFastener Spacing Location
Nails or Screws600mm max. centres
Centre of the Board
Nails or Screws600mm max. centres
Recessed Edges
Nails or Screws600mm max. centresin staggered pattern
Fastener Spacing Location
2 Nails 50mm apart at300mm max. centres
1 screw at 200mmmax. centres
At Each Stud
Nails at 150mm max.centres
Screws at 200mmmax. centres
Nails at 150mm max.centres
Screws at 300mmmax. centres
Centre of the Board
Recessed Edges
Butt Joints
Corners & Openings
Second Layer
Butt Joints
Timber Frame Installation DetailsThe installation details shown figures 5 to 7 are suitable for single, double and staggered stud wall configurations.
8/6/2019 PB_FireResistance_Sep04
14/16
Page 14
Fixing Specifications
First Layer
Fastener Spacing Location
Nails or Screws
600mm max. centres
Centre of the Board
Nails or Screws
600mm max. centres
Recessed Edges
Nails or Screws
600mm max. centres
in staggered pattern
Fastener Spacing Location
2 Nails 50mm apart at300mm max. centres
1 screw at 200mmmax. centres
At Each Stud
Nails at 150mm max.centres
Screws at 200mmmax. centres
Nails at 150mm max.centres
Screws at 300mmmax. centres
Centre of the Board
Recessed Edges
Butt Joints
Corners & Openings
Second Layer
Butt Joints
BGC 16mm FireRated Plasterboard
Fix Two (2) Layers(1st Vertical - 2nd Horizontal)
In Staggered Lay-outto Each Face of Frame
75 x 45 Top Plate
Caulk Perimeter withFire-Rated Mastic
Noggingat1350mmMax.Centres
Studsat600mmMaxCentres
300m
mMax
Nailsat150mmMaxCentres
Figure 7 CFS Timber FramedConstruction Fire ResistantPlasterboard Double Layer InstallationFirst Layer and Second Layer Horizontal
8/6/2019 PB_FireResistance_Sep04
15/16
Page 15
BGC (Australia) Pty LtdBGC (Buckeridge Group of Companies), has developed into a diversified industrial group with an annual turnover that
makes it one of Australias largest, privately - owned companies.
Its wide range of operations includes manufacturing, residential and commercial building, property ownership andmanagement, contract mining, bulk haulage, quarrying and insurance. It is the largest residential building company in
Western Australia, and one of the biggest in the nation.
A decentralised management structure allows each of the autonomous business units the flexibility to make individual
business decisions, along with the knowledge and backing of sound corporate experience.
The West Australian - based group has operations in each of Australias mainland states with an international reach
that extends to New Zealand and South East Asia. BGC is also exporting its products to growing markets in both
Singapore and Hong Kong.
BGC stands by its quality, commitment and capacity to provide outstanding results for any building activity.
8/6/2019 PB_FireResistance_Sep04
16/16
Head Office Perth WALot 80, Bushmead Road, Hazelmere, Western Australia, 6055
Telephone: (08) 9374 2900 Facsimile : (08) 9374 2901Postal Address: P.O. Box 1994, Midland DC, Western Australia 6936
Adelaide33 - 39 Richmond Road, Keswick, South Australia, 5035Telephone: (08) 8293 4166 Facsimile: (08) 8293 4322
Melbourne200 - 238 Maidstone Street, Altona, Victoria 3018
Telephone: (03) 9392 9444 Facsimile : (03) 9392 9404
Sydney32 - 34 Pine Road, Yennora, New South Wales 2161
Telephone: (02) 9632 2100 Facsimile : (02) 9632 2144
Brisbane45 Peterkin Street, Acacia Ridge, Queensland 4110
Telephone: (07) 3344 3444 Facsimile: (07) 3344 1168
WarrantyBGC warrants its products to be free from defects caused by faulty
manufacture or materials. If any of its products are so defective the
Company will at its option, repair or replace them, supply equivalentreplacement or reimburse the purchase price.
This warranty shall not apply to any loss or consequential loss suffered
through or resulting from defects caused by faulty manufacture or materials.
The propriety joint and coating systems are outside the control of BGC,
therefore the independent joint and coating manufacturers must give all
warranties for the jointing system performance.
For More InformationBGC Branch Officeswww.bgcplasterboard.com.au
Produced by BGC Plasterboard ABN 62 005 736 005 020
Denotes a trademark owned by BGC Australia Pty Ltd.
Supersedes all previous publications.
A Product of Advanced TechnologyAustralian Owned
& Manufactured