Paychex Safety and Loss Control Dept. FIRE EXTINGUISHER TRAINING 29 CFR 1910.157
Jan 15, 2016
Paychex Safety and Loss Control Dept.
FIRE EXTINGUISHER TRAINING
29 CFR 1910.157
Paychex Safety and Loss Control Dept.
FOUR CLASSES OF FIRES
• CLASS A FIRE EXTINGUISHERS
– Ordinary combustibles or fibrous materials.• Wood• Paper• Cloth• Rubber
– Travel distance for employees to extinguishers is 75 feet.
Paychex Safety and Loss Control Dept.
CLASS B FIRE EXTINGUISHERS
• USE ON FLAMMABLE OR COMBUSTIBLE LIQUIDS.
• Gasoline• Kerosene• Paint• Paint thinners• Propane
– Travel distance from class B hazard to any extinguisher is 50 feet.
Paychex Safety and Loss Control Dept.
CLASS C FIRE EXTINGUISHERS
• USE ON ELECTRICAL EQUIPMENT• Appliances• Switches• Panel Boxes• Power tools
– Travel distance from the class C hazard area to any fire extinguisher is 50 feet.
Paychex Safety and Loss Control Dept.
CLASS D FIRE EXTINGUISHERS
• USE ON COMBUSTIBLE METALS
• Magnesium• Titanium• Potassium • Sodium
– Travel distance from the combustible metal working area to fire extinguisher is 75 feet.
D
Paychex Safety and Loss Control Dept.
ALL FIRE EXTINGUISHERS SHALL BE MAINTAINED:
• FULLY CHARGED AND OPERABLE CONDITIONS.
• CLEAN AND FREE OF DEFECTS.• READILY ACCESSIBLE AT ALL
TIMES.
Paychex Safety and Loss Control Dept.
INSPECTION, MAINTENANCE, AND
TESTING• MONTHLY VISUAL INSPECTION.• ANNUAL MAINTENANCE CHECK.• SIX (6) YEAR TEAR DOWN
MAINTENANCE.• TWELVE (12) YEAR HYDROSTATIC TEST.• EXTINGUISHERS ARE PROMPTLY
RECHARGED.• EXTINGUISHERS ARE COMPATIBLE.
Paychex Safety and Loss Control Dept.
ALL EXTINGUISHERS MUST:
• HAVE AN INSPECTION TAG SHOWING INSPECTED WITHIN PAST 12 MONTHS.
• PIN SEALED TO THE HANDLE.• GAGE SHOWING EXTINGUISHER
FULLY CHARGED.
Paychex Safety and Loss Control Dept.
ACME FIREEXTINGUISHER
IDENTIFYING THE PROPER FIRE EXTINGUISHER
FIRE EXTINGUISHERMULTI-PURPOSEDRY CHEMICAL
Paychex Safety and Loss Control Dept.
USING THE FIRE EXTINGUISHER
CHECK THE GAUGE
ACME FIREEXTINGUISHER
Paychex Safety and Loss Control Dept.
USING THE FIRE EXTINGUISHER
PULL THE PIN
Continued
ACME FIREEXTINGUISHER
Paychex Safety and Loss Control Dept.
USING THE FIRE EXTINGUISHER
SQUEEZE THE TRIGGER WHILE HOLDING THE EXTINGUISHER UPRIGHT.
Continued
ACME FIREEXTINGUISHER
Paychex Safety and Loss Control Dept.
ContinuedUSING THE FIRE EXTINGUISHER
AIM THE EXTINGUISHER AT THE BASE OF THE FLAMES.
SWEEP SIDE TO SIDE.
Paychex Safety and Loss Control Dept.
TO REMEMBER: USE THE PASS METHOD
•P ULL THE PIN
•A IM THE HANDLE
•S QUEEZE THE HANDLE
•S WEEP FROM SIDE TO SIDE
Paychex Safety and Loss Control Dept.
WHAT TO DO IF YOU SEE A FIRE
• PULL FIRE ALARM OR OTHER MEANS TO EVACUATE BUILDING
• CALL FOR HELP (911)• NEVER ATTEMPT TO FIGHT A FIRE.
Paychex Safety and Loss Control Dept.
WHEN SHOULD YOU NOT FIGHT A FIRE
If you have no escape route.
If the fire begins to significantly spread.
If the extinguisher proves to be ineffective.
If there is a choice between life and property.
If you’re unsure if you can handle the situation.
If you are injured and it will impede your escape.
If the extinguisher is not designed for the type fire.
If any drums, gases, and like materials are engulfed.
Paychex Safety and Loss Control Dept.
WHEN SHOULD YOU USE A FIRE EXTINGUISHER
• YOU HAVE BEEN FULLY TRAINED.• IF YOU FEEL YOU CAN HANDLE
THE SITUATION.• USE ONLY AS A LAST RESORT!
Paychex Safety and Loss Control Dept.
QUESTIONS