Top Banner
tient with loop-configuration PTFE hemodialysis gra ents with severe pain and ecchymosis of her left fo arlier today the dialysis nurse had difficulty when cannulating the arterial limb of her graft
12

Patient with loop-configuration PTFE hemodialysis graft presents with severe pain and ecchymosis of her left forearm Earlier today the dialysis nurse had.

Dec 23, 2015

Download

Documents

Stuart Shields
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Patient with loop-configuration PTFE hemodialysis graft presents with severe pain and ecchymosis of her left forearm Earlier today the dialysis nurse had.

Patient with loop-configuration PTFE hemodialysis graftpresents with severe pain and ecchymosis of her left forearm

Earlier today the dialysis nurse had difficulty when cannulating the arterial limb of her graft

Page 2: Patient with loop-configuration PTFE hemodialysis graft presents with severe pain and ecchymosis of her left forearm Earlier today the dialysis nurse had.

Active extravasation from the arterial limbdue to traumatic needle cannulation

Page 3: Patient with loop-configuration PTFE hemodialysis graft presents with severe pain and ecchymosis of her left forearm Earlier today the dialysis nurse had.

9 Fr. introducer sheath

stent graft (7mm)

Using an angioplasty balloon to seal the endsof a 7mm x 4cm stent graft

Page 4: Patient with loop-configuration PTFE hemodialysis graft presents with severe pain and ecchymosis of her left forearm Earlier today the dialysis nurse had.

Following deployment of stent graft

Page 5: Patient with loop-configuration PTFE hemodialysis graft presents with severe pain and ecchymosis of her left forearm Earlier today the dialysis nurse had.

The patient also had a venous anastomotic stenosis

Page 6: Patient with loop-configuration PTFE hemodialysis graft presents with severe pain and ecchymosis of her left forearm Earlier today the dialysis nurse had.

Pre-PTA

Post-PTA

Page 7: Patient with loop-configuration PTFE hemodialysis graft presents with severe pain and ecchymosis of her left forearm Earlier today the dialysis nurse had.

Duplication of left basilic veins

Page 8: Patient with loop-configuration PTFE hemodialysis graft presents with severe pain and ecchymosis of her left forearm Earlier today the dialysis nurse had.

Left central veins

Page 9: Patient with loop-configuration PTFE hemodialysis graft presents with severe pain and ecchymosis of her left forearm Earlier today the dialysis nurse had.

Patient returns three weeks later with developmentof small pseudoaneurysm arising from venous limb;the previous site of insertion of 8 Fr vascular sheath

Page 10: Patient with loop-configuration PTFE hemodialysis graft presents with severe pain and ecchymosis of her left forearm Earlier today the dialysis nurse had.

pseudoaneurysm

Page 11: Patient with loop-configuration PTFE hemodialysis graft presents with severe pain and ecchymosis of her left forearm Earlier today the dialysis nurse had.

venousstenosis

pseudoaneurysm

pseudoaneurysm

Page 12: Patient with loop-configuration PTFE hemodialysis graft presents with severe pain and ecchymosis of her left forearm Earlier today the dialysis nurse had.

The development of the small pseudoaneurysmis likely due to continued elevation of intragraft pressure

from the persistent venous anastomotic stenosis.

The pseudoaneurysm is located at the site of insertionof the large diameter (8 Fr) vascular sheath which was

used during insertion of the stent graft for repair of theacute injury in the arterial limb of the graft.

The patient is schedule to undergo surgical revisionof the venous anastomotic stenosis in 9 days.

this should reduce the intragraft pressure and removethe impetus for further enlargement of the pseudoaneurysm