-
SINUMERIK
SINUMERIK 840D sl, SINAMICS S120List manual 1
Parameter Manual
Validfor SINUMERIK840Dsl/840DEslcontrol Software
versionCNCsoftware 2.7SINAMICSS120 2.6SP3
02/20116FC5397-7AP40-0BA0
Preface
Machine and setting data 1
SINAMICS parameters 2
Appendix A A
-
Legal information- Warning notice system
Legal informationWarning notice system
This manual contains notices you have to observe in order to
ensure your personal safety, as well as to prevent damage to
property. The notices referring to your personal safety are
highlighted in the manual by a safety alert symbol, notices
referring only to property damage have no safety alert symbol.
These notices shown below are graded according to the degree of
danger.
If more than one degree of danger is present, the warning notice
representing the highest degree of danger will be used. A notice
warning of injury to persons with a safety alert symbol may also
include a warning relating to property damage.
Qualified PersonnelThe product/system described in this
documentation may be operated only by personnel qualified for the
specific task in accordance with the relevant documentation for the
specific task, in particular its warning notices and safety
instructions. Qualified personnel are those who, based on their
training and experience, are capable of identifying risks and
avoiding potential hazards when working with these
products/systems.
Proper use of Siemens productsNote the following:
TrademarksAll names identified by are registered trademarks of
the SiemensAG. The remaining trademarks in this publication may be
trademarks whose use by third parties for their own purposes could
violate the rights of the owner.
Disclaimer of LiabilityWe have reviewed the contents of this
publication to ensure consistency with the hardware and software
described. Since variance cannot be precluded entirely, we cannot
guarantee full consistency. However, the information in this
publication is reviewed regularly and any necessary corrections are
included in subsequent editions.
DANGERindicates that death or severe personal injury will result
if proper precautions are not taken.
WARNINGindicates that death or severe personal injury may result
if proper precautions are not taken.
CAUTIONwith a safety alert symbol, indicates that minor personal
injury can result if proper precautions are not taken.
CAUTIONwithout a safety alert symbol, indicates that property
damage can result if proper precautions are not taken.
NOTICEindicates that an unintended result or situation can occur
if the corresponding information is not taken into account.
WARNINGSiemens products may only be used for the applications
described in the catalog and in the relevant technical
documentation. If products and components from other manufacturers
are used, these must be recommended or approved by Siemens. Proper
transport, storage, installation, assembly, commissioning,
operation and maintenance are required to ensure that the products
operate safely and without any problems. The permissible ambient
conditions must be adhered to. The information in the relevant
documentation must be observed.
Siemens AGIndustry SectorPostfach 48 4890026 NRNBERGGERMANY
order number:6FC5397-7AP40-0BA0 03.2011
Copyright SiemensAG2011.Technical data subject to change
-
Preface
SINUMERIK documentationThe SINUMERIK documentation is organized
in the following categories:
General documentation
User documentation
Manufacturer/service documentation
Additional informationYou can find information on the following
topics at www.siemens.com/motioncontrol/docu:
Ordering documentation/overview of documentation
Additional links to download documents
Using documentation online (find and search in
manuals/information)
Please send any questions about the technical documentation
(e.g. suggestions for improvement, corrections) to the following
address:
[email protected]
My Documentation Manager (MDM)Under the following link you will
find information to individually compile OEM-specific machine
documentation based on the Siemens content:
www.siemens.com/mdm
Training For information about the range of training courses,
refer under:
www.siemens.com/sitrain
SITRAIN - Siemens training for products, systems and solutions
in automation technology www.siemens.com/sinutrain
SinuTrain - training software for SINUMERIK
FAQsYou can find Frequently Asked Questions in the
Service&Support pages under Product Support.
http://support.automation.siemens.com
List manual 1Parameter Manual 02/2011, 6FC5397-7AP40-0BA0 3
http://www.siemens.com/motioncontrol/docu:mailto:[email protected]://www.siemens.com/mdmhttp://www.siemens.com/sitrainhttp://www.siemens.com/sinutrainhttp://support.automation.siemens.com
-
Preface
SINUMERIKYou can find information on SINUMERIK under the
following link:
www.siemens.com/sinumerik
Target groupThis publication is intended for project engineers,
commissioning engineers, machine operators and service and
maintenance personnel.
BenefitsThe intended target group can use the Parameter Manual
to test and commission the system or the plant correctly and
safely.
Utilization phase: Setup and commissioning phase
Standard scopeThis documentation describes the functionality of
the standard scope. Extensions or changes made by the machine
manufacturer are documented by the machine manufacturer.
Other functions not described in this documentation might be
executable in the control. This does not, however, represent an
obligation to supply such functions with a new control or when
servicing.
Furthermore, for the sake of clarity, this documentation does
not contain all detailed information about all types of the product
and cannot cover every conceivable case of installation, operation
or maintenance.
Technical Support You will find telephone numbers for other
countries for technical support in the Internet under
http://www.siemens.com/automation/service&support
List manual 14 Parameter Manual, 02/2011, 6FC5397-7AP40-0BA0
http://www.siemens.com/automation/service&supporthttp://www.siemens.com/sinumerik
-
Table of contents
Preface.........................................................................................................................................................3
1 Machine and setting data
............................................................................................................................7
1.1 Explanation of the machine/setting
data......................................................................................
71.1.1 Information about the data tables
................................................................................................
71.1.2 Structure of the data tables
.........................................................................................................
71.1.3 Meaning of table fields
.................................................................................................................
81.1.4 Number ranges of the machine and setting data
.......................................................................
141.1.5 Structure of the data tables of SINAMICS parameters
..............................................................
171.1.6 Meaning of the table fields of SINAMICS parameters
...............................................................
171.1.7 Overview of the number ranges of parameters
.........................................................................
22
1.2 Display machine data
................................................................................................................
24
1.3 NC machine
data.......................................................................................................................
261.3.1 General machine data
...............................................................................................................
261.3.2 Channel-specific machine data
.................................................................................................
851.3.3 Axis-specific machine data
......................................................................................................
158
1.4 NC setting
data........................................................................................................................
201
1.5 Machine and setting data for SINUMERIK Operate and cycles
.............................................. 218
1.6 Compile cycles
........................................................................................................................
252
2 SINAMICS parameters
...........................................................................................................................261
A Appendix A
..............................................................................................................................................885
A.1 List of
abbreviations.................................................................................................................
885
A.2 Documentation overview
.........................................................................................................
890
List manual 1Parameter Manual 02/2011, 6FC5397-7AP40-0BA0 5
-
Table of contents
List manual 16 Parameter Manual, 02/2011, 6FC5397-7AP40-0BA0
-
1Machine and setting data1.1 Explanation of the machine/setting
data
1.1.1 Information about the data tablesThis list manual provides
information on all the machine and setting data in a tabular
format.
A functional description of the data is provided in the Function
Manual indicated in the cross reference.
For additional descriptionsMore detailed information is
available in:
Online help directly at the control
DOConCD:
- Description of the detailed machine data, 840D sl- SINAMICS
S120/S150 List Manual
1.1.2 Structure of the data tables
Standard tableThe standard table contains all the important
information about the data.
MD number Identifier Display filter ReferenceUnits Name Data
type EffectivenessAttributesSystem Dimension Default value Minimum
value Maximum value Protection Class
List manual 1Parameter Manual 02/2011, 6FC5397-7AP40-0BA0 7
-
Machine and setting data 1.1 Explanation of the machine/setting
data
Expanded tableThe expanded table includes data from the standard
table plus additional rows with system-specific values.
A minus sign "-" in a field means that the same value as for
applies for the specified system.
The entry "-/-" in the "Protection" field means that the machine
data is not available for the specified system.
Example:
1.1.3 Meaning of table fields
MD numberThe "MD number" field contains the machine data number.
This number is displayed in the data lists on the user interface of
the control.
IdentifierThe "Identifier" field contains the unique
alphanumeric identifier of the machine data. The machine data is,
for example, addressed by means of this identifier (with an
additional label) for programming in the part program.
This identifier is displayed in the data lists on the user
interface of the control.
MD number Identifier Display filter ReferenceUnits Name Data
type EffectivenessAttributes- Dimension Default value Minimum value
Maximum value Protecti
onClass
- - - - -/- - - - - -1/-
18353 MM_M_FILE_MEM_SIZE EXP, N02 S7- Memory size for
cycles/files of the machine manufacturer DWORD POWER ON
840dsl-71 3 2560,0,0 0 9216 2/2 M840dsl-72 3 2560,0,0 0 15360
2/2 M840dsl-73 3 2560,0,0 0 15360 2/2 M
List manual 18 Parameter Manual, 02/2011, 6FC5397-7AP40-0BA0
-
Machine and setting data1.1 Explanation of the machine/setting
data
ReferenceAs a cross reference to the functional description of
the data, the "Reference" field contains the short designation of
the corresponding submanual of a function manual.
Reference is made to the following submanuals:
Function Manual Basic Functions, submanuals: A2, A3, B1, B2, D1,
F1, G2, H2, K1, K2, N2, P1, P3, P4, R1, S1, V1, W1, Z1
Function Manual Extended Functions, submanuals: A4, B3, B4, H1,
K3, K5, M1. M5, N3, N4, P5, P2, R2, S3, S7, T1, W3, W4, Z2
Function Manual Special Functions, supporting manuals: F2, G1,
G3, K6, M3, R3, S9, T3, TE01, TE1, TE3, TE4, TE6, V2, W5, Z3
Function Manual Safety Integrated, FBSI
Function Manual Tool Management, FBWsl
Function description, ISO Dialects for SINUMERIK, FBFA
Units/system of unitsDepending on MD10240
$MN_SCALING_SYSTEM_IS_METRIC, the physical units differ as
follows:
If the MD is not based on any physical unit, the field is marked
with "-".
NameThe "Name" field contains the name of the data in plain
text.
MD10240=1 MD10240=0mm inchmm/min inch/min
m/sec2 inch/sec2
m/sec3 Inch/sec3
mm/rev. inch/rev.
NoteThe default setting is MD10240 $MN_SCALING_SYSTEM_IS_METRIC
= 1 (metric)
List manual 1Parameter Manual, 02/2011, 6FC5397-7AP40-0BA0 9
-
Machine and setting data 1.1 Explanation of the machine/setting
data
EffectivenessThe "Activation" field contains the action that
must be performed by the user in order for a change to take
effect.
The activation levels are listed according to their
priority.
po = highest priority
so = lowest priority
ProtectionThe "Protection" field contains the protection level
for reading or writing to the data in the form: Read/write.
The protection level for user data (GUD) is defined with the
numbers 10 to 17.
Effectiveness User actionpo POWER ON Alternatively:
"Reset(po)" softkey Switch voltage off/on
cf NEW_CONF Softkey: "Activate MD"re RESET Alternatively:
"Reset(po)" softkey Program end reset (M02/M30)
so IMMEDIATELY After entering the value
Value Protection level0 or 10 System1 or 11 Manufacturer2 or 12
Service3 or 13 User4 or 14 Key-operated switch position 35 or 15
Key-operated switch position 26 or 16 Key-operated switch position
17 or 17 Key-operated switch position 0
List manual 110 Parameter Manual, 02/2011,
6FC5397-7AP40-0BA0
-
Machine and setting data1.1 Explanation of the machine/setting
data
ClassThe data class attributes of machine, setting and option
data are normally derived from the write rights of the
corresponding data.
The following data classes are available:
Display filterThe "Display filter" field contains the identifier
of the data filter setting that enables the data to be seen. Using
the filter setting, the exact data areas required at a given time
can be selected for display.
Data class Write rights Access rightS (System) System Protection
level 0 (password: System)M (Manufacturer) Manufacturer/Service
Protection levels 1 and 2 (password: Service)I
(Individual)Note:Individual machine data are grouped in this data
class, e.g. the leadscrew error compensation values. Depending on
the contents, these are accessible via different protection
levels.
Manufacturer/ServiceorUser
Protection levels 1 and 2 (password: Service)orProtection level
3 (user password)
U (User) User Protection level 3 (password: User)Protection
levels 4 and 7 (key-operated switch)
ID Data areaEXP Expert modeDrive machine dataD00 Display
signalsD01 Controller dataD02 Monitoring/limiting functionsD03
Message dataD04 Status dataD05 Motor/power unitD06 Measuring
systemD07 Safety IntegratedD08 Standard machineGeneral machine
dataN01 Configuration/scalingN02 Memory configurationN03 PLC
machine data N04 Drive controlN05 Status data/diagnosticsN06
Monitoring/limiting functionsN07 Auxiliary functions
List manual 1Parameter Manual, 02/2011, 6FC5397-7AP40-0BA0
11
-
Machine and setting data 1.1 Explanation of the machine/setting
data
N08 Corrections/compensationsN09 Technological functionsN10 I/O
configuration N11 Standard machineA12 NC language, ISO
dialectChannel-specific machine dataC01 ConfigurationC02 Memory
configurationC03 Initial statesC04 Auxiliary functionsC05
VelocitiesC06 Monitoring/limiting functionsC07 TransformationsC08
Corrections/compensationsC09 Technological functions C10 Standard
machineC11 NC language, ISO dialectAxis-specific machine dataA01
Configuration (including memory) A02 Measuring systemA03 Machine
geometryA04 Velocities / accelerationsA05 Monitoring/limiting
functionsA06 SpindleA07 Controller dataA08 Status dataA09
Corrections/compensationsA10 Technological functionsA11 Standard
machineA12 NC language, ISO dialectDisplay machine dataH01
ShopMillH02 ShopTurnH03 ManualTurnH04 Access levelsH05 Standard
machine
ID Data area
List manual 112 Parameter Manual, 02/2011,
6FC5397-7AP40-0BA0
-
Machine and setting data1.1 Explanation of the machine/setting
data
Default valueThe "Default value" field contains the value that
is used to preset the machine data.
Some machine data is preset with different default values,
depending on the NCU that is used.
SystemIn the "System" field, the control system is specified for
which the data with the correspondingly entered values applies.
The following entries are possible:
If this field is empty, the data is valid for all systems.
DimensionThe "Dimension" field contains the number of elements
of a data field.
Range of valuesThe "Minimum value" and "Maximum value" fields
contain the lower limit and upper limit, respectively, of the
permissible range of the data.
If the "Minimum value" and "Maximum value" fields contain the
string " *** ", an explicit range is not defined for this data. In
this case, the range is determined by the specified data type.
SINUMERIK data typesThe "Data type" field contains the following
data types:
NoteWhen input via the user interface, this is limited to ten
digits plus comma and sign.
840dsl-71 NCU710840dsl-72 NCU720840dsl-73 NCU730
Data type Range of valuesBOOLEAN Machine data bit (1 or 0)BYTE
Integer values ( -128 to 127 )DOUBLE Real values ( ( 2.2 * 10-308
to 1.8 * 10+308 ) )DWORD Integer values ( -2147483648 to
+2147483647 )DWORD Hex values ( 0 to FFFF FFFF )STRING Character
string (max. 16 characters) consisting of upper-case letters
with digits and underscoreUNSIGNED WORD Integer values ( 0 to
65536 )SIGNED WORD Integer values ( -32768 to 32767 )
List manual 1Parameter Manual, 02/2011, 6FC5397-7AP40-0BA0
13
-
Machine and setting data 1.1 Explanation of the machine/setting
data
AttributesThe "Attributes" field contains additional attributes
of the data:
1.1.4 Number ranges of the machine and setting data
Number ranges (SINUMERIK)The machine and setting data are
divided into the following number ranges:
UNSIGNED DWORD Integer values ( 0 to 4294967300 )SIGNED DWORD
Integer values ( -2147483650 to 2147483649 )WORD Hex values ( 0000
to FFFF )FLOAT DWORD Real values ( ( 8.43 x 10-37 to "3.37 x 1038
)UBYTE Integer values ( 0 to 255 )LONG Integer values ( 4294967296
to 4294967295 )
Data type Range of values
Attribute MeaningNBUP No Back UP: The data is not backed up as
part of the data backup.ODLD Only DownLoaD: The data can only be
written to via an ini file, archive,
or from the part program.NDLD No DownLoaD: The data can only be
written to via the user interface.SFCO SaFety COnfiguration:
Component of the "Safety Integrated".SCAL SCaling ALarm: Scaling
data; when changed, alarm 4070 is displayedLINK LINK description:
The data describes a link cluster, component of the
"NCU Link" functionCTEQ ConTainer EQual: The data must be the
same for all axes in an axis
container, component of the "Axis container" functionCTDE
ConTainer DEscription: The data describes an axis container,
component of the "Axis container" function
RangeDescription
From to9000 9999 Display machine data10000 18999 General NC
machine data and
general machine data for Safety Integrated19000 19999
Reserved20000 28999 Channel-specific machine data29000 29999
Reserved3 0 0 0 0
38999 Axis-specific machine data andaxis-specific machine data
for Safety Integrated
39000 39999 Reserved
List manual 114 Parameter Manual, 02/2011,
6FC5397-7AP40-0BA0
-
Machine and setting data1.1 Explanation of the machine/setting
data
Data IdentifiersThe identifier specified in the data description
is displayed on the user interface. However, if the data is
addressed in the part program, for example, the identifier of the
relevant data area must precede the data identifier.
Example: $MA_JOG_VELO[Y1]=2000
The JOG velocity of axis Y1 is 2000 mm/min.
If the content of a machine data is a STRING (e.g. X1) or a
hexadecimal value (e.g. H41) the contents must lie between " ' "
(e.g. 'X1' or 'H41').
41000 41999 General setting data42000 42999 Channel-specific
setting data43000 43999 Axis-specific setting data51000 51299
General configuration machine data51300 51999 General cycle machine
data52000 52299 Channel-specific configuration machine data52300
52999 Channel-specific cycle machine data53000 53299 Axis-specific
configuration machine data53300 53999 Axis-specific cycle machine
data
RangeDescription
From to
Identifier Data area$MM_ Display machine data$MN_/ $SN_$MNS_/
$SNS_
General machine/setting data
$MC_/ $SC_$MCS_/ $SCS_
Channel-specific machine/setting data
$MA_/ $SA_$MAS_/ $SAS_
Axis-specific machine/setting data
Characters Meanings$ System variablesM Machine data (first
letter)S Setting data (first letter)M, N, C, A, D Subarea (second
letter)S Siemens data (third letter)
NoteAxis-specific data can also be addressed with the axis name
as an index. The internal axis identifier (AX1, AX2, AX3, etc.) or
the identifier specified in MD10000 $MA_AX_CONF_NAME_TAB can be
used as the axis name.
List manual 1Parameter Manual, 02/2011, 6FC5397-7AP40-0BA0
15
-
Machine and setting data 1.1 Explanation of the machine/setting
data
Example: $MN_DRIVE_INVERTER_CODE[0]='H14'
A feed drive (FD) module with a power rating of 9/18 A is
inserted in the first slot of the drive bus.
Example: $MA_FIX_POINT_POS[0,X1]=500.000
The value 500 is assigned to the first fixed point position on
axis 1.
Examples:
$MN_AUXFU_GROUP_SPEC[2]='H41'
Output instant in time of the auxiliary functions of the 3rd
auxiliary function group.
$MN_AXCONF_MACHAX_NAME_TAB[0]='X1'String "X1" is assigned as
name for the first machine axis.
$MA_REFP_SET_POS[0,X1]=100.00000
A value of 100 mm is assigned to the first reference point of
axis X1.
Examples:
Assignment to channel-specific machine data:
CHANDATA(1) ; Selection of the first
channel$MC_CHAN_NAME='CHAN1' ; Name of the first
channel$MC_AXCONF_GEOAX_NAME_TAB[1]='Y' ; Name of the 2nd geometry
axis
; of the first channel 'Y'R10=33,75 ; R10 of the first
channel
List manual 116 Parameter Manual, 02/2011,
6FC5397-7AP40-0BA0
-
Machine and setting data1.1 Explanation of the machine/setting
data
1.1.5 Structure of the data tables of SINAMICS parameters
Basic structure of the parameter descriptionThe tables of
SINAMICS parameters all have the following standard structure:
Example
ReferencesYou can find a detailed description of SINAMICS
parameters in the following document:
SINAMICS S120/S150 List Manual
1.1.6 Meaning of the table fields of SINAMICS parameters
Parameter number pxxxx[0...n]The "parameter number" field
contains the number of the parameter.
The number consists of a leading "p" or "r", followed by the
parameter number and the index (optional).
Parameter number
BICO: Full parameter name / short parameter name
Drive object(function module)
Can be changed: Calculated: Access level:Data type: Dynamic
index: Function diagram:P group: Unit group: Unit selection:Not for
motor type: Normalizing Expert list:Min. Max. Factory setting
r0025[0...3] CO: Input voltage, smoothedA_INF, S_INF Can be
changed: - Calculated: - Access level: 2
Data type: FloatingPoint32 Dynamic index: Function diagram:
8850P group: Display, signals Unit group: - Unit selection: -Not
for motor type: - Normalization p2001 Expert list: 1Min- [Vrms]
Max- [Vrms]
Factory setting- [Vrms]
p... Adjustable parameter (read and write parameter)r... Display
parameter (read-only)p0918 Adjustable parameter 918p0099[0...3]
Adjustable parameter 99, indices 0 to 3
List manual 1Parameter Manual, 02/2011, 6FC5397-7AP40-0BA0
17
-
Machine and setting data 1.1 Explanation of the machine/setting
data
BICO: Full parameter name / short parameter nameThe following
abbreviations can appear in front of the parameter name:
Drive object (function module)A drive object (DO) is an
independent, "self-contained" functional unit with its own
parameters, faults messages, and alarms.
The parameter list specifies the associated drive object and
function module for each individual parameter.
Can be changedThe "-" sign indicates that the parameter can be
changed in any object state and that the change will be effective
immediately.
The information C1(x), C2(x), T, U ((x): optional) means that
the parameter can be changed only in the specified drive object
state and that the change will not take effect until the object
switches to another state. This can be one or more states.
The following states are available:
p1001[0...n] Adjustable parameter 1001, indices 0 to n (n =
configurable)r0944 Display parameter 944
BI Binector Input This parameter selects the source of a digital
signal.
BO Binector Output This parameter is available as an digital
signal for interconnection with other parameters.
CI Connector Input This parameter selects the source of an
"analog" signal.
CO Connector Output This parameter is available as an "analog"
signal for interconnection with other parameters.
CO/BO Connector/Binector Output This parameter is available as
both an "analog" and also as digital signals for interconnection
with other parameters.
List manual 118 Parameter Manual, 02/2011,
6FC5397-7AP40-0BA0
-
Machine and setting data1.1 Explanation of the machine/setting
data
CalculatedSpecifies whether the parameter is influenced by
automatic calculations. The calculation attribute defines which
activities influence the parameter.
Access levelSpecifies the access level required to be able to
display and change this parameter. The required access level can be
set using p0003.
Parameters with the following access level are
password-protected:
1. Standard
2. Extended
3. Expert
4. Service
Parameters with the following access level can only be changed
via macro:
5. Macro
C1(x) Commissioning device C1 C1: Commissioning 1Device is in
the process of being commissioned (p0009 > 0).The pulses cannot
be enabled.The parameter can only be changed in the following
device commissioning settings (p0009 > 0):C1: can be changed for
all settings p0009 > 0.C1(x): can only be changed for the
settings p0009 = x.A modified parameter value does not take effect
until the device commissioning mode is exited with p0009 = 0.
C2(x) Drive object commissioning C2: Commissioning 2The drive is
in the process of being commissioned (p0009 = 0 and p0010 >
0).The pulses cannot be enabled.The parameter can only be changed
in the following device commissioning settings (p0010 > 0):C2:
can be changed for all settings p0010 > 0.C2(x): can be changed
for the settings p0010 = x. A modified parameter value does not
take effect until drive commissioning mode is exited with p0010 =
0
U Operation U: RunThe pulses are enabled
T Ready T: Ready to runThe pulses are not enabled Status "C1(x)"
or "C2(x)" is not active.
List manual 1Parameter Manual, 02/2011, 6FC5397-7AP40-0BA0
19
-
Machine and setting data 1.1 Explanation of the machine/setting
data
Data typeThe information on the data type can consist of the
following two items (separated by a slash).
First informationData type of the parameter.
Second information (for binector or connector input only)Data
type of the signal source to be interconnected (binector/connector
output).
Parameters can have the following data types:
Dynamic index:For parameters with a dynamic index [0 to n], the
following information is specified:
Data set (if available).
Parameter for the number of indices (n = number -1).
Function diagram:The parameter is included in this function
diagram. The structure of the parameter function and its
relationship with other parameters are shown in the function
diagram.
P group:Specifies the functional group to which this parameter
belongs. The required parameter group can be set via p0004.
Unit, unit group, unit selection:The standard unit of a
parameter is specified in square brackets after the values for
"Min", "Max", and "Factory setting".
For parameters where the unit can be changed, "Unit Group" and
"Unit Selection" specify which group this parameter belongs and
which parameter can be used to change the unit.
I8 Integer8 8-bit integer numberI16 Integer16 16-bit integer
numberI32 Integer32 32-bit integer numberU8 Unsigned8 8 bits
without signU16 Unsigned16 16 bits without signU32 Unsigned32 32
bits without signFloat FloatingPoint32 32-bit floating point
number
List manual 120 Parameter Manual, 02/2011,
6FC5397-7AP40-0BA0
-
Machine and setting data1.1 Explanation of the machine/setting
data
Not for motor type:Specifies for which motor type this parameter
has no significance
NormalizingSpecification of the reference variable with which a
signal value is automatically converted for a BICO
interconnection.
The following reference variables are possible:
Expert list:Specifies whether this parameter is available in the
expert list of the specified drive objects in the commissioning
software.
Min, max, factory setting
ASM Induction motorFEM Separately excited synchronous motorPEM
Permanent-magnet synchronous motorREL Reluctance motor/SIEMOSYN
motor
p2000 ... p2007: Reference speed, reference voltage, etc.TEMP:
100C = 100%PERCENT: 1.0 = 100%4000H: 4000 hex = 100 %
1: Parameter does exist in the expert list.0: Parameter does not
exist in the expert list.
Min. Minimum value of the parameter [unit]Max. Maximum value of
the parameter [unit]Factory setting Value when supplied [unit]
List manual 1Parameter Manual, 02/2011, 6FC5397-7AP40-0BA0
21
-
Machine and setting data 1.1 Explanation of the machine/setting
data
1.1.7 Overview of the number ranges of parameters
Number ranges (SINAMICS)Parameters are grouped into the
following number ranges:
RangeDescription
From to0000 0099 Display and operation0100 0199
Commissioning0200 0299 Power unit0300 0399 Motor0400 0499
Encoder0500 0599 Technology and units, motor-specific data,
probes0600 0699 Thermal monitoring, maximum current, operating
hours, motor data,
central probe0700 0799 Control Unit terminals, measuring
sockets0800 0839 CDS, DDS data sets, motor changeover0840 0879
Sequence control (e.g. signal source for ON/OFF1)0880 0899 ESR,
parking, control and status words0900 0999 PROFIBUS/PROFIdrive1000
1199 Setpoint channel (e.g. ramp-function generator)1200 1299
Functions (e.g. motor holding brake)1300 1399 U/f control1400 1799
Closed-loop control1800 1899 Gating unit1900 1999 Power unit and
motor identification2000 2009 Reference values2010 2099
Communication (fieldbus)2100 2139 Faults and alarms2140 2199
Signals and monitoring2200 2359 Technology controller2360 2399
Staging, hibernation2500 2699 Position control (LR) and basic
positioning (EPOS)2700 2719 Reference values, display2720 2729 Load
gearbox2800 2819 Logic operations2900 2930 Fixed values (e.g.
percent, torque)3000 3099 Motor identification results3100 3109
Real-time clock (RTC)3110 3199 Faults and alarms3200 3299 Signals
and monitoring3400 3659 Infeed closed-loop control
List manual 122 Parameter Manual, 02/2011,
6FC5397-7AP40-0BA0
-
Machine and setting data1.1 Explanation of the machine/setting
data
3660 3699 Voltage Sensing Module (VSM), Braking Module
internal3700 3779 Advanced Positioning Control (APC)3780 3819
Synchronization3820 3849 Friction characteristic3850 3899 Functions
(e.g. long stator)3900 3999 Management4000 4599 Terminal Board,
Terminal Module (e.g. TB30, TM31)4600 4699 Sensor Module4700 4799
Trace4800 4849 Function Generator4950 4999 OA application5400 5499
Line droop control (e.g. shaft generator)5500 5599 Dynamic grid
support (solar)5900 6999 SINAMICS GM/SM/GL/SL7000 7499 Parallel
connection of power units7500 7599 SINAMICS SM1207700 7729 External
messages7770 7789 NVRAM, system parameters7800 7839 EEPROM
read/write parameters7840 8399 Internal system parameters8400 8449
Real-time clock (RTC)8500 8599 Data and macro management8600 8799
CAN bus8800 8899 Communication Board Ethernet (CBE), PROFIdrive8900
8999 Industrial Ethernet, PROFINET, CBE209000 9299 Topology9300
9399 Safety Integrated9400 9499 Parameter consistency and
storage9500 9899 Safety Integrated9900 9949 Topology9950 9999
Diagnostics, internal10000 10199 Safety Integrated11000 11299 Free
technology controller 0, 1, 220000 20999 Free function blocks
(FBLOCKS)21000 25999 Drive Control Chart (DCC) 50000 53999 SINAMICS
DC MASTER (DC closed-loop control)61000 61001 PROFINET
RangeDescription
From to
List manual 1Parameter Manual, 02/2011, 6FC5397-7AP40-0BA0
23
-
Machine and setting data 1.2 Display machine data
1.2 Display machine data
Product: Handbuch_Sinumerik, Version: V13.0, Language:
engObjects:
Number Identifier Display filters ReferenceUnit Name Data type
ActiveAttributesSystem Dimension Default value Minimum value
Maximum value Protection Class
9006 DISPLAY_SWITCH_OFF_INTERVAL - -- Time for screen saver
DWORD PowerOn-- - 60 0 180 7/3 M
9009 KEYBOARD_STATE - -- Keyboard shift behavior at booting BYTE
PowerOn-- - 0 0 2 7/3 M
9032 HMI_MONITOR - -- Define PLC data for HMI screen info STRING
PowerOn-- - - - 7/1 M
9056 ALARM_ROTATION_CYCLE - -- Rotation cycle time for alarm
display DWORD PowerOn-- - 0 0 10000 7/3 M
9100 CHANGE_LANGUAGE_MODE - -- Language selection mode BYTE
Immediately-- - 1 1 2 7/3 I
9102 SHOW_TOOLTIP - -- Display tooltip BYTE Immediately-- - 1 0
1 7/3 U
9103 TOOLTIP_TIME_DELAY - -s Time delay tooltip display BYTE
Immediately-- - 1 0 60 7/3 U
List manual 124 Parameter Manual, 02/2011,
6FC5397-7AP40-0BA0
-
Machine and setting data1.2 Display machine data
9105 HMI_WIDE_SCREEN - -- Display of the HMI as wide screen with
OEM area always
visible BYTE PowerOn
-- - 0 0 1 7/2 M
9106 SERVE_EXTCALL_PROGRAMS - -- Process EXTCALL calls BYTE
PowerOn-- - 1 0 1 7/3 M
9107 DRV_DIAG_DO_AND_COMP_NAMES - -- Expanded drive diagnostics:
DO and components BYTE Immediately-- - 0 0 3 7/3 I
9108 ENABLE_EPS_SERVICES - -- Activation of ePS Network services
BYTE Immediately-- - 0 0 1 7/3 M
9110 ACCESS_HMI_EXIT - -- Protection level of exit softkey BYTE
PowerOn-- - 1 0 7 7/2 M
9900 MD_TEXT_SWITCH - -- Plaintexts instead of MD identifier
BOOLEAN Immediately-- - 0 - - 7/3 U
9990 SW_OPTIONS - -- Enable HMI software options DWORD
Immediately-- - 0 - - 1/1 I
List manual 1Parameter Manual, 02/2011, 6FC5397-7AP40-0BA0
25
-
Machine and setting data 1.3 NC machine data
1.3 NC machine data
1.3.1 General machine data
Number Identifier Display filters ReferenceUnit Name Data type
ActiveAttributesSystem Dimension Default value Minimum value
Maximum value Protection Class
10000 AXCONF_MACHAX_NAME_TAB N01, N11 K2,F1,G2,F2,K5,M1- Machine
axis name STRING PowerOn-- 31 X1,Y1,Z1,A1,B1,C1,U
1...- - 7/2 M
10002 AXCONF_LOGIC_MACHAX_TAB N01 B3,K2- Logical NCK machine
axis image STRING PowerOn-- 31 AX1,AX2,AX3,AX4,AX
5,AX6...- - 3/2 M
10010 ASSIGN_CHAN_TO_MODE_GROUP N01, N02, N11 K1,K5- Channel
valid in mode group DWORD PowerOn-- 10 1,0,0,0,0,0,0,0,0,0,0,0,
0,0,0,00 10 7/2 M
10050 SYSCLOCK_CYCLE_TIME N01, N05, N11, -
G3,G2,R1
s System clock cycle DOUBLE PowerOnSFCO- - 0.002 0.001 0.008 7/2
M
10059 PROFIBUS_ALARM_MARKER N05 G3- PROFIBUS/PROFINET alarm flag
(internal only) BYTE PowerOnNBUP, NDLD- - 0 - - 0/0 S
10060 POSCTRL_SYSCLOCK_TIME_RATIO N01, N05 G3- Factor for
position control cycle DWORD PowerOnSFCO- - 1 1 31 7/2 M
10061 POSCTRL_CYCLE_TIME N01, N05 G3- Position control cycle
DOUBLE PowerOn-- - 0.0 - - 7/RO S
List manual 126 Parameter Manual, 02/2011,
6FC5397-7AP40-0BA0
-
Machine and setting data1.3 NC machine data
10062 POSCTRL_CYCLE_DELAY N01, N05 G3s Position control cycle
offset DOUBLE PowerOn-- - 0.0 0.000 0.008 7/2 M
10063 POSCTRL_CYCLE_DIAGNOSIS EXP, N01, N05 -s Active timing
DOUBLE PowerOn-- 6 0.0,0.0,0.0,0.0,0.0,0.0 - - 7/RO M
10064 POSCTRL_CYCLE_DESVAL_DELAY N01, N05 G3s Clock skew of the
DMA for the setpoints DOUBLE PowerOn-- - 0.0 0.000 0.008 7/2 M
10065 POSCTRL_DESVAL_DELAY N01 B3s Position setpoint delay
DOUBLE PowerOn-- - 0.0 -0.1 0.1 7/2 M
10070 IPO_SYSCLOCK_TIME_RATIO N01, N05, N11, -
G3,R1
- Factor for interpolation cycle DWORD PowerOnSFCO- - 4 1 100
7/2 M
10071 IPO_CYCLE_TIME N01, N05, N11, -
G3
- Interpolator cycle DOUBLE PowerOn-- - 0.0 - - 7/RO S
10072 COM_IPO_TIME_RATIO N01, N05 -- Division ratio between IPO
and communication task DOUBLE PowerOn-- - 1.0 0.0 100.0 7/2 M
10073 COM_IPO_STRATEGY EXP -- Strategy for activation of
communication. DWORD PowerOn-- - 0x0F 1 0x7F 0/0 S
10088 REBOOT_DELAY_TIME EXP K3s Reboot delay DOUBLE
Immediately-- - 0.2 0.0 1.0 2/2 M
List manual 1Parameter Manual, 02/2011, 6FC5397-7AP40-0BA0
27
-
Machine and setting data 1.3 NC machine data
10089 SAFE_PULSE_DIS_TIME_BUSFAIL N01, N06, - FBSIs Delay time
pulse suppr. for bus failure DOUBLE PowerOn-- - 0.0 0 0.8 7/2 M
10090 SAFETY_SYSCLOCK_TIME_RATIO N01, N06, - FBSI- Factor for
monitoring cycle DWORD PowerOnSFCO- - 3 1 50 7/1 M
10091 INFO_SAFETY_CYCLE_TIME N01, N06, N05, -
FBSI
s Display of monitoring cycle time DOUBLE PowerOn-- - 0.0 - -
7/RO S
10092 INFO_CROSSCHECK_CYCLE_TIME N01, N06, N05, -
FBSI
s Display of cycle time for cross-checking DOUBLE PowerOn-- -
0.0 - - 7/RO S
10093 INFO_NUM_SAFE_FILE_ACCESS EXP, N06, N05, -
FBSI
- Number of SPL file accesses DWORD PowerOn-- - 0 - - 0/RO S
10094 SAFE_ALARM_SUPPRESS_LEVEL EXP, N06, N05, -
FBSI
- Alarm suppress level BYTE PowerOn-- - 2 0 113 7/2 M
10095 SAFE_MODE_MASK EXP, N05, - FBSI- 'Safety Integrated'
operating modes DWORD PowerOn-- - 0 0x00000000 0x00000006 7/2 M
10096 SAFE_DIAGNOSIS_MASK EXP, N06, N05, -
FBSI
- 'Safety Integrated' diagnosis functions DWORD NEW CONF-- - 1 0
0x0007 7/2 M
10097 SAFE_SPL_STOP_MODE N01, N06, - FBSI- Stop reaction for SPL
errors BYTE PowerOn-- - 3 3 4 7/2 M
List manual 128 Parameter Manual, 02/2011,
6FC5397-7AP40-0BA0
-
Machine and setting data1.3 NC machine data
10098 PROFISAFE_IPO_TIME_RATIO N01, N06, - FBSI- Factor for
PROFIsafe communication DWORD PowerOnSFCO- - 1 1 25 7/1 M
10099 INFO_PROFISAFE_CYCLE_TIME N01, N06, N05, -
FBSI
s PROFIsafe communication cycle time DOUBLE PowerOn-- - 0.0 - -
7/RO S
10110 PLC_CYCLE_TIME_AVERAGE N01, N07 B1s Average PLC
acknowledgement time DOUBLE PowerOn-- - 0.05 - - 7/2 M
10130 TIME_LIMIT_NETTO_COM_TASK EXP, N01 OEMs Runtime limitation
of communication to HMI DOUBLE PowerOn-- - 0.05 0.01 1.000 0/0
S
10131 SUPPRESS_SCREEN_REFRESH EXP A2- Screen refresh response
under overload BYTE PowerOn-- - 0 0 2 7/2 M
10132 MMC_CMD_TIMEOUT EXP, N01, N06 PA,M4s Monitoring time for
HMI command in the part program DOUBLE PowerOn-- - 3.0 0.0 100.0
7/2 M
10134 MM_NUM_MMC_UNITS EXP, N01, N02 B3- Possible number of
simultaneous HMI communication partners DWORD PowerOn-- - 6 1 10
2/2 M
10136 DISPLAY_MODE_POSITION N01 -- Display mode for actual
position in the WCS DWORD Reset-- - 0 0 1 7/1 M
10156 TASK_SLEEP_TIME EXP -- Average time given per cycle DWORD
ImmediatelyNBUP- - 0 0 10000 7/2 M
List manual 1Parameter Manual, 02/2011, 6FC5397-7AP40-0BA0
29
-
Machine and setting data 1.3 NC machine data
10160 PREP_COM_TASK_CYCLE_RATIO EXP, N01 ECO- Factor for
communication with HMI DWORD PowerOn-- - 3 1 50 7/1 M
10161 COM_CONFIGURATION EXP, N01 -- Configuration of
communication DWORD PowerOn-- 8 5, 5,18, 1,16, 8,18,18 - - 0/0
S
10171 TIME_LIMIT_NETTO_PLCBG_TASK EXP, N01 ECOs Runtime
limitation of communication to SW PLC2xx DOUBLE PowerOn-- - 0.005
.001 0.100 0/0 S
10185 NCK_PCOS_TIME_RATIO EXP, N01 -- Processing time share NCK
DWORD PowerOn-- - 65 10 90 7/2 M
10190 TOOL_CHANGE_TIME N01 BA- Tool changing time for simulation
DOUBLE PowerOn-- - 0. - - 7/2 M
10192 GEAR_CHANGE_WAIT_TIME N01 S1s Gear stage change waiting
time DOUBLE PowerOn-- - 10.0 0.0 1.0e5 7/2 M
10200 INT_INCR_PER_MM N01 G2,K3- Calculation resolution for
linear positions DOUBLE PowerOnLINK- - 1000. 1.0 1.0e9 7/2 M
10210 INT_INCR_PER_DEG N01 G2,K3,R2- Calculation resolution for
angular positions DOUBLE PowerOnLINK- - 1000.0 1.0 1.0e9 7/2 M
10220 SCALING_USER_DEF_MASK EXP, N01 G2- Activation of scaling
factors DWORD PowerOnSCAL- - 0x200 0 0x3FFF 7/2 M
List manual 130 Parameter Manual, 02/2011,
6FC5397-7AP40-0BA0
-
Machine and setting data1.3 NC machine data
10230 SCALING_FACTORS_USER_DEF EXP, N01 G2- Scaling factors of
physical variables DOUBLE PowerOnSCAL- 15
1.0,1.0,1.0,1.0,1.0,1.0,
1.0,1.0,1.0...1e-9 - 7/2 M
10240 SCALING_SYSTEM_IS_METRIC N01 G2,K3,A3,S1- Basic system
metric BOOLEAN PowerOnSCAL- - TRUE - - 7/2 M
10250 SCALING_VALUE_INCH EXP G2- Conversion factor for INCH
DOUBLE PowerOnSCAL- - 25.4 1e-9 - 0/0 S
10260 CONVERT_SCALING_SYSTEM EXP -- Enable basic system
conversion BOOLEAN PowerOnLINK- - FALSE - - 1/1 M
10270 POS_TAB_SCALING_SYSTEM N01, N09 T1,N3,G2- System of units
of position tables BYTE Reset-- - 0 0 1 7/2 M
10280 PROG_FUNCTION_MASK EXP, N01 K1- Comparing (> and
-
Machine and setting data 1.3 NC machine data
10292 CC_TOA_PARAM_UNIT N09 G2- Physical units of cutting edge
data for compile cycles DWORD PowerOn-- 10 0,0,0,0,0,0,0,0,0,0 0 9
2/2 M
10293 CCS_TOA_PARAM_UNIT N09 -- Physical units of SIEMENS-OEM
cutting edge data DWORD PowerOn-- 10 0,0,0,0,0,0,0,0,0,0 0 9 2/2
M
10300 FASTIO_ANA_NUM_INPUTS N10 A4,TE1- Number of active analog
NCK inputs BYTE PowerOn-- - 0 0 8 7/2 M
10310 FASTIO_ANA_NUM_OUTPUTS N10 A4- Number of active analog NCK
outputs BYTE PowerOn-- - 0 0 8 7/2 M
10320 FASTIO_ANA_INPUT_WEIGHT N10 A4- Weighting factor for
analog NCK inputs DWORD PowerOn-- 8 10000,10000,10000,1
0000,10000,10000...1 10000000 7/2 M
10330 FASTIO_ANA_OUTPUT_WEIGHT N10 A4- Weighting factor for
analog NCK outputs DWORD PowerOn-- 8 10000,10000,10000,1
0000,10000,10000...1 10000000 7/2 M
10350 FASTIO_DIG_NUM_INPUTS N10 A4,TE1- Number of active digital
NCK input bytes BYTE PowerOn-- - 1 0 5 7/2 M
10360 FASTIO_DIG_NUM_OUTPUTS N10 A4,TE8- Number of active
digital NCK output bytes BYTE PowerOn-- - 0 0 5 7/2 M
10361 FASTIO_DIG_SHORT_CIRCUIT N10 A4- Short circuit of digital
inputs and outputs DWORD PowerOn-- 10 0,0,0,0,0,0,0,0,0,0 - - 7/2
M
List manual 132 Parameter Manual, 02/2011,
6FC5397-7AP40-0BA0
-
Machine and setting data1.3 NC machine data
10362 HW_ASSIGN_ANA_FASTIN N10 A4,TE1- Hardware assignment of
the fast analog NCK inputs DWORD PowerOn-- 8 0x01000000,0x01000
000,0x01000000...0x01000000 0x060003FF 7/2 M
10364 HW_ASSIGN_ANA_FASTOUT N10 A4,TE3- Hardware assignment of
external analog NCK outputs DWORD PowerOn-- 8
0x01000000,0x01000
000,0x01000000...0x01000000 0x060003FF 7/2 M
10366 HW_ASSIGN_DIG_FASTIN N10 A4,TE1- Hardware assignment of
external digital NCK inputs DWORD PowerOn-- 10
0x01000000,0x01000
000,0x01000000...0x01000000 0x060003FF 7/2 M
10368 HW_ASSIGN_DIG_FASTOUT N10 A4- Hardware assignment of
external digital NCK outputs DWORD PowerOn-- 4
0x01000000,0x01000
000,0x01000000...0x01000000 0x060003FF 7/2 M
10385 PROFISAFE_MASTER_ADDRESS N01, N06, - FBSI- PROFIsafe
address master module DWORD PowerOn-- MD_MAXNUM_SFP
S_MASTER_ADDR0,0,0 0 0x0500FA7D 7/2 M
10386 PROFISAFE_IN_ADDRESS N01, N06, - FBSI- PROFIsafe address
input module DWORD PowerOn-- 16 0,0,0,0,0,0,0,0,0,0,0,0,
0,0,0,00 0x0501FFFF 7/2 M
10387 PROFISAFE_OUT_ADDRESS N01, N06, - FBSI- PROFIsafe-address
output module DWORD PowerOn-- 16 0,0,0,0,0,0,0,0,0,0,0,0,
0,0,0,00 0x0501FFFF 7/2 M
10388 PROFISAFE_IN_ASSIGN N01, N06, - FBSI- Input.assignment
$A_INSE to PROFIsafe module DWORD PowerOn-- 16
0,0,0,0,0,0,0,0,0,0,0,0,
0,0,0,00 64064 7/2 M
List manual 1Parameter Manual, 02/2011, 6FC5397-7AP40-0BA0
33
-
Machine and setting data 1.3 NC machine data
10389 PROFISAFE_OUT_ASSIGN N01, N06, - FBSI- Outp.assignment
$A_OUTSE to PROFIsafe module DWORD PowerOn-- 16
0,0,0,0,0,0,0,0,0,0,0,0,
0,0,0,00 64064 7/2 M
10393 SAFE_DRIVE_LOGIC_ADDRESS N01, N06, - -- Logical drive
addresses SI DWORD PowerOn-- 31 6700,6724,6748,6772,
6796,6820,6844...258 8191 7/2 M
10394 PLCIO_NUM_BYTES_IN N10 A4- Number of directly readable
input bytes of the PLC I/Os BYTE PowerOn-- - 0 0 32 7/2 M
10395 PLCIO_LOGIC_ADDRESS_IN N10 A4- Start addr. of the directly
readable input bytes of the PLC I/Os DWORD PowerOn-- - 0 - - 7/2
M
10396 PLCIO_NUM_BYTES_OUT N10 A4- Number of directly writable
output bytes of the PLC I/Os BYTE PowerOn-- - 0 0 32 7/2 M
10397 PLCIO_LOGIC_ADDRESS_OUT N10 A4- Start addr. of the
directly writable output bytes of PLC I/O DWORD PowerOn-- - 0 - -
7/2 M
10398 PLCIO_IN_UPDATE_TIME N10 A4s Update time for PLCIO input
cycle DOUBLE PowerOn-- - 0.0 0 10000 7/2 M
10399 PLCIO_TYPE_REPRESENTATION N10 A4- Little/Big Endian for
PLCIO BYTE PowerOn-- - 0 0 1 7/2 M
10400 CC_VDI_IN_DATA EXP, N02 OEM- Number of input bytes for
compile cycles DWORD PowerOn-- - 0 0 1024 7/1 M
List manual 134 Parameter Manual, 02/2011,
6FC5397-7AP40-0BA0
-
Machine and setting data1.3 NC machine data
10410 CC_VDI_OUT_DATA EXP, N02 OEM- Number of output bytes for
compile cycles DWORD PowerOn-- - 0 0 1024 7/1 M
10420 CC_ASSIGN_FASTOUT_MASK EXP, N10 OEM- Reservation of
external outputs for compile cycles DWORD PowerOn-- - 0 - - 7/2
M
10430 CC_HW_DEBUG_MASK EXP OEM- Hardware debug mask for compile
cycles DWORD PowerOnNBUP, NDLD- - 0 0 0x7fffffff 7/1 M
10450 SW_CAM_ASSIGN_TAB N09 N3- Assignment of software cams to
machine axes BYTE PowerOn-- 32 0,0,0,0,0,0,0,0,0,0,0,0,
0,0,0,0,0,0,0,0,0,0,0,0,0,0...
0 31 7/2 M
10460 SW_CAM_MINUS_LEAD_TIME N09 N3s Lead or delay time at minus
cams 1-16 DOUBLE PowerOn-- 32 0.0,0.0,0.0,0.0,0.0,0.0,
0.0,0.0,0.0...- - 7/2 M
10461 SW_CAM_PLUS_LEAD_TIME N09 N3s Lead or delay time at plus
cams 1-16 DOUBLE PowerOn-- 32 0.0,0.0,0.0,0.0,0.0,0.0,
0.0,0.0,0.0...- - 7/2 M
10470 SW_CAM_ASSIGN_FASTOUT_1 N09 N3- Hardware assignment for
output of cams 1-8 to NCK I/Os DWORD PowerOn-- - 0 - - 7/2 M
10471 SW_CAM_ASSIGN_FASTOUT_2 N09 N3- Hardware assignment for
the output of cams 9-16 to NCK I/Os DWORD PowerOn-- - 0 - - 7/2
M
10472 SW_CAM_ASSIGN_FASTOUT_3 N09 N3- Hardware assignment for
output of cams 17-24 to NCK I/Os DWORD PowerOn-- - 0 - - 7/2 M
List manual 1Parameter Manual, 02/2011, 6FC5397-7AP40-0BA0
35
-
Machine and setting data 1.3 NC machine data
10473 SW_CAM_ASSIGN_FASTOUT_4 N09 N3- Hardware assignment for
output of cams 25-32 to NCK I/Os DWORD PowerOn-- - 0 - - 7/2 M
10480 SW_CAM_TIMER_FASTOUT_MASK N09 N3- Mask for output of cam
signals via timer interr. to NCU DWORD PowerOn-- - 0 - - 7/2 M
10485 SW_CAM_MODE N09 N3- Behavior of SW cams DWORD PowerOn-- -
0 - - 7/2 M
10490 SW_CAM_COMP_NCK_JITTER N09 -s Cam jitter compensation
DOUBLE NEW CONF-- - 0 0.0 0.0001 7/2 M
10500 DPIO_LOGIC_ADDRESS_IN N10 A4- Logical slot address of the
PROFIBUS/PROFINET I/Os DWORD PowerOn-- 16
0,0,0,0,0,0,0,0,0,0,0,0,
0,0,0,00 8191 7/2 M
10501 DPIO_RANGE_LENGTH_IN N10 A4- Length of the
PROFIBUS/PROFINET I/O range DWORD PowerOn-- 16
0,0,0,0,0,0,0,0,0,0,0,0,
0,0,0,00 128 7/2 M
10502 DPIO_RANGE_ATTRIBUTE_IN N10 A4- Attributes of the
PROFIBUS/PROFINET I/Os DWORD PowerOn-- 16 0x01,0x01,0x01,0x01,
0x01,0x01,0x01...0x00 0x0F 7/2 M
10510 DPIO_LOGIC_ADDRESS_OUT N10 A4- Logical slot address of the
PROFIBUS/PROFINET I/Os DWORD PowerOn-- 16
0,0,0,0,0,0,0,0,0,0,0,0,
0,0,0,00 8191 7/2 M
10511 DPIO_RANGE_LENGTH_OUT N10 A4- Length of the PROFIBUS I/O
range DWORD PowerOn-- 16 0,0,0,0,0,0,0,0,0,0,0,0,
0,0,0,00 128 7/2 M
List manual 136 Parameter Manual, 02/2011,
6FC5397-7AP40-0BA0
-
Machine and setting data1.3 NC machine data
10512 DPIO_RANGE_ATTRIBUTE_OUT N10 A4- Attributes of the
PROFIBUS/PROFINET I/Os DWORD PowerOn-- 16 0x01,0x01,0x01,0x01,
0x01,0x01,0x01...0x00 0x0F 7/2 M
10530 COMPAR_ASSIGN_ANA_INPUT_1 N10 A4- Hardware assignment of
analog inputs for comparator byte 1 BYTE PowerOn-- 8
0,0,0,0,0,0,0,0 - - 7/2 M
10531 COMPAR_ASSIGN_ANA_INPUT_2 N10 A4- Hardware assignment of
analog inputs for comparator byte 2 BYTE PowerOn-- 8
0,0,0,0,0,0,0,0 - - 7/2 M
10540 COMPAR_TYPE_1 N10 A4- Parameterization for comparator byte
1 DWORD PowerOn-- - 0 - - 7/2 M
10541 COMPAR_TYPE_2 N10 A4- Parameterization of comparator byte
2 DWORD PowerOn-- - 0 - - 7/2 M
10600 FRAME_ANGLE_INPUT_MODE EXP, N01, N09 K2- Sequence of
rotation in FRAME BYTE PowerOn-- - 1 1 2 7/2 M
10602 FRAME_GEOAX_CHANGE_MODE EXP, N01, N09 K2- Frames when
changing geometry axes BYTE PowerOn-- - 0 0 5 7/2 M
10604 WALIM_GEOAX_CHANGE_MODE EXP, N01, N09 A3- Working area
limitation by changing geometry axes BYTE PowerOn-- - 0 0 1 7/2
M
10610 MIRROR_REF_AX EXP, N01, N09 K2- Reference axis for
mirroring BYTE PowerOn-- - 0 0 3 7/2 M
List manual 1Parameter Manual, 02/2011, 6FC5397-7AP40-0BA0
37
-
Machine and setting data 1.3 NC machine data
10612 MIRROR_TOGGLE EXP, N01, N09 K2- Mirror toggle BYTE
PowerOn-- - 1 0 1 7/2 M
10613 NCBFRAME_RESET_MASK EXP K2- Active NCU global base frames
after reset DWORD Reset-- - 0xFFFF 0 0xFFFF 7/2 M
10615 NCBFRAME_POWERON_MASK EXP, N12 K2- Reset global base
frames after power on DWORD PowerOn-- - 0 0 0xFFFF 7/2 M
10616 MAPPED_FRAME_MASK N01 -- Enable frame mapping DWORD
PowerOn-- - 0x3001 0 0x00003FFF 7/2 M
10617 FRAME_SAVE_MASK EXP K2- Behavior of frames in SAVE
subroutines DWORD PowerOn-- - 0 0 0x3 7/2 M
10618 PROTAREA_GEOAX_CHANGE_MODE EXP, N01, N09 A3- Protection
range on change of geometry axes BYTE PowerOn-- - 0 0 3 7/2 M
10619 COLLISION_TOLERANCE EXP -mm Tolerance for collision check
DOUBLE NEW CONF-- - 1 0.001 1000.0 7/3 M
10620 EULER_ANGLE_NAME_TAB N01, N09 F2,TE4- Name of Euler angle
STRING PowerOn-- 3 A2,B2,C2 - - 7/2 M
10624 ORIPATH_LIFT_VECTOR_TAB N01, N09 -- Name of retraction
vector for path-relative orientation. STRING PowerOn-- 3 A8,B8,C8 -
- 7/2 M
10626 ORIPATH_LIFT_FACTOR_NAME N01, N09 -- Name of relative
safety clearance with ORIPATH STRING PowerOn-- - ORIPLF - - 7/2
M
List manual 138 Parameter Manual, 02/2011,
6FC5397-7AP40-0BA0
-
Machine and setting data1.3 NC machine data
10630 NORMAL_VECTOR_NAME_TAB N01, N09 F2- Name of normal vectors
STRING PowerOn-- 6 A4,B4,C4,A5,B5,C5 - - 7/2 M
10640 DIR_VECTOR_NAME_TAB N01, N09 F2,TE4- Name of direction
vectors STRING PowerOn-- 6 A3,B3,C3,AN3,BN3,C
N3- - 7/2 M
10642 ROT_VECTOR_NAME_TAB N01, N09 F2- Name of rotation vectors
STRING PowerOn-- 3 A6,B6,C6 - - 7/2 M
10644 INTER_VECTOR_NAME_TAB N01, N09 F2- Name of intermediate
vector components STRING PowerOn-- 3 A7,B7,C7 - - 7/2 M
10646 ORIENTATION_NAME_TAB N01, N09 F2- Identifiers for
programming a 2nd orientation path STRING PowerOn-- 3 XH,YH,ZH - -
7/2 M
10648 NUTATION_ANGLE_NAME N01, N09 F2- Name of aperture angle
STRING PowerOn-- - NUT - - 7/2 M
10650 IPO_PARAM_NAME_TAB EXP, N01 K2- Name of interpolation
parameters STRING PowerOn-- 3 I,J,K - - 7/2 M
10652 CONTOUR_DEF_ANGLE_NAME EXP, N01, N12 FBFA- Name of angle
for contour definitions STRING PowerOn-- - ANG - - 0/0 S
10654 RADIUS_NAME EXP, N01, N12 FBFA- Name of radius for contour
definitions STRING PowerOn-- - RND - - 0/0 S
List manual 1Parameter Manual, 02/2011, 6FC5397-7AP40-0BA0
39
-
Machine and setting data 1.3 NC machine data
10656 CHAMFER_NAME EXP, N01, N12 FBFA- Name of chamfer for
contour definitions STRING PowerOn-- - CHR - - 0/0 S
10660 INTERMEDIATE_POINT_NAME_TAB EXP, N01 K2- Name of
interpolation point coordinates for G2/G3 STRING PowerOn-- 3
I1,J1,K1 - - 7/2 M
10670 STAT_NAME N01, N09 F2- Name of state information STRING
PowerOn-- - STAT - - 7/2 M
10672 TU_NAME N01, N09 F2- Name of state information of axes
STRING PowerOn-- - TU - - 7/2 M
10674 PO_WITHOUT_POLY N01 F2- Polynomial programming
programmable without G function
POLY BOOLEAN PowerOn
-- - FALSE - - 7/2 M
10680 MIN_CONTOUR_SAMPLING_TIME N01, EXP -s Minimum contour
sampling time DOUBLE Reset-840dsl-71 - 0.004 - - 0/0 M840dsl-72 -
0.002 - - 0/0 M840dsl-73 - 0.0005 - - 0/0 M
10682 CONTOUR_SAMPLING_FACTOR N01, EXP -- Contour sampling
factor DOUBLE Reset-- - 1.0 - - 1/1 M
10690 DRAW_POS_TRIGGER_TIME EXP, N01 -s Trigger time for IPO
event 'DRAW_POS' DOUBLE NEW CONF-- - 0.3 0 30 1/1 M
10700 PREPROCESSING_LEVEL N01, N02 V2,K1- Program preprocessing
level BYTE PowerOn-- - 0x25 - - 2/2 M
List manual 140 Parameter Manual, 02/2011,
6FC5397-7AP40-0BA0
-
Machine and setting data1.3 NC machine data
10702 IGNORE_SINGLEBLOCK_MASK N01 K1,Z1- Prevents stopping at
specific blocks in single block mode DWORD PowerOn-- - 0 0 0x1FFFF
7/2 M
10704 DRYRUN_MASK N01 V1- Dry run feedrate activation BYTE
PowerOn-- - 0 0 2 7/2 M
10706 SLASH_MASK N01 PG,A2- Activation of block skip BYTE
PowerOn-- - 0 0 2 7/2 M
10707 PROG_TEST_MASK N01 K1- Program test mode DWORD PowerOn-- -
0x1 0 0x7 7/2 M
10708 SERUPRO_MASK N01 K1- Search run modes DWORD PowerOn-- - 0
0 31 7/2 M
10709 PROG_SD_POWERON_INIT_TAB EXP, N01 K1- Setting data to be
initialized DWORD PowerOn-- 30 43200,43202,0,0,0,0,0
,0,0,0,0,0,0,0,0,0,0,0...- - 7/2 M
10710 PROG_SD_RESET_SAVE_TAB EXP, N01 A3, V1- Setting data to be
updated DWORD PowerOn-- 30 0,0,0,0,0,0,0,0,0,0,0,0,
0,0,0,0,0,0,0,0,0,0,0,0,0,0...
- - 7/2 M
10711 NC_LANGUAGE_CONFIGURATION EXP, N01 K1- NC language
commands of inactive options / functions DWORD PowerOn-- - 0 0 4
0/0 S
10712 NC_USER_CODE_CONF_NAME_TAB EXP, N01, N12 TE1,B1- List of
reconfigured NC codes STRING PowerOn-- 200 ... - - 2/2 M
List manual 1Parameter Manual, 02/2011, 6FC5397-7AP40-0BA0
41
-
Machine and setting data 1.3 NC machine data
10713 M_NO_FCT_STOPRE EXP, N12, N07 H2- M function with
preprocessing stop DWORD PowerOn-- 15 -1,-1,-1,-1,-1,-1,-1,-1,-
1,-1,-1,-1,-1...- - 7/2 M
10714 M_NO_FCT_EOP EXP, N07 K1,H2- M function for spindle active
after reset DWORD PowerOn-- - -1 - - 7/2 M
10715 M_NO_FCT_CYCLE EXP, N12, N07 H2,K1- M function to be
replaced by a subroutine DWORD PowerOn-- 30
-1,-1,-1,-1,-1,-1,-1,-1,-
1,-1,-1,-1,-1...- - 7/2 M
10716 M_NO_FCT_CYCLE_NAME EXP, N12, N07 K1- Subroutine name for
M function replacement STRING PowerOn-- 30 - - 7/2 M
10717 T_NO_FCT_CYCLE_NAME EXP, N12, N07 K1- Name of
tool-changing cycle for T function replacement STRING PowerOn-- - -
- 7/2 M
10718 M_NO_FCT_CYCLE_PAR EXP, N12, N07 K1- M function
replacement with parameters DWORD PowerOn-- - -1 - - 7/2 M
10719 T_NO_FCT_CYCLE_MODE EXP, N12, N07 K1- Setting of T
function substitution DWORD PowerOn-- - 0 0 7 7/2 M
10720 OPERATING_MODE_DEFAULT N01 H2- Setting of mode after power
ON BYTE PowerOn-- 10 7,7,7,7,7,7,7,7,7,7 0 12 7/2 M
10722 AXCHANGE_MASK EXP, N01 K5- Parameterization for axis
replacement behavior DWORD PowerOn-- - 0 0 0xFFFF 7/2 M
List manual 142 Parameter Manual, 02/2011,
6FC5397-7AP40-0BA0
-
Machine and setting data1.3 NC machine data
10731 JOG_MODE_KEYS_EDGETRIGGRD EXP, N01 IAF- Functioning of the
JOG keys BOOLEAN PowerOn-- - TRUE - - 0/0 S
10735 JOG_MODE_MASK EXP, N01 K1- Settings for JOG mode DWORD
PowerOn-- - 0 0 0xff 7/2 M
10750 SPRINT_FORMAT_P_CODE N12 PGA- String coding of the SPRINT
format %P DWORD PowerOn-- - 0 0 2 7/2 M
10751 SPRINT_FORMAT_P_DECIMAL N12 PGA- Parameterization of the
SPRINT format %P DWORD PowerOn-- - 0 0 1 7/2 M
10760 G53_TOOLCORR N12 FBFA- Method of operation of G53, G153
and SUPA DWORD NEW CONF-- - 0 0 3 7/2 M
10780 UNLOCK_EDIT_MODESWITCH EXP, N01 -- Cancel start disable
when editing a part program BOOLEAN PowerOn-- - FALSE - - 0/0 S
10800 EXTERN_CHAN_SYNC_M_NO_MIN EXP, N12 H2- 1st M function for
channel synchronization DWORD PowerOn-- - -1 - - 7/2 M
10802 EXTERN_CHAN_SYNC_M_NO_MAX EXP, N12 H2- Last M function for
channel synchronization DWORD PowerOn-- - -1 - - 7/2 M
10804 EXTERN_M_NO_SET_INT EXP, N12 H2,K1- M function to activate
ASUB DWORD PowerOn-- - 96 - - 7/2 M
10806 EXTERN_M_NO_DISABLE_INT EXP, N12 H2,K1- M function to
deactivate ASUB DWORD PowerOn-- - 97 - - 7/2 M
List manual 1Parameter Manual, 02/2011, 6FC5397-7AP40-0BA0
43
-
Machine and setting data 1.3 NC machine data
10808 EXTERN_INTERRUPT_BITS_M96 EXP, N12 FBFA- Activate
interrupt program (ASUB) DWORD PowerOn-- - 0 - - 7/2 M
10810 EXTERN_MEAS_G31_P_SIGNAL EXP, N12 FBFA- Config. of
measuring inputs for G31 P.. BYTE PowerOn-- 4 1,1,1,1 0 3 7/2 M
10812 EXTERN_DOUBLE_TURRET_ON EXP, N12 FBFA- Double turret with
G68 BOOLEAN PowerOn-- - FALSE - - 7/2 M
10814 EXTERN_M_NO_MAC_CYCLE EXP, N12 H2,K1- Macro call via M
function DWORD PowerOn-- 30 -1,-1,-1,-1,-1,-1,-1,-1,-
1,-1,-1,-1,-1...- - 7/2 M
10815 EXTERN_M_NO_MAC_CYCLE_NAME EXP, N12 H2- Name of subroutine
for M function macro call STRING PowerOn-- 30 - - 7/2 M
10816 EXTERN_G_NO_MAC_CYCLE EXP, N12 FBFA- Macro call via G
function DOUBLE PowerOn-- 50 -1.,-1.,-1.,-1.,-1.,-1.,-
1.,-1.,-1....- - 7/2 M
10817 EXTERN_G_NO_MAC_CYCLE_NAME EXP, N12 FBFA- Name of
subroutine for G function macro call STRING PowerOn-- 50 - - 7/2
M
10818 EXTERN_INTERRUPT_NUM_ASUP EXP, N12 FBFA- Interrupt number
for ASUB start (M96) BYTE PowerOn-- - 1 1 8 7/2 M
10820 EXTERN_INTERRUPT_NUM_RETRAC EXP, N12 FBFA- Interrupt
number for rapid retraction (G10.6) BYTE PowerOn-- - 2 1 8 7/2
M
List manual 144 Parameter Manual, 02/2011,
6FC5397-7AP40-0BA0
-
Machine and setting data1.3 NC machine data
10830 EXTERN_PRINT_DEVICE EXP, N12 FBFA- Output device for
ISOPRINT STRING PowerOn-- - - - 7/2 M
10831 EXTERN_PRINT_MODE EXP, N12 FBFA- Parameterize output
device for ISOPRINT DWORD PowerOn-- - 0 0 63 7/2 M
10850 MM_EXTERN_MAXNUM_OEM_GCODES EXP, N01, N12 -- Maximum
number of OEM G codes DWORD PowerOn-- - 0 0 1000 1/1 M
10880 MM_EXTERN_CNC_SYSTEM N01, N12 FBFA- Definition of the
control system to be adapted DWORD PowerOn-- - 1 1 3 7/2 M
10881 MM_EXTERN_GCODE_SYSTEM N01, N12 FBFA- ISO_3 Mode:
GCodeSystem DWORD PowerOn-- - 0 0 2 7/2 M
10882 NC_USER_EXTERN_GCODES_TAB N12 FBFA- List of user-specific
G commands of an external NC language STRING PowerOn-- 60 - - 2/2
M
10884 EXTERN_FLOATINGPOINT_PROG N12 FBFA- Evaluation of
programmed values without decimal point BOOLEAN PowerOn-- - TRUE -
- 7/2 M
10886 EXTERN_INCREMENT_SYSTEM N12 FBFA- Incremental system in
external language mode BOOLEAN PowerOn-- - FALSE - - 7/2 M
10888 EXTERN_DIGITS_TOOL_NO N12 FBFA- Digits for T number in ISO
mode BYTE PowerOn-- - 2 0 8 7/2 M
10889 EXTERN_DIGITS_OFFSET_NO N12 FBFA- Digits for offset number
in ISO mode BYTE PowerOn-- - 0 0 8 7/2 M
List manual 1Parameter Manual, 02/2011, 6FC5397-7AP40-0BA0
45
-
Machine and setting data 1.3 NC machine data
10890 EXTERN_TOOLPROG_MODE N12 FBFA- Tool change programming for
external language DWORD PowerOn-- - 0x0 - - 7/2 M
10900 INDEX_AX_LENGTH_POS_TAB_1 N09 T1- Number of positions for
indexing axis table 1 DWORD Reset-- - 0 0 60 7/2 M
10910 INDEX_AX_POS_TAB_1 N09 T1mm/inch, degrees
Indexing position table 1 DOUBLE Reset
-- 60 0.,0.,0.,0.,0.,0.,0.,0.,0.,
0.,0.,0.,0....- - 7/2 M
10920 INDEX_AX_LENGTH_POS_TAB_2 N09 T1- Number of positions for
indexing axis table 2 DWORD Reset-- - 0 0 60 7/2 M
10930 INDEX_AX_POS_TAB_2 N09 T1mm/inch, degrees
Indexing position table 2 DOUBLE Reset
-- 60 0.,0.,0.,0.,0.,0.,0.,0.,0.,
0.,0.,0.,0....- - 7/2 M
10940 INDEX_AX_MODE EXP T1- Settings for indexing position DWORD
PowerOn-- - 0 0 1 7/2 M
11100 AUXFU_MAXNUM_GROUP_ASSIGN N01, N07, N02 H2- Number of
auxiliary functions distr. amongst aux. fct. groups DWORD PowerOn--
- 1 1 255 7/2 M
11110 AUXFU_GROUP_SPEC N07 H2- Auxiliary function group
specification DWORD PowerOn-- 168 0x81,0x21,0x41,0x41,
0x41,0x41,0x41...- - 7/2 M
11120 LUD_EXTENDED_SCOPE N01 PG- Function "program global user
data (PUD)" is active BOOLEAN PowerOn-- - FALSE - - 7/2 M
List manual 146 Parameter Manual, 02/2011,
6FC5397-7AP40-0BA0
-
Machine and setting data1.3 NC machine data
11140 GUD_AREA_SAVE_TAB N01 -- Additional saving for GUD modules
DWORD Immediately-- 9 0,0,0,0,0,0,0,0,0 - - 7/2 M
11160 ACCESS_EXEC_CST N01 -- Execution right for /_N_CST_DIR
BYTE PowerOn-- - 7 - - 7/2 M
11161 ACCESS_EXEC_CMA N01 -- Execution right for /_N_CMA_DIR
BYTE PowerOn-- - 7 - - 7/2 M
11162 ACCESS_EXEC_CUS N01 -- Execution right for /_N_CUS_DIR
BYTE PowerOn-- - 7 - - 7/3 U
11165 ACCESS_WRITE_CST N01 -- Write protection for directory
/_N_CST_DIR DWORD PowerOn-- - -1 - - 7/2 M
11166 ACCESS_WRITE_CMA N01 -- Write protection for directory
/_N_CMA_DIR DWORD PowerOn-- - -1 - - 7/2 M
11167 ACCESS_WRITE_CUS N01 -- Write protection for directory
/_N_CUS_DIR DWORD PowerOn-- - -1 - - 7/3 U
11170 ACCESS_WRITE_SACCESS N01 -- Write protection for
_N_SACCESS_DEF BYTE PowerOn-- - 7 - - 7/2 M
11171 ACCESS_WRITE_MACCESS N01 -- Write protection for
_N_MACCESS_DEF BYTE PowerOn-- - 7 - - 7/2 M
11172 ACCESS_WRITE_UACCESS N01 -- Write protection for
_N_UACCESS_DEF BYTE PowerOn-- - 7 - - 7/3 U
List manual 1Parameter Manual, 02/2011, 6FC5397-7AP40-0BA0
47
-
Machine and setting data 1.3 NC machine data
11200 INIT_MD EXP, N01 IAF,IAD,IA- Standard machine data loaded
at next Power On BYTE PowerOn-- - 0 - - 7/2 M
11210 UPLOAD_MD_CHANGES_ONLY N01, N05 IAD- Machine data backup
of changed machine data only BYTE Immediately-- - 0xFF - - 7/3
M
11220 INI_FILE_MODE N01, N05 G2- Error response to INI file
errors BYTE Reset-- - 1 0 2 7/2 M
11230 MD_FILE_STYLE N01, N05 IAD- Structure of machine data
backup files BYTE ImmediatelyLINK- - 0x3 - - 7/3 M
11250 PROFIBUS_SHUTDOWN_TYPE EXP, N01 G3,FBU- PROFIBUS/PROFINET
shutdown handling BYTE PowerOn-- - 0 0 2 7/2 M
11280 WPD_INI_MODE N01 IAD- Handling of INI files in workpiece
directory BYTE PowerOn-- - 0 0 1 7/2 M
11285 MACH_MODEL_MODE EXP IAD- Type of file with machine model
BYTE Immediately-- - 0 0 1 3/3 U
11290 DRAM_FILESYSTEM_MASK N01 S7- Select directories in DRAM
DWORD PowerOn-- - 0x3f - - 0/RO S
11292 DRAM_FILESYST_CONFIG EXP -- Configuration of the DRAM file
system BYTE PowerOn-- - 0x22 - - 0/RO S
11294 SIEM_TRACEFILES_CONFIG EXP -- Configuration of the SIEM*
trace file DWORD PowerOn-- - 0 - - 2/2 M
List manual 148 Parameter Manual, 02/2011,
6FC5397-7AP40-0BA0
-
Machine and setting data1.3 NC machine data
11295 PROTOC_FILE_MEM N01 -- Memory type for log files BYTE
PowerOn-- 10 1,1,1,1,1,1,1,1,1,1 0 1 1/1 M
11297 PROTOC_IPOCYCLE_CONTROL N01 -- Prevent overrun of IPO time
level BYTE PowerOn-- 10 1,1,1,1,1,1,1,1,1,1 0 1 1/1 M
11298 PROTOC_PREPTIME_CONTROL N01 -- Interruption time prep time
level in seconds. DOUBLE PowerOn-- 10 1.0,1.0,1.0,1.0,1.0,1.0,
1.0,1.0,1.0...- - 1/1 M
11300 JOG_INC_MODE_LEVELTRIGGRD N01 H1,R1- INC and REF in jog
mode BOOLEAN PowerOn-- - TRUE - - 7/2 M
11310 HANDWH_REVERSE N09 H1- Threshold for direction change
handwheel BYTE PowerOn-- - 2 - - 7/2 M
11320 HANDWH_IMP_PER_LATCH N09 H1- Handwheel pulses per detent
position DOUBLE PowerOn-- 6 1.,1.,1.,1.,1.,1. - - 7/2 M
11322 CONTOURHANDWH_IMP_PER_LATCH N09 H1- Contour handwheel
pulses per detent position DOUBLE PowerOn-- 6 1.,1.,1.,1.,1.,1. - -
7/2 M
11324 HANDWH_VDI_REPRESENTATION N01 OEM- Display of handwheel
number in VDI Interface DWORD PowerOn-- - 0 0 1 7/2 M
11330 JOG_INCR_SIZE_TAB EXP, N09 H1- Increment size for
INC/handwheel DOUBLE PowerOn-- 5 1.,10.,100.,1000.,1000
0.- - 7/2 M
List manual 1Parameter Manual, 02/2011, 6FC5397-7AP40-0BA0
49
-
Machine and setting data 1.3 NC machine data
11346 HANDWH_TRUE_DISTANCE N01 H1,P1,W1- Handwheel default path
or velocity BYTE PowerOn-- - 1 0 7 7/2 M
11350 HANDWHEEL_SEGMENT N09 H1- Handwheel segment BYTE PowerOn--
6 0,0,0,0,0,0 - - 7/2 M
11351 HANDWHEEL_MODULE N09 H1- Handwheel module BYTE PowerOn-- 6
0,0,0,0,0,0 0 6 7/2 M
11352 HANDWHEEL_INPUT N09 H1- Handwheel connection BYTE
PowerOn-- 6 0,0,0,0,0,0 0 6 7/2 M
11353 HANDWHEEL_LOGIC_ADDRESS N04, N10 H1- Logical handwheel
slot addresses DWORD PowerOn-- 6 0,0,0,0,0,0 0 8191 7/2 M
11354 HANDWHEEL_FILTER_TIME N09 -s Filter time for handwheel
pulses DOUBLE PowerOn-- 6 0.0,0.0,0.0,0.0,0.0,0.0 0.0 2.0 7/2 M
11380 MONITOR_ADDRESS EXP, N06 STZ- Test MD for changing the NCK
code or data for Safety
Integrated DWORD Immediately
NBUP, NDLD- - 0 - - 0/0 S
11382 MONITOR_DISPLAY_INT EXP, N06 STZ- INTEGER display of the
addressed location DWORD ImmediatelyNBUP, NDLD- - 0 - - 0/0 S
11384 MONITOR_DISPLAY_REAL EXP, N06 STZ- REAL display of the
addressed location DOUBLE ImmediatelyNBUP, NDLD- - 0.0 - - 0/0
S
List manual 150 Parameter Manual, 02/2011,
6FC5397-7AP40-0BA0
-
Machine and setting data1.3 NC machine data
11386 MONITOR_INPUT_INT EXP, N06 STZ- INTEGER input for the
addressed location DWORD ImmediatelyNBUP, NDLD- - 0 - - 0/0 S
11388 MONITOR_INPUT_REAL EXP, N06 STZ- REAL input for addressed
location DOUBLE ImmediatelyNBUP, NDLD- - 0.0 - - 0/0 S
11390 MONITOR_INPUT_STROBE EXP, N06 STZ- Overwrite the addressed
location with MONITOR_INT/REAL BYTE ImmediatelyNBUP, NDLD- - 0 0 2
0/0 S
11398 AXIS_VAR_SERVER_SENSITIVE EXP B3- Axis-Var server response
BYTE PowerOn-- - 0 - - 7/2 M
11400 TRACE_SELECT EXP -- Activation of internal trace functions
DWORD PowerOn-- - 0 - - 0/0 S
11405 TCI_TRACE_ACTIVE EXP -- Activation of internal task trace
function BOOLEAN PowerOn-- - FALSE - - 0/0 S
11410 SUPPRESS_ALARM_MASK EXP, N06 D1,M3,K3,S1,V1,W1- Mask for
support of special alarm outputs DWORD PowerOn-- - 0x108000 0
0xFFFFFFFF 7/2 M
11411 ENABLE_ALARM_MASK EXP D1,K1- Activation of warnings DWORD
Reset-- - 0x0 0 0xFFFFFFFF 7/2 M
11412 ALARM_REACTION_CHAN_NOREADY EXP, N01 D1- Alarm response
CHAN_NOREADY permitted BOOLEAN PowerOn-- - FALSE - - 7/2 M
11413 ALARM_PAR_DISPLAY_TEXT EXP, N01 D1- Alarm parameter as
text output BOOLEAN PowerOn-- - FALSE - - 0/0 S
List manual 1Parameter Manual, 02/2011, 6FC5397-7AP40-0BA0
51
-
Machine and setting data 1.3 NC machine data
11414 ALARM_CLR_NCSTART_W_CANCEL EXP, N01 D1- Clear NCSTART
alarms with CANCEL BOOLEAN PowerOn-- - FALSE - - 7/2 M
11415 SUPPRESS_ALARM_MASK_2 EXP, N06 -- Masking of alarm outputs
DWORD PowerOn-- - 0x8 - - 7/2 M
11420 LEN_PROTOCOL_FILE N01 PGA- Size of protocol files (kB)
DWORD PowerOn-- - 1 1 1000000 7/2 M
11422 PROTOCOL_FILE_MODE EXP, N01 PGA- Setting the behavior of
the WRITE command DWORD PowerOn-- - 0 0 0x3 7/2 M
11450 SEARCH_RUN_MODE EXP, N01 K1,TE3,N4,H2,Z1- Parameterization
for search run DWORD PowerOn-- - 0 0 0x3F 7/2 M
11460 OSCILL_MODE_MASK N09 P5- Mode mask for asynchronous
oscillation DWORD PowerOn-- - 0x0 0 0xFFFF 7/2 M
11470 REPOS_MODE_MASK EXP, N01 K1- Repositioning properties
DWORD PowerOn-- - 0x8 0 0xFFFF 7/2 M
11480 PLC_OB1_TRACE_DEPTH EXP, N03, N09 -- Buffer depth of PLC
trace data at OB1 DWORD PowerOn-- - 2 2 8 2/2 M
11481 PLC_OB35_TRACE_DEPTH EXP, N03, N09 -- Buffer depth of PLC
trace data at OB35 DWORD PowerOn-- - 2 2 8 2/2 M
11482 PLC_OB40_TRACE_DEPTH EXP, N03, N09 -- Buffer depth of PLC
trace data at OB40 DWORD PowerOn-- - 2 2 8 2/2 M
List manual 152 Parameter Manual, 02/2011,
6FC5397-7AP40-0BA0
-
Machine and setting data1.3 NC machine data
11500 PREVENT_SYNACT_LOCK N01, N09, - S5,FBSY- Protected
synchronized actions DWORD PowerOn-- 2 0,0 0 255 7/2 M
11510 IPO_MAX_LOAD N01, N05 -% Max. permitted IPO load DOUBLE
PowerOn-- - 0.00 0.0 100.0 7/2 M
11550 STOP_MODE_MASK N01 V1- Defines the stop behavior. DWORD
PowerOn-- - 0 0 0x1 7/2 M
11600 BAG_MASK N01 K1,Z1- Defines the mode group behavior DWORD
PowerOn-- - 0 0 0x3 7/2 M
11602 ASUP_START_MASK N01, - K1,M3,TE3,TE7- Ignore stop
conditions for ASUB DWORD PowerOn-- - 0 0 0xf 7/2 M
11604 ASUP_START_PRIO_LEVEL N01, - K1,TE3,TE7- Priorities from
which 'ASUP_START_MASK' is effective DWORD PowerOn-- - 0 0 128 7/2
M
11610 ASUP_EDITABLE N01 K1- Activation of a user-specific ASUB
program DWORD PowerOn-- - 0 0 0x7 7/2 M
11612 ASUP_EDIT_PROTECTION_LEVEL N01 K1- Protection level of the
user-specific ASUB program DWORD PowerOn-- - 2 0 7 7/2 M
11620 PROG_EVENT_NAME EXP, N12 K1- Program name for PROG_EVENT
STRING PowerOn-- - - - 7/2 M
11622 PROG_EVENT_PATH N01 -- Call path for PROG_EVENT BYTE
PowerOn-- - 3 0 3 7/2 M
List manual 1Parameter Manual, 02/2011, 6FC5397-7AP40-0BA0
53
-
Machine and setting data 1.3 NC machine data
11640 ENABLE_CHAN_AX_GAP N01, N11 K2- Allow channel axis gaps in
AXCONF_MACHAX_USED DWORD PowerOn-- - 0x0 0 0x1 2/2 M
11660 NUM_EG N09 M3- Number of possible 'electronic gear units'
BYTE PowerOn-- - 0 - - 1/1 M
11717 D_NO_FCT_CYCLE_NAME EXP, N12, N07 K1- Subroutine name for
D function replacement STRING PowerOn-- - - - 7/2 M
11750 NCK_LEAD_FUNCTION_MASK N09 -- Functions for master value
coupling DWORD NEW CONF-- - 0x00 0 0x10 1/1 M
11752 NCK_TRAIL_FUNCTION_MASK N09 -- Functions for coupled
motion DWORD NEW CONF-- - 0x200 0 0x210 1/1 M
11754 COUPLE_CYCLE_MASK EXP, N09 -- Replacement of coupling
language commands by machining
cycles DWORD PowerOn
-- - 0x7F 0 0x7F 1/1 M
11756 NCK_EG_FUNCTION_MASK N09 -- Functions for Electronic Gear
DWORD NEW CONF-- - 0x0 0 0x2F 1/1 M
12000 OVR_AX_IS_GRAY_CODE EXP, N10 V1,Z1- Axis feedrate override
switch Gray-coded BOOLEAN PowerOn-- - TRUE - - 7/2 M
12010 OVR_FACTOR_AX_SPEED EXP, N10 V1,Z1- Evaluation of axis
feedrate override switch DOUBLE PowerOn-- 31
0.00,0.01,0.02,0.04,0.
06,0.08,0.10...0.00 2.00 7/2 M
List manual 154 Parameter Manual, 02/2011,
6FC5397-7AP40-0BA0
-
Machine and setting data1.3 NC machine data
12020 OVR_FEED_IS_GRAY_CODE EXP, N10 V1,Z1- Path feedrate
override switch Gray-coded BOOLEAN PowerOn-- - TRUE - - 7/2 M
12030 OVR_FACTOR_FEEDRATE EXP, N10 V1,B1,Z1- Evaluation of path
feedrate override switch DOUBLE PowerOn-- 31
0.00,0.01,0.02,0.04,0.
06,0.08,0.10...0.00 2.00 7/2 M
12040 OVR_RAPID_IS_GRAY_CODE EXP, N10 V1,Z1- Rapid traverse
override switch Gray-coded BOOLEAN PowerOn-- - TRUE - - 7/2 M
12050 OVR_FACTOR_RAPID_TRA EXP, N10 V1,Z1- Evaluation of rapid
traverse override switch DOUBLE PowerOn-- 31
0.00,0.01,0.02,0.04,0.
06,0.08,0.10...0.00 1.00 7/2 M
12060 OVR_SPIND_IS_GRAY_CODE EXP, N10 V1,Z1- Spindle override
switch Gray-coded BOOLEAN PowerOn-- - TRUE - - 7/2 M
12070 OVR_FACTOR_SPIND_SPEED EXP, N10 V1,Z1- Evaluation of
spindle override switch DOUBLE PowerOn-- 31
0.5,0.55,0.60,0.65,0.7
0,0.75,0.80...0.00 2.00 7/2 M
12080 OVR_REFERENCE_IS_PROG_FEED N10, N09 V1- Override reference
speed BOOLEAN PowerOn-- - TRUE - - 7/2 M
12082 OVR_REFERENCE_IS_MIN_FEED N10, N09 V1- Specification of
the reference of the path override BOOLEAN PowerOn-- - FALSE - -
7/2 M
12090 OVR_FUNCTION_MASK N01, N10, N09 -- Selection of override
specifications DWORD Reset-- - 0 0 0x01 7/2 M
List manual 1Parameter Manual, 02/2011, 6FC5397-7AP40-0BA0
55
-
Machine and setting data 1.3 NC machine data
12100 OVR_FACTOR_LIMIT_BIN EXP, N10 V1,B1,Z1- Limitation for
binary-coded override switch DOUBLE PowerOn-- - 1.2 0.0 2.0 7/2
M
12200 RUN_OVERRIDE_0 N01, N09 FBMA,V1,Z1- Traversing response
with override 0 BOOLEAN PowerOn-- - FALSE - - 7/2 M
12202 PERMANENT_FEED N01, N09 Z1,V1mm/min Fixed feedrates for
linear axes DOUBLE Reset-- 4 0.,0.,0.,0. - - 7/2 M
12204 PERMANENT_ROT_AX_FEED N01, N09 V1rev/min Fixed feedrates
for rotary axes DOUBLE Reset-- 4 0.,0.,0.,0. - - 7/2 M
12205 PERMANENT_SPINDLE_FEED N01, N09 FBMArev/min Fixed
feedrates for spindles DOUBLE Reset-- 4 0.,0.,0.,0. - - 7/2 M
12300 CENTRAL_LUBRICATION N01, N09 -- Central lubrication active
BOOLEAN PowerOn-- - FALSE - - 7/2 M
12510 NCU_LINKNO N01 B3- NCU number in an NCU cluster DWORD
PowerOn-- - 1 1 16 7/2 M
12520 LINK_TERMINATION N01 B3- NCU numbers for which bus
termination resistances are
activated BYTE PowerOn
LINK- 2 0,1 0 15 3/2 M
12540 LINK_BAUDRATE_SWITCH N01 B3- Link bus baud rate DWORD
PowerOnLINK- - 9 0 9 3/2 M
List manual 156 Parameter Manual, 02/2011,
6FC5397-7AP40-0BA0
-
Machine and setting data1.3 NC machine data
12550 LINK_RETRY_CTR N01 B3- maximum number of message frame
transmission retries DWORD PowerOnLINK- - 4 1 15 3/2 M
12551 TIMEOUT_LINK_COMMUNICATION EXP -s Wait time at start of
link communication DOUBLE PowerOn-- 6 84.0,60.0,
9.0,60.0,0.0,0.00.0 1000.0 0/0 S
12552 LINK_LIFECYCLE_MAX_LOOP EXP -- Maximum number of loops for
synchronization of the link life
cycle. DWORD PowerOn
-- - 5000 - - 0/0 S
12701 AXCT_AXCONF_ASSIGN_TAB1 N01 B3- Assignment of an axis
container location STRING PowerOnCTDE- 32 - - 3/2 M
12702 AXCT_AXCONF_ASSIGN_TAB2 N01 B3- Assignment of an axis
container location STRING PowerOnCTDE- 32 - - 3/2 M
12703 AXCT_AXCONF_ASSIGN_TAB3 N01 B3- Assignment of an axis
container location STRING PowerOnCTDE- 32 - - 3/2 M
12704 AXCT_AXCONF_ASSIGN_TAB4 N01 B3- Assignment of an axis
container location STRING PowerOnCTDE- 32 - - 3/2 M
12705 AXCT_AXCONF_ASSIGN_TAB5 N01 B3- Assignment of an axis
container location STRING PowerOnCTDE- 32 - - 3/2 M
12706 AXCT_AXCONF_ASSIGN_TAB6 N01 B3- Assignment of an axis
container location STRING PowerOnCTDE- 32 - - 3/2 M
List manual 1Parameter Manual, 02/2011, 6FC5397-7AP40-0BA0
57
-
Machine and setting data 1.3 NC machine data
12707 AXCT_AXCONF_ASSIGN_TAB7 N01 B3- Assignment of an axis
container location STRING PowerOnCTDE- 32 - - 3/2 M
12708 AXCT_AXCONF_ASSIGN_TAB8 N01 B3- Assignment of an axis
container location STRING PowerOnCTDE- 32 - - 3/2 M
12709 AXCT_AXCONF_ASSIGN_TAB9 N01 B3- Assignment of an axis
container location STRING PowerOnCTDE- 32 - - 3/2 M
12710 AXCT_AXCONF_ASSIGN_TAB10 N01 B3- Assignment of an axis
container location STRING PowerOnCTDE- 32 - - 3/2 M
12711 AXCT_AXCONF_ASSIGN_TAB11 N01 B3- Assignment of an axis
container location STRING PowerOnCTDE- 32 - - 3/2 M
12712 AXCT_AXCONF_ASSIGN_TAB12 N01 B3- Assignment of an axis
container location STRING PowerOnCTDE- 32 - - 3/2 M
12713 AXCT_AXCONF_ASSIGN_TAB13 N01 B3- Assignment of an axis
container location STRING PowerOnCTDE- 32 - - 3/2 M
12714 AXCT_AXCONF_ASSIGN_TAB14 N01 B3- Assignment of an axis
container location STRING PowerOnCTDE- 32 - - 3/2 M
12715 AXCT_AXCONF_ASSIGN_TAB15 N01 B3- Assignment of an axis
container location STRING PowerOnCTDE- 32 - - 3/2 M
12716 AXCT_AXCONF_ASSIGN_TAB16 N01 B3- Assignment of an axis
container location STRING PowerOnCTDE- 32 - - 3/2 M
List manual 158 Parameter Manual, 02/2011,
6FC5397-7AP40-0BA0
-
Machine and setting data1.3 NC machine data
12750 AXCT_NAME_TAB N01 B3- Axis container identifier STRING
PowerOnCTDE- 16 CT1,CT2,CT3,CT4,CT
5,CT6...- - 1/1 M
12760 AXCT_FUNCTION_MASK N09 -- Functions for the axis container
DWORD NEW CONF-- - 0x0 0 0x1 1/1 M
12970 PLC_DIG_IN_LOGIC_ADDRESS N10 -- Logical start address of
the digital PLC input address DWORD PowerOn-- - 0 0 1023 0/0 S
12971 PLC_DIG_IN_NUM N10 -- Number of digital input addresses
DWORD PowerOn-- - 64 1 1023 0/0 S
12974 PLC_DIG_OUT_LOGIC_ADDRESS N10 -- Logical start address of
the digital PLC output addresses DWORD PowerOn-- - 0 0 1023 0/0
S
12975 PLC_DIG_OUT_NUM N10 -- Number of digital output addresses
DWORD PowerOn-- - 48 1 1023 0/0 S
12978 PLC_ANA_IN_LOGIC_ADDRESS N10 -- Logical start address of
the analog PLC input addresses DWORD PowerOn-- - 0 0 1023 0/0 S
12979 PLC_ANA_IN_NUM N10 -- Number of analog input addresses
DWORD PowerOn-- - 0 0 1023 0/0 S
12982 PLC_ANA_OUT_LOGIC_ADDRESS N10 -- Logical start address of
the analog PLC output addresses DWORD PowerOn-- - 0 0 1023 0/0
S
List manual 1Parameter Manual, 02/2011, 6FC5397-7AP40-0BA0
59
-
Machine and setting data 1.3 NC machine data
12983 PLC_ANA_OUT_NUM N10 -- Number of analog output addresses
DWORD PowerOn-- - 0 0 1023 0/0 S
13050 DRIVE_LOGIC_ADDRESS N04, N10 G2- Logical drive addresses
DWORD PowerOn-- 31 4100,4140,4180,4220,
4260,4300,4340...258 8191 7/2 M
13060 DRIVE_TELEGRAM_TYPE N04, N10 G2- Standard message frame
type for PROFIdrive DWORD PowerOn-- 31 116,116,116,116,116,
116,116,116,116...- - 7/2 M
13070 DRIVE_FUNCTION_MASK N04, N10 G2- PROFIdrive expansion
functions DWORD PowerOn-- 31 2,2,2,2,2,2,2,2,2,2,2,2,
2,2,2,2,2,2,2,2,2,2,2,2,2,2...
- - 7/2 M
13080 DRIVE_TYPE_DP EXP G2- PROFIBUS/PROFINET drive type BYTE
PowerOn-- 31 0,0,0,0,0,0,0,0,0,0,0,0,
0,0,0,0,0,0,0,0,0,0,0,0,0,0...
0 4 7/2 M
13110 PROFIBUS_TRACE_ADDRESS EXP -- PROFIBUS/PROFINET trace of
I/O slots DWORD NEW CONF-- 14 0,0,0,0,0,0,0,0,0,0,0,0,
0,0- - 2/2 M
13111 PROFIBUS_TRACE_TYPE EXP -- PROFIBUS/PROFINET trace
settings DWORD NEW CONF-- - 0 0 3 2/2 M
13112 PROFIBUS_TRACE_FILE_SIZE EXP -- Maximum trace file size in
kbytes DWORD NEW CONF-- - 40 - - 2/2 M
List manual 160 Parameter Manual, 02/2011,
6FC5397-7AP40-0BA0
-
Machine and setting data1.3 NC machine data
13113 PROFIBUS_TRACE_START EXP -- Activation of
PROFIBUS/PROFINET trace DWORD Immediately-- - 0 0 1 2/2 M
13114 PROFIBUS_TRACE_START_EVENT EXP -- Trigger conditions for
PROFIBUS/PROFINET trace DWORD NEW CONF-- 14
0,0,0,0,0,0,0,0,0,0,0,0,
0,00x00000000 0x111fffff 2/2 M
13120 CONTROL_UNIT_LOGIC_ADDRESS N04, N10 -- Logical address of
SINAMICS CU DWORD PowerOn-- 15 6500,0,0,0,0,0,0,0,0,0,
0,0,0,0,00 8191 7/2 M
13140 PROFIBUS_ALARM_ACCESS N04, N10 -- Alarm response of
PROFIBUS/PROFINET drives on power up DWORD Immediately-- - 1 0 2
2/7 M
13150 SINAMICS_ALARM_MASK N04, N05 -- Activate fault and warning
buffer output for Sinamics DWORD Immediately-- - 0x0909 - - 7/2
M
13200 MEAS_PROBE_LOW_ACTIVE N10, N09 M5- Polarity reversal of
sensor BOOLEAN PowerOn-- 2 FALSE,FALSE - - 7/2 M
13210 MEAS_TYPE N10, N09 M5- Meas. type with decentralized
drives BYTE PowerOn-- - 0 0 1 7/2 M
13211 MEAS_CENTRAL_SOURCE N10, N09 -- Data source central
measurement with PROFIBUS/PROFINET
drives BYTE PowerOn
-- - 3 1 3 7/2 M
13220 MEAS_PROBE_DELAY_TIME N10, N09 FBA/IADs Delay time between
probe deflection and recognition DOUBLE PowerOn-- 2 0.0,0.0 0 0.1
7/2 M
List manual 1Parameter Manual, 02/2011, 6FC5397-7AP40-0BA0
61
-
Machine and setting data 1.3 NC machine data
13230 MEAS_PROBE_SOURCE N10, N09 -- Probe simulation BYTE
PowerOn-- - 0 0 9 7/2 M
13231 MEAS_PROBE_OFFSET N10, N09 -mm/inch, degrees
Probe offset DOUBLE Immediately
-- - 0.1 - - 7/7 U
13300 PROFISAFE_IN_FILTER N01, N06, - -- Useful F data filter IN
DWORD PowerOn-- 16 0xFFFFFFFF,0xFFFF
FFFF,0xFFFFFFFF...- - 7/2 M
13301 PROFISAFE_OUT_FILTER N01, N06, - -- Useful F data filter
OUT DWORD PowerOn-- 16 0xFFFFFFFF,0xFFFF
FFFF,0xFFFFFFFF...- - 7/2 M
13302 PROFISAFE_IN_ENABLE_MASK N01, N06, - -- Enable mask for
connections to PROFIsafe input modules. DWORD PowerOn-- - 0x0 0x0
0xFFFF 7/2 M
13303 PROFISAFE_OUT_ENABLE_MASK N01, N06, - -- Enable mask for
connections to PROFIsafe output modules. DWORD PowerOn-- - 0x0 0x0
0xFFFF 7/2 M
13304 PROFISAFE_IN_SUBS_ENAB_MASK N01, N06, - -- Activation of
substitute value output for PROFIsafe input
modules DWORD PowerOn
-- - 0x0 0x0 0xFFFF 7/2 M
13305 PROFISAFE_IN_SUBS N01, N06, - -- Substitute values for
passive connections to PROFIsafe input
modules DWORD PowerOn
-- 16 0x0,0x0,0x0,0x0,0x0,0
x0,0x0,0x0,0x0...0x0 0xFFFFFFFF 7/2 M
13308 PROFISAFE_IN_NAME N01, N06, - -- Name of the PROFIsafe IN
connection STRING PowerOn-- 16 - - 7/2 M
List manual 162 Parameter Manual, 02/2011,
6FC5397-7AP40-0BA0
-
Machine and setting data1.3 NC machine data
13309 PROFISAFE_OUT_NAME N01, N06, - -- Name of the PROFIsafe
OUT connection STRING PowerOn-- 16 - - 7/2 M
13310 SAFE_SPL_START_TIMEOUT N01, N05, - FBSIs Delay in display
of alarm 27097 DOUBLE PowerOn-- - 20. 1. 60. 7/2 M
13312 SAFE_SPL_USER_DATA N01, N06, - FBSI- User data DWORD
PowerOnSFCO- 4 0x0,0x0,0x0,0x0 - - 7/2 M
13316 SAFE_GLOB_CFG_CHANGE_DATE EXP, N01, N06, -
FBSI
- Date/time of last change of SI-NCK MD STRING PowerOn-- 7 - -
7/RO S
13317 SAFE_GLOB_PREV_CONFIG EXP, N01, N06, -
FBSI
- Data of previous safety configuration DWORD PowerOn-- 11
0,0,0,0,0,0,0,0,0,0,0 - - 0/RO S
13318 SAFE_GLOB_ACT_CHECKSUM EXP, N01, N06, -
FBSI
- Actual checksum NCK DWORD PowerOn-- 4 0,0,0,0 - - 7/RO S
13319 SAFE_GLOB_DES_CHECKSUM EXP, N01, N06, -
FBSI
- Desired (expected) checksum DWORD PowerOn-- 4 0,0,0,0 - - 7/1
M
13320 SAFE_SRDP_IPO_TIME_RATIO N01, N06, - FBSI- Factor F_DP
communication cycle DWORD PowerOnSFCO- - 10 1 65535 7/2 M
13322 INFO_SAFE_SRDP_CYCLE_TIME N01, N06, N05, -
FBSI
s Maximum F_DP communication cycle DOUBLE PowerOn-- - 0.0 - -
7/RO S
List manual 1Parameter Manual, 02/2011, 6FC5397-7AP40-0BA0
63
-
Machine and setting data 1.3 NC machine data
13330 SAFE_SDP_ENABLE_MASK N01, N06, - FBSI- Enable screen
F_SENDDP communication relationships DWORD PowerOn-- - 0x0 0x0
0xFFF 7/2 M
13331 SAFE_SDP_ID N01, N06, - FBSI- ID for F_SENDDP
communication relationship DWORD PowerOn-- 12
0,0,0,0,0,0,0,0,0,0,0,0 -32768 32767 7/2 M
13332 SAFE_SDP_NAME N01, N06, - FBSI- Name of SPL connection
STRING PowerOn-- 12 - - 7/2 M
13333 SAFE_SDP_CONNECTION_NR N01, N06, - FBSI- Number of SPL
connection BYTE PowerOn-- 12 0,0,0,0,0,0,0,0,0,0,0,0 0 3 7/2 M
13334 SAFE_SDP_LADDR N01, N06, - FBSI- Basic address of the
input/output data range F_SENDDP DWORD PowerOn-- 12
288,288,288,288,288,
288,288,288,288...288 32767 7/2 M
13335 SAFE_SDP_TIMEOUT N01, N06, - FBSIs Monitoring time
F_SENDDP DOUBLE PowerOn-- 12 0.5,0.5,0.5,0.5,0.5,0.5,
0.5,0.5,0.5...0.0 60.0 7/2 M
13336 SAFE_SDP_ASSIGN N01, N06, - FBSI- Output
assignment.$A_OUTSE to F_SENDDP user data DWORD PowerOn-- 12
0,0,0,0,0,0,0,0,0,0,0,0 0 64064 7/2 M
13337 SAFE_SDP_FILTER N01, N06, - FBSI- F user data filter
between $A_OUTSE and F_SENDDP DWORD PowerOn-- 12
0xFFFF,0xFFFF,0xFF
FF,0xFFFF,0xFFFF...0x0 0xFFFF 7/2 M
13338 SAFE_SDP_ERR_REAC N01, N06, - FBSI- Fault reaction DWORD
PowerOn-- 12 0,0,0,0,0,0,0,0,0,0,0,0 0 3 7/2 M
List manual 164 Parameter Manual, 02/2011,
6FC5397-7AP40-0BA0
-
Machine and setting data1.3 NC machine data
13340 SAFE_RDP_ENABLE_MASK N01, N06, - FBSI- Enable screen
F_RECVDP communication relationships DWORD PowerOn-- - 0x0 0x0
0xFFF 7/2 M
13341 SAFE_RDP_ID N01, N06, - FBSI- ID for F_RECVDP
communication relationships DWORD PowerOn-- 12
0,0,0,0,0,0,0,0,0,0,0,0 -32768 32767 7/2 M
13342 SAFE_RDP_NAME N01, N06, - FBSI- Name of SPL connection
STRING PowerOn-- 12 - - 7/2 M
13343 SAFE_RDP_CONNECTION_NR N01, N06, - FBSI- Assignment SPL
connection to system variables BYTE PowerOn-- 12
0,0,0,0,0,0,0,0,0,0,0,0 0 3 7/2 M
13344 SAFE_RDP_LADDR N01, N06, - FBSI- Basic address of the
input/output data range F_RECVDP DWORD PowerOn-- 12
288,288,288,288,288,
288,288,288,288...288 32767 7/2 M
13345 SAFE_RDP_TIMEOUT N01, N06, - FBSIs Monitoring time
F_RECVDP DOUBLE PowerOn-- 12 0.5,0.5,0.5,0.5,0.5,0.5,
0.5,0.5,0.5...0.0 60.0 7/2 M
13346 SAFE_RDP_ASSIGN N01, N06, - FBSI- Input assignment.
F_RECVDP user data to $A_INSE DWORD PowerOn-- 12
0,0,0,0,0,0,0,0,0,0,0,0 0 64064 7/2 M
13347 SAFE_RDP_FILTER N01, N06, - FBSI- F user data filter
between F_RECVDP and $A_INSE DWORD PowerOn-- 12
0xFFFF,0xFFFF,0xFF
FF,0xFFFF,0xFFFF...0x0 0xFFFF 7/2 M
13348 SAFE_RDP_ERR_REAC N01, N06, - FBSI- Fault reaction DWORD
PowerOn-- 12 0,0,0,0,0,0,0,0,0,0,0,0 0 3 7/2 M
List manual 1Parameter Manual, 02/2011, 6FC5397-7AP40-0BA0
65
-
Machine and setting data 1.3 NC machine data
13349 SAFE_RDP_SUBS N01, N06, - FBSI- Replacement values in case
of error DWORD PowerOn-- 12 0,0,0,0,0,0,0,0,0,0,0,0 0 0xFFFF 7/2
M
14504 MAXNUM_USER_DATA_INT N03 P3- Number of user data (INT)
DWORD PowerOn-- - 0 0 256 7/2 M
14506 MAXNUM_USER_DATA_HEX N03 P3- Number of user data (HEX)
DWORD PowerOn-- - 0 0 256 7/2 M
14508 MAXNUM_USER_DATA_FLOAT N03 P3- Number of user data (FLOAT)
DWORD PowerOn-- - 0 0 32 7/2 M
14510 USER_DATA_INT N03 P3- User data (INT) DWORD PowerOn-- 256
0,0,0,0,0,0,0,0,0,0,0,0,
0,0,0,0,0,0,0,0,0,0,0,0,0,0...
-32768 32767 7/2 I
14512 USER_DATA_HEX N03 P3- User data (HEX) DWORD PowerOn-- 256
0,0,0,0,0,0,0,0,0,0,0,0,
0,0,0,0,0,0,0,0,0,0,0,0,0,0...
0 0x0FF 7/2 I
14514 USER_DATA_FLO