Top Banner
69
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Papers on the Induction Motor Transients.
Page 2: Papers on the Induction Motor Transients.
Page 3: Papers on the Induction Motor Transients.
Page 4: Papers on the Induction Motor Transients.
Page 5: Papers on the Induction Motor Transients.
Page 6: Papers on the Induction Motor Transients.
Page 7: Papers on the Induction Motor Transients.
Page 8: Papers on the Induction Motor Transients.
Page 9: Papers on the Induction Motor Transients.
Page 10: Papers on the Induction Motor Transients.
Page 11: Papers on the Induction Motor Transients.
Page 12: Papers on the Induction Motor Transients.
Page 13: Papers on the Induction Motor Transients.
Page 14: Papers on the Induction Motor Transients.
Page 15: Papers on the Induction Motor Transients.
Page 16: Papers on the Induction Motor Transients.

Papers on thePapers on the

Induction Motor TransientsInduction Motor Transients

Page 17: Papers on the Induction Motor Transients.

Common Types of Transient Phenomena in Electric Power Systems

Lighting strokes on or near transmission lines

Energization of transmission lines (closing and reclosing operations)

Capacitor switching.

Interruption of small inductive currents (switching off reactors and unloaded transformers)

Series capacitor switching and subsynchronous resonance

Load rejection

Transient recovery voltage across circuit breakers

etc.

Page 18: Papers on the Induction Motor Transients.

Analysis of induction motor starting transients

Page 19: Papers on the Induction Motor Transients.

Torque and Rotor Speed

0

0.2

0.4

0.6

0.8

1

0 0.3 0.6 0.9 1.2 1.5Time [sec.]

Rotor speed [pu]

-0.5

0.4

1.3

2.2

3.1

4

0 0.3 0.6 0.9 1.2 1.5

Time [sec.]

Electromagnetic torque [pu]

Page 20: Papers on the Induction Motor Transients.

Per Unit a, b, and c Phase Currents

-6

-4

-2

0

2

4

6

0 0.3 0.6 0.9 1.2 1.5

Time [sec.]

Phase "a" current

-6

-4

-2

0

2

4

6

0 0.3 0.6 0.9 1.2 1.5Time [sec]

Phase "b" current

-6

-4

-2

0

2

4

6

0 0.3 0.6 0.9 1.2 1.5Time [sec.]

Phase "c" current

Page 21: Papers on the Induction Motor Transients.

0

1

2

3

4

5

6

0 0.3 0.6 0.9 1.2 1.5

Time [sec.]

d-axis stator current [pu]

d- and q-Axis Components of Stator Current

-6

-5

-4

-3

-2

-1

0

0 0.3 0.6 0.9 1.2 1.5Time [sec.]

q-axis stator current [pu]

Page 22: Papers on the Induction Motor Transients.

d- and q-Axis Components of Rotor Current

-6

-5

-4

-3

-2

-1

0

0 0.3 0.6 0.9 1.2 1.5Time [sec.]

d-axis rotor current [pu]

0

0.9

1.8

2.7

3.6

4.5

0 0.3 0.6 0.9 1.2 1.5

Time [sec.]

q-axis rotor current [pu]

Page 23: Papers on the Induction Motor Transients.

-0.3

-0.2

-0.1

0

0.1

0.2

0.3

0.4

0.5

0.6

0 0.3 0.6 0.9 1.2 1.5

Time [sec.]

d-axis stator flux [pu]

-1

-0.8

-0.6

-0.4

-0.2

0

0 0.3 0.6 0.9 1.2 1.5Time [sec.]

q-axis stator flux

d- and q-Axis Components of Stator Flux

Page 24: Papers on the Induction Motor Transients.

d- and q-Axis Components of Rotor Flux

-0.6

-0.5

-0.4

-0.3

-0.2

-0.1

0

0.1

0.2

0 0.3 0.6 0.9 1.2 1.5

Time [sec.]

d-axis rotor flux [pu]

-0.8

-0.7

-0.6

-0.5

-0.4

-0.3

-0.2

-0.1

0

0.1

0.2

0 0.3 0.6 0.9 1.2 1.5

Time [sec.]

q-axis rotor flux [pu]

Page 25: Papers on the Induction Motor Transients.

Conclusions

Line start produces higher currents, flux linkages, and dc offsets in them.

The torque pulsations are very severe, and repeated line starting could endanger the mechanical integrity of the motor.

Higher stator and rotor currents also produce resistive losses that are multiple times the design limit.

Page 26: Papers on the Induction Motor Transients.

A Fast Recursive Solution for Induction Motor Transients

IEEE Trans. on Ind. Applications, 1988

S. Ertem and Y. Baghzouz

Page 27: Papers on the Induction Motor Transients.

Detail Induction Machine Model

Page 28: Papers on the Induction Motor Transients.

Detail Induction Machine Model

Page 29: Papers on the Induction Motor Transients.

Simulation Algorithm and Test Results

Page 30: Papers on the Induction Motor Transients.
Page 31: Papers on the Induction Motor Transients.
Page 32: Papers on the Induction Motor Transients.
Page 33: Papers on the Induction Motor Transients.

Synchronous Machine Models for Simulation of Induction Motor Transients

IEEE Trans. on Power Systems, 1996R. Hung, Student Member IEEE

H.W. Dommel, Fellow IEEE

The University of British Columbia Department of Electrical Engineering Vancouver, B.C., V6T 1Z4, Canada.

Page 34: Papers on the Induction Motor Transients.

Similarity between synchronous machine and induction motor models

Page 35: Papers on the Induction Motor Transients.

Comparison…..

Since there is practically no saliency in an induction motor, the equivalent circuit shown in Fig. 2 is valid for both d- and q- axes.

Comparing Figs. 1 and 2, it can be seen that the synchronous machine model is almost identical with that of the induction motor model. In fact, if the field winding of the synchronous machine model is short-circuited, the synchronous machine model will become the induction motor model.

The flux and current relationships for both machine types are of the same form. For the synchronous machine, the relationship is

Page 36: Papers on the Induction Motor Transients.

Flux and current relationships

For the synchronous machine,

Page 37: Papers on the Induction Motor Transients.

Simulation results

The minor modifications in the synchronous machine model to make it behave as an induction motor model have been implemented in the EMTP version MicroTran® of the University of British Columbia.

To show its usefulness, the start-up of a large induction motor is simulated.

The data required for this simulation are provided in the Appendix; and the results of this simulation are given next.

Page 38: Papers on the Induction Motor Transients.

Specifications of the Induction Motor

Page 39: Papers on the Induction Motor Transients.

Simulation Results

Page 40: Papers on the Induction Motor Transients.

Conclusions

The current envelope in Figure 5(a) shows the large inrush currents which exist during a motor start-up. The amplitudes of these currents remain practically unchanged until the motor has reached its rated speed.

In addition, d.c. offset currents are present in the beginning of the start-up process.

The torque curve, on the other hand, shows that there is a large oscillatory torque immediately after the motor is energized.

Comparing Figures 5(a) and 5(b), it is seen that this oscillatory torque decays with the d.c. offset currents.

Finally, the speed curve shows that the rotor speed climbs up steadily to its rated value. In particular, a small overshoot is observed before the rotor speed settles down to its rated value.

Page 41: Papers on the Induction Motor Transients.

Starting High Inertia Loads

Robbie McElveen Reliance Electric Rockwell Automation

101 Reliance Road Kings Mountain, NC 28086

Mike ToneyAmoco Corporation 3700 Bay Area Blvd.

Houston, TX 77058

Page 42: Papers on the Induction Motor Transients.

Objectives

Many methods are used to reduce the current draw during startup of high inertia applications such as centrifuges, hammer mills, or large fans.

Reduced current conditions are desired to decrease the strain on both the motor and the connected mechanical system.

This reduction in starting current leads to a corresponding reduction in the starting torque available from the motor.

This reduction in torque leads to longer acceleration times and the potential for increased heating during startup.

The goal of this paper is to evaluate the "conventional" methods of starting, and to compare each of the methods for temperature rise, acceleration time, and economical considerations.

Page 43: Papers on the Induction Motor Transients.

Methods of starting AC induction motors

Full Voltage (across-the-line) starting Electro-mechanical reduced voltage starting

auto-transformer starting wye-delta (star-delta) starting, and resistor/reactor starting

Solid-state reduced voltage starting, and Variable frequency drive starting

Page 44: Papers on the Induction Motor Transients.

Full Voltage (across-the-line) starting

Of the many methods, full voltage (or across-the-line) starting is typically used

This method of starting results in a large initial current surge, known as inrush, which is typically 600% to 700% RMS of the full load current drawn by the motor.

Power companies may apply restrictions as to how much current draw is allowed.

These restrictions are typically specified as the maximum allowable voltage drop at the incoming power connection point or the maximum allowable kVA which may be drawn by the plant.

By limiting the inrush, the corresponding voltage drop will be reduced. Brownout or other associated problems may be experienced if the

voltage dips too much. Furthermore, this inrush current induces large magnetic forces in the

stator windings which actually try to force the windings to move and distort.

Page 45: Papers on the Induction Motor Transients.

Full Voltage starting (cont’d)

Full voltage starting produces greatest amount of starting torque High starting torque is desired when starting a high inertia load in

order to limit the acceleration time Beyond the initial shock of inrush current and torque, this type of

starting result in a smooth acceleration characteristic with the shortest acceleration time

Page 46: Papers on the Induction Motor Transients.

Electro-Mechanical Reduced Voltage Starting

This is a popular method which is used to reduced inrush current With this type of starting, the current drawn by the motor decreases

linearly with decreasing voltage Torque is reduced by the square of the percent voltage ratio

ratedrated

reducedreduced

ratedrated

reducedreduced

VV

VT

IV

VI

2.2

1.1

Page 47: Papers on the Induction Motor Transients.

Electro-Mechanical Reduced Voltage Starting can be achieved in three ways:

Auto-transformer: as the motor gains speed, taps are changed to increase the voltage at the motor terminals. Autotransformer starting is a more costly method than either wye-delta or resistor/reactor starting.

Wye-Delta: this method is used for motor voltages of less than 1000 volts. a normally delta-connected stator is connected in wye during the initial startup phase. It is most common for the motor to reach full speed before the transition to the delta connection is made. This essentially applies full voltage to the motor at this point. The advantage of connecting the stator in wye is that only 0.57 times rated voltage is applied to the phase windings. This results in only 0.57 of nominal current draw, but reduces the starting torque by factor of three as well. A drawback of this method is that it requires the neutrals of the motor.

Page 48: Papers on the Induction Motor Transients.

Relative magnitudes of Torque and current for both wye and delta configurations

Page 49: Papers on the Induction Motor Transients.

Electro-Mechanical Reduced Voltage Starting can be achieved in three ways:

Auto-transformer Wye-Delta Primary resistor/reactor: This kind of starting is achieved by

placing a resistance or inductance in series with the motor leads in order to reduce the inrush current. When the motor is nearly up to speed, the resistor or reactor may be switched out of the circuit, causing transitory currents with their corresponding torque pulsations. Energy is wasted as heat is dissipated in the resistor during each startup cycle. Less energy is wasted when using a reactor, but the magnitude can still be significant.

Page 50: Papers on the Induction Motor Transients.

Solid-state reduced voltage starting (Electronic Soft Starting)

Voltage ramp starting: Voltage ramp starting is the simplest form of soft starting in which a microprocessor is used to control the firing angle of pairs of SCRs, thus progressively increasing the voltage supplied to the motor.

Current limiting starting: In this case the user can set a pre-defined maximum current that will be supplied to the motor. The starter control circuit will sense the load current or motor back EMF and alter the firing angle of the SCRs in order to adjust the voltage at every point to whatever value is necessary in order to maintain the current at the desired level.

Data from the feedback circuit is used to adjust the voltage in order to maintain the current at a constant level

Page 51: Papers on the Induction Motor Transients.

Below are graphs showing acceleration times and motor heating results for various current limits. Figure 8 demonstrates how the acceleration time increases with decreasing the current limit to the motor. As less current is supplied to the motor, less starting torque is produced, which results in increased acceleration time.

Page 52: Papers on the Induction Motor Transients.

Figure 9 illustrates how both the rotor and stator temperature rises are affected by decreasing the current limit. Because there is less available torque under limited current conditions, the tendency is to believe that increased motor heating may result. However, due to the fact that the current is reduced, both the rotor and stator I2r losses are decreased. In addition to this decrease in losses, the acceleration time is extended, allowing for more of the heat generated to be dissipated to the frame and surrounding atmosphere. Thus, the reduced current leads not to increased heating, but rather to a cooler acceleration for the motor.

Page 53: Papers on the Induction Motor Transients.

Variable frequency drive starting Starting a motor using a variable frequency drive provides maximum control

over the starting characteristic.

Because the frequency is varied, the motor operates only on the right side of breakdown on the speed-torque curve.

Thus, any torque value from full load to breakdown can be achieved across the entire speed range from zero speed to base speed assuming that the drive has the necessary current capability. The load can be accelerated as slowly as desired, thus virtually eliminating mechanical stress.

The VFD is considerably more expensive than the other methods discussed and takes up more space than the other electronic starter option (soft start)

Page 54: Papers on the Induction Motor Transients.

TIME DOMAIN ANALYSIS OF INDUCTION MOTOR STARTING TRANSIENTS

R. Natarajan, V. K. Misra, and Mathew. Oommen Mine Electrical Laboratory

Department of Mineral Engineering The Pennsylvania State University

University Park, PA 16802

Page 55: Papers on the Induction Motor Transients.

Objectives

In this paper, a simplified time domain analysis based on equivalent circuit, differential equations, and Laplace transform is presented for the calculation of the starting current of an induction motor.

Experimental verification of the results were carried out on a 2-hp, 220 V, 7 A, 3,600 r/min, Y-connected, three-phase induction motor.

Page 56: Papers on the Induction Motor Transients.

Introduction Induction motors draw approximately 500% to 700% of rated

current during starting. This causes significant voltage drop at the terminals, and affects the performance of other equipment connected in parallel.

In industrial, and commercial distribution systems, the voltage dip due to motor starting causes flicker of incandescent lamps. The maximum voltage dip, and the frequency of dips, are dictated by standards. For example, a 6% voltage dip is allowed for one fluctuation per hour [1].

In order to reduce the intensity of the voltage drop in small and medium size motors, wye-delta starters are employed. Still many motors are started directly on-line.

In applications like conveyor starting, solid-state starters are employed to limit the magnitude of the starting current, while developing adequate torque [2].

Page 57: Papers on the Induction Motor Transients.

PROPOSED MATHEMATICAL MODEL

The sudden application of a sinusoidal forcing function to the conventional per phase equivalent circuit is used in the transient analysis. A closed form time domain solution is derived for the switching transients using the following steps.

Differential equations from the equivalent circuit,

Laplace transform of the above equations,

Solutions by partial fractions, and

Inverse Laplace transform, and time domain solution.

Page 58: Papers on the Induction Motor Transients.

Assumptions

The MMF waveform is assumed to be sinusoidal,

Saturation is partly neglected,

The effect of eddy currents are neglected,

The dynamics of the rotor is not accounted, and

The initial stored energy is assumed to be zero.

Page 59: Papers on the Induction Motor Transients.
Page 60: Papers on the Induction Motor Transients.

Taking Laplace of the voltage equations and solving for I1

Page 61: Papers on the Induction Motor Transients.

Simulation: Determination of the inrush current

Page 62: Papers on the Induction Motor Transients.

Current components during starting

Page 63: Papers on the Induction Motor Transients.

Observation….

The magnitude of the natural response component is -35 A, and this component decays rapidly with a very small time constant.

The maximum value of the real current component is 30 A. The reactive current component is appreciable during starting

(38 A), and can be supplied locally with the help of capacitors

Page 64: Papers on the Induction Motor Transients.

Experimental Verification

The starting of the motor was performed by switching on a circuit breaker

To record the transient starting current, a clamp-on current transducer was installed on one phase.

A 10 ohm resistor was used as the transducer load, and the transient output was obtained in the form of voltage.

The transient signal was stored on a Tektronix 5111A storage oscilloscope, and was photographed using a polaroid camera.

The transient stator current is 49 A under noload condition (Fig.5) and the starting time is 2.8 sec. With load, starting time is 3 sec.

Page 65: Papers on the Induction Motor Transients.

Adjustable ac Capacitor for a

Single-Phase Induction Motor

Eduard Muljadi, Member, IEEEYifan Zhao, Tian-Hua Liu, Member, IEEE

Thomas A. Lipo, Fellow, IEEE

Page 66: Papers on the Induction Motor Transients.

Abstract

The most common practice for starting a single-phase induction machine (SPIM) is to install a starting capacitor in series with the auxiliary winding.

In some applications, two capacitors are used. One is used during the starting period to help create the starting torque. The other one is used during the running condition to improve efficiency.

This paper discusses the possibility of using an electronic switch in parallel with the running capacitor, thereby providing the equivalent of a starting capacitor. The capacitor is shorted during each cycle to vary the effective size of the ac capacitor.

By using this method, only one capacitor is used for both the starting and running condition, and a similar starting performance can be obtained when compared with the conventional method using two capacitors.

Page 67: Papers on the Induction Motor Transients.

Introduction The capacitor size must be determined according to the terminal

impedance of the auxiliary winding. Unfortunately, this impedance changes dramatically from the starting to

the running condition. Hence, it is not practical to use only one fixed value capacitor for both starting and running.

If both the largest starting torque and best running conditions are needed, at least two capacitors must be used with the auxiliary winding.

Motors with two capacitors are called capacitor-start, capacitor-run, or two-value capacitor motors.

The larger capacitor is present in the circuit only during starting when it ensures that the currents in the main and auxiliary windings are roughly balanced, yielding a relatively high starting torque.

When the motor runs up to speed, the centrifugal switch opens, and the permanent capacitor is left by itself in the auxiliary winding circuit. The permanent capacitor is just large enough to balance the currents at normal motor loads; therefore, the motor again operates efficiently with good power factor.

Page 68: Papers on the Induction Motor Transients.

Circuit layout with a switched capacitor

This system consists of three major elements: the induction machine, the running capacitor, and an inverse/parallel set of bidirectional voltage blocking switches (e.g., reverse blocking GTO's). The main winding of the SPIM is directly connected to the supply mains.

Page 69: Papers on the Induction Motor Transients.

The switched capacitor…

It is shown that the apparent capacitance of the running capacitor can be made larger than its actual value if the capacitor is shorted periodically.

Thus, by operating the switch on and off regularly during each cycle and by changing the length of the shorting interval, the effective capacitance of the capacitor can be enlarged and adjusted to an optimal value to realize the maximum possible acceleration torque for any rotor speed during run-up from standstill.

By using this method, only one capacitor is used for both starting and running conditions.