Panduit IA UPS Benefits for Zone Networks

Page 2: Panduit IA UPS Benefits for Zone Networks

2

Panduit IA UPS Benefits for Zone Networks

• Improved availability– Saves minutes of switch restart

time after brief power interruptions

• Lower risk of downtime– No Battery eliminates the #1

cause of UPS failures– Maintenance-free removes

dependency on preventative maintenance

Top root causes of downtime cited by data center professionals. Totals exceed 100 percent because data center professionals cited multiple root-causes over a period of two years.

Page 3: Panduit IA UPS Benefits for Zone Networks

3

Panduit IA UPS Benefits for Zone Networks

• Lower Cost of Ownership– Maintenance-free saves time

and costs of battery inspections, testing, replacement and disposal

– Longer life, up to 20 years, with less derating at high temperatures

Page 4: Panduit IA UPS Benefits for Zone Networks

4

Panduit IA UPS Benefits for Zone Networks

• Improved Device Management – No proprietary software to download, install, configure, learn and support– No need to “visit” each device with a laptop to check health– Remote management from office, plant floor or mobile devices– Multiple device management– Plug-and-play on FactoryTalk® networks

• Predictive Monitoring– Hold Time based on actual load consumption, whether in primary or secondary

power supply path– “Life Time” remaining to 80% of original capacity, integrates temperature

variations over time

FactoryTalk® is registered by Rockwell Automation in the Patent and Trademark Office of the United States.

Page 5: Panduit IA UPS Benefits for Zone Networks

5

Panduit IA UPS Benefits for Zone Networks

• Better Integration– Smaller width saves valuable space on the DIN rail– Single device installs more easily without interconnections– Wide operating temperature from -40 to +60° C (-40 to +140°F)– No HazMat disposal of lead acid batteries– No chance of Hydrogen outgassing, no need to vent

• Zone Monitoring– Power Supply A and B outputs, and load current– Proxy for enclosure inside temperature

Page 6: Panduit IA UPS Benefits for Zone Networks

6

UPS Faceplate on A-B HMI

• Panduit UPS is the only DC UPS with an

Ethernet interface

– Alternatives are expensive rack mount, AC units

intended for Data Center environments

– Allows remote monitoring Zone Network “health” –

Power Supplies and Temperature

• EtherNet/IP CONFORMANCE TESTED™ for

easy plug-and-play integration with Rockwell

Automation FactoryTalk® network devices

– EtherNet/IP™ and FactoryTalk® Network support

files downloadable

Remote Management withFactoryTalk® View Faceplate

FactoryTalk® is registered by Rockwell Automation in the Patent and Trademark Office of the United States.

EtherNet/IP CONFORMANCE TESTED™ is a certification mark of ODVA.

EtherNET/IP trademark of ODVA.