For technical assistance in the U.S., call 866-405-6654 (outside the U.S., see inside back cover for directory) ELECTRICAL SOLUTIONS C1.1 B2. Cable Accessories C1. Wiring Duct C3. Abrasion Protection C4. Cable Management D1. Terminals D2. Power Connectors E1. Labeling Systems E2. Labels E3. Pre-Printed & Write-On Markers F. Index B3. Stainless Steel Ties C2. Surface Raceway E5. Lockout/ Tagout & Safety Solutions B1. Cable Ties A. System Overview D3. Grounding Connectors E4. Permanent Identification From the smallest wall mounted panels to the largest integrated turnkey systems Panduit ® Panduct ® Wiring Duct is the premium wire management solution for routing and concealing wiring in electrical control panels. Panduct ® Wiring Duct provide solutions for the original equipment manufacturing, transportation, contract manufacturing, maintenance and repair and communications markets. All Panduct ® Wiring Duct are UL Recognized and CSA Certified and most carry the CE mark. WIRING DUCT Panduit continues to develop new Panduct ® Wiring Duct solutions to satisfy the challenges facing our customers worldwide. Maximize the utilization of enclosure space with PanelMax ™ Corner Wiring Duct, DIN Rail Wiring Duct, and Noise Shield. PanelMax ™ Corner Wiring Duct fits into unused space in the corner of enclosures providing up to 20% enclosure space savings*.Integrate component mounting with wire management with PanelMax ™ DIN Rail Wiring Duct for up to 30% enclosure space savings. PanelMax ™ Noise Shield provides noise mitigation between noisy and sensitive cabling and can reduce air space requirements within the enclosure. Some of the features and benefits found in Panduct ® Wiring Duct include: • Smooth corners and edges that will not abrade wiring or irritate hands • Integrated nonskid liners and unique cover designs insure the duct cover will not slide once installed or during vibration • Specially formulated lead-free PVC material meets the NFPA79: 2007 flame retardancy requirements and carries a UL 94V-0 flammability rating • Scorelines for easy removal of duct fingers and sidewalls • Accessories and tools that increase productivity and lower the installed cost *Versus panel layouts using conventional wiring duct. Courtesy of Steven Engineering, Inc. - (800) 258-9200 - [email protected] - www.stevenengineering.com
63
Embed
Panduit Electrical Solutions Catalog - Wiring Duct · 2018. 6. 2. · Panduit® PanelMaxTM DIN Rail Wiring Duct positions DIN rail and components off the panel directly above an integrated
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
For technical assistance in the U.S., call 866-405-6654 (outside the U.S., see inside back cover for directory)
ELECTRICAL SOLUTIONS
C1.1
B2.Cable
Accessories
C1.Wiring
Duct
C3.Abrasion
Protection
C4.Cable
Management
D1.Terminals
D2.Power
Connectors
E1.LabelingSystems
E2.Labels
E3.Pre-Printed & Write-On
Markers
F.Index
B3.StainlessSteel Ties
C2.Surface
Raceway
E5.Lockout/Tagout
& SafetySolutions
B1.Cable Ties
A.System
Overview
D3.GroundingConnectors
E4.Permanent
Identification
From the smallest wall mounted panels to the largest integrated turnkey systems Panduit ® Panduct ®
Wiring Duct is the premium wire management solution for routing and concealing wiring in electrical
control panels. Panduct ® Wiring Duct provide solutions for the original equipment manufacturing,
transportation, contract manufacturing, maintenance and repair and communications markets.
All Panduct ® Wiring Duct are UL Recognized and CSA Certified and most carry the CE mark.
WIRING DUCT
Panduit continues to develop new Panduct ® Wiring Duct solutions to satisfy the challenges facing our
customers worldwide. Maximize the utilization of enclosure space with PanelMax ™ Corner Wiring Duct,
DIN Rail Wiring Duct, and Noise Shield. PanelMax ™ Corner Wiring Duct fits into unused space in the
corner of enclosures providing up to 20% enclosure space savings*. Integrate component mounting with
wire management with PanelMax ™ DIN Rail Wiring Duct for up to 30% enclosure space savings.
PanelMax ™ Noise Shield provides noise mitigation between noisy and sensitive cabling and can reduce
air space requirements within the enclosure.
Some of the features and benefits found inPanduct ® Wiring Duct include:
• Smooth corners and edges that will not abrade wiring or irritate hands
• Integrated nonskid liners and unique coverdesigns insure the duct cover will not slideonce installed or during vibration
• Specially formulated lead-free PVC material meets the NFPA79: 2007 flame retardancy requirements and carries a UL 94V-0 flammability rating
• Scorelines for easy removal of duct fingersand sidewalls
• Accessories and tools that increase productivity and lower the installed cost
*Versus panel layouts using conventional wiring duct.
Courtesy of Steven Engineering, Inc. - (800) 258-9200 - [email protected] - www.stevenengineering.com
ELECTRICAL SOLUTIONS
C1.2
B2.Cable
Accessories
C1.Wiring
Duct
C3.Abrasion
Protection
C4.Cable
Management
D1.Terminals
D2.Power
Connectors
E1.LabelingSystems
E2.Labels
E3.Pre-Printed & Write-On
Markers
F.Index
B3.StainlessSteel Ties
C2.Surface
Raceway
E5.Lockout/Tagout
& SafetySolutions
B1.Cable Ties
A.System
Overview
D3.GroundingConnectors
E4.Permanent
Identification
Wiring Duct for Control Panel Applications
PanelMax™ DIN Rail Wiring DuctUp to 30% space savings vs.conventional duct/rail layouts.
(pages C1.4 – C1.5)
PanelMax™
Noise ShieldInstalled separately or
within wiring duct.
(pages C1.6 – C1.7)
PanelMax™ CornerWiring DuctUp to 20% space savings inlayouts with side and back panels
(pages C1.8 – C1.9)
Hinged Cover Wiring Duct and RacewayWide slot, narrow slot
wiring duct and solid wall
raceway with hinging cover.
(pages C1.10 – C1.11)
Halogen Free Wiring DuctUp to 203°F (95°C)operating temperature.
(pages C1.22 – C1.24)
1
2
3
4
1
3
4
5
2
Courtesy of Steven Engineering, Inc. - (800) 258-9200 - [email protected] - www.stevenengineering.com
For technical assistance in the U.S., call 866-405-6654 (outside the U.S., see inside back cover for directory)
ELECTRICAL SOLUTIONS
C1.3
B2.Cable
Accessories
C1.Wiring
Duct
C3.Abrasion
Protection
C4.Cable
Management
D1.Terminals
D2.Power
Connectors
E1.LabelingSystems
E2.Labels
E3.Pre-Printed & Write-On
Markers
F.Index
B3.StainlessSteel Ties
C2.Surface
Raceway
E5.Lockout/Tagout
& SafetySolutions
B1.Cable Ties
A.System
Overview
D3.GroundingConnectors
E4.Permanent
Identification
Type F Narrow Slot Wiring Duct
Narrow slot, narrow finger design fits the
spacing of high-density terminal blocks.
(pages C1.14 – C1.15)
5
Type G Wide Slot Wiring Duct
Wide slot, widefinger design.
(pages C1.12 – C1.13)
Type D Round Hole Wiring Duct
Multiple rows of holesto retain and support
wire of variable heights and positions.
(pages C1.16 – C1.17)
Type MC Metric Wiring Duct
Narrow slot, narrow finger design with DIN 43 659
mounting holes.
(pages C1.18 – C1.19)
Type FL Flexible Wiring Duct
Solution for door mounted push-button wiring or tight
spaces without cover access.
(page C1.26)
6
Tools and Accessories(pages C1.25 – C1.34)
3
6
5
2
Courtesy of Steven Engineering, Inc. - (800) 258-9200 - [email protected] - www.stevenengineering.com
ELECTRICAL SOLUTIONS
Order number of pieces required, in multiples of Standard Package Quantity.C1.4
B2.Cable
Accessories
C1.Wiring
Duct
C3.Abrasion
Protection
C4.Cable
Management
D1.Terminals
D2.Power
Connectors
E1.LabelingSystems
E2.Labels
E3.Pre-Printed & Write-On
Markers
F.Index
B3.StainlessSteel Ties
C2.Surface
Raceway
E5.Lockout/Tagout
& SafetySolutions
B1.Cable Ties
A.System
Overview
D3.GroundingConnectors
E4.Permanent
Identification
Features and Benefits – Panduct ® PanelMax ™ DIN Rail Wiring Duct
Locating ribsalign and center DIN railduring installation
DIN rail and DIN component compatible
Integrated fastener slot accepts supplied screw fasteners to install DIN rail (user supplied rail)
Unique finger/slotprogression for aestheticsand maximum slot capacity
Pass-through holes shorten the wiring path between components on the same DIN rail
Hinged and flexible cover acts as ledge for wire installation andflexes for easy opening and increasedchannel access for maintenance
Conventional Wiring Duct Panel Layout:
DIN Rail Wiring Duct Panel Layout with 30% Space Savings:
Panduit ® PanelMaxTM DIN Rail Wiring Duct positions DIN rail and components off the panel directly above an integrated wire management channel for a 30%+ smaller footprint to the panel layout.
Courtesy of Steven Engineering, Inc. - (800) 258-9200 - [email protected] - www.stevenengineering.com
For technical assistance in the U.S., call 866-405-6654 (outside the U.S., see inside back cover for directory)
ELECTRICAL SOLUTIONS
C1.5
B2.Cable
Accessories
C1.Wiring
Duct
C3.Abrasion
Protection
C4.Cable
Management
D1.Terminals
D2.Power
Connectors
E1.LabelingSystems
E2.Labels
E3.Pre-Printed & Write-On
Markers
F.Index
B3.StainlessSteel Ties
C2.Surface
Raceway
E5.Lockout/Tagout
& SafetySolutions
B1.Cable Ties
A.System
Overview
D3.GroundingConnectors
E4.Permanent
Identification
Panduct ® PanelMax ™ DIN Rail Wiring Duct
Product sold base and cover together in 6 ft. lengths. Replace LG with WH for white color.
DRD
DRDWR
DRDCS
• Space saving design positions DIN rail and components off thepanel directly above an integrated wire management channel for up to a 30% smaller footprint for duct and components;increased design flexibility and component access for easierinstallation and maintenance
• DIN rail and DIN component compatible with standard 35mm or 15mm rails and many DIN rail mount components for design flexibility
• Integrated DIN rail fastening slot allows the DIN rail to mountdirectly to product with plastic thread cutting screws for up to 40% faster duct and rail installation and reduced labor costs
• Hinged cover remains attached during maintenance and upgradespreventing lost covers, ensuring panel integrity, safety andaesthetics; L-shaped cover acts as ledge to aid wire installation for ease of use
• Slotted platform (horizontal) manage the wire from channelmounted components, outer sidewall slots (vertical) manage wirefrom adjacent panel mounted components; unique finger and slotprogression for optimal wire management and aesthetics
• Channel pass through slots allows wires to transition internallybetween channels to ease wire connections to either side of components mounted on the same rail minimizingwire length and reducing material cost
• Optional wire retainer accessory retains cabling with cover opened or removed easing wire installation and future wire additions
Part Number Part Description
Std.Pkg.Qty.
Std.Ctn.Qty.
DRD22LG6 2" height PanelMax ™ DIN Rail Wiring Duct with dual wiring channels. Base, covers and DIN rail fasteners included.
6 Ft. 6 Ft.
DRD33LG6 3" height PanelMax ™ DIN Rail Wiring Duct with dual wiringchannels. Base, covers and DIN rail fasteners included.
6 Ft. 6 Ft.
DRD44LG6 4" height PanelMax ™ DIN Rail Wiring Duct with dual wiring channels. Base, covers and DIN rail fasteners included.
6 Ft. 6 Ft.
DRDC2LG6 2" replacement cover for PanelMax ™ DIN Rail Wiring Duct.
6 Ft. 24 Ft.
DRDC3LG6 3" replacement cover for PanelMax ™ DIN Rail Wiring Duct.
6 Ft. 24 Ft.
DRDC4LG6 4" replacement cover for PanelMax ™ DIN Rail Wiring Duct.
6 Ft. 24 Ft.
DRDSF-C Replacement DIN rail fasteners for PanelMax ™
DIN Rail Wiring Duct.100 —
DRDWR2-X 2" wire retainer for PanelMax ™ DIN Rail Wiring Duct. 10 100
DRDWR3-X 3" wire retainer for PanelMax ™ DIN Rail Wiring Duct. 10 100
DRDWR4-X 4" wire retainer for PanelMax ™ DIN Rail Wiring Duct. 10 100
DRDCS2-X 2" corner strip for PanelMax ™ DIN Rail Wiring Duct. 10 100
DRDCS3-X 3" corner strip for PanelMax ™ DIN Rail Wiring Duct. 10 100
DRDCS4-X 4" corner strip for PanelMax ™ DIN Rail Wiring Duct. 10 100
Courtesy of Steven Engineering, Inc. - (800) 258-9200 - [email protected] - www.stevenengineering.com
ELECTRICAL SOLUTIONS
Order number of pieces required, in multiples of Standard Package Quantity.C1.6
B2.Cable
Accessories
C1.Wiring
Duct
C3.Abrasion
Protection
C4.Cable
Management
D1.Terminals
D2.Power
Connectors
E1.LabelingSystems
E2.Labels
E3.Pre-Printed & Write-On
Markers
F.Index
B3.StainlessSteel Ties
C2.Surface
Raceway
E5.Lockout/Tagout
& SafetySolutions
B1.Cable Ties
A.System
Overview
D3.GroundingConnectors
E4.Permanent
Identification
Features and Benefits – Panduct ® PanelMax ™ Noise Shield
Metal noise barrier reduces EMI noise couplingup to 20dB, equal to 6 inchesair spacing
Perforated pre-scored sectionsaid cutting to length
Bonding clip allows shield usewithin wiring duct
Vertical wire slots for wire pass through
Cable ties slots integrated into shieldfor cable management
Durable blackpowder coatfor smooth edges
Metal noise barrierequivalent to 6 inches of air spacingbetween power and signal cables,saves valuable panel space.
PanelMax™ Noise Shield separates drive cables and sensitivecommunication/signal cables withinindustrial control panels to reduceelectromagnetic interference (EMI)while saving valuable space.
Perforated and pre-scored sectionsmake it easy to cut to length withminimal deburring required.
Courtesy of Steven Engineering, Inc. - (800) 258-9200 - [email protected] - www.stevenengineering.com
For technical assistance in the U.S., call 866-405-6654 (outside the U.S., see inside back cover for directory)
ELECTRICAL SOLUTIONS
C1.7
B2.Cable
Accessories
C1.Wiring
Duct
C3.Abrasion
Protection
C4.Cable
Management
D1.Terminals
D2.Power
Connectors
E1.LabelingSystems
E2.Labels
E3.Pre-Printed & Write-On
Markers
F.Index
B3.StainlessSteel Ties
C2.Surface
Raceway
E5.Lockout/Tagout
& SafetySolutions
B1.Cable Ties
A.System
Overview
D3.GroundingConnectors
E4.Permanent
Identification
Panduct ® PanelMax ™ Noise Shield• Metal noise barrier reduces EMI noise coupling between noise
emitting and sensitive cabling within a control panel; provides up to 20dB reduction in noise which is equivalent to 6 inches of air spacing
• Installs directly to metal panel surface or within 2, 3, or 4 inchheight Panduit wiring duct (when shield is installed with suppliedbonding clips)
• Perforated and pre-scored sections speed installation by allowingsections of the shield to be snapped off at pre-scored locations to easily cut to length with minimal deburring required
• Vertical wall slots allow wires to cross the barrier at 90° when necessary, providing greater design flexibility
• Horizontal cable tie slots allow cable bundles to be held in place using cable ties so cabling is kept near barrier for greaterreliability and optimal aesthetics
• Zinc plated steel surface in contact areas with sub-panel and bonding clip ensures continuity and is corrosion resistant
• Black powder coated vertical surface for smooth edges
• Meets UL 508/508A requirements as a barrier between conductors
Performance Characteristics
Noise Coupling vs. FrequencyNoise Frequency (MHz)
No
ise
Co
up
ling
(d
B)
PanelMax™ Noise Shield delivers approximately 20dB of noisereduction across common industrial noise frequencies at 30mm wire separation.
0
-10
-20
-30
-40
-50
0 2.0 4.0 6.0 8.0 10.0
No Shield
PanelMax™
NoiseShield
Relative noise reduction in dB over frequency range of the PanelMax™ Noise Shield is shown below.
Part Number Part Description
Std.Pkg.Qty.
SD2EMI EMI Noise Shield kit for 2" height Panduit Wiring Duct; (2) three footsections, bonding clips, and anti-oxidizing paste.
1
SD3EMI EMI Noise Shield kit for 3" height Panduit Wiring Duct; (2) three footsections, bonding clips, and anti-oxidizing paste.
1
SD4EMI EMI Noise Shield kit for 4" height Panduit Wiring Duct; (2) three footsections, bonding clips, and anti-oxidizing paste.
1
Courtesy of Steven Engineering, Inc. - (800) 258-9200 - [email protected] - www.stevenengineering.com
ELECTRICAL SOLUTIONS
Order number of pieces required, in multiples of Standard Package Quantity.C1.8
B2.Cable
Accessories
C1.Wiring
Duct
C3.Abrasion
Protection
C4.Cable
Management
D1.Terminals
D2.Power
Connectors
E1.LabelingSystems
E2.Labels
E3.Pre-Printed & Write-On
Markers
F.Index
B3.StainlessSteel Ties
C2.Surface
Raceway
E5.Lockout/Tagout
& SafetySolutions
B1.Cable Ties
A.System
Overview
D3.GroundingConnectors
E4.Permanent
Identification
ConventionalWiring Duct
Space Savings withPanelMax ™ CornerWiring Duct
UnusedPanel Space
Space is lost atthe edges of themounting panels.
PanelSpace Gain
Up to 5 square feet ofadditional mounting spacegained per enclosure.*
Enclosure cornertop view
*Actual subpanel space savings will vary depending on wiring duct size, component layout, and enclosure size and type. Footprint savings is based oncommercially available enclosures and may not be achievable in some applications.
Features and Benefits – Panduct ® PanelMax ™ Corner Wiring Duct
Panduct ® Divider WallCreates separate wiring channelswithin the wiring duct base. Availablein solid or slotted wall styles.(see page C1.26)
Up to a 20% reduction in enclosure footprint size ispossible vs. a conventional wiring duct installation.*
Panduct ® Installation ToolsWide selection of hand tools for cutting and installing wiring duct.(see page C1.34)
Panduct ® Type C Coverwith Protective FilmReduces scrap and labor costsby protecting the surface duringstorage, handling, and installation.(see page C1.9)
One-piece basereduces fastenersrequired for minimalinstallation time
Features and Benefits – Panduct ® Type H and HN Hinged Cover Wiring Duct
Available in eight sizes from 1.5" x 2" up to 4" x 4" in light gray, black, and white colors.
Labor Savings
■ By avoiding the time and hassle in removing and replacing covers, simple wiring changes can be made up to 20% fastercompared to conventional wiring duct installations*
■ Covers represent 20% of the cost of the wiring duct purchase
■ Misplaced covers are a common occurrence afteryears of use
■ Not needing to remove covers during maintenanceensures better aesthetics and safety and avoidsthe cost to replace lost covers
Avoid Cover Replacement Costs % of Wiring Duct Cost
20% 40% 60% 80% 100%0%
Base Cover
*Based on mock panel installations of type H hinged cover wiring duct and other commonly available wiring ducts adding a single component with four wires.
Courtesy of Steven Engineering, Inc. - (800) 258-9200 - [email protected] - www.stevenengineering.com
For technical assistance in the U.S., call 866-405-6654 (outside the U.S., see inside back cover for directory)
ELECTRICAL SOLUTIONS
C1.11
B2.Cable
Accessories
C1.Wiring
Duct
C3.Abrasion
Protection
C4.Cable
Management
D1.Terminals
D2.Power
Connectors
E1.LabelingSystems
E2.Labels
E3.Pre-Printed & Write-On
Markers
F.Index
B3.StainlessSteel Ties
C2.Surface
Raceway
E5.Lockout/Tagout
& SafetySolutions
B1.Cable Ties
A.System
Overview
D3.GroundingConnectors
E4.Permanent
Identification
Panduct ® Type HN Hinged Cover Narrow Slot Wiring Duct• Narrow slot/finger design provides excellent wire management with
smaller wire diameters and high-density components such asterminal blocks, input/output devices, and other hardware
• Material: Lead-free PVC
• UL Recognized continuous use temperature: 122°F (50°C)
• UL 94 flammability rating of V-0
• Conforms with NFPA 79-2007 section 13.3.1 requirement for flame retardant material
• Provided with mounting holes
• Base and cover length is 6 feet
Part Number shown for LG (Light Gray). Available in WH (White).Base and cover sold separately.*“H” dimension includes duct and cover.
.20 TYP [5.0]
.50 TYP [12.7]
Multiple slot restrictors present with2" and greater duct wall height.
Panduct ® Type H Hinged Cover Wide Slot Wiring Duct• Wide slot/finger design provides excellent wire management in
general purpose applications and is compatible with a wide range of wire sizes and component types
• Material: Lead-free PVC
• Rated for continuous use temperature: 122°F (50°C)
• UL 94 flammability rating of V-0
• Conforms with NFPA 79-2007 section 13.3.1 requirement for flame retardant material
• Provided with standard mounting holes
• Base and cover length is 6 ft.
Part Number shown for LG (Light Gray). Available in BL (Black) and WH (White).Base and cover sold separately.*“H” dimension includes duct and cover.W
H
W
H
W
H
Panduct ® Type HS Hinged Cover Solid Wall Raceway• Solid wall raceway conceals and protects wiring in continuous runs
such as in low-voltage cord management applications betweencontrol panel stations in conveyor systems
• Material: Lead-free PVC
• UL recognized continuous use temperature: 122°F (50°C)
• UL 94 flammability rating of V-0
• Supplied without mounting holes
• Base and cover length is 6 feet
Part Number shown for LG (Light Gray). For BL (Black) and WH (White) colors see color selection guide,page C1.48.Base and cover sold separately.*“H” dimension includes duct and cover.
For 2" duct height: .31" [7.9] .80" [20.3]3" to 4" duct height: .31" [7.9] 1.00" [25.4]
FE
F
E
BasePart Number
Duct Size (W x H)* Slot Width Cover PartNumber
Std.Pkg.Qty
BaseCtn.Qty.
CoverCtn.Qty.In. mm In. mm
H1.5X2LG6 1.75 x 1.98 44.5 x 50.3 .31 7.9 HC1.5LG6 6 120 120H1.5X3LG6 1.75 x 3.06 44.5 x 77.7 .31 7.9 HC1.5LG6 6 120 120H2X2LG6 2.17 x 1.98 55.1 x 50.3 .31 7.9 HC2LG6 6 120 120H2X3LG6 2.17 x 3.06 55.1 x 77.7 .31 7.9 HC2LG6 6 60 120H2X4LG6 2.17 x 4.10 55.1 x 104.1 .31 7.9 HC2LG6 6 60 120H3X3LG6 3.25 x 3.06 82.6 x 77.7 .31 7.9 HC3LG6 6 60 120H3X4LG6 3.25 x 4.10 82.6 x 104.1 .31 7.9 HC3LG6 6 60 120H4X4LG6 4.25 x 4.10 108.0 x 104.1 .31 7.9 HC4LG6 6 60 60
BasePart Number
Duct Size (W x H)* CoverPart Number
Std.Pkg.Qty.
BaseCtn.Qty.
CoverCtn.Qty.In. mm
HS1.5X2LG6NM 1.75 x 1.98 44.5 x 50.3 HC1.5LG6 6 120 120HS1.5X3LG6NM 1.75 x 3.06 44.5 x 77.7 HC1.5LG6 6 60 120HS2X2LG6NM 2.17 x 1.98 55.1 x 50.3 HC2LG6 6 120 120HS2X3LG6NM 2.17 x 3.06 55.1 x 77.7 HC2LG6 6 60 120HS2X4LG6NM 2.17 x 4.10 55.1 x 104.1 HC2LG6 6 60 120HS3X3LG6NM 3.25 x 3.06 82.6 x 77.7 HC3LG6 6 60 120HS3X4LG6NM 3.25 x 4.10 82.6 x 104.1 HC3LG6 6 60 120HS4X4LG6NM 4.25 x 4.10 108.0 x 104.1 HC4LG6 6 60 60
BasePart Number
Duct Size (W x H)* Slot Width Cover PartNumber
Std.Pkg.Qty
BaseCtn.Qty.
CoverCtn.Qty.In. mm In. mm
HN1.5X2LG6 1.75 x 1.98 44.5 x 50.3 0.20 5.0 HC1.5LG6 6 120 120HN1.5X3LG6 1.75 x 3.06 44.5 x 77.7 0.20 5.0 HC1.5LG6 6 120 120HN2X2LG6 2.17 x 1.98 55.1 x 50.3 0.20 5.0 HC2LG6 6 120 120HN2X3LG6 2.17 x 3.06 55.1 x 77.7 0.20 5.0 HC2LG6 6 60 120HN2X4LG6 2.17 x 4.10 55.1 x 104.1 0.20 5.0 HC2LG6 6 60 120HN3X3LG6 3.25 x 3.06 82.6 x 77.7 0.20 5.0 HC3LG6 6 60 120HN3X4LG6 3.25 x 4.10 82.6 x 104.1 0.20 5.0 HC3LG6 6 60 120HN4X4LG6 4.25 x 4.10 108.0 x 104.1 0.20 5.0 HC4LG6 6 60 60
Courtesy of Steven Engineering, Inc. - (800) 258-9200 - [email protected] - www.stevenengineering.com
ELECTRICAL SOLUTIONS
Order number of pieces required, in multiples of Standard Package Quantity.C1.12
Panduct ® Type C Coverwith Protective FilmReduces scrap and labor costsby protecting the surface duringstorage, handling, and installation.See page C1.13.
Courtesy of Steven Engineering, Inc. - (800) 258-9200 - [email protected] - www.stevenengineering.com
For technical assistance in the U.S., call 866-405-6654 (outside the U.S., see inside back cover for directory)
ELECTRICAL SOLUTIONS
C1.13
B2.Cable
Accessories
C1.Wiring
Duct
C3.Abrasion
Protection
C4.Cable
Management
D1.Terminals
D2.Power
Connectors
E1.LabelingSystems
E2.Labels
E3.Pre-Printed & Write-On
Markers
F.Index
B3.StainlessSteel Ties
C2.Surface
Raceway
E5.Lockout/Tagout
& SafetySolutions
B1.Cable Ties
A.System
Overview
D3.GroundingConnectors
E4.Permanent
Identification
Panduct ® Type G Wide Slot Wiring Duct• Wide slot/finger design provides greater sidewall rigidity and can
be used with a wide range of wire bundle sizes
• Material: Lead-free PVC
• UL recognized continuous use temperature: 122°F (50°C)
• UL 94 flammability rating of V-0
• Conforms with NFPA 79-2007 section 13.3.1 requirement for flame retardant material
• Provided with mounting holes
• Base and cover length is 6 feet
Part number shown for LG (Light Gray). For other color availability see color selection guide, page C1.48.Base and cover sold separately.*“H” dimension includes duct and cover.
W
H
To order cover with protective filmadd “-F” to part number. 6" covernot available with film.
Panduct ® Type C Coverwith Protective FilmReduces scrap and labor costsby protecting the surface duringstorage, handling, and installation.(see page C1.15)
Courtesy of Steven Engineering, Inc. - (800) 258-9200 - [email protected] - www.stevenengineering.com
For technical assistance in the U.S., call 866-405-6654 (outside the U.S., see inside back cover for directory)
ELECTRICAL SOLUTIONS
C1.15
B2.Cable
Accessories
C1.Wiring
Duct
C3.Abrasion
Protection
C4.Cable
Management
D1.Terminals
D2.Power
Connectors
E1.LabelingSystems
E2.Labels
E3.Pre-Printed & Write-On
Markers
F.Index
B3.StainlessSteel Ties
C2.Surface
Raceway
E5.Lockout/Tagout
& SafetySolutions
B1.Cable Ties
A.System
Overview
D3.GroundingConnectors
E4.Permanent
Identification
Panduct ® Type F Narrow Slot Wiring Duct
• Narrow slot/finger design provides more slots to fit the spacing ofhigh-density terminal blocks and other hardware
• Material: Lead-free PVC
• UL recognized continuous use temperature: 122°F (50°C)
• UL 94 flammability rating of V-0
• Conforms with NFPA 79-2007 section 13.3.1 requirement for flame retardant material
• Provided with mounting holes
• Base and cover length is 6 feet
Part number shown for LG (Light Gray). For other color availability see color selection guide, page C1.48.Base and cover sold separately.*“H” dimension includes duct and cover.
W
H
.20 TYP [5.0]
.50 TYP [12.7]
Multiple slot restrictors present with2" and greater duct wall height.
To order cover with protective filmadd “-F” to part number. 6" covernot available with film.
BasePart Number
Duct Size (W x H)* Slot Width CoverPart Number
Std.Pkg.Qty.
BaseCtn.Qty.
CoverCtn.Qty.In. mm In. mm
F.5X.5LG6 0.69 x 0.60 17.5 x 15.2 0.20 5.0 C.5LG6 6 120 120
F.5X1LG6 0.69 x 1.06 17.5 x 26.9 0.20 5.0 C.5LG6 6 120 120
F.75X.75LG6 0.93 x 0.82 23.6 x 20.9 0.20 5.0 C.75LG6 6 120 120
F.75X1.5LG6 0.93 x 1.57 23.6 x 39.9 0.20 5.0 C.75LG6 6 120 120
F1X1LG6 1.26 x 1.13 32.0 x 28.7 0.20 5.0 C1LG6 6 120 120
F1X1.5LG6 1.26 x 1.62 32.0 x 41.1 0.20 5.0 C1LG6 6 120 120
F1X2LG6 1.26 x 2.12 32.0 x 53.8 0.20 5.0 C1LG6 6 120 120
F1X3LG6 1.26 x 3.12 32.0 x 79.2 0.20 5.0 C1LG6 6 120 120
F1X4LG6 1.26 x 4.10 32.0 x 104.1 0.20 5.0 C1LG6 6 60 120
F1.5X1LG6 1.75 x 1.12 44.5 x 28.4 0.20 5.0 C1.5LG6 6 120 120
F1.5X1.5LG6 1.75 x 1.62 44.5 x 41.1 0.20 5.0 C1.5LG6 6 120 120
F1.5X2LG6 1.75 x 2.12 44.5 x 53.8 0.20 5.0 C1.5LG6 6 120 120
F1.5X3LG6 1.75 x 3.12 44.5 x 79.2 0.20 5.0 C1.5LG6 6 120 120
F1.5X4LG6 1.75 x 4.10 44.5 x 104.1 0.20 5.0 C1.5LG6 6 60 120
F2X1LG6 2.25 x 1.12 57.2 x 28.4 0.20 5.0 C2LG6 6 120 120
F2X1.5LG6 2.25 x 1.62 57.2 x 41.1 0.20 5.0 C2LG6 6 120 120
F2X2LG6 2.25 x 2.12 57.2 x 53.8 0.20 5.0 C2LG6 6 120 120
F2X3LG6 2.25 x 3.12 57.2 x 79.2 0.20 5.0 C2LG6 6 60 120
F2X4LG6 2.25 x 4.10 57.2 x 104.1 0.20 5.0 C2LG6 6 60 120
F2X5LG6 2.25 x 5.10 57.2 x 129.5 0.20 5.0 C2LG6 6 60 120
F2.5X3LG6 2.75 x 3.12 69.9 x 79.2 0.20 5.0 C2.5LG6 6 120 120
F3X1LG6 3.25 x 1.12 82.6 x 28.4 0.20 5.0 C3LG6 6 120 120
F3X2LG6 3.25 x 2.12 82.6 x 53.8 0.20 5.0 C3LG6 6 120 120
F3X3LG6 3.25 x 3.12 82.6 x 79.2 0.20 5.0 C3LG6 6 60 120
F3X4LG6 3.25 x 4.10 82.6 x 104.1 0.20 5.0 C3LG6 6 60 120
F3X5LG6 3.25 x 5.10 82.6 x 129.5 0.20 5.0 C3LG6 6 60 120
F4X2LG6 4.25 x 2.12 108.0 x 53.8 0.20 5.0 C4LG6 6 60 120
F4X3LG6 4.25 x 3.12 108.0 x 79.2 0.20 5.0 C4LG6 6 60 120
F4X4LG6 4.25 x 4.10 108.0 x 104.1 0.20 5.0 C4LG6 6 60 120
F4X5LG6 4.25 x 5.10 108.0 x 129.5 0.20 5.0 C4LG6 6 60 120
F6X4LG6 6.25 x 4.15 158.8 x 105.4 0.20 5.0 C6LG6 6 60 120
Courtesy of Steven Engineering, Inc. - (800) 258-9200 - [email protected] - www.stevenengineering.com
ELECTRICAL SOLUTIONS
Order number of pieces required, in multiples of Standard Package Quantity.C1.16
Base scoreline allows easy removalof sidewall section at t-junctions andright angles, saving installation time
Flush cover designprovides a neat andfinished appearance
Specially formulatedlead-free PVCmaterial
Features and Benefits – Panduct ® Flush Cover Type D Round Hole Wiring Duct
Available in sixteen sizes from 1" x 2" up to 4" x 4" in a variety of colors.
Panduct ® Wire Retainers for Type D Wiring Duct Contain wiring when duct cover is opened. Wire retainers mount onto walls with pressure sensitive adhesive.(see page C1.28)
Panduct ® Installation ToolsWide selection of hand tools for cutting and installing wiring duct.(see page C1.34)
Panduct ® Divider WallCreate separate wiring channels within the wiring duct base. Availablein solid or slotted wall styles.(see page C1.26)
Panduct ® Type C Coverwith Protective FilmReduces scrap and labor costsby protecting the surface duringstorage, handling, and installation.(see page C1.17)
Courtesy of Steven Engineering, Inc. - (800) 258-9200 - [email protected] - www.stevenengineering.com
For technical assistance in the U.S., call 866-405-6654 (outside the U.S., see inside back cover for directory)
ELECTRICAL SOLUTIONS
C1.17
B2.Cable
Accessories
C1.Wiring
Duct
C3.Abrasion
Protection
C4.Cable
Management
D1.Terminals
D2.Power
Connectors
E1.LabelingSystems
E2.Labels
E3.Pre-Printed & Write-On
Markers
F.Index
B3.StainlessSteel Ties
C2.Surface
Raceway
E5.Lockout/Tagout
& SafetySolutions
B1.Cable Ties
A.System
Overview
D3.GroundingConnectors
E4.Permanent
Identification
Panduct ® Flush Cover Type D Round Hole Wiring Duct
• Round hole design has multiple rows of holes to retain and supportwire at variable heights and positions
• Material: Lead-free PVC
• UL recognized continuous use temperature: 122°F (50°C)
• UL 94 flammability rating of V-0
• Conforms with NFPA 79-2007 section 13.3.1 requirement for flame retardant material
• Provided with mounting holes
• Base and cover length is 6 feet
.67 + .06 TYP[16.94 + 1.5]
-
- .44 + .02 Ø
[11.2 + 0.5]-
-
For 2" duct height = 3 rows of holes 3" duct height = 4 rows of holes 4" duct height = 6 rows of holes
H
Part number shown for LG (Light Gray). For other color availability see color selection guide, page C1.48.Base and cover sold separately.*“H” dimension includes duct and cover.
W
H
To order cover with protective filmadd “-F” to part number. 6" covernot available with film.
BasePart Number
Duct Size (W x H)* CoverPart Number
Std.Pkg.Qty.
BaseCtn.Qty.
CoverCtn.Qty.In. mm
D1X2LG6 1.26 x 2.12 32.0 x 53.8 C1LG6 6 120 120
D1X3LG6 1.26 x 3.12 32.0 x 79.2 C1LG6 6 120 120
D1X4LG6 1.26 x 4.10 32.0 x 104.1 C1LG6 6 120 120
D1.5X2LG6 1.75 x 2.12 44.5 x 53.8 C1.5LG6 6 120 120
D1.5X3LG6 1.75 x 3.12 44.5 x 79.2 C1.5LG6 6 120 120
D1.5X4LG6 1.75 x 4.10 44.5 x 104.1 C1.5LG6 6 60 120
D2X2LG6 2.25 x 2.12 57.2 x 53.8 C2LG6 6 120 120
D2X3LG6 2.25 x 3.12 57.2 x 79.2 C2LG6 6 60 120
D2X4LG6 2.25 x 4.10 57.2 x 104.1 C2LG6 6 60 120
D2.5X3LG6 2.75 x 3.12 69.9 x 79.2 C2.5LG6 6 120 120
D3X2LG6 3.25 x 2.12 82.6 x 53.8 C3LG6 6 120 120
D3X3LG6 3.25 x 3.12 82.6 x 79.2 C3LG6 6 60 120
D3X4LG6 3.25 x 4.10 82.6 x 104.1 C3LG6 6 60 120
D4X2LG6 4.25 x 2.12 108.0 x 53.8 C4LG6 6 60 120
D4X3LG6 4.25 x 3.12 108.0 x 79.2 C4LG6 6 60 120
D4X4LG6 4.25 x 4.10 108.0 x 104.1 C4LG6 6 60 120
Courtesy of Steven Engineering, Inc. - (800) 258-9200 - [email protected] - www.stevenengineering.com
ELECTRICAL SOLUTIONS
Order number of pieces required, in multiples of Standard Package Quantity.C1.18
B2.Cable
Accessories
C1.Wiring
Duct
C3.Abrasion
Protection
C4.Cable
Management
D1.Terminals
D2.Power
Connectors
E1.LabelingSystems
E2.Labels
E3.Pre-Printed & Write-On
Markers
F.Index
B3.StainlessSteel Ties
C2.Surface
Raceway
E5.Lockout/Tagout
& SafetySolutions
B1.Cable Ties
A.System
Overview
D3.GroundingConnectors
E4.Permanent
Identification
Non-slip cover linerprevents cover slide
DIN 43 659 metric mountinghole pattern meets European requirementsUpper and lower scorelines allow
easy fingers and sidewall sectionremoval saving installation time
Narrow finger/slot designmatches the spacing ofhigh-density components
Flush cover design provides a neat finished appearance
Double restricted slot designretains wires, eliminating hassle andsaving time
Speciallyformulatedlead-free PVC material
Features and Benefits – Panduct ® Type MC Metric Narrow Slot Wiring Duct
Available in 20 sizes from 25mm x 25mm up to 100mm x 100mm in international gray and white colors.
Panduct ® Wire Retainers for Type MC Wiring Duct Contain wiring when duct cover isopened. Wire retainers snap easilybetween duct fingers.(see page C1.29)
Panduct ® Installation ToolsWide selection of hand tools for cutting and installing wiring duct.(see page C1.34)
Panduct ® Divider WallCreate separate wiring channels within the wiring duct base. Availablein solid or slotted wall styles.(see page C1.26)
Features and Benefits – Panduct ® Type FS Solid Wall Raceway
Available in 27 sizes from .5" x .5" up to 6" x 4" in a variety of colors.
Panduct ® Type C Coverwith Protective FilmReduces scrap and labor costsby protecting the surface duringstorage, handling, and installation.(see page C1.21)
Courtesy of Steven Engineering, Inc. - (800) 258-9200 - [email protected] - www.stevenengineering.com
>
>
>
>
>
>
>
>
>
>
>
>
>
>
>
>
>
>
>
>
>
For technical assistance in the U.S., call 866-405-6654 (outside the U.S., see inside back cover for directory)
ELECTRICAL SOLUTIONS
C1.21
B2.Cable
Accessories
C1.Wiring
Duct
C3.Abrasion
Protection
C4.Cable
Management
D1.Terminals
D2.Power
Connectors
E1.LabelingSystems
E2.Labels
E3.Pre-Printed & Write-On
Markers
F.Index
B3.StainlessSteel Ties
C2.Surface
Raceway
E5.Lockout/Tagout
& SafetySolutions
B1.Cable Ties
A.System
Overview
D3.GroundingConnectors
E4.Permanent
Identification
Panduct ® Type FS Solid Wall Raceway• Solid wall design fully encloses cables providing maximum
protection and aesthetics
• Material: Lead-free PVC
• UL recognized continuous use temperature: 122°F (50°C)
• UL 94 flammability rating of V-0
• Base and cover length is 6 feet
>Parts are available with mounting holes. To order with mounting holes, remove NM from part number.Part Number shown for LG (Light Gray). For other color availability see Color Selection Guide, page C1.48.Base and cover sold separately.*“H” dimension includes duct and cover.
W
H
To order cover with protective filmadd “-F” to part number. 6'' covernot available with film.
BasePart Number
Duct Size (W x H)* Cover Part Number
Std.Pkg.Qty.
BaseCtn.Qty.
CoverCtn.Qty.In. mm
FS.5X.5LG6NM .69 x .60 17.5 x 15.2 C.5LG6 6 120 120
FS.5X1LG6NM .69 x 1.06 17.5 x 26.9 C.5LG6 6 120 120
FS.75X.75LG6NM .93 x .82 23.6 x 20.8 C.75LG6 6 120 120
FS1X1LG6NM 1.26 x 1.12 32.0 x 28.4 C1LG6 6 120 120
FS1X1.5LG6NM 1.26 x 1.62 32.0 x 41.1 C1LG6 6 120 120
FS1X2LG6NM 1.26 x 2.12 32.0 x 53.8 C1LG6 6 120 120
FS1X3LG6NM 1.26 x 3.12 32.0 x 79.2 C1LG6 6 120 120
FS1X4LG6NM 1.26 x 4.10 32.0 x 104.1 C1LG6 6 60 120
FS1.5X1LG6NM 1.75 x 1.12 44.5 x 28.4 C1.5LG6 6 120 120
FS1.5X1.5LG6NM 1.75 x 1.62 44.5 x 41.1 C1.5LG6 6 120 120
FS1.5X2LG6NM 1.75 x 2.12 44.5 x 53.8 C1.5LG6 6 120 120
FS1.5X3LG6NM 1.75 x 3.12 44.5 x 79.2 C1.5LG6 6 120 120
FS2X1LG6NM 2.25 x 1.12 57.2 x 28.4 C2LG6 6 120 120
FS2X1.5LG6NM 2.25 x 1.62 57.2 x 41.1 C2LG6 6 120 120
FS2X2LG6NM 2.25 x 2.12 57.2 x 53.8 C2LG6 6 120 120
FS2X3LG6NM 2.25 x 3.12 57.2 x 79.2 C2LG6 6 60 120
FS2X4LG6NM 2.25 x 4.10 57.2 x 104.1 C2LG6 6 60 120
FS3X1LG6NM 3.25 x 1.12 82.6 x 28.4 C3LG6 6 120 120
FS3X2LG6NM 3.25 x 2.12 82.6 x 53.8 C3LG6 6 120 120
FS3X3LG6NM 3.25 x 3.12 82.6 x 79.2 C3LG6 6 60 120
FS3X4LG6NM 3.25 x 4.10 82.6 x 104.1 C3LG6 6 60 120
FS3X5LG6NM 3.25 x 5.10 82.6 x 129.5 C3LG6 6 60 120
FS4X2LG6NM 4.25 x 2.12 108.0 x 53.8 C4LG6 6 60 120
FS4X3LG6NM 4.25 x 3.12 108.0 x 79.2 C4LG6 6 60 120
FS4X4LG6NM 4.25 x 4.10 108.0 x 104.1 C4LG6 6 60 120
FS4X5LG6NM 4.25 x 5.10 108.0 x 129.5 C4LG6 6 60 120
FS6X4LG6NM 6.25 x 4.15 158.8 x 105.4 C6LG6 6 60 120
Courtesy of Steven Engineering, Inc. - (800) 258-9200 - [email protected] - www.stevenengineering.com
ELECTRICAL SOLUTIONS
Order number of pieces required, in multiples of Standard Package Quantity.C1.22
B2.Cable
Accessories
C1.Wiring
Duct
C3.Abrasion
Protection
C4.Cable
Management
D1.Terminals
D2.Power
Connectors
E1.LabelingSystems
E2.Labels
E3.Pre-Printed & Write-On
Markers
F.Index
B3.StainlessSteel Ties
C2.Surface
Raceway
E5.Lockout/Tagout
& SafetySolutions
B1.Cable Ties
A.System
Overview
D3.GroundingConnectors
E4.Permanent
Identification
Upper and lower scorelines allows easy finger andsidewall section removal, saving installation time
Flush cover design providesa neat and finished appearance
Non-slip coverliner preventscover slide
Halogen-free modified PPOmaterial is environmentallysafe and will not release corrosive or toxic gases
Panduct ® Type NNC Halogen-FreeSolid Divider WallCreate separate wiring channels within the wiring duct base.(see page C1.23)
material as verified with IEC 60754-2 test method (test on gasesevolved during combustion of electric cables)
• UL recognized continuous use temperature: 203°F (95°C)
• UL 94 flammability rating of V-0
• Conforms with NFPA 79-2007 section 13.3.1 requirement for flame retardant material
• Provided with DIN 43 659 mounting holes
• Metric sizing and finger progression
• Duct and cover packaged together in two meter lengths
Available in LG (Light Gray) and WH (White).Do not allow cutting, tapping, or cleaning fluids that contain hydrocarbons to come in contact with type NNC wiring duct as it will cause stress cracking. See page C1.49 for a list of chemicals to avoid.*"H" dimension includes duct and cover..39 TYP [10.0]
.98 TYP [25.0]
Multiple slot restrictors present with75mm and greater duct wall height.
Panduct ® Type NNC Divider Wall
• NNC solid divider wall can be mounted inside NNC and NE wiringduct to create multiple channels
• Simply install the divider wall base when mounting the duct and snap the divider wall onto mounting base, DB-C
Available in WH (White) color only.NOTE: Must be used with mounting base DB-C (see page C1.26), which is sold separately. Install mounting basesto the duct channel, locate within 2" of each divider wall end and at least every 12" along the length.
Part NumberLength
(m)
For NominalDuct Height
(mm)
Std.Pkg.Qty.
Std.Ctn.Qty.(m)
NNC50DWH2 2 50 2 40
NNC75DWH2 2 75 2 40
W
H
Base and CoverPart Number
Duct Size (W x H)* Slot WidthReplacement
CoverPart Number
Baseand
CoverCtn.Qty.(m)
ReplacementCoverCtn.Qty.(m)mm In. In. mm
NNC25X25LG2 24.6 x 23.6 .97 x .93 .39 10.0 NC25LG2 20 20
NNC25X37LG2 24.6 x 35.8 .97 x 1.41 .39 10.0 NC25LG2 20 20
NNC25X50LG2 24.6 x 47.8 .97 x 1.88 .39 10.0 NC25LG2 20 20
NNC25X75LG2 24.6 x 72.4 .97 x 2.85 .39 10.0 NC25LG2 20 20
NNC37X37LG2 37.1 x 35.8 1.46 x 1.41 .39 10.0 NC37LG2 20 20
NNC37X50LG2 37.1 x 47.8 1.46 x 1.88 .39 10.0 NC37LG2 20 20
NNC37X75LG2 37.1 x 72.4 1.46 x 2.85 .39 10.0 NC37LG2 20 20
NNC50X50LG2 49.5 x 47.8 1.95 x 1.88 .39 10.0 NC50LG2 20 20
NNC50X75LG2 49.5 x 72.4 1.95 x 2.85 .39 10.0 NC50LG2 10 20
NNC50X100LG2 49.5 x 97.8 1.95 x 3.85 .39 10.0 NC50LG2 10 20
NNC75X75LG2 74.7 x 72.4 2.94 x 2.85 .39 10.0 NC75LG2 10 20
NNC100X50LG2 99.6 x 47.8 3.92 x 1.88 .39 10.0 NC100LG2 10 20
NNC100X75LG2 99.6 x 72.4 3.92 x 2.85 .39 10.0 NC100LG2 10 20
NNC100X100LG2 99.6 x 97.8 3.92 x 3.85 .39 10.0 NC100LG2 10 20
Courtesy of Steven Engineering, Inc. - (800) 258-9200 - [email protected] - www.stevenengineering.com
ELECTRICAL SOLUTIONS
Order number of pieces required, in multiples of Standard Package Quantity.C1.24
• UL recognized continuous use temperature: 203°F (95°C)
• UL 94 flammability rating of V-0
• Provided with mounting holes
• Base and cover length is 6 feet
Available in WH (White) only.Do not allow cutting, tapping, or cleaning fluids that contain hydrocarbons to come in contact with type NE wiringduct as it will cause stress cracking. See page C1.49 for list of chemicals to avoid.Base and cover sold separately.*”H” dimension includes duct and cover.
NE.5X.5WH6 .63 x .56 16.0 x 14.2 .38 9.7 NC.5WH6 6 120 120
NE.5X1WH6 .63 x 1.06 16.0 x 26.9 .31 7.9 NC.5WH6 6 120 120
NE1X1WH6 1.14 x 1.06 29.0 x 26.9 .31 7.9 NC1WH6 6 120 120
NE1X1.5WH6 1.14 x 1.62 29.0 x 41.1 .31 7.9 NC1WH6 6 120 120
NE1X2WH6 1.14 x 2.06 29.0 x 52.3 .31 7.9 NC1WH6 6 120 120
NE1X3WH6 1.14 x 3.06 29.0 x 77.7 .31 7.9 NC1WH6 6 120 120
NE1X4WH6 1.14 x 4.06 29.0 x 103.1 .31 7.9 NC1WH6 6 60 120
NE1.5X1.5WH6 1.64 x 1.62 41.7 x 41.1 .31 7.9 NC1.5WH6 6 120 120
NE1.5X2WH6 1.64 x 2.06 41.7 x 52.3 .31 7.9 NC1.5WH6 6 120 120
NE1.5X3WH6 1.64 x 3.06 41.7 x 77.7 .31 7.9 NC1.5WH6 6 120 120
NE1.5X4WH6 1.64 x 4.06 41.7 x 103.1 .31 7.9 NC1.5WH6 6 60 120
NE2X1WH6 2.14 x 1.06 54.4 x 26.9 .31 7.9 NC2WH6 6 120 120
NE2X2WH6 2.14 x 2.06 54.4 x 52.3 .31 7.9 NC2WH6 6 120 120
NE2X3WH6 2.14 x 3.06 54.4 x 77.7 .31 7.9 NC2WH6 6 60 120
NE2X4WH6 2.14 x 4.06 54.4 x 103.1 .31 7.9 NC2WH6 6 60 120
NE3X1WH6 3.14 x 1.06 79.8 x 26.9 .31 7.9 NC3WH6 6 120 120
NE3X2WH6 3.14 x 2.06 79.8 x 52.3 .31 7.9 NC3WH6 6 120 120
NE3X3WH6 3.14 x 3.06 79.8 x 77.7 .31 7.9 NC3WH6 6 60 120
NE3X4WH6 3.14 x 4.06 79.8 x 103.1 .31 7.9 NC3WH6 6 60 120
NE3X5WH6 3.14 x 5.06 79.8 x 128.5 .38 9.7 NC3WH6 6 60 120
NE4X2WH6 4.14 x 2.06 105.2 x 52.3 .31 7.9 NC4WH6 6 60 120
NE4X3WH6 4.14 x 3.06 105.2 x 77.7 .31 7.9 NC4WH6 6 60 120
NE4X4WH6 4.14 x 4.06 105.2 x 103.1 .31 7.9 NC4WH6 6 60 120
NE4X5WH6 4.14 x 5.06 105.2 x 128.5 .38 9.7 NC4WH6 6 60 120
Courtesy of Steven Engineering, Inc. - (800) 258-9200 - [email protected] - www.stevenengineering.com
For technical assistance in the U.S., call 866-405-6654 (outside the U.S., see inside back cover for directory)
ELECTRICAL SOLUTIONS
C1.25
B2.Cable
Accessories
C1.Wiring
Duct
C3.Abrasion
Protection
C4.Cable
Management
D1.Terminals
D2.Power
Connectors
E1.LabelingSystems
E2.Labels
E3.Pre-Printed & Write-On
Markers
F.Index
B3.StainlessSteel Ties
C2.Surface
Raceway
E5.Lockout/Tagout
& SafetySolutions
B1.Cable Ties
A.System
Overview
D3.GroundingConnectors
E4.Permanent
Identification
WIRING DUCT TOOLS AND ACCESSORIESPanduit offers a selection of Panduct ® Tools and Accessories to aid cutting, modifying, and installingwiring duct.
• Wide selection of hand tools for cutting and installingwiring duct
• Snap-in wire retainers to retain cabling when the cover isremoved or during cable installation
• Divider walls that mount within the duct, enablingmultiple channels to be created within a duct channel
• Corner strips hold corners rigid at t-junctions in controlpanel applications
• Mounting clips provide an alternative method to mountthe duct and allow the duct to be more easily removed
Some of the features and benefits found in Panduct ®
Tools and Accessories include:
Courtesy of Steven Engineering, Inc. - (800) 258-9200 - [email protected] - www.stevenengineering.com
ELECTRICAL SOLUTIONS
C1.26
Panduct ® Type FL Flexible Wiring Duct
• Material: Flexible Polypropylene
• UL Recognized continuous use temperature: 149°F (65°C)
• UL 94 flammability rating of V-2
• Factory applied adhesive tape provided for easy positioning**
Available in LG (RAL 7040 Light Gray) color only. Unit of measure is pieces.*“H” dimension includes duct and cover.**Adhesive tape is not meant for permanent mounting of wiring duct. One mounting hole on each end will beexposed for permanent mounting with fasteners. For best results, wiring duct should be applied to clean, dry,grease-free surfaces. We recommend the surface be cleaned prior to wiring duct installation.
Part NumberDuct Size (W x H)* Length
Std.Pkg.Qty.In. mm In. mm
FL12X12LG-A .49 x .49 12.5 x 12.5 19.7 500 112
FL25X25LG-A .98 x .98 25.0 x 25.0 19.7 500 70
FL50X50LG-A 1.97 x 1.97 50.0 x 50.0 19.7 500 32
W
H
.25 TYP [6.2]
.20 TYP [5.0]
Panduct ® Divider Wall• Wiring duct divider wall can be mounted inside any type of
Panduit PVC wiring duct to create multiple channels
• Simply install the divider wall base when mounting the duct and snap the divider wall onto the mounting base
• All versions snap onto DB-C mounting base
• Divider wall heights 2" and greater have a scoreline featureallowing sections to be removed leaving a smooth edge
• Meets UL508/508A insulation material requirement for barrierbetween conductors
• UL 94 flammability rating of V-0
• Material: Lead-free PVC
Note: Must be used with mounting base, DB-C (see page C1.26) which is sold separately. Install mounting basesto the duct channel, locate within 2" of each divider wall end and at least every 12" along the length.
D*H6 and D*H2
SD*H6
DB-C
Order number of pieces required, in multiples of Standard Package Quantity.
• Simply install the divider wall base when mounting the duct and snap the divider wall onto mounting base, DB-C
Available in WH (White) color only.NOTE: Must be used with mounting base DB-C (see page C1.26), which is sold separately. Install mounting basesto the duct channel, locate within 2" of each divider wall end and at least every 12" along the length.
Part Number
For Nominal Duct HeightStd.Pkg.Qty.
Std.Ctn.Qty.In. mm
NNC50DWH2 2.00 50 2 40
NNC75DWH2 3.00 75 2 40
Courtesy of Steven Engineering, Inc. - (800) 258-9200 - [email protected] - www.stevenengineering.com
ELECTRICAL SOLUTIONS
Order number of pieces required, in multiples of Standard Package Quantity.C1.28
Panduct ® Type G and H Wiring Duct Wire Retainers• Insert between fingers of type G and H to contain wiring when
cover is removed• Adjustable height
• Material: ABS
*For 2" width type H hinged cover wiring duct use part number WR2H-C.
Panduct ® Solid Wall Raceway Type FS and Type D Wiring Duct Wire Retainer
• Mounts onto walls of type FS raceway or type D duct with pressuresensitive adhesive
• One size fits three different duct widths
• Full length is used with 2 inch wide duct; for small widths, break offsegments at scorelines
• Material: Lead-free PVC
Full length is used with 2" wide duct. For smaller widths, break off segments at scorelines.
WR5-C Use with: 3x5, 4x5, or 6x4 Use with: 3x5, 4x5, or 6x4 100 1000
Courtesy of Steven Engineering, Inc. - (800) 258-9200 - [email protected] - www.stevenengineering.com
ELECTRICAL SOLUTIONS
C1.29
Panduct ® Type F, HN and MC Duct Wire Retainers/Labeling Device
• Used to contain wiring when cover is removed and can also beused as a labeling device
• FWR-C is compatible with type F and HN duct sizes
• FMWR-C is compatible with type MC duct sizes
• Material: Lead-free PVC
Labeling Inside Duct –Snaps onto duct fingers. Fulllength for use with 4" wideduct. For smaller widths, breakoff segments at scorelines.
Labeling Outside Duct –Break off the last segment from wire retainer below1.5" mark and snap onto the back of the remainingsegment. Install label and mount between fingersfacing outward.
Panduct ® Duct Corner Strip with 1" Bend Radius Control
• Create a strong rigid corner at wiring duct junctions
• Provide bend radius protection for cabling as required in NFPA 79-2007 section 13.1.5.9 and TIA/EIA-568-B and 569-A
• Available in 6 foot lengths that can be cut to size to meet any size requirement
• Easy to install two-piece design
• Compatible with all styles of Panduit wiring duct
• UL 94 flammability rating of V-0
• Material: Lead-free PVC
Order number of feet required, in multiples of 6' or Standard Package Quantity.*Refer to Cutting Guide on page C1.30.
For technical assistance in the U.S., call 866-405-6654 (outside the U.S., see inside back cover for directory)
Nylon RivetsNR1-C Nylon rivet for use with TNR rivet tool.
Mean pull-off force PVC: 90 lbs. Type NE/Type NNC: 70 lbs.Mean shear force: PVC 139 lbs. Type NE/Type NNC: 126 lbs.
100
NR1-M Nylon rivet for use with TNR rivet tool.Mean pull-off force PVC: 90 lbs. Type NE/Type NNC: 70 lbs.Mean shear force: PVC 139 lbs. Type NE/Type NNC: 126 lbs.
1000
Courtesy of Steven Engineering, Inc. - (800) 258-9200 - [email protected] - www.stevenengineering.com
For technical assistance in the U.S., call 866-405-6654 (outside the U.S., see inside back cover for directory)
Sidewall: SD2EMI shown.SD3EMI, SD4EMI sidewall feature two pairs of cable tie slots per section.
Bottom view. Bonding clip (for use withwiring duct).
All dimension shown in inches (mm).
Part No. XSD2EMI 1.82 (46.1)
SD3EMI 2.88 (73.2)
SD4EMI 3.86 (98.2)
Dimensions are shown for reference only. Contact Panduit Customer Service at 800-777-3300 for specific dimensional needs.
Dimensions are shown for reference only. Contact Panduit Customer Service at 800-777-3300 for specific dimensional needs.
Courtesy of Steven Engineering, Inc. - (800) 258-9200 - [email protected] - www.stevenengineering.com
ELECTRIC AL SOLUTIONS
C1.36
B2.Cable
Accessories
C1.Wiring
Duct
C3.Abrasion
Protection
C4.Cable
Management
D1.Terminals
D2.Power
Connectors
E1.LabelingSystems
E2.Labels
E3.Pre-Printed & Write-On
Markers
F.Index
B3.StainlessSteel Ties
C2.Surface
Raceway
E5.Lockout/Tagout
& SafetySolutions
B1.Cable Ties
A.System
Overview
D3.GroundingConnectors
E4.Permanent
Identification
For 2" duct height = 3 rows of holes3" duct height = 4 rows of holes4" duct height = 6 rows of holes
>Available for type G wiring duct only.See page C1.13 and C1.17 for wiring duct color and size availability.
Mounting Hole DimensionsFor .5", .75", 1", and 1.5" wide duct.
For 2.0", 2.5", 3", 4" and 6" wide duct.
.50 TYP[12.7]
.20 TYP[5.0]
4.0 [101.6] TYP
4.0 [101.6] TYP
2.0 [50.8]
2.0 [50.8]
KCL
CL
K
>
>
>
>
>
>
>
>
>
>
>
>
>
>
>
>
>
>
>
Panduct ® Type G and D Wiring Duct DimensionsDimensions are shown for reference only. Contact Panduit Customer Service at 800-777-3300 for specific dimensional needs.
Note: ‘A’ dimension is measured at base.Note: ‘K’ dimension shown in mounting holedimensions below.
Courtesy of Steven Engineering, Inc. - (800) 258-9200 - [email protected] - www.stevenengineering.com
For technical assistance in the U.S., call 866-405-6654 (outside the U.S., see inside back cover for directory)
ELECTRIC AL SOLUTIONS
C1.37
B2.Cable
Accessories
C1.Wiring
Duct
C3.Abrasion
Protection
C4.Cable
Management
D1.Terminals
D2.Power
Connectors
E1.LabelingSystems
E2.Labels
E3.Pre-Printed & Write-On
Markers
F.Index
B3.StainlessSteel Ties
C2.Surface
Raceway
E5.Lockout/Tagout
& SafetySolutions
B1.Cable Ties
A.System
Overview
D3.GroundingConnectors
E4.Permanent
Identification
Panduct ® Type F Wiring Duct and FS Raceway DimensionsDimensions are shown for reference only. Contact Panduit Customer Service at 800-777-3300 for specific dimensional needs.
Note: ‘A’ dimension is measured at base.Note: ‘K’ dimension shown in mounting hole dimensions below.
Note: For type FS raceway, no mountingholes is the standard condition; if mountingholes are required, delete NM from thepart number.
>Available for type FS raceway only.See page C1.48 for wiring duct color and size availability.
For .5", .75", 1" and 1.5" high duct.
For 2", 3", 4" and 5" high duct.
D
T
A
B H
EC
T
A
B H
EC
F
D
F
Mounting Hole DimensionsFor .5", .75", 1" and 1.5" wide duct.
Courtesy of Steven Engineering, Inc. - (800) 258-9200 - [email protected] - www.stevenengineering.com
ELECTRIC AL SOLUTIONS
C1.38
B2.Cable
Accessories
C1.Wiring
Duct
C3.Abrasion
Protection
C4.Cable
Management
D1.Terminals
D2.Power
Connectors
E1.LabelingSystems
E2.Labels
E3.Pre-Printed & Write-On
Markers
F.Index
B3.StainlessSteel Ties
C2.Surface
Raceway
E5.Lockout/Tagout
& SafetySolutions
B1.Cable Ties
A.System
Overview
D3.GroundingConnectors
E4.Permanent
Identification
Mounting Hole DimensionsFor 25mm, 37.5mm, and 50mm width duct.
For 75mm and 100mm width duct.
2000 mm[78.74]
1950 mm[76.77]
1950 mm[76.77]
14 mm[0.55]
50 mm[1.97]
25 mm[.98] 12.5 mm
[.49]6.5 mm
[.26]
4.5 mm[.18]
25 mm[.98]
8 mm[0.32]
2000 mm[78.74]
Panduct ® Type MC Wiring Duct DimensionsDimensions are shown for reference only. Contact Panduit Customer Service at 800-777-3300 for specific dimensional needs.
Note: ‘A’ dimension is measured at base.Note: ‘K’ dimension shown in mounting hole dimensions below.
Courtesy of Steven Engineering, Inc. - (800) 258-9200 - [email protected] - www.stevenengineering.com
For technical assistance in the U.S., call 866-405-6654 (outside the U.S., see inside back cover for directory)
ELECTRIC AL SOLUTIONS
C1.39
B2.Cable
Accessories
C1.Wiring
Duct
C3.Abrasion
Protection
C4.Cable
Management
D1.Terminals
D2.Power
Connectors
E1.LabelingSystems
E2.Labels
E3.Pre-Printed & Write-On
Markers
F.Index
B3.StainlessSteel Ties
C2.Surface
Raceway
E5.Lockout/Tagout
& SafetySolutions
B1.Cable Ties
A.System
Overview
D3.GroundingConnectors
E4.Permanent
Identification
Panduct ® Type NNC Wiring Duct DimensionsDimensions are shown for reference only. Contact Panduit Customer Service at 800-777-3300 for specific dimensional needs.
For 25mm, 37.5mm, and 50mm high duct.
For 75mm and 100mm high duct.
D
T
A
B H
C
T
A
B H
C
10.0 TYP[.39]
25.0 TYP[.98]
10.0 TYP[.39]
25.0 TYP[.98]
D
Mounting Hole DimensionsFor 25mm, 37.5mm, and 50mm width duct.
For 75mm and 100mm width duct.
2000 mm[78.74]
1950 mm[76.77]
1950 mm[76.77]
14 mm[0.55]
50 mm[1.97]
25 mm[.98] 12.5 mm
[.49]6.5 mm
[.26]
4.5 mm[.18]
25 mm[.98]
8 mm[0.32]
2000 mm[78.74]
Duct Size(W x H)
Dimensions – mm (Inches)A B C D H T
25 x 25 24.6 23.6 24.6 13.6 20.3 1.5
(.98) x (.98) (.97) (.93) (.97) (.54) (.80) (.06)
25 x 37 24.6 35.8 24.6 24.6 33.0 1.8
(.98) x (1.48) (.97) (1.41) (.97) (.97) (1.30) (.07)
25 x 50 24.6 47.8 24.6 34.8 45.5 2.0
(.98) x (1.97) (.97) (1.88) (.97) (1.37) (1.79) (.08)
25 x 75 24.6 72.4 24.6 57.6 70.6 2.0
(.98) x (2.95) (.97) (2.85) (.97) (2.27) (2.78) (.08)
37.5 x 37.5 37.1 35.8 37.1 24.7 33.0 1.8
(1.48) x (1.48) (1.46) (1.41) (1.46) (.97) (1.30) (.07)
37.5 x 50 37.1 47.8 37.1 34.8 45.5 2.0
(1.48) x (1.97) (1.46) (1.88) (1.46) (1.37) (1.79) (.08)
37.5 x 75 37.1 72.4 37.1 57.6 70.6 2.0
(1.48) x (2.95) (1.46) (2.85) (1.46) (2.27) (2.78) (.08)
50 x 50 49.5 47.8 49.5 34.8 45.5 2.0
(1.97) x (1.97) (1.95) (1.88) (1.95) (1.37) (1.79) (.08)
50 x 75 49.5 72.4 49.5 57.6 70.6 2.0
(1.97) x (2.95) (1.95) (2.85) (1.95) (2.27) (2.78) (.08)
50 x 100 49.5 97.8 49.5 81.0 95.5 2.3
(1.97) x (3.94) (1.95) (3.85) (1.95) (3.19) (3.76) (.09)
75 x 75 74.7 72.4 74.7 57.6 70.6 2.0
(2.95) x (2.95) (2.94) (2.85) (2.94) (2.27) (2.78) (.08)
100 x 50 99.6 47.8 99.6 34.8 45.5 2.0
(3.94) x (1.97) (3.92) (1.88) (3.92) (1.37) (1.79) (.08)
100 x 75 99.6 72.4 99.6 57.6 70.6 2.0
(3.94) x (2.95) (3.92) (2.85) (3.92) (2.27) (2.78) (.08)
100 x 100 99.6 97.8 99.6 81.0 95.5 2.3
(3.92) x (3.85) (3.92) (3.85) (3.92) (3.19) (3.76) (.09)
Courtesy of Steven Engineering, Inc. - (800) 258-9200 - [email protected] - www.stevenengineering.com
ELECTRIC AL SOLUTIONS
C1.40
B2.Cable
Accessories
C1.Wiring
Duct
C3.Abrasion
Protection
C4.Cable
Management
D1.Terminals
D2.Power
Connectors
E1.LabelingSystems
E2.Labels
E3.Pre-Printed & Write-On
Markers
F.Index
B3.StainlessSteel Ties
C2.Surface
Raceway
E5.Lockout/Tagout
& SafetySolutions
B1.Cable Ties
A.System
Overview
D3.GroundingConnectors
E4.Permanent
Identification
Panduct ® Type NE Wiring Duct DimensionsDimensions are shown for reference only. Contact Panduit Customer Service at 800-777-3300 for specific dimensional needs.
For .5" high duct.
For 1", 1.5", 2", 3", 4" and 5" high duct.
D
T
A
BH
E
C
T
A
BH
E
C
F
D
F
Mounting Hole DimensionsFor .5", .75", 1" and 1.5" wide duct.
Courtesy of Steven Engineering, Inc. - (800) 258-9200 - [email protected] - www.stevenengineering.com
For technical assistance in the U.S., call 866-405-6654 (outside the U.S., see inside back cover for directory)
ELECTRIC AL SOLUTIONS
C1.41
B2.Cable
Accessories
C1.Wiring
Duct
C3.Abrasion
Protection
C4.Cable
Management
D1.Terminals
D2.Power
Connectors
E1.LabelingSystems
E2.Labels
E3.Pre-Printed & Write-On
Markers
F.Index
B3.StainlessSteel Ties
C2.Surface
Raceway
E5.Lockout/Tagout
& SafetySolutions
B1.Cable Ties
A.System
Overview
D3.GroundingConnectors
E4.Permanent
Identification
Panduct ® Type H and HS Wiring Duct DimensionsDimensions are shown for reference only. Contact Panduit Customer Service at 800-777-3300 for specific dimensional needs.
Panduct ® Type HN Wiring Duct DimensionsDimensions are shown for reference only. Contact Panduit Customer Service at 800-777-3300 for specific dimensional needs.
D
T
A
B
H
E
C
100°
F
For 2" duct height: .31" [7.9] .80" [20.3] 3" to 4" duct height: .31" [7.9] 1.00" [25.4]
FE
For 2", 3", and 4" wide duct.
4.0 [101.6] TYP 2.0 [50.8]
KCL
K
For 2", 3", and 4" wide duct.
2.0 [50.8]
2.0 TYP [50.8]
KCL
K
D
B
H
E
F
T
A
C
100°
Multiple slot restrictors present with2" and greater duct wall height.
Courtesy of Steven Engineering, Inc. - (800) 258-9200 - [email protected] - www.stevenengineering.com
ELECTRIC AL SOLUTIONS
C1.42
Mounting Hole DimensionsFor FL12X12LG-A
For FL25X25LG-A and FL50X50LG-A
A
A
B
5.0 TYP[.20] 8.0 TYP
[.31]
6.2 TYP[.25]
4.0 TYP[.16]
25.0 TYP[.98]
25.0 TYP[.98]
12.5[.49]
12.5[.49]
12.5 TYP[.49]
CL
CL
Dimensions are shown for reference only.Dimensions are in mm (in.). Contact Panduit Customer Service at 800-777-3300 for specific dimensional needs.
Panduct ® Type FL Wiring Duct Dimensions
Note: Type FL wiring duct has factory appliedadhesive. For 50 x 50 two strips of tape are used;otherwise, only one strip is centered on the part.
Note: ‘B’ dimension is without adhesive.
Nominal Duct Size(W x H)
mm
Dimensions – mm (In.)
A B12 x 12
(.49) x (.49)12.4(.49)
12.4(.49)
25 x 25(.98) x (.98)
24.9(.98)
24.9(.98)
50 x 50(1.97) x (1.97)
50(1.97)
50(1.97)
Table shows maximum wirefill based on 50% of duct internal cross sectional area. Formula = area/2.00 x D2.
Table shows maximum wirefill based on 50% of duct internal cross sectional area. Formula = nominal area/1.85 x D2. See page C1.48 for wiring duct color and size availability. AWG dimensions represent typical outer cable diameter in inches.
Courtesy of Steven Engineering, Inc. - (800) 258-9200 - [email protected] - www.stevenengineering.com
ELECTRIC AL SOLUTIONS
C1.43
Panduct ® Type D, G, F and FS Wiring Duct – Wirefill Capacity
Table shows maximum wirefill based on 50% of duct internal cross sectional area. Formula = nominal area/1.75 x D2. See page C1.48 for wiring duct color and size availability. Not all sizes available for each duct type.AWG dimensions represent typical outer cable diameter in inches.
For technical assistance in the U.S., call 866-405-6654 (outside the U.S., see inside back cover for directory)
Courtesy of Steven Engineering, Inc. - (800) 258-9200 - [email protected] - www.stevenengineering.com
ELECTRIC AL SOLUTIONS
C1.44
B2.Cable
Accessories
C1.Wiring
Duct
C3.Abrasion
Protection
C4.Cable
Management
D1.Terminals
D2.Power
Connectors
E1.LabelingSystems
E2.Labels
E3.Pre-Printed & Write-On
Markers
F.Index
B3.StainlessSteel Ties
C2.Surface
Raceway
E5.Lockout/Tagout
& SafetySolutions
B1.Cable Ties
A.System
Overview
D3.GroundingConnectors
E4.Permanent
Identification
Panduct ® Type MC and NNC Wiring Duct – Wirefill Capacity
Table shows maximum wirefill based on 50% of duct internal cross sectional area. Formula = nominal area/1.75 x D2. See page C1.48 for wiring duct colorand size availability. Not all sizes available for each duct type.AWG dimensions represent typical outer cable diameter in millimeters.
Courtesy of Steven Engineering, Inc. - (800) 258-9200 - [email protected] - www.stevenengineering.com
For technical assistance in the U.S., call 866-405-6654 (outside the U.S., see inside back cover for directory)
ELECTRIC AL SOLUTIONS
C1.45
B2.Cable
Accessories
C1.Wiring
Duct
C3.Abrasion
Protection
C4.Cable
Management
D1.Terminals
D2.Power
Connectors
E1.LabelingSystems
E2.Labels
E3.Pre-Printed & Write-On
Markers
F.Index
B3.StainlessSteel Ties
C2.Surface
Raceway
E5.Lockout/Tagout
& SafetySolutions
B1.Cable Ties
A.System
Overview
D3.GroundingConnectors
E4.Permanent
Identification
Panduct ® Type NE Wiring Duct – Wirefill Capacity
Panduct ® Type FL Wiring Duct – Wirefill Capacity
Table shows maximum wirefill based on 50% of duct internal cross sectional area. Formula = nominal area/2.00 x D2.AWG dimensions represent typical outer cable diameter in inches.
Table shows maximum wirefill based on 50% of duct internal cross sectional area. Formula = nominal area/2.50 x D2.AWG dimensions represent typical outer cable diameter in millimeters.
Courtesy of Steven Engineering, Inc. - (800) 258-9200 - [email protected] - www.stevenengineering.com
ELECTRIC AL SOLUTIONS
C1.46
B2.Cable
Accessories
C1.Wiring
Duct
C3.Abrasion
Protection
C4.Cable
Management
D1.Terminals
D2.Power
Connectors
E1.LabelingSystems
E2.Labels
E3.Pre-Printed & Write-On
Markers
F.Index
B3.StainlessSteel Ties
C2.Surface
Raceway
E5.Lockout/Tagout
& SafetySolutions
B1.Cable Ties
A.System
Overview
D3.GroundingConnectors
E4.Permanent
Identification
Wirefill Formula
General FormulaPanduit Wiring Duct wirefills are calculated using the following general formula:
Why use a 50% Wirefill?As specified in NFPA79-2007 section 13.5.2, Percentage Fills of Raceways (Ducts), a 50% wirefill is given asthe maximum wirefill capacity in all Panduit Wiring Ducts. This helps ensure general safe wiring practicesare followed. In actual practice, a 50% wirefill is the maximum amount of wiring the duct can hold given theadditional airspace created between cables by non-uniform cable shapes, cable interlacing, and cablepacking factors.
Since we use the outerchannel dimensions inour calculation, wemake an adjustment inour formula for thethickness of materialand for design elementsthat extend insidethe channel.
In our wirefill formula anadjustment is made to thechannel internal area toaccount for “unusable” airspace that will be presentbetween cables when placedin the channel. Our formulaassumes a uniform closepacked or high-density cable arrangement (see diagram) (Note 1).
What is the Usable Duct Area?The usable area we define as the calculation of internal area that can be occupied by wires or cables.
Wire AreaThe wire area formula is converted to allow calculation using the cable diameter:
Formula DerivationInserting the elements from above into thegeneral formula results in the following:
Note: When calculating wirefill capacity using the above formula, variables W, H, and D must be expressed insame units (i.e. mm or inches).
1 This calculation does not account for additional airspace created between cables by non-uniform cable shapes, cable interlacing, and cable packing factors.2 The resulting formula is used for all Panduit flush cover ducts, this excludes type NE duct which has a different profile design that results in a
divisor of 2.0 x D 2 (rather than 1.75 x D 2 as shown here) and type H and HS wiring duct with a profile design that results in a divisor of 1.85 x D 2 andcorner wiring duct which uses calculated internal area and a divisor of 2.0 x D 2.
Simplifying this formula results in the formulaused for wirefill calculation (Note 2):
Considering these factors, the usable duct area is equal to an average of 90% of the nominal area, or (W x H) x .90.
Calculation of Internal Area Air Space Allotment
Courtesy of Steven Engineering, Inc. - (800) 258-9200 - [email protected] - www.stevenengineering.com
For technical assistance in the U.S., call 866-405-6654 (outside the U.S., see inside back cover for directory)
ELECTRIC AL SOLUTIONS
C1.47
B2.Cable
Accessories
C1.Wiring
Duct
C3.Abrasion
Protection
C4.Cable
Management
D1.Terminals
D2.Power
Connectors
E1.LabelingSystems
E2.Labels
E3.Pre-Printed & Write-On
Markers
F.Index
B3.StainlessSteel Ties
C2.Surface
Raceway
E5.Lockout/Tagout
& SafetySolutions
B1.Cable Ties
A.System
Overview
D3.GroundingConnectors
E4.Permanent
Identification
Panduct ® Wiring Duct and Raceway – Material Specifications
Note: To the best of our knowledge the above information is accurate.Panduit assumes no liability for the accuracy or completeness of this information.
Rigid Polyvinyl Chloride(PVC)A general purpose material for use in indoor applications. PVC has a UL 94 flammability rating of V-0 and is UL Recognized for continuoususe temperatures up to 122°F (50°C).PVC is an economical wiring duct material.
Halogen-Free (Modified Polyphenylene Oxide)A special purposematerial for use in halogen-free or high temperature applications.Modified PPO has a UL 94 flammability rating of V-0 and is UL Recognized forcontinuous use temperatures up to 203°F(95°C), and is 20% lighter than PVC.
PolypropyleneA flexible material with a UL 94flammability rating of V-2 and ULRecognized for continuous usetemperatures up to 149°F (65°C).
Properties Units Test MethodLead-Free
PVC
Halogen-FreeModified PPO
(NNC, NE)Polypropylene
(FL)
GeneralSpecific gravity g/cc ASTM D 792 1.45 1.09 0.95Heat deflection temperature @264 psi °F ASTM D 648 156 215 117Thermal expansion 10-5 in/in/°F ASTM D 696 3.7 3.8 N/A
Thermal conductivity (BTU-in/hr-ft²)°F ASTM C 177 1.3 1.3 N/A
Burning CharacteristicsFlammability class — UL 94 V-0 V-0 V-2Smoke density @ 4 minutes — ASTM E 662 538 513 N/ALimited oxygen index (LOI) — ASTM D 2863 35 30 25Peak heat release rate kW/m2 ASTM E 1354 N/A N/A N/A
HardnessDurometer hardness "D" ASTM D 2240 78 N/A N/ARockwell hardness "R" ASTM D 785 111 116 N/A
TensileYield Strength psi ASTM D 638 6,200 7,700 3,770Modulus psi ASTM D 638 390,000 350,000 172,000
FlexuralYield Strength psi ASTM D 790 8,700 11,500 4,350Modulus psi ASTM D 790 325,000 340,000 181,250
Courtesy of Steven Engineering, Inc. - (800) 258-9200 - [email protected] - www.stevenengineering.com
ELECTRIC AL SOLUTIONS
C1.48
B2.Cable
Accessories
C1.Wiring
Duct
C3.Abrasion
Protection
C4.Cable
Management
D1.Terminals
D2.Power
Connectors
E1.LabelingSystems
E2.Labels
E3.Pre-Printed & Write-On
Markers
F.Index
B3.StainlessSteel Ties
C2.Surface
Raceway
E5.Lockout/Tagout
& SafetySolutions
B1.Cable Ties
A.System
Overview
D3.GroundingConnectors
E4.Permanent
Identification
Panduct ® Wiring Duct and Raceway – Color and Size Selection
*Intrinsic Blue Color – IB
Intrinsic blue wiring duct is made from the same lead-free PVC material as our standard PVC duct. Intrinsic blue is an internationallyrecognized standard blue color that identifies the wiring duct as “incapable of releasing sufficient electrical or thermal energy under normalor abnormal conditions to cause ignition of a specific hazardous atmospheric mixture in its most easily ignited concentrations.”
*ISA-RD12.6 (Instrument Society of America)
*Corner Duct Profile**DIN Rail Duct Profile
Duct SizeW x H
LGLight Gray
WHWhite
BLBlack
IBIntrs.Blue*
IGIntl.Gry.In. mm
.5 x .5 12 x 12 G F FS FL G F FS NE.5 x 1 G F FS G F NE.5 x 2 G G
.75 x .75 G F FS G F.75 x 1 G G
.75 x 1.5 G F G F.75 x 2 G G G1 x 1 25 x 25 G F FS NNC FL G F FS NE NNC MC G FS G F MC
1 x 1.5 25 x 37 G F FS NNC G F NE NNC MC G G F MC1 x 2 25 x 50 G F FS D NNC G F NE NNC MC G D G F MC
1 x 2.5 25 x 62 MC MC1 x 3 25 x 75 G F FS D NNC G F D NE NNC MC G D G F MC1 x 4 25 x 100 G F FS D G F D NE G D G F
1.5 x 1 G F FS G F FS1.5 x 1.5 37 x 37 G F FS NNC G F FS NE NNC MC G FS G F MC1.5 x 2 37 x 50 G F FS D H HN HS NNC G F NE H HN HS NNC MC G D H HS G F MC
1.5 x 2.5 37 x 62 MC MC1.5 x 3 37 x 75 G F FS D H HN HS NNC G F D NE H HN HS NNC MC G D H HS G F MC1.5 x 4 G F D G F D NE G D G F2 x 1 G F FS G F FS NE G
2 x 1.5 G F FS G F FS2 x 2 50 x 50 G F FS D H HN HS NNC FL G F FS D NE H HN HS NNC MC G FS D H HS G F MC2 x 3 50 x 75 G F FS D H HN HS NNC G F FS D NE H HN HS NNC MC G D H HS G F MC2 x 4 50 x 100 G F FS D H HN HS NNC G F D NE H HN HS NNC MC G D H HS G F MC2 x 5 G F G F
2.5 x 2.5 62 x 62 MC MC2.5 x 3 G F D G F G3 x 1 G F FS G F FS NE3 x 2 75 x 50 G F FS D G F FS NE MC G FS MC
3 x 2.5 75 x 62 MC MC3 x 3 75 x 75 G F FS D H HN HS NNC G F FS D NE H HN HS NNC MC G FS D H HS G F MC3 x 4 75 x 100 G F FS D H HN HS G F FS D NE H HN HS MC G D H HS G F MC3 x 5 G F FS G F FS NE
4 x 1.5 G FS G4 x 2 100 x 50 G F FS D NNC G F FS NE NNC MC G D MC4 x 3 100 x 75 G F FS D NNC G F FS NE NNC MC G G F MC4 x 4 100 x
100G F FS D H HN HS NNC G F FS D NE H HN HS NNC MC G FS D H HS G F MC
4 x 5 G F FS G F NE G6 x 4 G F FS G F FS4.40 x3.57*
111.8 x90.7
CWD CWD
5.33 x4.58*
135.3 x115.7
CWD CWD
6.25 x2.12**
156.7 x54.0
DRD DRD
7.25 x3.12**
184.1 x79.4
DRD DRD
8.25 x4.12**
209.5 x104.8
DRD DRD
Courtesy of Steven Engineering, Inc. - (800) 258-9200 - [email protected] - www.stevenengineering.com
For technical assistance in the U.S., call 866-405-6654 (outside the U.S., see inside back cover for directory)
ELECTRIC AL SOLUTIONS
C1.49
B2.Cable
Accessories
C1.Wiring
Duct
C3.Abrasion
Protection
C4.Cable
Management
D1.Terminals
D2.Power
Connectors
E1.LabelingSystems
E2.Labels
E3.Pre-Printed & Write-On
Markers
F.Index
B3.StainlessSteel Ties
C2.Surface
Raceway
E5.Lockout/Tagout
& SafetySolutions
B1.Cable Ties
A.System
Overview
D3.GroundingConnectors
E4.Permanent
Identification
Installation Tips:Application of Latex Paint on Panduct ® Wiring Duct
Cutting Wiring Duct and Cover
Recommended Precaution when Using Type NNC and NE Wiring Duct
The following is recommended to properly prepare the surface of thewiring duct/raceway and covers for the best adhesion of latex paint:
1. Clean surface with mild soap and water solution or mineral spiritswith a clean lint free towel. Allow to dry.
2. Using a sanding pad (such as synthetic stripping pad or medium/finesteel wool), slightly roughen the surface to be painted.
3. Apply a coat of all-purpose 100% acrylic primer and allow to dry.
4. Apply the desired topcoat of latex paint and allow to dry.
5. Install the wiring duct/raceway and covers.
For small quantities, use the DCT duct cutting tool on page C1.34. For larger quantities use a miter cuttingsaw blade for clean burr-free cuts. Recommended blade: Carbide 80T or 100T; .90" thickness, .125 kerf.
Cleaning solvents and cutting fluids that contain any of the following chemical agents should not come incontact with type NNC or type NE wiring duct. These chemicals are known to cause stress cracking in thehalogen-free PPO material.
• Hydrocarbons
• Phenols
• Ketones
• Amines
• Ethers
• Organic, inorganic and oxidizing acids
• Petrol
Note: Panduit assumes no liability for the accuracy or completeness of this list.
This European standard specifiesdimensions for slotted trunkings that willbe used in electrical switchgearassemblies and that conform to thecorresponding requirements in DIN VDE060 Part 506. The dimensions specifiedwith the standard include:
• The channel mounting hole pattern,slot dimensions, pitch, and location
• The distance from the first to lastlike size mounting hole
• Minimum overall product length
Wiring duct types:MC and NNC
National FireProtection Agency
NFPA 79-2007,section 13.3.1
“Non-metallic ducts shall be permitted(inside enclosures) only when they aremade with a flame retardant material.”Flame-retardant material is defined in thestandard by the IEC 60332-1 test method.
Wiring duct types:H, G, F, D, MC, NNC,
CWD, HN, and NE
NFPA 79-2007,section 13.5.2
Panduit wiring duct publishes a maximumpercentage wirefill for common wire typesequal to 50% of the interiorcross-sectional area of the duct.
All types of wiring duct
NFPA 79-2007,section 13.1.5.9
Panduit bend radius control accessoriescan be mounted at right angle and Tjunctions created using wiring duct in orderto maintain cable bend radius control.
Duct corner strip with 1"bend radius control
Courtesy of Steven Engineering, Inc. - (800) 258-9200 - [email protected] - www.stevenengineering.com
ELECTRIC AL SOLUTIONS
C1.52
B2.Cable
Accessories
C1.Wiring
Duct
C3.Abrasion
Protection
C4.Cable
Management
D1.Terminals
D2.Power
Connectors
E1.LabelingSystems
E2.Labels
E3.Pre-Printed & Write-On
Markers
F.Index
B3.StainlessSteel Ties
C2.Surface
Raceway
E5.Lockout/Tagout
& SafetySolutions
B1.Cable Ties
A.System
Overview
D3.GroundingConnectors
E4.Permanent
Identification
Panduit Wiring Duct Approvals and Compliances (continued)
An insulating barrier material shall complywith the properties indicated in Table 15.1. PVC divider wall
UL 508,sections 34, 181
Shall comply with minimum thicknessas required in section 6.3. SD*EMI metal barrier
Elevated temperature Panduit logo Material is rated for a continuous usetemperature above 167°F (75°C).
Wiring duct types:NNC and NE
Halogen-free IEC 60754-2 Panduit logo
Material contains no fluorine, bromide, orchlorine and will not emit any corrosive ortoxic gases when burned, confirmed usingIEC 60754-2 test method.
Wiring duct types:NNC and NE
Low flammability UL 94V-0 Panduit logo
Per UL standard, material isself-extinguishing and has excellentfire resistance.
Wiring duct types:NNC, NE, and
all PVC wiring duct
Low toxicity Boeingand Airbus BSS-7239,
ATS 1000.1Panduit logo
Per the Boeing and Airbus test standards,material exceeds the requirements for lowlevels of toxic gas release.
Wiring duct type:NNC and NE
Courtesy of Steven Engineering, Inc. - (800) 258-9200 - [email protected] - www.stevenengineering.com
For technical assistance in the U.S., call 866-405-6654 (outside the U.S., see inside back cover for directory)
ELECTRICAL SOLUTIONS
C1.53
B2.Cable
Accessories
C1.Wiring
Duct
C3.Abrasion
Protection
C4.Cable
Management
D1.Terminals
D2.Power
Connectors
E1.LabelingSystems
E2.Labels
E3.Pre-Printed & Write-On
Markers
F.Index
B3.StainlessSteel Ties
C2.Surface
Raceway
E5.Lockout/Tagout
& SafetySolutions
B1.Cable Ties
A.System
Overview
D3.GroundingConnectors
E4.Permanent
Identification
FIBER-DUCT ™ ROUTING SYSTEMPanduit provides leading solutions for cable routing. These routing products are compatible with our
cable management solutions increasing your ability to maintain an orderly and clean work environment,
implement quick and easy moves, adds, and changes and maintain the integrity of your fiber and copper
cabling plant in order to maximize long-term performance.
• Two system sizes available: 2x2 and 4x4
• Minimum 2 inch (50.8mm) bend radius fittingsprotect against signal loss due to excessivecable bends
• Snap-on non-slip covers
• Compatible with Panduit® FiberRunner® 12x4, 6x4,4x4 and 2x2 Routing Systems
The 2x2 and 4x4 Fiber-Duct ™ Routing Systems are comprised of channel, fittings, and brackets designed
to segregate, route, and protect fiber optic and copper cabling to and between racks within the
telecommunications room.
Courtesy of Steven Engineering, Inc. - (800) 258-9200 - [email protected] - www.stevenengineering.com
ELECTRICAL SOLUTIONS
C1.54
B2.Cable
Accessories
C1.Wiring
Duct
C3.Abrasion
Protection
C4.Cable
Management
D1.Terminals
D2.Power
Connectors
E1.LabelingSystems
E2.Labels
E3.Pre-Printed & Write-On
Markers
F.Index
B3.StainlessSteel Ties
C2.Surface
Raceway
E5.Lockout/Tagout
& SafetySolutions
B1.Cable Ties
A.System
Overview
D3.GroundingConnectors
E4.Permanent
Identification
2x2 and 4x4 Fiber-Duct ™ Routing Systems Roadmap
1
2
34
56
9
12
10
11
13
14
8
7
FTRBE12 – Existing Threaded Rod Bracket
(page C1.60)
FTRBN12 – New Threaded
Rod Bracket (page C1.60)
FZBA1.5X4 – Adjustable “Z” Bracket
(page C1.60)
FUSB – Underfloor Pedestal Bracket
(page C1.60)
FLRB – Ladder Rack Bracket (page C1.60)
FLB – “L” Wall Mount Bracket
(page C1.60)
FZBLP – Low Profile “Z” Bracket
(page C1.60)
Fiber-Duct ™ Mounting Brackets
F2PCLB12 – Two-Piece Ladder RackBracket for Attaching Threaded Rod to
1 1/2" – 2" Ladder Rack (page C1.61)
Courtesy of Steven Engineering, Inc. - (800) 258-9200 - [email protected] - www.stevenengineering.com
For technical assistance in the U.S., call 866-405-6654 (outside the U.S., see inside back cover for directory)
ELECTRICAL SOLUTIONS
C1.55
B2.Cable
Accessories
C1.Wiring
Duct
C3.Abrasion
Protection
C4.Cable
Management
D1.Terminals
D2.Power
Connectors
E1.LabelingSystems
E2.Labels
E3.Pre-Printed & Write-On
Markers
F.Index
B3.StainlessSteel Ties
C2.Surface
Raceway
E5.Lockout/Tagout
& SafetySolutions
B1.Cable Ties
A.System
Overview
D3.GroundingConnectors
E4.Permanent
Identification
FCF2X2** and FCF4X4** – Coupler Fitting (see page C1.56)
FEC2X2** and FEC4X4** – End Cap Fitting (see page C1.57)
FFWC2X2** and FFWC4X4** – 4-Way Cross Fitting (see page C1.57)
FIVRA2X2** and FIVRA4X4** – Inside Vertical Right Angle (see page C1.57)
FIV452X2** and FIV454X4** – Inside Vertical 45° Angle (see page C1.57)
FOV452X2** and FOV454X4** – Outside Vertical 45° Angle (see page C1.57)
FT2X2** and FT4X4** – Horizontal Tee Fitting (see page C1.57)
FVT4X4** – 4x4 Vertical Tee (see page C1.58)
FRA2X2** – FRA4X4** – Right Angle Fitting (see page C1.56)
FRF42** – 4x4 to 2x2 Fiber-Duct ™ Reducer Fitting (see page C1.57)
S2X2**6NM and S4X4**6NM Fiber-Duct ™ Channel (see page C1.56)
E2X2**6 and E4X4**6 Fiber-Duct ™ Slotted Channel (see page C1.56)
FOVRA2X2** and FOVRA4X4** – Outside Vertical Right Angle (see page C1.57)
TRC2BL and TRC4BL – Bend Radius Control Trumpet (see page C1.59)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
**Available colors include: YL (Yellow), OR (Orange), and BL (Black).
Courtesy of Steven Engineering, Inc. - (800) 258-9200 - [email protected] - www.stevenengineering.com
ELECTRICAL SOLUTIONS
C1.56
B2.Cable
Accessories
C1.Wiring
Duct
C3.Abrasion
Protection
C4.Cable
Management
D1.Terminals
D2.Power
Connectors
E1.LabelingSystems
E2.Labels
E3.Pre-Printed & Write-On
Markers
F.Index
B3.StainlessSteel Ties
C2.Surface
Raceway
E5.Lockout/Tagout
& SafetySolutions
B1.Cable Ties
A.System
Overview
D3.GroundingConnectors
E4.Permanent
Identification
2x2 and 4x4 Fiber-Duct ™ Routing Systems
• Channel, covers, fittings and other non-metallic systemcomponents made from V-0 flame class rated material
• Snap-on non-slip covers
• Compatible with Panduit® FiberRunner® 2x2, 4x4, 6x4 and 12x4 Routing Systems
Note: Available with mounting holes. To order, delete NM from the part number.For fastest installation use NR2WH-L or NR4BL-L snap rivets.For other colors replace YL (Yellow) with OR (Orange) or BL (Black).Order number of feet required, in multiples of standard 6' length increments.
C2C4
S2X2S4X4
E2X2E4X4
FCF2X2FCF4X4
FRA2X2FRA4X4
Fiber-Duct ™ System Fittings
For other colors replace suffix YL (Yellow) with OR (Orange) or BL (Black).Fittings include 5/16" assembly holes for fast mechanical fastening.
Part Number Part DescriptionSystem
Size
Std.Pkg.Qty.
Std.Ctn.Qty.
Fiber-Duct ™ ChannelS2X2YL6NM Used to carry the cables throughout the
Fiber-Duct ™ Routing System. Accepts cover C2YL6.Cover sold separately.
2x2 6 120
S4X4YL6NM Used to carry the cables throughout the Fiber-Duct ™ Routing System. Accepts cover C4YL6.Cover sold separately.
4x4 6 60
Fiber-Duct ™ Slotted ChannelE2X2YL6 Used to carry the cables vertically to the front or
the back of equipment racks throughout the system.Accepts cover C2YL6. Extra supports required when used in horizontal applications.Cover sold separately.
2x2 6 120
E4X4YL6 Used to carry the cables vertically to the front or the back of equipment racks throughout the system.Accepts cover C4YL6. Extra supports required when used in horizontal applications.Cover sold separately.
4x4 6 60
Fiber-Duct ™ CoverC2YL6 Cover for Fiber-Duct ™ Channel and Fiber-Duct ™
Slotted Channel. Non-slip cover design incorporatesintegral high friction lining to inhibit cover movement.
2x2 6 120
C4YL6 Cover for Fiber-Duct ™ Channel and Fiber-Duct ™
Slotted Channel. Non-slip cover design incorporatesintegral high friction lining to inhibit cover movement.
4x4 6 120
Part Number Part DescriptionSystem
Size
Std.Pkg.Qty.
Std.Ctn.Qty.
Coupler FittingFCF2X2YL Used to join two sections of duct together.
Fiber-Duct ™ Coupler is not required at each fitting connection.
2x2 1 5
FCF4X4YL 4x4 1 5
Horizontal Right Angle FittingFRA2X2YL Attaches to channel to create a 90° horizontal turn
from a straight horizontal run. Cover included.2x2 1 5
FRA4X4YL 4x4 1 5
Order number of pieces required, in multiples of Standard Package Quantity. Prime items appear in BOLD.
Courtesy of Steven Engineering, Inc. - (800) 258-9200 - [email protected] - www.stevenengineering.com
Std.Ctn.Qty.
Std.Pkg.Qty.
SystemSizePart DescriptionPart Number
Horizontal Tee FittingFT2X2YL Attaches to channel to create a 90° horizontal
branch from a straight horizontal run.Cover included.
2x2 1 5
FT4X4YL 4x4 1 5
Four Way Cross FittingFFWC2X2YL Attaches to channel to create a horizontal four
way cross intersection. Cover included.2x2 1 5
FFWC4X4YL 4x4 1 5
End Cap Fitting
FEC4X4YL 4x4 1 5
Inside Vertical 45° Angle FittingFIV452X2YL Attaches to channel to create a 45° upward angle
from a straight horizontal run. Used with outsidevertical 45° angle fitting FOV452X2YL orFOV454X4YL to change level of straight horizontal runs. Cover included.
2x2 1 5
FIV454X4YL 4x4 1 5
Outside Vertical 45° Angle FittingFOV452X2YL Attaches to channel to create a 45° downward
angle from a straight horizontal run. Used withinside vertical 45° angle fitting FIV452X2YL orFIV454X4YL to change level of straight horizontal runs. Cover included.
2x2 1 5
FOV454X4YL 4x4 1 5
Inside Vertical Right Angle FittingFIVRA2X2YL Attaches to channel to create a 90° upward angle
from a straight horizontal run. Used with outsidevertical 90° angle fitting FOVRA2X2YL orFOVRA4X4YL to change level of straight horizontal runs. Cover included.
2x2 1 5
FIVRA4X4YL 4x4 1 5
Outside Vertical Right Angle FittingFOVRA2X2YL Attaches to channel to create a 90° downward
angle from a straight horizontal run. Used withinside vertical 90° angle fitting FIVRA2X2YL orFIVRA4X4YL to change level of straight horizontal runs. Cover included.
2x2 1 5
FOVRA4X4YL 4x4 1 5
4x4 to 2x2 Fiber-Duct ™ Reducer FittingFRF42YL Joins any 4x4 Fiber-Duct ™ Fitting to the 2x2
Fiber-Duct ™ Channel, S2X2YL6 or E2X2YL6.Cover included.
2x24x4
1 5
FEC2X2YL Used for closing off open ends of the channel.No coupler required. Push-on installation.
2x2 1 5
For technical assistance in the U.S., call 866-405-6654 (outside the U.S., see inside back cover for directory)
ELECTRICAL SOLUTIONS
C1.57
B2.Cable
Accessories
C1.Wiring
Duct
C3.Abrasion
Protection
C4.Cable
Management
D1.Terminals
D2.Power
Connectors
E1.LabelingSystems
E2.Labels
E3.Pre-Printed & Write-On
Markers
F.Index
B3.StainlessSteel Ties
C2.Surface
Raceway
E5.Lockout/Tagout
& SafetySolutions
B1.Cable Ties
A.System
Overview
D3.GroundingConnectors
E4.Permanent
Identification
FFWC2X2FFWC4X4
FEC2X2FEC4X4
FIV452X2FIV454X4
FOV452X2FOV454X4
FOVRA2X2FOVRA4X4
FRF42
FT2X2FT4X4
For other colors replace suffix YL (Yellow) with OR (Orange) or BL (Black).Fittings include 5/16" assembly holes for fast mechanical fastening.
Fiber-Duct ™ System Fittings (continued)
FIVRA2X2FIVRA4X4
Courtesy of Steven Engineering, Inc. - (800) 258-9200 - [email protected] - www.stevenengineering.com
ELECTRICAL SOLUTIONS
Order number of pieces required, in multiples of Standard Package Quantity. Prime items appear in BOLD.C1.58
B2.Cable
Accessories
C1.Wiring
Duct
C3.Abrasion
Protection
C4.Cable
Management
D1.Terminals
D2.Power
Connectors
E1.LabelingSystems
E2.Labels
E3.Pre-Printed & Write-On
Markers
F.Index
B3.StainlessSteel Ties
C2.Surface
Raceway
E5.Lockout/Tagout
& SafetySolutions
B1.Cable Ties
A.System
Overview
D3.GroundingConnectors
E4.Permanent
Identification
Fiber-Duct ™ Spillouts
FTR2X2
FIDT2X2
FVT4X4
FTR4X4
FVTHD2X2
FIDT4X4BL
Part Number Part DescriptionSystem
Size
Std.Pkg.Qty.
Std.Ctn.Qty.
2x2 Vertical Tee FVTHD2X2YL Attaches to 2x2 channel to create a 90° vertical drop
from a horizontal run. Hinged door included. Acceptschannel cover in conjunction with channel. UseQuikLock ™ Coupler FBC2X2YL with HS2X2YL6 orH2X2YL6 channels. Use snap rivets NR2WH-L or bolts F14PN-L with S2X2YL6 or E2X2YL6 channels.Also accepts FIDT2X2YL.
2x2 1 5
3-Sided BRC Trumpet Spillout for 2x2 ExitFTR2X2YL Used to limit the bend radius of the cable to 2"
(50.8mm) when exiting from a spill-over junction with a 2x2 exit or from 2x2 Fiber-Duct ™ Channel.
2x2 1 5
1-Port Spillout to 1.5" (38mm) Inside Diameter Corrugated TubingFIDT2X2YL Used to route cable into one piece of 1.5" (38mm)
diameter split corrugated tubing. Used with a spill-overjunction with a 2x2 exit, 2x2 Fiber-Duct ™ Fittings, andthe 2x2 FiberRunner ® Hinged Channel. Securely holdssplit corrugated tubing to ensure system integrity andeasy access to add or remove cables.
2x2 1 5
4x4 Vertical TeeFVT4X4YL Attaches to channel to create a 90° vertical drop from
a horizontal run. Accepts FIDT4X4BL, FTR4X4YL,S4X4YL6 or E4X4YL6 directly.
4x4 1 5
3-Sided Vertical Tee Trumpet SpilloutFTR4X4YL Used to limit the bend radius of the cable to 2"
(50.8mm) when exiting from a 4x4 or 6x4FiberRunner ® Vertical Tee and 4x4 Fiber-Duct ™
Fittings.
4x4 1 5
2-Port Spillout to 1.5" (38mm) Inside Diameter Corrugated TubingFIDT4X4BL Used to route cable into one or two pieces of 1.5"
(38mm) diameter split corrugated tubing. Used withFRVT6X4YL, FRVT4X4YL, or FVT4X4YL. Securelyholds corrugated split tubing to ensure system integrityand easy access to add or remove cables.Black color only.
4x4 1 5
Courtesy of Steven Engineering, Inc. - (800) 258-9200 - [email protected] - www.stevenengineering.com
For technical assistance in the U.S., call 866-405-6654 (outside the U.S., see inside back cover for directory)
ELECTRICAL SOLUTIONS
C1.59
B2.Cable
Accessories
C1.Wiring
Duct
C3.Abrasion
Protection
C4.Cable
Management
D1.Terminals
D2.Power
Connectors
E1.LabelingSystems
E2.Labels
E3.Pre-Printed & Write-On
Markers
F.Index
B3.StainlessSteel Ties
C2.Surface
Raceway
E5.Lockout/Tagout
& SafetySolutions
B1.Cable Ties
A.System
Overview
D3.GroundingConnectors
E4.Permanent
Identification
Fiber-Duct ™ Bend Radius Control Trumpets
• Provide method to transition cabling into rack system •Maintain 1 inch (25.4mm) bend radius control
TRC2BL
TRC4BL
Fiber-Duct ™ Accessories
F14PWN-L
NR2WH-LNR4BL-L
F14PN-L
Part Number Part DescriptionSystem
Size
Std.Pkg.Qty.
Std.Ctn.Qty.
Snap RivetsNR2WH-L Snap rivet fastens channel and fittings together for
added strength and rigidity. Snap rivet mounts flushto surfaces.
2x2 50 500
NR4BL-L 4x4 50 500
Plastic Bolts and NutsF14PWN-L 1/4" plastic bolts and wing nuts fastens channel and
fittings together for added strength and rigidity.2x2 4x4
50 500
Plastic Bolts and NutsF14PN-L 1/4" plastic bolts and hex nuts fastens channel and
fittings together for added strength and rigidity.2x2 4x4
50 500
Part Number Part Description System Size
Std.Pkg.Qty.
Std.Ctn.Qty.
TRC2BL Bend radius control trumpet for exiting at the sidewall of 2" wall heights of type G, FS, E, or SFiber-Duct ™ Channels.
2x2 1 10
TRC4BL Bend radius control trumpet for exiting at the sidewall of 4" wall heights of type G, FS, E, or SFiber-Duct ™ Channels.
4x4 1 10
Courtesy of Steven Engineering, Inc. - (800) 258-9200 - [email protected] - www.stevenengineering.com
ELECTRICAL SOLUTIONS
C1.60
Fiber-Duct ™ Mounting Brackets
B2.Cable
Accessories
C1.Wiring
Duct
C3.Abrasion
Protection
C4.Cable
Management
D1.Terminals
D2.Power
Connectors
E1.LabelingSystems
E2.Labels
E3.Pre-Printed & Write-On
Markers
F.Index
B3.StainlessSteel Ties
C2.Surface
Raceway
E5.Lockout/Tagout
& SafetySolutions
B1.Cable Ties
A.System
Overview
D3.GroundingConnectors
E4.Permanent
Identification
FTRBE12, FTRBE58FTRBE12M
FTRBN12, FTRBN58FTRBN12M
FUSB
FLRB
FLB
FZBA1.5X4
FZBLP
Order number of pieces required, in multiples of Standard Package Quantity. Prime items appear in BOLD.
Part Number Part Description
ForThreaded Rod Size
Std.Pkg.Qty.
Std.Ctn.Qty.
Existing Threaded Rod Bracket for Fiber-Duct ™ SystemFTRBE12 Used for supporting the 2x2 and 4x4 Fiber-Duct ™
Systems from existing threaded rod installations.Bracket is secured to threaded rod with two split nuts.Contains hardware for attaching to threaded rods and hardware for mounting channel to bracket.
1/2" 1 10
FTRBE58 5/8" 1 10
FTRBE12M 12mm 1 10
New Threaded Rod Bracket for Fiber-Duct ™ SystemFTRBN12 Used for supporting the 2x2 and 4x4 Fiber-Duct ™
Systems from new threaded rod installations. Bracketis secured to threaded rod with two nuts. Containshardware for attaching to threaded rods and hardwarefor mounting channel to bracket.
1/2" 1 10
FTRBN58 5/8" 1 10
FTRBN12M 12mm 1 10
Underfloor Pedestal Bracket for Fiber-Duct ™ SystemFUSB Used to support the 2x2 and 4x4 Fiber-Duct ™
Systems by attaching to underfloor pedestal (notincluded). Use on pedestals up to 1” in diameter.Bracket contains hardware to attach to pedestal and hardware for mounting channel to bracket.
— 1 10
Ladder Rack Bracket for Fiber-Duct ™ SystemFLRB Used to support the 2x2 and 4x4 Fiber-Duct ™
Systems attaching directly to any 3/8" (9.5mm) x 1 1/2"(38.1mm) or 3/8" (9.5mm) x 2" (50.8mm) ladderrack rail. No threaded rod required. Contains hardwarefor mounting channel to bracket.
— 1 10
“L” Wall Mount Bracket for Fiber-Duct ™ SystemFLB Used to support 2x2 and 4x4 Fiber-Duct ™ Systems
by attaching to a wall or the front or back of anequipment rack. Contains hardware for mountingchannel to bracket.
— 1 10
Adjustable “Z” BracketFZBA1.5X4 Bracket used to offset Fiber-Duct ™ System from
mounting surface, adjustable from 1.5" (38mm) to 4" (101mm). Typically used on the front of anequipment rack.
— 1 10
Low Profile “Z” BracketFZBLP Bracket used to offset 2x2 or 4x4 Fiber-Duct ™ System
and hinged duct from the front face of an equipmentrack. Bracket provides a secure mounting surface .67" (17mm) from the front of an equipment rack.
— 1 10
Courtesy of Steven Engineering, Inc. - (800) 258-9200 - [email protected] - www.stevenengineering.com
Std.Ctn.Qty.
Std.Pkg.Qty.
ForThreaded Rod SizePart DescriptionPart Number
For technical assistance in the U.S., call 866-405-6654 (outside the U.S., see inside back cover for directory)
ELECTRICAL SOLUTIONS
C1.61
Fiber-Duct ™ Mounting Brackets (continued)
B2.Cable
Accessories
C1.Wiring
Duct
C3.Abrasion
Protection
C4.Cable
Management
D1.Terminals
D2.Power
Connectors
E1.LabelingSystems
E2.Labels
E3.Pre-Printed & Write-On
Markers
F.Index
B3.StainlessSteel Ties
C2.Surface
Raceway
E5.Lockout/Tagout
& SafetySolutions
B1.Cable Ties
A.System
Overview
D3.GroundingConnectors
E4.Permanent
Identification
F2PCLB12F2PCLB58
FRAFC58
Two-Piece Ladder Rack Bracket for Attaching Threaded Rod to 1 1/2" – 2" Ladder RackF2PCLB12 Two-piece bracket attaches to 3/8" (9.5mm) wide x
1 1/2" (38.1mm) or 3/8" (9.5mm) wide x 2" (50.8mm)ladder rack rail. Bracket halves slide into position andclamp together on the ladder rack rail, which allows for a one-handed assembly of the threaded rod (not included). Contains bracket and hardware for attaching bracket to ladder rack.
1/2" 1 10
F2PCLB58 5/8" 1 10
Two-Piece Framing Clip for Attaching 5/8" Threaded Rod to 2" x 9/16" C-ChannelAuxiliary Framing BarsFRAFC58 Two-piece framing clip attaches to auxiliary framing
bars. Framing clip halves slide into position andinterlock on the auxiliary framing bars, allowing easier assembly of the threaded rod to bars.Contains two-piece framing clip and hardware for attaching framing clip to auxiliary framing bars.(5/8” threaded rod not included.)
5/8" 1 10
Courtesy of Steven Engineering, Inc. - (800) 258-9200 - [email protected] - www.stevenengineering.com
ELECTRICAL SOLUTIONS
Order number of pieces required, in multiples of Standard Package Quantity. Prime items appear in BOLD.C1.62
B2.Cable
Accessories
C1.Wiring
Duct
C3.Abrasion
Protection
C4.Cable
Management
D1.Terminals
D2.Power
Connectors
E1.LabelingSystems
E2.Labels
E3.Pre-Printed & Write-On
Markers
F.Index
B3.StainlessSteel Ties
C2.Surface
Raceway
E5.Lockout/Tagout
& SafetySolutions
B1.Cable Ties
A.System
Overview
D3.GroundingConnectors
E4.Permanent
Identification
W
HA = 3.5 in.2
(2258mm2)
4.25"(107.9mm)
A = 14.6 in.2
(9419mm2)
4.10"(104.1mm)
2x2 and 4x4 Fiber-Duct ™ Routing Systems
2.10"(53.3mm)
The maximum amounts may vary according to the cable fill installation methods, straightness of cables, etc.
Cable Fills for 2x2 and 4x4 Fiber-Duct ™ Cable Routing Systems
Channel cutting instructions: For optimum results, use a miter box and saw. For larger quantities use a plastic cutting sawblade for clean, burr-free cuts. Recommend: Carbide 80T and 100T; .090" thickness, .125" kerf.
Channel cutting instructions: For optimum results, use a miter box and saw. For larger quantities use a plastic cutting sawblade for clean, burr-free cuts. Recommend: Carbide 80T and 100T; .090" thickness, .125" kerf.
2.25"(57.1mm)
2x2 Fiber-Duct ™ Cable Routing System
Fill/Pile UpInternalArea In.2
Diameter1.6mm.063"
Diameter2.0mm.079"
Diameter3.0mm.118"
Fiber OpticFlat Ribbon
Interconnect Cable5.20mm
.205"
Category 6ADiameter7.57mm
.298"
Cat. 6Diameter6.35mm
.250"
40% Fill2" Pile Up 3.5 449 288 128 42 20 29
50% Fill2" Pile Up 3.5 562 359 160 53 25 36
60% Fill2" Pile Up 3.5 674 431 192 64 30 43
4x4 Fiber-Duct ™ Cable Routing System
Fill/Pile UpInternalArea In.2
Diameter1.6mm.063"
Diameter2.0mm.079"
Diameter3.0mm.118"
Fiber OpticFlat Ribbon
Interconnect Cable5.20mm
.205"
Category 6ADiameter7.57mm
.298"
Cat. 6Diameter6.35mm
.250"
40% Fill2" Pile Up 7.6 976 624 277 92 44 623" Pile Up 11.3 1450 928 413 137 65 924" Pile Up 14.6 1874 1199 533 177 84 119
50% Fill2" Pile Up 7.6 1219 780 347 115 54 773" Pile Up 11.3 1813 1160 516 171 81 1154" Pile Up 14.6 2343 1499 666 221 105 149
60% Fill2" Pile Up 7.6 1463 936 416 138 65 933" Pile Up 11.3 2176 1392 619 205 97 1384" Pile Up 14.6 2811 1799 800 265 126 178
Courtesy of Steven Engineering, Inc. - (800) 258-9200 - [email protected] - www.stevenengineering.com
For technical assistance in the U.S., call 866-405-6654 (outside the U.S., see inside back cover for directory)
ELECTRICAL SOLUTIONS
C1.63
B2.Cable
Accessories
C1.Wiring
Duct
C3.Abrasion
Protection
C4.Cable
Management
D1.Terminals
D2.Power
Connectors
E1.LabelingSystems
E2.Labels
E3.Pre-Printed & Write-On
Markers
F.Index
B3.StainlessSteel Ties
C2.Surface
Raceway
E5.Lockout/Tagout
& SafetySolutions
B1.Cable Ties
A.System
Overview
D3.GroundingConnectors
E4.Permanent
Identification
NOTES
Courtesy of Steven Engineering, Inc. - (800) 258-9200 - [email protected] - www.stevenengineering.com