Top Banner
Page 1 MODELS QTR080 • QTR110 WARNING TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR IN- JURY TO PERSONS, OBSERVE THE FOLLOWING: 1. Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer at the address or telephone number listed in the warranty. 2. Before servicing or cleaning unit, switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally.When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel. 3. Installation work and electrical wiring must be done by a qualified person(s) in accordance with all applicable codes and standards, including fire-rated construction codes and standards. 4. Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel burning equip- ment to prevent backdrafting. Follow the heating equipment manufacturer’s guideline and safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and the local code authori- ties. 5. When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities. 6. Ducted fans must always be vented to the outdoors. 7. Acceptable for use over a tub or shower when connected to a GFCI (Ground Fault Circuit Interrupter) - protected branch circuit (ceiling installation only). 8. This unit must be grounded. CAUTION 1. For general ventilating use only. Do not use to exhaust hazard- ous or explosive materials and vapors. 2. This product is designed for installation in ceilings up to a 12/12 pitch (45 degree angle). Duct connector must point up. DO NOT MOUNT THIS PRODUCT IN A WALL. 3. To avoid motor bearing damage and noisy and/or unbalanced impellers, keep drywall spray, construction dust, etc. off power unit. 4. Please read specification label on product for further informa- tion and requirements. QTR SERIES VENTILATORS READ AND SAVE THESE INSTRUCTIONS WARRANTY Installer: Leave this manual with the homeowner. OPERATION Use an on/off switch or speed control to operate this ventilator. See “Connect Wiring” for details. To register this product visit: www.broan.com BROAN THREE YEAR LIMITED WARRANTY Broan warrants to the original consumer purchaser of its products that such products will be free from defects in materials or workmanship for a period of three years from the date of original purchase.THERE ARE NO OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. During this three-year period, Broan will, at its option, repair or replace, without charge, any product or part which is found to be defective under normal use and service. THIS WARRANTY DOES NOT EXTEND TO FLUORESCENT LAMP STARTERS AND TUBES.This warranty does not cover (a) normal main- tenance and service or (b) any products or parts which have been subject to misuse, negligence, accident, improper maintenance or repair (other than by Broan), faulty installation or installation contrary to recommended installation instructions. The duration of an implied warranty is limited to the three-year period as specified for the express warranty. Some states do not allow limitation on how long an implied warranty lasts, so the above limitation may not apply to you. BROAN’S OBLIGATION TO REPAIR OR REPLACE, AT BROAN’S OP- TION, SHALL BE THE PURCHASER’S SOLE AND EXCLUSIVE REMEDY UNDER THIS WARRANTY. BROAN SHALL NOT BE LIABLE FOR INCI- DENTAL, CONSEQUENTIAL OR SPECIAL DAMAGESARISING OUT OF OR IN CONNECTION WITH PRODUCT USE OR PERFORMANCE. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation may not apply to you. This warranty gives you specific legal rights, and you may also have other rights, which vary from state to state. This warranty supersedes all prior warranties. To qualify for warranty service, you must (a) notify Broan at the address or telephone number stated below, (b) give the model number and part identification and (c) describe the nature of any defect in the product or part.At the time of requesting warranty service, you must present evidence of the original purchase date. Broan-NuTone LLC Hartford, Wisconsin www.broan.com 800-558-1711 CLEANING & MAINTENANCE For quiet and efficient operation, long life, and attractive appear- ance - lower or remove grille and vacuum interior of unit with the dusting brush attachment. The motor is permanently lubricated and never needs oiling. If the motor bearings are making excessive or unusual noises, replace the blower assembly (includes motor and impeller).
8

Page 1 QTR SERIES VENTILATORS READ AND SAVE THESE …

Feb 12, 2022

Download

Documents

dariahiddleston
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Page 1 QTR SERIES VENTILATORS READ AND SAVE THESE …

Page 1

MODELS QTR080 • QTR110

WARNING TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR IN-JURY TO PERSONS, OBSERVE THE FOLLOWING:1. Usethisunitonlyinthemannerintendedbythemanufacturer.

Ifyouhavequestions,contactthemanufacturerattheaddressortelephonenumberlistedinthewarranty.

2. Beforeservicingorcleaningunit,switchpoweroffatservicepaneland lock theservicedisconnectingmeans topreventpowerfrombeingswitchedonaccidentally.Whentheservicedisconnecting means cannot be locked, securely fasten aprominentwarningdevice,suchasatag,totheservicepanel.

3. Installation work and electrical wiring must be done by aqualified person(s) in accordance with all applicable codesand standards, including fire-rated construction codes andstandards.

4. Sufficientairisneededforpropercombustionandexhaustingof gases through the flue (chimney) of fuel burning equip-ment topreventbackdrafting.Follow theheatingequipmentmanufacturer’sguidelineandsafetystandardssuchasthosepublishedbytheNationalFireProtectionAssociation(NFPA),andtheAmericanSocietyforHeating,RefrigerationandAirConditioningEngineers(ASHRAE),andthelocalcodeauthori-ties.

5. Whencuttingordrilling intowall or ceiling,donotdamageelectricalwiringandotherhiddenutilities.

6. Ductedfansmustalwaysbeventedtotheoutdoors.7. Acceptableforuseoveratuborshowerwhenconnectedto

aGFCI(GroundFaultCircuitInterrupter)-protectedbranchcircuit(ceilinginstallationonly).

8. Thisunitmustbegrounded.

CAUTION 1. Forgeneralventilatinguseonly.Donotusetoexhausthazard-

ousorexplosivematerialsandvapors.2. This product is designed for installation in ceilings up to a

12/12pitch(45degreeangle).Ductconnectormustpointup.DONOTMOUNTTHISPRODUCTINAWALL.

3. Toavoidmotorbearingdamageandnoisyand/orunbalancedimpellers,keepdrywallspray,constructiondust,etc.offpowerunit.

4. Pleasereadspecificationlabelonproductforfurtherinforma-tionandrequirements.

QTR SERIESVENTILATORS

READ AND SAVE THESE INSTRUCTIONS

WARRANTY

Installer: Leave this manual with the homeowner.

OPERATIONUseanon/offswitchorspeedcontroltooperatethisventilator.See“ConnectWiring”fordetails.

To register this product visit:www.broan.com

BROANTHREEYEARLIMITEDWARRANTYBroanwarrantstotheoriginalconsumerpurchaserofitsproductsthatsuchproductswillbefreefromdefectsinmaterialsorworkmanshipforaperiodofthreeyearsfromthedateoforiginalpurchase.THEREARENOOTHERWARRANTIES,EXPRESSORIMPLIED,INCLUDING,BUTNOTLIMITEDTO,IMPLIEDWARRANTIESOFMERCHANTABILITYORFITNESSFORAPARTICULARPURPOSE.Duringthisthree-yearperiod,Broanwill,atitsoption,repairorreplace,withoutcharge,anyproductorpartwhichisfoundtobedefectiveundernormaluseandservice.THISWARRANTY DOES NOT EXTENDTO FLUORESCENT LAMPSTARTERSANDTUBES.Thiswarrantydoesnotcover(a)normalmain-tenanceandserviceor(b)anyproductsorpartswhichhavebeensubjecttomisuse,negligence,accident, impropermaintenanceor repair (otherthanbyBroan),faultyinstallationorinstallationcontrarytorecommendedinstallationinstructions.Thedurationofanimpliedwarrantyislimitedtothethree-yearperiodasspecified for the express warranty. Some states do not allow limitationonhowlongan impliedwarranty lasts,so theabove limitationmaynotapplytoyou.BROAN’SOBLIGATIONTOREPAIRORREPLACE,ATBROAN’SOP-TION,SHALLBETHEPURCHASER’SSOLEANDEXCLUSIVEREMEDYUNDERTHISWARRANTY.BROANSHALLNOTBELIABLEFORINCI-DENTAL,CONSEQUENTIALORSPECIALDAMAGESARISINGOUTOFORINCONNECTIONWITHPRODUCTUSEORPERFORMANCE.Somestatesdonotallowtheexclusionorlimitationofincidentalorconsequentialdamages,sotheabovelimitationmaynotapplytoyou.Thiswarrantygivesyouspecificlegalrights,andyoumayalsohaveotherrights,whichvaryfromstatetostate.Thiswarrantysupersedesallpriorwarranties.Toqualifyforwarrantyservice,youmust(a)notifyBroanattheaddressortelephonenumberstatedbelow,(b)givethemodelnumberandpartidentificationand(c)describethenatureofanydefectintheproductorpart.Atthetimeofrequestingwarrantyservice,youmustpresentevidenceoftheoriginalpurchasedate.Broan-NuToneLLCHartford,Wisconsinwww.broan.com800-558-1711

CLEANING & MAINTENANCEForquietandefficientoperation,longlife,andattractiveappear-ance-lowerorremovegrilleandvacuuminteriorofunitwiththedustingbrushattachment.

Themotorispermanentlylubricatedandneverneedsoiling.Ifthemotorbearingsaremakingexcessiveorunusualnoises,replacetheblowerassembly(includesmotorandimpeller).

Page 2: Page 1 QTR SERIES VENTILATORS READ AND SAVE THESE …

Page 2

MODELS QTR080 • QTR110

TYPICAL INSTALLATIONS

Housing mounted to I-joists.Use I-joist spacer block (provided).

Housing mounted to joists.

Housing mounted to truss.

PLAN THE INSTALLATION

CookingEquipment

Floor

COOKING AREADo not install above or

inside this area.

45o 45o

NOT FOR USE INA COOKING AREA.

Theunitwilloperatemostquietlyandefficientlywhen locatedwheretheshortestpossibleductrunandminimumnumberofelbowswillbeneeded.

Usearoofcaporwallcapthathasabuilt-indampertoreducebackdrafts.

Plantosupplytheunitwithproperlinevoltageandappropriatepowercable.

ROOFCAP*

4-IN.ROUNDELBOW(S)*

4-IN.ROUNDDUCT*

WALLCAP*

*Purchase separately

INSULATION(Canbeplacedaroundandover

fanhousing.)

FANHOUSING

Page 3: Page 1 QTR SERIES VENTILATORS READ AND SAVE THESE …

Page 3

MODELS QTR080 • QTR110

5. Connect electrical wiring. Run120VAChousewiringtoinstallationlocation.Use

properULapprovedconnectortosecurehousewiringtowiringplate.Connectwiresasshowninwiringdiagrams.

CONNECT WIRING

3. Attach damper/duct connector.

Snapdamper/ductconnectorontohousing.Makesurecon-nectorisflushwithtopofhousinganddamperflapfallsclosed.

4. Install 4-inch round duct-work.

Connect4-inchroundductworktodamper/ductconnector.Runductworktoaroofcaporwallcap.Tapeallductworkconnectionstomakethemsecureandairtight.

INSTALL HOUSING & DUCT1. Bend

housing tabs.

UseaplierstobendhousingTABSoutto900.

2. Mount housing to joist.

Holdhousinginplacesothatthehousingtabscontactthebottomofthejoist.Thehous-ingmountswithfour(4)screwsornails.Screwornailhousingtojoistthroughlowestholesineachmount-ingflange,thenthroughhighestholes.NOTE:MountingtoI-JOIST(shown)requiresuseofSPACERS(included)betweenthehighestholeofeachmountingflangeandtheI-joist.

SPACER(useformountingtoI-Joist)

I-JOIST

TABS

Page 4: Page 1 QTR SERIES VENTILATORS READ AND SAVE THESE …

Page 4

MODELS QTR080 • QTR110

SERVICE PARTS

99044600A

Key No. Part No. Description

1 97016466 Housing 2 97016449 DuctConnector-4” 3 98010102 WiringPlate 4 99170245 Screw,#8-18X.375 5 97018010 WirePanel/HarnessAssembly 6 97016621 BlowerAssembly(QTR080) 97018218 BlowerAssembly(QTR110) 7 97016497 GrilleAssembly (includeskeyno.8) 8 99140199 GrilleSpring(2req’d) 9 97018014 Spacer(2supplied) 10 99420665 Thumbscrew,#8-18x.375

INSTALL GRILLE

7. Attach grille to housing.

Squeezegrillespringsandinsertthemintoslotsoneachsideofhous-ing.

8. Push grille against ceiling.

6. Finish ceiling. Installceilingmaterial.Cutoutaroundhousing.

SERVICE NOTE

ToremoveBlowerAssembly:

Unplugmotor.

Removethumbscrew(10)frommotorplateflange.

FindthesingleTABonthemotorplate(locatednexttothereceptacle).

Pushupnearmotorplatetabwhilepushingoutonsideofhousing.Orinsertastraight-bladescrewdriverintoslotinhousing(nexttotab)andtwistscrewdriver.

Orderservicepartsby“PartNo.”-notby“KeyNo.”

Replacement parts can be ordered on our web-site. Please visit us at

www.broan.com

Page 5: Page 1 QTR SERIES VENTILATORS READ AND SAVE THESE …

Página 5

MODELOS QTR080 • QTR110

VENTILADORES SERIE QTR

ADVERTENCIA PARA REDUCIR EL RIESGO DE INCENDIOS, DESCARGAS ELÉCTRICAS O LESIONES PERSONALES, OBSERVE LAS SIGUIENTES PRECAUCIONES:1. Uselaunidadsólodelamaneraindicadaporelfabricante.Si

tienepreguntas,comuníqueseconelfabricantealadirecciónoalnúmerotelefónicoqueseincluyenenlagarantía.

2. Antesdedarservicioalaunidadodelimpiarla,interrumpaelsuministroeléctricoenelpaneldeservicioybloqueelosme-diosdedesconexióndelservicioparaevitarquelaelectricidadsereanudeaccidentalmente.Cuandonoseaposiblebloquearlosmediosdedesconexióndelservicio, fije firmementeundispositivodeadvertencia(porejemplo,unaetiqueta)enunlugarprominentedelpaneldeservicio.

3. Eltrabajodeinstalaciónyelcableadoeléctricodebenserre-alizadosporunaomáspersonascalificadas,ydebencumplircontodosloscódigosynormascorrespondientes,incluidosloscódigosynormasdeconstrucciónespecíficosdeproteccióncontraincendios.

4. Se necesita suficiente aire para que se lleve a cabo unacombustión adecuada y para la descarga de los gases atravésdeltubodehumos(chimenea)delequipoquemadordecombustible,afindeevitarlascontracorrientes.Sigalasdirectricesynormasdeseguridaddelfabricantedelequipodecalentamiento,talescomolaspublicadasporlaAsociaciónNacionaldeProteccióncontraIncendios(NationalFireProtec-tionAssociation,NFPA),laSociedadAmericanadeIngenierosdeCalefacción,RefrigeraciónyAireAcondicionado(AmericanSocietyforHeating,RefrigerationandAirConditioningEngi-neers,ASHRAE)ylasautoridadesdeloscódigoslocales.

5. Alcortaroperforaratravésdelaparedodelcieloraso,nodañeelcableadoeléctriconiotrosserviciosocultos.

6. Losventiladoresconconductosdebensiempreconectarsehaciaelexterior.

7. EsaceptableutilizaresteproductosobreunaregaderaotinasiseconectaauncircuitosecundarioprotegidoporunGFCI(interruptoraccionadoporpérdidadeconexiónatierra)(in-stalacióndeltechosolamente).

8. Estaunidaddebeconectarseatierra.

PRECAUCIÓN 1. Sóloparausarloenventilacióngeneral.Nolouseparades-

cargarmaterialesnivaporespeligrososoexplosivos.2. Esteproductosediseñaparalainstalaciónentechoshasta

unaechadade12/12(ángulode45grados).NOMONTEESTEPRODUCTOENUNATECHO.

3. Paraevitardañosaloscojinetesdelmotoryrotoresruidososy/onoequilibrados,mantengalaunidaddeaccionamientoalresguardoderocíodeyeso,polvodelaconstrucción,etc.

4. Lea la etiqueta de especificaciones del producto para verinformaciónyrequisitosadicionales.

LEA Y CONSERVE ESTAS INSTRUCCIONES

GARANTÍA

A la persona que realiza la instalación: Deje este manual con el dueño de la casa.

OPERACIÓNOpere este ventilador mediante un interruptor de encendido/apagadoocontroldevelocidad.Vealosdetallesenlasección“Conexióneléctrica”.

Para registrar este producto visite:www.broan.com

GARANTÍALIMITADADETRESAÑOSDEBROAN-NUTONEBroan-NuTone garantiza al consumidor comprador original que susproductosestarán libresdedefectosencuantoamaterial ymanosdeobraduranteunperíododetresañosapartirdelafechadelacompraoriginal.NOEXISTENOTRASGARANTÍAS,EXPRESASNIIMPLÍCITAS,INCLUIDAS(PEROSINLIMITARSEA)GARANTÍASIMPLÍCITASDECO-MERCIALIZACIÓNOIDONEIDADPARAUNPROPÓSITOPARTICULAR.Duranteesteperíododetresaños,Broan-NuTone,asucriterio,repararáoreemplazará,sincargoalgtreso,cualquierpiezaoproductoqueseen-cuentredefectuosobajocondicionesnormalesdeusoyservicio.ESTAGARANTÍANOSEAPLICAAARRANCADORESNIATUBOSDELÁMPARASFLUORESCENTES.Estagarantíanocubre(a)mantenimientooservicionormalesni(b)productosopiezasquesehayansometidoausoinadecuado,negligencia,accidente,mantenimientooreparacióninadec-uada(nohechaporBroan-NuTone),instalaciónincorrectaoinstalaciónencontradelasinstruccionesdeinstalaciónrecomendadas.Laduracióndeunagarantíaimplícitaselimitaalperíododetresaños,comoseespecificaparalagarantíaexplícita.Algtresosestadosnopermitenlimitarladuracióndeunagarantíaimplícita,demaneraquelaslimitacionesantedichaspodríannoaplicarseausted.LAOBLIGACIÓNDEBROAN-NUTONEDEREPARAROREEMPLAZAR,AOPCIÓNDEBROAN-NUTONE,SERÁELÚNICOYEXCLUSIVORE-CURSODELCOMPRADORBAJOESTAGARANTÍA.BROAN-NUTONENOSERÁRESPONSABLEPORDAÑOSINCIDENTALES,RESULTANTESOESPECIALESQUESURJANDE,OENRELACIÓNCON,ELUSOORENDIMIENTODELPRODUCTO.Algtresosestadosnopermitenexcluirolimitardañosincidentalesoresultantes,demaneraqueesposiblequelalimitaciónantedichanoseapliqueensucaso.Estagarantíaledaderechoslegalesespecíficos;ustedpodríatenerotrosderechos que varían entre estados. Esta garantía sustituye todas lasgarantíasanteriores.Paratenerderechoalserviciodelagarantía,usteddebe(a)notificaraBroan-NuTonealadirecciónynúmerodeteléfonoqueaparecenabajo,(b) proporcionarel númerodemodelo y la identificaciónde lapiezay(c)describir lanaturalezadecualquierdefectoenelproductoopieza. Enelmomentodesolicitarelserviciodelagarantía,debepresentarelcomprobanteconlafechadelacompraoriginal.Broan-NuToneLLCHartford,Wisconsinwww.broan.com800-558-1711

LIMPIEZA Y MANTENIMIENTOParalograrunfuncionamientosilenciosoyeficiente,comotam-biénlargavidayunaaparienciaatractiva,bajeoretirelarejillayaspireelinteriordelaunidadconelaccesoriodelcepilloparasacudirpolvo.Elmotorestápermanentemente lubricadoynuncanecesitaráaceite.Siloscojinetesdelmotorestánhaciendoruidoexcesivooinusual,reemplaceelconjuntodelventilador(incluyeelmotoryelrodetedelventilador).

Page 6: Page 1 QTR SERIES VENTILATORS READ AND SAVE THESE …

Página 6

MODELOS QTR080 • QTR110

INSTALACIONES TÍPICAS

Montaje de cubierta en viguetas “I”.Utilice un taco separador de viguetas “I” (suministrado).

Montaje de cubierta en viguetas.

Montaje de cubierta en armadura.

PLANIFICACIÓN DE LA INSTALACIÓN

Equipopara cocinar

Piso

ÁREA QUE COCINANo instale sobre o dentro

de esta área.

45o 45o

NO PARA ELUSO EN UN

ÁREA QUE COCINA.

Elventiladorfuncionaráconmáseficienciaymenosruidosiseubicaenunsitiodonderequieraeltramodeconductomáscortoposibleyunmínimonúmerodecodos.

Instaleunatapadetechoodeparedquetengaunreguladordetiroincorporadoafindereducirloscontratiros.

Alimente launidadconel voltajede líneayel cableeléctricoapropiados.

CODO REDONDODE 4 PULG. *

CUBIERTA DEVENTILADOR

CONDUCTOREDONDO DE

4 PULG. ** Se compran

por separado

TAPA DE

PARED*

TAPA DETECHO *

AISLAMIENTO(Puede ser colo-cado alrededor y

sobre de la cubierta del ventilador.)

Page 7: Page 1 QTR SERIES VENTILATORS READ AND SAVE THESE …

Página 7

MODELOS QTR080 • QTR110

5. Conecte los cables eléctricos.Extiendaelcableadodelacasade120VCAallugardelainstalación.UtiliceunaconexiónaprobadaporULparaafianzarelcableadodelacasaalaplacadecableado.Conecteloscablestalcomoseilustraenlosdiagramasdecableado.

CONEXIÓN ELÉCTRICAINSTALE LA CUBIERTA Y EL CONDUCTO1. Doble las

lengüetas de la cubierta.Conunalicate,doblelasLENGÜE-TASdelacubiertaa90o.

LENGÜETAS

3. Acople el conector del regulador de tiro/conducto.Conecteapresiónelconectordelregu-ladordetiro/con-ductoenlacubierta.Asegúresedequeelconectorestéalrasconlapartesuperiordelacubiertayquelaaletadelreguladorcaigacerrada.

4. Instale el conducto redondo de 4 pulgadas.Conecteelcon-ductoredondode4pulgadasalconec-tordelregulador/conducto.Extiendaelconductohaciaunatapadetechootapadepared.Encintetodaslasconexionesdelosconductosparafijarlasyhacerlasherméticasalaire.

2. Monte la cubierta en la vigueta.Sostengalacubi-ertaensulugardemaneraquelaslengüetasdelacubiertahagancontactoconlaparteinferiordelavigueta.Paraelmontajedelacubiertaseutilizancuatro(4)tornillosoclavos.Atornilleoclavelacubiertaalaviguetaatravésdelosorifi-ciosmásbajosdecadabridademontaje,yseguidamenteatravésdelosmásaltos.NOTA:ElmontajealaVIGUETA “I”(mostrada)requiereutilizarSEPARADORES(incluidos)entreelorificiomásaltodecadabridademontajeylavigueta“I”.

SEPARADOR(seusaparaelmontaje

alavigueta“I”)

VIGUETA“I”

Page 8: Page 1 QTR SERIES VENTILATORS READ AND SAVE THESE …

Página 8

MODELOS QTR080 • QTR110

PIEZAS DE REPUESTO

99044600A

Clave n.o Pieza n.o Descripción

1 97016466 Cubierta 2 97016449 Conectordelconducto(4pulg.) 3 98010102 Placadecableado 4 99170245 Tornillon.o8-18x0.375 5 97018010 Conjuntodelpaneldecableado/arnés 6 97016621 Conjuntodelventilador(QTR080) 97018218 Conjuntodelventilador(QTR110) 7 97016497 Conjuntodelarejilla (incluyeclaven.o8) 8 99140199 Resortedelarejilla(serequieren2) 9 97018014 Separador(sesuministran2) 10 99420665 Tornillodemariposan.o8-18x0.375

INSTALE LA REJILLA

7. Acople la rejilla a la cubierta.Aprietelosresortesdelarejillaeinsér-telosenlasranurasqueseencuentranacadaladodelacubierta.

8. Empuje la rejilla contra el cielo raso.

6. Termine el cielo raso. Instaleelmaterialdelcieloraso.Recortealrededordelacubierta.

NOTA DE SERVICIO

Paradesmontarelconjuntodelventilador:

Desenchufeelmotor.

Saqueeltornillodemariposa(10)delabridadelaplacadelmotor.

LocalicelaLENGÜETAúnicadelaplacadelmotor(seencuentrajuntoalreceptáculo).

Empujehaciaarribacercadelalengüetadelaplacadelmotoralmismotiempoqueempujahaciaafueraelcostadodelacubierta.Obien,introduzcaundestornilladordepuntarectaenlaranuradelacubierta(juntoalalengüeta)ygírelo.

Alhacerelpedidodeunapiezadeserviciosedebeespecificarelnúmerodelapieza(noelnúmerodelaclave).

Las piezas de recambio se

pueden ahora pedir en nuestro Web site.

Visítenos por favor en www.broan.com