Top Banner
Packaged Terminal Air Conditioners New Design 2012-PTAC
23

Packaged Terminal Air Conditioners New Design 2012-PTAC.

Mar 28, 2015

Download

Documents

Eva Lonon
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Packaged Terminal Air Conditioners New Design 2012-PTAC.

Packaged Terminal Air Conditioners( New Design)

2012-PTAC

Packaged Terminal Air Conditioners( New Design)

2012-PTAC

Page 2: Packaged Terminal Air Conditioners New Design 2012-PTAC.

Generation Two - PTACGeneration Two - PTAC1

Product Lineup and Features Product Lineup and Features 2

New Panel and AssemblyNew Panel and Assembly3

CONTENTS

Page 3: Packaged Terminal Air Conditioners New Design 2012-PTAC.

Generation Two - PTACGeneration Two - PTAC1

In collaboration with our customers we are pleased to introduce our new PTAC lineup. Improvements include:

A more user and installer friendly high performance product range. A refined and more elegant appearance. Ease of assembly and maintenance through the use of innovative sub-assemblies.Better noise control by using plastic sealing motor matching bigger diameter blower wheel.

In collaboration with our customers we are pleased to introduce our new PTAC lineup. Improvements include:

A more user and installer friendly high performance product range. A refined and more elegant appearance. Ease of assembly and maintenance through the use of innovative sub-assemblies.Better noise control by using plastic sealing motor matching bigger diameter blower wheel.

Page 4: Packaged Terminal Air Conditioners New Design 2012-PTAC.

1. Unit Types: Cool only Cool only with electric heater Heat pump with electric heater

2. Available Capacities: 7K Btu, 9K Btu ,12K Btu, 15K Btu

3. Power Arrangements: 208~230V/1Ph/60Hz 265V/1Ph/60Hz

Product Lineup and FeaturesProduct Lineup and Features

22

22

Page 5: Packaged Terminal Air Conditioners New Design 2012-PTAC.

Product Lineup and FeaturesProduct Lineup and Features2

FEATURESFEATURES ::FEATURESFEATURES ::

15 Second Fan Off Delay

Random Compressor Restart

Comfort Control Design

Room Freeze Protection

Self Diagnostics

Effortless™ Maintenance

24 Hour On/Off Timer

Highly Energy - EfficientHighly Energy - Efficient

Multi-Speed Fan

Silent Design

Memory

Automatic Auxiliary Heat

Eco-Friendly with R410a Refrigerant

Versatile Multi-Mode Operation

Page 6: Packaged Terminal Air Conditioners New Design 2012-PTAC.

Features and Benefits3

Highly Energy Efficient

The units are matched with a variety of leading brand compressors coupled with the use of more energy efficient motors and fans. Our R&D team has chosen the most energy efficient combinations.

Highly Energy Efficient

The units are matched with a variety of leading brand compressors coupled with the use of more energy efficient motors and fans. Our R&D team has chosen the most energy efficient combinations.

Quiet Operation:

Our new unit is much quieter in operation because of the high quality cross flow fan design, hermetically sealed plastic motor, and improved air flow design. Additionally the compressor noise has been isolated from the indoor section by use of an acoustically reinforced center panel.

Quiet Operation:

Our new unit is much quieter in operation because of the high quality cross flow fan design, hermetically sealed plastic motor, and improved air flow design. Additionally the compressor noise has been isolated from the indoor section by use of an acoustically reinforced center panel.

Page 7: Packaged Terminal Air Conditioners New Design 2012-PTAC.

Features and Benefits3

Random Compressor Restart

To help prevent power surges after a power outage or from many of our PTACs starting at the same time, the compressor is equipped with a 120 to 240 second random restart delay feature. Whenever the unit is plugged in or power has been restored, a random compressor restart will occur.

Random Compressor Restart

To help prevent power surges after a power outage or from many of our PTACs starting at the same time, the compressor is equipped with a 120 to 240 second random restart delay feature. Whenever the unit is plugged in or power has been restored, a random compressor restart will occur.

Auto Restart Memory

Our new units have a power off memory function. If power is ever lost or the unit is off control settings are memorized (set point, mode, fan speed). When power is restored or the unit is turned on the previous settings will operate.

Auto Restart Memory

Our new units have a power off memory function. If power is ever lost or the unit is off control settings are memorized (set point, mode, fan speed). When power is restored or the unit is turned on the previous settings will operate.

Page 8: Packaged Terminal Air Conditioners New Design 2012-PTAC.

New Panel and Assembly New Panel and Assembly 2

Shear elegance.

Page 9: Packaged Terminal Air Conditioners New Design 2012-PTAC.

Front panel Electronic control box Base pan

Wall sleeve

Grille

Indoor side

Outdoor side

New Panel and AssemblyNew Panel and AssemblyNew Panel and AssemblyNew Panel and Assembly33

Compact structure based on maintenance friendly sub assemblies designCompact structure based on maintenance friendly sub assemblies design

Page 10: Packaged Terminal Air Conditioners New Design 2012-PTAC.

New Panel and Assembly New Panel and Assembly 2

The elegance is matched with improved inlet and exhaust air performance.

CoolingHeating

Air Filter

Page 11: Packaged Terminal Air Conditioners New Design 2012-PTAC.

The leaf and horizontal plane form a 75°angle.

Rotating 180°from right to left the leaf and

horizontal plane form a 39°angle

◆ A unique air flow design with 2 adjustable angles to ensure maximum comfort

New Panel and AssemblyNew Panel and Assembly 3

When Cooling, air is discharged at 75°as cool air falls.

When Heating, air is discharged at 39°as warm air rises, also unit factory status

Page 12: Packaged Terminal Air Conditioners New Design 2012-PTAC.

◆ Indoor air flow sub assembly can be removed as shown, which is ideal for maintenance and cleaning.

◆ Integrated structure also ensure blower wheel better position fixing and rotation balance to cut down noise

New Panel and AssemblyNew Panel and Assembly 3

Page 13: Packaged Terminal Air Conditioners New Design 2012-PTAC.

◆ Use of a larger cross flow fan: Φ120 ×700mm

◆ Plastic sealed motor ensures a quieter and more reliable operation

◆ Well mounted and strong assembly

New Panel and AssemblyNew Panel and Assembly 3

Fan Balancing

Page 14: Packaged Terminal Air Conditioners New Design 2012-PTAC.

The electronic control box is sealed for fire

safety.

The electronic control box can be opened and is conveniently

located for installation and maintenance.

◆ Sealed electronic control box with easy access and fire-proof with better safety control

New Panel and AssemblyNew Panel and Assembly 3

Page 15: Packaged Terminal Air Conditioners New Design 2012-PTAC.

Intelligent electronic control board

New Panel and AssemblyNew Panel and Assembly 3

Optional universal electric heater

(3+2) type heater optional 2/3/5 kw heater (3+2) type heater optional 2/3/5 kw heater

Page 16: Packaged Terminal Air Conditioners New Design 2012-PTAC.

When closed only the air inside the room is circulated and filtered.

When opened outdoor air will be filtered and drawn into the room.

Control lever

New Panel and Assembly New Panel and Assembly 2

Fresh air intake with a manual control lever conveniently located on the side of the unit.

Fresh air intake with a manual control lever conveniently located on the side of the unit.

Page 17: Packaged Terminal Air Conditioners New Design 2012-PTAC.

◆ Outdoor sub assembly structure can easily be removed independently for convenient disassembly and cleaning.

◆ Outdoor sub assembly structure can easily be removed independently for convenient disassembly and cleaning.

New Panel and AssemblyNew Panel and Assembly 3

Page 18: Packaged Terminal Air Conditioners New Design 2012-PTAC.

◆ The condenser axial fan has three blades which provide for greater air flow.

◆ Additionally we have added a water slinger feature to enhance the condensate management system.

◆ The condenser axial fan has three blades which provide for greater air flow.

◆ Additionally we have added a water slinger feature to enhance the condensate management system.

New Panel and AssemblyNew Panel and Assembly 3

Greater Air FlowGreater Air Flow

Water Slinger FanWater Slinger Fan

Page 19: Packaged Terminal Air Conditioners New Design 2012-PTAC.

◆ Drainage tray and Base pan designed for enhanced drainage.

Base pan

Combination

Drainage Tray

New Panel and AssemblyNew Panel and Assembly 3

Page 20: Packaged Terminal Air Conditioners New Design 2012-PTAC.

New Panel and Assembly New Panel and Assembly 2

Improved drainage device with easy access. Heat pump models only.

Improved drainage device with easy access. Heat pump models only.

Page 21: Packaged Terminal Air Conditioners New Design 2012-PTAC.

◆ Standard wall sleeve ◆ Standard wall sleeve

42 ″

16 ″

14 ″

New Panel and AssemblyNew Panel and Assembly 3

Knocked down for convenient transportation

Knocked down for convenient transportation

Standard size 42″×16″×14″.

Standard size 42″×16″×14″.

Page 22: Packaged Terminal Air Conditioners New Design 2012-PTAC.

◆Four Control Options◆Four Control Options

Remote ControlRemote Control

Panel ControlPanel Control

Wireless ControlWireless Control

New Panel and AssemblyNew Panel and Assembly 3

Wired ControlWired Control

Page 23: Packaged Terminal Air Conditioners New Design 2012-PTAC.

Thank you!