EM15038 - EM15055 - EE15115 - ER15014 - ER16003 1 / 3 IT2647 T Technical information Heading No 7 Domestic hot water tanks Thermodynamic water heater KALIKO TWH 200E - TWH 300E - TWH 300EH Product evolution P5253 JS F 67580 Mertzwiller N° IT2647-en 03/03/2016 Technical Sales Documentation Department EN 1. Main modifications 1. New PCU-195-PCB with new programme version 1.5 (For more details about these modifications, see hereafter). The new board is compatible with previous appliance versions. Application date in production: Week 09/2016. 2. Lower sensor removed. 3. TWH 300... : Due to the removal of the lower sensor, the TWH 200 front panel (with short cover) can also be used on this model. Forecasted application date in production: Week 17/2016. 4. Use of the same thermostat as on TWH 200 EV versions. The previous thermostat version had a controller function that was not used. Previous version New version 3 TWH 300 EH
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
TTechnical information
Heading No 7Domestic hot water tanks
Thermodynamic water heater
KALIKOTWH 200E - TWH 300E - TWH 300EH
Product evolutionP5253 JS F 67580 Mertzwiller N° IT2647-en 03/03/2016
Technical Sales Documentation Department
EN
1. Main modifications
1. New PCU-195-PCB with new programme version 1.5 (For more details about these modifications, see hereafter).The new board is compatible with previous appliance versions.Application date in production: Week 09/2016.
2. Lower sensor removed.
3. TWH 300... : Due to the removal of the lower sensor, the TWH 200 front panel (with short cover) can also be usedon this model. Forecasted application date in production: Week 17/2016.
4. Use of the same thermostat as on TWH 200 EV versions. The previous thermostat version had a controller functionthat was not used.
2. Updating of the PCU-195 software version : F 1.5The new board is compatible with previous appliance versions.An updating of the software version of the PCU-195 board is not possible : replace the board if necessary. Apreventive replacement is not necessary.The software version is displayed when the appliance is switched on. The program version is also written on thelabel sticked on the board:
Following parameters added:
* = Minimum room temperature for compressor operation = Maximum room temperature for compressor operation.
(1) Note: When parameter is set to 1 (= electric back-up), the control system anticipates the back-up starting,depending on the temperature, the volume of the calorifier, the power of the back-up and the parameter setting(= maximum charging time).
Parameters Description Adjustment range
Factory setting
Activation of the optimised operating mode: The domestic hot watertank is filled by optimal use of the heat pump and the hydraulic back-up. Parameters and define the room temperaturelimits for the heat pump operation.- 0 = Optimised mode deactivated, the display is normal and
parameters * and * are not accessible.- 1 = Optimised mode active. is displayed and parameters
* and * are accessible.
0 - 1 0
(1) Electrical resistor output. Unit: 0,1 kW 16 - 255 24Lower DHW sensor presence:0 = no lower DHW sensor connected. 1 = If a lower DHW sensor is detected, this parameter isautomatically set to 1. The operation takes into account themeasured DHW temperature.