Sensitivity–leading level sensitivity for the analysis of limited and precious samples Proof of performance Summary In proteomics, sensitivity is essential for studying samples that either have very limited total protein amount, or when biology is driven by proteins that are expressed in low abundance. High sensitivity is needed not only for the detection and identification of proteins, but also for quantitative studies that reveal their biological significance. This document presents results that demonstrate the high sensitivity and selectivity of the Thermo Scientific ™ Orbitrap Exploris ™ 240 mass spectrometer equipped with the Thermo Scientific ™ FAIMS Pro ™ interface to analyze low sample amounts. Thermo Scientific ™ Orbitrap ™ technology has proven in peer reviewed publications to demonstrate the sensitivity to analyze true single cells 1 . This new level of sensitivity is essential for limited samples and for single cells or rare cells, such as circulating tumor cells. Here, we demonstrate that the Orbitrap Exploris 240 MS can deliver high performance for shotgun proteomics experiments from low sample amounts of 10 ng, to higher loads of 200 ng, for both peptide and protein identification. Additionally, we present data on five replicate injections of 10 ng of Thermo Scientific ™ Pierce ™ HeLa Protein Digest Standard, spiked with the Thermo Scientific ™ Pierce ™ Peptide Retention Time Calibration Mixture (PRTC). In such experiments, standard peptides spiked in at 10 fmol dominate the chromatogram, the combination of the Orbitrap Exploris 240 MS and FAIMS Pro interface enables reproducible identification of a low abundant peptide precursor. Orbitrap Exploris 240 mass spectrometer
4
Embed
P roof of performance - Thermo Fisher Scientific...P roof of performance Summary In proteomics, sensitivity is essential for studying samples that either have very limited total protein
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Sensitivity–leading level sensitivity for the analysis of limited and precious samples
Proof of performance
SummaryIn proteomics, sensitivity is essential for studying samples that either have very limited total protein amount, or when biology is driven by proteins that are expressed in low abundance. High sensitivity is needed not only for the detection and identification of proteins, but also for quantitative studies that reveal their biological significance.
This document presents results that demonstrate the high sensitivity and selectivity of the Thermo Scientific™ Orbitrap Exploris™ 240 mass spectrometer equipped with the Thermo Scientific™ FAIMS Pro™ interface to analyze low sample amounts. Thermo Scientific™ Orbitrap™ technology has proven in peer reviewed publications to demonstrate the sensitivity to analyze true single cells1. This new level of sensitivity is essential for limited samples and for single cells or rare cells, such as circulating tumor cells.
Here, we demonstrate that the Orbitrap Exploris 240 MS can deliver high performance for shotgun proteomics experiments from low sample amounts of 10 ng, to higher loads of 200 ng, for both peptide and protein identification.
Additionally, we present data on five replicate injections of 10 ng of Thermo Scientific™ Pierce™ HeLa Protein Digest Standard, spiked with the Thermo Scientific™ Pierce™ Peptide Retention Time Calibration Mixture (PRTC). In such experiments, standard peptides spiked in at 10 fmol dominate the chromatogram, the combination of the Orbitrap Exploris 240 MS and FAIMS Pro interface enables reproducible identification of a low abundant peptide precursor.
Orbitrap Exploris 240 mass spectrometer
Time (min) B%
0 3
1 3
55 19
76 29
91 41
94 95
101 95
Best-in-class sensitivity: When the highest sensitivity data is key to obtain insights that are actionable, the Orbitrap Exploris 240 MS with the FAIMS Pro interface delivers increased sensitivity and selectivity that enable the reproducible identification of low abundant proteins or low level samples.
Experimental conditionsSample• Pierce HeLa Protein Digest Standard (Cat # 88329) 10 ng
Figure 1. Performance benchmark for protein identification at low peptide levels: Histograms of the number of (a) peptide groups and (b) protein groups identified per run as a function of the peptide amount loaded on column from a HeLa cell digest sample. All the identifications are derived at least from a high-confidence peptide spectrum match. Base peak chromatograms for 5 different injection replicates of 10 ng injection, and extracted ion chromatogram for a low intensity peptide.
MS detection• High-resolution, accurate-mass (HRAM) Orbitrap Exploris
Results• Deep proteome coverage on low amounts of sample:
From very sensitive measurements at only 10 ng sample amount resulted in high-confidence identification of 1,600 protein groups and 5,300 peptide groups on an Orbitrap Exploris 240 mass spectrometer (Figure 1a & b).
• Extremely reproducible identification of peptide precursors were obtained across five replicates of the 10 ng sample (Figure 2b).
(a) NQDNLQGWNK
Replicate 4
Replicate 3
Replicate 2
Replicate 1
(b)
0 20 40 60 80 100
Time (min)
30.0 35.0
Figure 2. Five replicate injections of 10 ng Pierce HeLa Digest standard spiked with the Pierce Peptide Retention Time Calibration mixture. (a) While the standard peptides spiked in at 10 fmol dominate the chromatogram, (b) the combination of the Orbitrap Exploris 240 MS and FAIMS Pro interface enable reproducible identification of a low abundant peptide precursor shown in the insert.
OutlookNew levels of sensitivity are essential for the analysis of limited samples, and for single cells or rare cells such as circulating tumor cells. The Orbitrap Exploris 240 mass spectrometer delivers best-in-class sensitivity required to identify and quantify proteins that reveal biological insights leading to actionable outcomes.
Find out more at thermofisher.com/OrbitrapExploris240Proof
ConclusionWith the FAIMS Pro interface, the Orbitrap Exploris 240 mass spectrometer delivers the high sensitivity needed to identify low abundant proteins from limited samples with reproducibility while maintaining proteome coverage and depth.